THERMIDISTAT: INDUSTRY LEADING
TEMPERATURE PLUS HUMIDITY CONTROL
PREMIUM PROGRAMMABLE THERMOSTATS
TSTAT
Thermostats
Thermidistat
DELUXE NON-PROGRAMMABLE
THERMOSTATS
STANDARD
NON-PROGRAMMABLE
THERMOSTATS
TM
R
HEAT
COOL
FAN
POWE
DELUXE PROGRAMMABLE THERMOSTATS
Heat Off Cool Fan On Fan Auto
STANDARD PROGRAMMABLE THERMOSTATS
next
run off
prog
set
Heat Off Cool Fan On Fan Auto
BUILDERS
NON-PROGRAMMABLE
THERMOSTAT
Copyright 2003 Carrier Corporation TSTAT-6PD
<
<
The Carrier electronic thermostat product line consists of programmable and non-programmable air conditioner, heat pump, and 2-speed models; a programmable dual fuel model; and a programmable/non-programmable Thermidistat
TM
Control. Carrier also offers builder’s and standard programmable thermostats in both air conditioner and heat pump models. These units feature non-mercury based electronic controls built into a subtle, slim plastic enclosure. They require no battery back-up.
FEATURES/BENEFITS
THERMIDISTAT CONTROL
The Thermidistat Control and include
the above features plus:
- One model for heating/cooling
- Humidity display
- Humidify output for direct control of humidifier settings
- Dehumidify output for variable­speed blowers
- Vacation mode controls temperature and humidity while home is unoccupied
- Non-programmable set-up option
- Super Comfort Heat mode – when applied with 40FKA or FK4C Comfort Heat Package
- Dual Fuel Compatible
- Battery Free
PREMIUM PROGRAMMABLE CONTROL FEATURES:
- Modes include OFF, COOL, HEAT, AUTO, and EHEAT (emergency heat on heat pump models only)
- Fan modes include ON and AUTO
- Equipment ON indicators
- Auto changeover available on all models (can be disabled)
- Liquid Crystal Display that displays current room temperature at all times, and desired temperature/ programming prompts upon demand
- Backlighting for LCD upon demand
- Large, soft rubber pushbuttons with tactile action
- Non-volatile memory to retain setting during a power outage
- Two set points, 1 for heating and 1 for cooling
- Clean filter indicator (Time limit adjustable)
- Auxiliary heat indicator (Heat pump models only)
- Five minute compressor timeguard
- English/Metric (°F/°C) selection (Installer adjustable)
- Anticipator adjustment controls sensitivity, cycles per hour
- Seven day programming, with 4 time periods per day
- Hold function for temporarily
overriding program schedule
- Outdoor temperature sensing (Optional)
- Copy function for ease of programming
- Auxiliary heat lock-out (Heat pump and dual fuel models using outdoor sensor)
- Fan activation--automatic fan with heat (Optional for packaged units)
- Residential installations eligible for financing through Retail Credit Program
- Room temperature sensor offset allows installer to deliberately offset indoor room temperature to accommodate homeowner’s needs.
- Battery Free
DELUXE PROGRAMMABLE CONTROL FEATURES:
- Modes include OFF, COOL, HEAT, AUTO, and EHEAT (emergency heat on heat pump models only)
- Fan modes include ON and AUTO
- Equipment ON indicators
- Auto changeover available on all models (can be disabled)
- Liquid Crystal Display that displays current room temperature at all times, and desired temperature/ programming prompts upon demand
Model number nomenclature
T STAT CC N AC 01 –B
CC – Carrier Brand
Thermostat
As an ENERGY STAR® Partner, Carrier Corporation has determined that the programmable thermostats and programmable Thermidistat Control meet the ENERGY STAR® guidelines for energy efficiency.
