The Carrier electronic thermostat
product line consists of programmable
and non-programmable air conditioner,
heat pump, and 2-speed models; a
programmable dual fuel model; and a
programmable/non-programmable
Thermidistat
TM
Control. Carrier also
offers builder’s and standard
programmable thermostats in both air
conditioner and heat pump models.
These units feature non-mercury based
electronic controls built into a subtle,
slim plastic enclosure. They require no
battery back-up.
FEATURES/BENEFITS
THERMIDISTAT CONTROL
The Thermidistat Control and include
the above features plus:
- One model for heating/cooling
- Humidity display
- Humidify output for direct control
of humidifier settings
- Dehumidify output for variablespeed blowers
- Vacation mode controls temperature
and humidity while home is
unoccupied
- Non-programmable set-up option
- Super Comfort Heat mode – when
applied with 40FKA or FK4C
Comfort Heat Package
- Dual Fuel Compatible
- Battery Free
PREMIUM PROGRAMMABLE
CONTROL FEATURES:
- Modes include OFF, COOL, HEAT,
AUTO, and EHEAT (emergency
heat on heat pump models only)
- Fan modes include ON and AUTO
- Equipment ON indicators
- Auto changeover available on all
models (can be disabled)
- Liquid Crystal Display that displays
current room temperature at all
times, and desired temperature/
programming prompts upon
demand
- Backlighting for LCD upon demand
- Large, soft rubber pushbuttons with
tactile action
- Non-volatile memory to retain
setting during a power outage
- Anticipator adjustment controls
sensitivity, cycles per hour
- Seven day programming, with 4
time periods per day
- Hold function for temporarily
overriding program schedule
- Outdoor temperature sensing
(Optional)
- Copy function for ease of
programming
- Auxiliary heat lock-out (Heat pump
and dual fuel models using outdoor
sensor)
- Fan activation--automatic fan with
heat (Optional for packaged units)
- Residential installations eligible for
financing through Retail Credit
Program
- Room temperature sensor offset
allows installer to deliberately
offset indoor room temperature to
accommodate homeowner’s needs.
- Battery Free
DELUXE PROGRAMMABLE
CONTROL FEATURES:
- Modes include OFF, COOL, HEAT,
AUTO, and EHEAT (emergency
heat on heat pump models only)
- Fan modes include ON and AUTO
- Equipment ON indicators
- Auto changeover available on all
models (can be disabled)
- Liquid Crystal Display that displays
current room temperature at all
times, and desired temperature/
programming prompts upon
demand
Model number nomenclature
T STATCCNAC01–B
CC – Carrier Brand
Thermostat
As an ENERGY STAR® Partner,
Carrier Corporation has determined
that the programmable thermostats
and programmable Thermidistat
Control meet the ENERGY STAR®
guidelines for energy efficiency.
2
B – Builder’s Model
S – Standard Programmable
P – Programmable
N – Non-Programmable
R – Wireless Receiver
AC – Air Conditioning
HP – Heat Pump
2S – Two Speed/Two Stage
DF – Dual Fuel
RH – Relative Humidity (Thermidistat
Control)
LH – Light Commerical Humidity
S1 – Slim Line 1 day
S7 – Slim Line 7 day
F1 – Flush Mount 1 day
F7 – Flush Mount 7 day
CO – Cooling only
HO – Heating only
2W – 2 Wire A/C and H/P
B0 – A/C & H/P No Program
B1 – A/C & H/P 1 day
B5 – A/C & H/P 5 day & 2 day
B7 – A/C & H/P 7 day
EC – Reciever
RF – Wireless Sensor
Q5 – 5 + 2 day Single Stage Heat & Cool
Q0 – Single Stage Heat & Cool
Quantity
Series
- Backlighting for LCD configurable
for always on operation
- Large, soft rubber pushbuttons with
tactile action
- Non-volatile memory to retain
setting during a power outage
Temperature set point range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool set points
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Programming days: 7 day
Programming periods: 4—Wake, Day, Eve, Sleep
Hold function
Copy previous day function
Humidity display and control (Thermidistat Control only)
Equipment On indicator (Thermidistat Control only)
Vacation Programming
Standard Programmable Models:
Temperature set point range: 50°F (10°C) to 90°F (32°C)
Manual changeover
Non-volatile memory
Fahrenheit or Celsius selectable
Power-stealing option on AC model only
Selectable fan ON or OFF with auxiliary heating (HP model)
Five-minute compressor timeguard
Four cycles per hour maximum
Auxiliary heat LED on heat pump models
5 & 2 day programming
Temperature set point range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool set points
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Equipment On indicator
Wiring Requirements:
Power: 24vac nominal, 18- to 30-vac, 50/60 Hz
Wiring: Standard 18 to 22 gage.
