The Carrier Performancet Series Edget thermostats consists of
programmable and non--programmable air conditioner, heat pump
and Thermidistatt controls. These units feature non--mercury,
non--lead based electronic controls built into a subtle, slim plastic
enclosure.
FEATURES/BENEFITS
Edge Programmable & Non--Programmable
S Outdoor Air Temperature (OAT) sensor option
S Auto changeover available
S Battery free
S Non--volatile memory to retain settings during a power outage
S Keypad lockout
S English/Metric units selection
S Filter/UV light/Humidifier pad replacement indicators
S Continuous display back--lighting configurable
S Hybrid Heat compatible
S RC/RH power compatible
S 2--wire communicating installation option
Edge Programmable models
S ExPt expansion port* for use with future enhancements and/ or
features
S Programmable with personal computer**
S 7, 5 -- 2, All Days programmable
S 4 or 2 periods per day programmability
S Programmable fan by period
S Vacation mode controls temperature and humidity
S Remote room sensor option
S Adjusts automatically for Daylight Savings Time
Edge Non--Programmable models
St programmability
Air Conditioner Control
S 1--stage heat / 1--stage cool
Heat Pump Control
S 3--stage heat / 2--stage cool
Thermidistat Control
S Heat pump 2--stage or Hybrid Heat 3--stage heat / 2--stage
cooling with humidity control
S Humidity display
S Humidify output for direct control of humidifier
S Dehumidify output for variable--speed blowers
S Hybrid Heat compatible
* ExP accessory (expansion port and memory card) sold separately
Fig. 3 -- Performance Series Programmable Thermostat
PRODUCT DATA INFORMATION
Physical Characteristics
Dimensions: See drawing
Mounting: Vertical or horizontal J--box provisions
Electrical
Input volts/amps: 24VAC, 3 VA, RC/RH compatible
Environment
Operating temperature/Relative humidity:32_F(0_C) to
104_F(40_C), 95% RH non--condensing
Storage temperature/Relative humidity:--40_F(--40_C) to
134_F(57_C), 95% RH non--condensing
5.2 in
132.08 mm
Single
Piece
Two
Piece
A07137
5.2 in
132.08 mm
Single
Piece
Two
Piece
A07138
Fig. 4 -- Performance Series Non--programmable Thermostat
Wiring Requirements
Standard 18 to 22 gauge, local wiring codes supersede
Accessories
PAR T NUM BERDESCRIPTION
TSTATXXSEN01--- B*Outdoor air temperature sensor
T P --- E X PExP Expansion Memory Port
T X --- L B P 0 1
ZONECC0RRS01Remote room temperature sensor
* The outdoor air temperature sensor must be used with the Thermidistat
control in a Hybrid Heat system.
LargedecorativebackplateforTP---Pxx
a n d T P --- N x x
2
OPERATIONAL INFORMATION
Heating/Cooling Setpoints
The heating/cooling setpoint range is from 50_F(10_C) to 90 _F
(32_C). A selectable range of 1--6_ is enforced between heating
and cooling desired temperatures. This is done by allowing one
setting to “push” the other, to maintain this difference. (This
difference is adjustable in Installer settings.)
Humidify/Dehumidify Setpoint Range
The humidify setpoint range is from 10% to 46% RH in 2% RH
increments. The dehumidify setpoint range is from 46% to 66%
RH in 2% RH increments.
Five--minute Compressor Time Guard
This timer prevents the compressor from starting unless it has been
off for at least 5 minutes. It can be defeated for 1 cycle by
simultaneously pressing the FAN button and INCREASE
TEMPERATURE (UP) button.
Equipment on indicators
When cooling equipment is ON, a COOL ON icon is displayed.
When heating equipment is ON, a HEAT ON icon is displayed.
When auxiliary heating is ON (HP only), an AUX HEAT icon is
displayed.
Humidify/Dehumidify Output On Indicators
(Thermidistat Control)
When the operating mode is heat and the HUM output is energized
the “humidify” icon shall be displayed. When the operating mode
is cool, the dry contact is configured as a DEHUM output and there
is a dehumidify demand or the cooling equipment is energized to
satisfy a dehumidify demand, the “dehumidify” icon shall be
displayed.
Auto Changeover
When Auto Changeover mode is selected, a change from heat to
cool (or vice versa) will not occur until an opposite mode demand
has existed for 20 minutes. When a setpoint is changed, Auto
Changeover timing is ignored to allow the heating/cooling
equipment to respond quickly. Auto Changeover mode can be
disabled.
Emergency Heat Mode
When the thermostat is controlling a heat pump and emergency
heat is selected, all Y signals are locked out, and W becomes
energized upon a call for heat.
Smart Recovery (Programmable models)
With Smart Recovery selected, transition out of setback begins a
fixed time period (Off, 30, 60, or 90 minutes selectable) before
selected recovery time and gradually adjusts room temperature so
that the desired temperature will be achieved at selected recovery
time.
Room Temperature Offset
Room temperature may be deliberately offset by up to 5_ in either
direction.
Programmable Fan (Programmable models)
This selection allows the homeowner to program the fan selection
to “Auto” or “Fan On” for each of the program schedule periods.