2
B – Builder’s Model S – Standard Programmable P – Programmable N – Non-Programmable R – Wireless Receiver
AC – Air Conditioning HP – Heat Pump 2S – Two Speed/Two Stage DF – Dual Fuel RH – Relative Humidity (Thermidistat Control) LH – Light Commerical Humidity S1 – Slim Line 1 day S7 – Slim Line 7 day F1 – Flush Mount 1 day F7 – Flush Mount 7 day CO – Cooling only HO – Heating only 2W – 2 Wire A/C and H/P B0 – A/C & H/P No Program B1 – A/C & H/P 1 day B5 – A/C & H/P 5 day & 2 day B7 – A/C & H/P 7 day EC – Reciever RF – Wireless Sensor Q5 – 5 + 2 day Single Stage Heat & Cool Q0 – Single Stage Heat & Cool
Quantity
Series
- Backlighting for LCD configurable for always on operation
- Large, soft rubber pushbuttons with tactile action
- Non-volatile memory to retain setting during a power outage
- Two set points, 1 for heating and 1 for cooling
- Clean filter indicator (Time limit adjustable)
- Auxiliary heat indicator (Heat pump models only)
- Five minute compressor timeguard
- English/Metric (°F/°C) selection (Installer adjustable)
- Anticipator adjustment controls sensitivity, cycles per hour
- Seven day programming, with 4 time periods per day
- Hold function for temporarily overriding program schedule
- Outdoor temperature sensing (Optional)
- Copy function for ease of programming
- Auxiliary heat lock-out (Heat pump and dual fuel models using outdoor sensor)
- Fan activation--automatic fan with heat (Optional for packaged units)
- Residential installations eligible for financing through Retail Credit Program
- Battery Free
- Room temperature sensor offset allows installer to deliberately offset indoor room temperature to accommodate homeowner’s needs.
- Available in 1-Day Programmable configurations (Model # TSTATCCPS101 or TSTATCCPF101
STANDARD PROGRAMMABLE CONTROL FEATURES
- Rubber push buttons with tactile action
- Modes include HEAT, OFF, and COOL
- Fan modes include AUTO and ON
- Manual changeover
- Battery free
- Mercury free
- English/Metric selection
- Temperature sensor offsets
- Large display
- Battery Free
- Power Stealing option available on AC models only
- Available in 1-Day Programmable configurations (Model # TSTATCCPB101
DELUXE NON­PROGRAMMABLE CONTROL FEATURES
- Modes include OFF, COOL, HEAT, AUTO, and EHEAT (emergency heat on heat pump models only)
- Fan modes include ON and AUTO
- Equipment ON indicators
- Auto changeover available on all models (can be disabled)
- Liquid Crystal Display that displays current room temperature at all times, and desired temperature/ programming prompts upon demand
- Backlighting for LCD upon demand
- Large, soft rubber pushbuttons with tactile action
- Non-volatile memory to retain setting during a power outage
- Two set points, 1 for heating and 1 for cooling
- Clean filter indicator (Time limit adjustable)
- Auxiliary heat indicator (Heat pump models only)
- Five minute compressor timeguard
- English/Metric (°F/°C) selection (Installer adjustable)
- Anticipator adjustment controls sensitivity, cycles per hour
- Outdoor temperature sensing (Optional on all models except non­programmable AC)
- Auxiliary heat lock-out (Heat pump and dual fuel models using outdoor sensor)
- Fan activation--automatic fan with heat (Optional for packaged units)
- Residential installations eligible for financing through Retail Credit Program
- Room temperature sensor offset allows installer to deliberately offset indoor room temperature to accommodate homeowner’s needs.
- Battery Free
STANDARD NON­PROGRAMMABLE CONTROL FEATURES
- Modes include OFF, COOL, HEAT, AUTO, and EHEAT (emergency heat on heat pump models only)
- Fan modes include ON and AUTO
- Equipment ON indicators
- Auto changeover available on all models (can be disabled)
- Liquid Crystal Display that displays current room temperature at all times, and desired temperature/ programming prompts upon demand
- Backlighting for LCD configurable for always on operation
- Large, soft rubber pushbuttons with tactile action
- Non-volatile memory to retain setting during a power outage
- Two set points, 1 for heating and 1 for cooling
- Clean filter indicator (Time limit adjustable)
- Auxiliary heat indicator (Heat pump models only)
- Five minute compressor timeguard
- English/Metric (°F/°C) selection (Installer adjustable)
- Anticipator adjustment controls sensitivity, cycles per hour
- Outdoor temperature sensing (Optional on all models except non­programmable AC)
- Auxiliary heat lock-out (Heat pump and dual fuel models using outdoor sensor)
- Fan activation--automatic fan with heat (Optional for packaged units)
- Residential installations eligible for financing through Retail Credit Program
- Room temperature sensor offset allows installer to deliberately offset indoor room temperature to accommodate homeowner’s needs.