5
Description
PART NO.DESCRIPTION
TSTATCCPRH01-B
PART NO.DESCRIPTION
TSTATCCPRF01
TSTATCCREC01
TSTATCCPAC01-B
TSTATCCPHP01-B
TSTATCCP2S01-B
TSTATCCPDF01-B
PART NO.DESCRIPTION
TSTATCCPS101
TSTATCCPS701
TSTATCCPF101
TSTATCCPF701
TSTACCPQ501
THERMIDISTAT CONTROL
Thermidistat Control – Non-Programmable/Programmable Thermostat with Humidity Control. (For use in Dual Fuel,
AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
PREMIUM PROGRAMMABLE THERMOSTATS
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, Wireless Transmitter with range up to 500 ft.
Wireless Receiver.
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool in AC Mode,
3-Stage Heat/2-Stage Cool in HP Mode
Dual Fuel Thermostat, Outdoor Temperature Sensor included
DELUXE PROGRAMMABLE THERMOSTATS
Thermostat, Auto Changeover, single Day programmable, Slimline Style
Thermostat, Auto Changeover, 7-day programmable, Slimline Style
Thermostat, Auto Changeover, single day programmable, Flushmount style
Thermostat, Auto Changeover, 7-day programmable, Flushmount style
Thermostat, Auto Changeover, 7-day prog, Slimline Style
STANDARD PROGRAMMABLE THERMOSTATS
PART NO.DESCRIPTION
TSTATCCSAC01
TSTATCCSHP01
TSTATCCPB101
TSTATCCPB501
TSTATCCP2W01
Thermostat, Manual Changeover, 5-2 Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Manual Changeover, 5-2 Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
Thermostat, Programmable, F/°C, simple 1 day programmable, T2 style
Thermostat, 5 +2 day programmable, Super T2 style, F/°C
Thermostat, Programmable, 2-wire, 7-day program schedule, Copy, Vacation, Super T2 style
DELUXE NON-PROGRAMMABLE THERMOSTATS
PART NO.DESCRIPTION
TSTATCCNAC01-B
TSTATCCNHP01-B
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non-programmable air conditioner version and
builder’s and Standard Programmable model thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the
thermostat.
The outdoor air temperature sensor must be used with the dual fuel thermostat.
The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
† This plate is designed to cover surrounding wall area located behind thermostat.
‡ Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used
to replace a broken thermostat wire, or add an extra wire when needed. Do not use this kit with the AC model of the Builder’s or Standard
Programmable thermostat.
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat and Thermidistat Control
Backplate for Builder’s Model Thermostat
Backplate for Standard Programmable Thermostat
Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack
7
Operational information
Five-minute compressor timeguard
This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by
simultaneously pressing the FAN mode button and INCREASE TEMPERATURE (UP) button.
Heat/Cool set points (desired temperature)
A minimum difference of 2° is enforced between heating and cooling desired temperatures. This is done by allowing one
setting to “push” the other, to maintain this difference. (Thermidistat Control is adjustable.) Builder’s thermostats are
controlled by a single set point.
Equipment on indicators (Non-Programmable models)
When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment
is ON, a HEAT ON icon is displayed above the room temperature display.
Equipment on indicators (Thermidistat Control)
When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While
cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will flash. The same is true
for the HEAT icon and its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state
of the humidify and dehumidify outputs. See next section.
Humidify/dehumidify output on indicators (Thermidistat Control)
Within humidity select screen (selected by Humidity button and indicated by “hu” or “dhu” on clock display), the triangle
under humidity set point will be on while humidify output is on. The triangle under dehumidify set point will be on while
dehumidify output is active (turned off, because this output is reverse logic).
Auto changeover
When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode
demand has existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can
be disabled. Builder’s and Standard Programmable thermostats are manual changeover.
Emergency heat mode
When thermostat is controlling a heat pump and emergency heat is selected, all Y signals are locked out, and W becomes
energized upon a call for heat.
Smart Recovery (Programmable models)
With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually
adjusts room temperature so that the desired temperature will be achieved at selected recovery time.
Room Temperature Offset (All models)
Room temperature may be deliberately offset by up to 5°F in either direction.
Maximum On/Off Deadband
Maximum sensed temperature difference between ON and OFF is 0.8°F for Builder’s thermostats and 0.6°F for all other
models.
Copyright 2003 Carrier Corporation
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book14Page 8Catalog No. 02TS-TA6Printed in U.S.A.PC 101Form TSTAT-6PD
Tabmisc misc
Indianapolis, IN 46231 4-03
•
Replaces: TSTAT-5PD
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.