Carrier SBP SMALL BYPASS HUMIDIFIER User Manual

MANUAL
HUMIDISTAT
24 VAC SOLENOID VALVE LEADS
HUMIDIFIER
24 VAC TERMINALS
NOTE: CONNECT SOLENOID VALVE TO HOT WATER IF HUMIDIFIER WILL BE OPERATED INDEPENDENT OF HEATING CALLS.
HUMIDIFIER
TRANSFORMER
(FIELD SUPPLIED)
120 VAC
24 VAC
24 VAC SOLENOID VALVE LEADS
MANUAL
HUMIDISTAT
120 VAC “EAC”
TERMINALS
ON FURNACE
(R) 24 VAC
HOT TERMINAL
NOTE: FOR APPLICATIONS WITH THERMIDISTAT™ REFER TO THERMIDISTAT™ INSTALLATION INSTRUCTIONS.
WARNING: DO NOT CONNECT FURNACE HUM TERMINAL
DIRECTLY TO THERMIDISTAT™ HUM TERMINAL
INDOOR
EQUIPMENT
(HUM) TERMINAL
HUMIDIFIER
THERMIDISTAT™
CONTROL
24 VAC SOLENOID VALVE LEADS
EQUIPMENT
CONTROLLER
HUMIDIFIER
INDOOR
UNIT
24 VAC SOLENOID VALVE LEADS
HUMIDIFIER
INDOOR
UNIT
24 VAC SOLENOID VALVE LEADS
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING
This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.
This product must be installed in compliance with all local, state and federal codes.
ATTENTION INSTALLER:
SBP SMALL BYPASS HUMIDIFIER
The humidifier can be installed on
either the supply or return plenum of
a forced air handling system and is
easily reversible for installation with
righthand or left hand bypass duct
connections. The humidifier
dimensions and serviceability must be
considered when selecting the best
location for the humidifier.
RETURN
SUPPLY
S
RETURN
SUPPLY
S
Horizontal
Upflow
90-1115
90-1116
90-1117
90-1118
90-1119
90-1079
WARNING
1. ELECTRICAL SHOCK HAZARD.
Disconnect electrical power to the furnace and install lock-out tag before starting installation. Failure to do so could result in serious injury from electrical shock.
2.
SHARP EDGES HAZARD. Sharp
edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork.
3.
RISK OF SCALDING. Water
temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line.
SPECIFICATIONS
H
UMIDIFIER DIMENSIONS
Width (
including solenoid valve):
155⁄8
Height
(including drain spud): 13”
Depth
: 10
1
4
BYPASS DUCT OPENING
6” diameter
PLENUM OPENING
91⁄2”W x 91⁄2”H
WATER FEED RATE
3 gph
ELECTRICAL DATA
24 VAC-60 Hz, 0.5 AMP
CAUTION
1. Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home.
2. Do not install humidifier or bypass connection on the furnace cabinet.
3. Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier.
4. Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home.
5. Do not connect humidifier transformer to blower motor wiring. Premature component failure may result.
6. When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control.
7. Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction.
8. Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums.
RISK OF PROPERTY AND EQUIPMENT DAMAGE.
INSTALLATION OPTIONSWIRING DIAGRAMS
HumidiTrac
Automatic Humidifier Control
For detailed Automatic Humidifier Control
installation and wiring instructions,
see Form IM-AHC-02 included with Control.
DIAGRAM A
FOR OPERATION DURING “HEAT CALL” ONLY
DIAGRAM B
FOR OPERATION WHEN BLOWER IS ENERGIZED
DIAGRAM D
ZONING HOOK-UP
WITH EQUIPMENT CONTROLLER
DIAGRAM E
NEW COMMUNICATING CONTROL HOOK-UP
WITH ALL INDOOR EQUIPMENT
DIAGRAM C
FOR HUMIDIFIER OPERATION WITH THERMIDISTAT™ CONTROL
©2010 CAC/BDP
7310 West Morris St., Indianapolis, IN 46231
TEMPLATE MUST BE LEVEL
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING
TEMPLATE MUST BE LEVEL
– TOP –
READ REVERSE SIDE FIRST! READ REVERSE SIDE FIRST!
IM PORTANT ! Be sure owner’s manual containing
instructions for operation and warranty information is given to ownerin order to avoid unnecessary calls.Warranty is voidunless humidifier is installed by qualified heating and air conditioning contractor due to possible misapplication of product.