- Battery Free
BUILDERS NON­PROGRAMMABLE CONTROL FEATURES
- Rubber push buttons with tactile action
- Modes include HEAT, OFF, and COOL
- Fan modes include AUTO and ON
- Manual changeover
- Battery free
- Mercury free
- English/Metric selection
- Temperature sensor offsets
- Large display
- Power Stealing option available on AC models only
3
Dimensions
4.75"
Wireless Sensor
4.25"
3.75"
Wireless Receiver
HEAT
1.75"
4.75"
COOL
FAN
POWER
3.25"
4 3⁄8"
Premium Programmable Thermsotat Controls
2.75"
Mode
Fan
.37"
1.12"
4.783"
4.37"
1.18"
1 3⁄8"
4 3⁄8"
7 3⁄
"
8
7
Thermidistat Control
5.50
Fan On Fan Auto
5.54
Heat Off Cool
1 3⁄8"
3
8"
next
3.50
run off
prog
set
1.0
Deluxe Programmable Thermostat Controls
3⁄4"
3.05"
1.0"t
3.05"
1.35"
3 1⁄2"
<
5 1⁄2"
<
3
1
8"
1
3
2"
5 13⁄16"
Deluxe Non-Programmable Thermostat Controls
3.05"
Standard Programmable Thermostat Controls
3.05"
3.05"
1.35"
Standard Non-Programmable Thermostat Control
Heat Off Cool Fan On Fan Auto
5.50 1.00
3.05"
3⁄4"
3.50
2 3⁄4"
<
<
4 1⁄4"
Builder's Model Thermostat Control
4
Product data information
Physical Characteristics
Premium, Deluxe, Standard Programmable; Deluxe, Standard Non-Programmable:
Dimensions: See drawing Appearance: Plastic, eggshell color, textured
Builder’s/Standard Programmable Models:
Dimensions: See drawing Appearance: Plastic, designer white, textured, white, grey rubber push buttons
Electrical Characteristics
Premium, Deluxe, Standard Programmable; Deluxe, Standard Non-Programmable:
Input Volts/Amps: 24vac, 5 VA
Builder’s/Standard Programmable Models:
Input Volts/Amps: 24vac, 1 VA
Environmental Requirements:
Operating Temperature/Relative Humidity: 32°F (0°C) to 104°F (40°C), 95% rh non-condensing Storage Temperature/Relative Humidity: –40°F (–40°C) to 134°F (56°C), 95% rh non-condensing
Program Specifications:
Premium, Deluxe Programmable Models:
Temperature set point range: 40°F (4°C) to 90°F (32°C) Separate heat and cool set points Auto changeover—can be disabled Clean filter reminder: installer adjustable Permanent memory Programming days: 7 day Programming periods: 4—Wake, Day, Eve, Sleep Hold function Copy previous day function Humidity display and control (Thermidistat Control only) Equipment On indicator (Thermidistat Control only) Vacation Programming
Standard Programmable Models:
Temperature set point range: 50°F (10°C) to 90°F (32°C) Manual changeover Non-volatile memory Fahrenheit or Celsius selectable Power-stealing option on AC model only Selectable fan ON or OFF with auxiliary heating (HP model) Five-minute compressor timeguard Four cycles per hour maximum Auxiliary heat LED on heat pump models 5 & 2 day programming
Deluxe, Standard, Builder’s Non-Programmable Models:
Temperature set point range: 40°F (4°C) to 90°F (32°C) Separate heat and cool set points Auto changeover—can be disabled Clean filter reminder: installer adjustable Permanent memory Equipment On indicator
Wiring Requirements:
Power: 24vac nominal, 18- to 30-vac, 50/60 Hz Wiring: Standard 18 to 22 gage.
5
Description
PART NO. DESCRIPTION
TSTATCCPRH01-B
PART NO. DESCRIPTION
TSTATCCPRF01
TSTATCCREC01
TSTATCCPAC01-B
TSTATCCPHP01-B
TSTATCCP2S01-B
TSTATCCPDF01-B
PART NO. DESCRIPTION
TSTATCCPS101
TSTATCCPS701
TSTATCCPF101
TSTATCCPF701
TSTACCPQ501
THERMIDISTAT CONTROL
Thermidistat Control – Non-Programmable/Programmable Thermostat with Humidity Control. (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
PREMIUM PROGRAMMABLE THERMOSTATS
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, Wireless Transmitter with range up to 500 ft.
Wireless Receiver.
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
Dual Fuel Thermostat, Outdoor Temperature Sensor included
DELUXE PROGRAMMABLE THERMOSTATS
Thermostat, Auto Changeover, single Day programmable, Slimline Style
Thermostat, Auto Changeover, 7-day programmable, Slimline Style
Thermostat, Auto Changeover, single day programmable, Flushmount style
Thermostat, Auto Changeover, 7-day programmable, Flushmount style
Thermostat, Auto Changeover, 7-day prog, Slimline Style
STANDARD PROGRAMMABLE THERMOSTATS
PART NO. DESCRIPTION
TSTATCCSAC01
TSTATCCSHP01
TSTATCCPB101
TSTATCCPB501
TSTATCCP2W01
Thermostat, Manual Changeover, 5-2 Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Manual Changeover, 5-2 Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
Thermostat, Programmable, F/°C, simple 1 day programmable, T2 style
Thermostat, 5 +2 day programmable, Super T2 style, F/°C
Thermostat, Programmable, 2-wire, 7-day program schedule, Copy, Vacation, Super T2 style
DELUXE NON-PROGRAMMABLE THERMOSTATS
PART NO. DESCRIPTION
TSTATCCNAC01-B
TSTATCCNHP01-B
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
STANDARD NON-PROGRAMMABLE THERMOSTATS
PART NO. DESCRIPTION
TSTATCCNB001
TSTATCCN2W01
TSTATCCNQ001
Thermostat, Non-programmable, F/°C, 1-Stage Heat/1-Stage Cool, T2 style
Thermostat, Non-programmable, 2-Wire, heat only or cool only, F/°C, T2 style
Thermostat, Auto Changeover, N-P, °F/C°, 1-Stage Heat/1-Stage Cool, battery or 5 wire
BUILDERS NON-PROGRAMMABLE THERMOSTATS
PART NO. DESCRIPTION
TSTATCCBAC01-B
TSTATCCBHP01-B
Thermostat, Manual Changeover, Non-Programmable, °F/°C, 1-Stage Heat/1-Stage Cool
Thermostat, Manual Changeover, Non-Programmable, °F/°C, 2-Stage Heat/1-Stage Cool
6
*
*
Thermostat accessories
PART NO. DESCRIPTION
TSTATXXSEN01-B
TSTATXXNBP01†
TSTATXXPBP01†
TSTATXXBBP01†
TSTATXXSBP01†
TSTATXXCNV10‡
Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non-programmable air conditioner version and builders and Standard Programmable model thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
This plate is designed to cover surrounding wall area located behind thermostat.Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used
to replace a broken thermostat wire, or add an extra wire when needed. Do not use this kit with the AC model of the Builder’s or Standard Programmable thermostat.
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat and Thermidistat Control
Backplate for Builder’s Model Thermostat
Backplate for Standard Programmable Thermostat
Thermostat Conversion Kit (4 to 5 Wire) 10 Pack
7
Operational information
Five-minute compressor timeguard
This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the FAN mode button and INCREASE TEMPERATURE (UP) button.
Heat/Cool set points (desired temperature)
A minimum difference of 2° is enforced between heating and cooling desired temperatures. This is done by allowing one setting to “push” the other, to maintain this difference. (Thermidistat Control is adjustable.) Builder’s thermostats are controlled by a single set point.
Equipment on indicators (Non-Programmable models)
When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment is ON, a HEAT ON icon is displayed above the room temperature display.
Equipment on indicators (Thermidistat Control)
When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will flash. The same is true for the HEAT icon and its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state of the humidify and dehumidify outputs. See next section.
Humidify/dehumidify output on indicators (Thermidistat Control)
Within humidity select screen (selected by Humidity button and indicated by “hu” or “dhu” on clock display), the triangle under humidity set point will be on while humidify output is on. The triangle under dehumidify set point will be on while dehumidify output is active (turned off, because this output is reverse logic).
Auto changeover
When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode demand has existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can be disabled. Builder’s and Standard Programmable thermostats are manual changeover.
Emergency heat mode
When thermostat is controlling a heat pump and emergency heat is selected, all Y signals are locked out, and W becomes energized upon a call for heat.
Smart Recovery (Programmable models)
With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually adjusts room temperature so that the desired temperature will be achieved at selected recovery time.
Room Temperature Offset (All models)
Room temperature may be deliberately offset by up to 5°F in either direction.
Maximum On/Off Deadband
Maximum sensed temperature difference between ON and OFF is 0.8°F for Builder’s thermostats and 0.6°F for all other models.