1. R
emove front cover by pressing center
t
abs on top and bottom of the cover (1) and base (2). Pull feed tube (3) out of the water distribution tray (4). Tip the evaporative assembly forward and lift it out of the humidifier. (See Figure 1)
2. The humidifier comes assembled for left
side discharge. If converting to right side discharge, the base can be rotated so round collar is facing to the right. Swap the location of the hole plug (10) and drain spud (9) if using a right side discharge. To remove the cap, push and twist from inside the housing while lifting the cap up slightly on the outside.To remove the drain spud, twist and push from the outside of the base.
3. Using a level, position this template at
least 3 inches above the furnace housing or cooling coil, if applicable, for clearance of the drain line. Trace around template edges. Remove the template and accurately cut the plenum opening 91⁄2” x 91⁄2”, being careful
to avoid injury from sharp edges.
4. Place the humidifier into the plenum
opening, install six sheet metal mounting screws (not furnished) at the top and sides of the humidifier interior.
5. Install a 6” collar in a convenient location
on the opposite plenum. Attach a 90° elbow and measure the length of 6” round duct required to make the connection. The design of the humidifier collar provides a solid connection with the bypass duct through the use of inside support ribs and pre-formed holes for sheet metal screws. Slip the duct inside the collar of the humidifier, up to the support ribs. Using the pre-formed holes at
the top and bottom of the humidifier collar, s
ecure the duct to the humidifier collar with two sheet metal mounting screws (not furnished). Support bypass ducts longer than 4 feet to prevent sagging.
6. Reinstall the evaporative assembly
back into the base, with the bottom of the scale control insert (6) sitting firmly in the inside of the drain spud (9). Push the feed tube back into the water distribution tray. (See Figure 2) Put the front cover back on. If the nameplate (11) is upside down, remove it by gently squeezing the tabs of the nameplate from inside the cover and pushing out. Rotate the nameplate so it is right side up, and snap back into place. Turn damper handle (8) to the open position “WINTER” for the heating season, or closed position “SUMMER” for the cooling season.
7. Locate and install the Manual Humidifier
Control by following the instructions shown in step #7A. For Automatic Humidifier Control installation instructions, see Form IM-AHC-01 included with the Automatic Control. DISCONNECT
ELECTRICAL POWER TO FURNACE BEFORE PROCEEDING!
LOCATION
1. Locate on inside wall of living area approximately 5 feet above floor, or in the furnace return air plenum or duct. Adapter Plate Part No. 4402 (not included) is required for return air installation. If humidifier is mounted on return duct, control must be at least 6” upstream of humidifier.
2. Do not locate control in the direct path of furnace discharge air or drafts from open doors and windows.
3. Do not installwhere operation mightbe affected by lamps, sunlight, fireplace registers,radiators,concealed air ductsand pipes, or room occupants.
4. The basic rules for location of thermostats also apply to humidifier controls.
8. In order for humidifier to turn on, the
furnace blower must be operating and the Humidifier Control must be calling for humidity. The interface between the humidifier and the furnace to detect blower operation can be accomplished several different ways. See wiring diagrams on other side for options. Do not use furnace blower motor wiring to power transformer. Damage to equipment may result.
9. Tap into a water supply line with
the saddle valve furnished. See instructions on saddle valve package. The humidifier will function with cold, hot, softened or unsoftened water. The use of service hot water (140°F MAX.)
and constant blower operation will provide maximum evaporative capacity. When
installing humidifier on heat pump system, humidifier must be supplied with service hot water.
NOTE: The saddle valve is designed to be fully opened or closed. Do not use it to regulate water flow.
10. Connect tubing from the saddle valve
to the inlet side of the solenoid valve using
1
4” O.D. copper tubing (not furnished).
DOUBLE WRENCH TO PREVENT LEAKING! (See Figure 3)
11.Drain spud is designed to accept
1
2” I.D. plastic hose (not furnished). Run drain line from drain spud to floor drain. CAUTION: If
hose clamp is used, do not over tighten, drain spud could crack. Make sure drain line has constant downward slope and is not kinked. NOTE: Do not sweat or directly attach metal drain line to fitting. Do not use solvent type adhesive when connecting plastic drain line, since damage to fitting could result.
12. Open saddle valve completely and turn
on furnace. Turn up humidifier control so that humidifier will turn on. Allow humidifier to run until water is observed coming out of the drain line. Check to see if humidifier and saddle valve are watertight. Check operation to make sure that all electrical components function properly. Set humidifier control to level recommended in Owner’s Manual.
NOTE: BEFORE LEAVING THE JOB SITE, MAKE SURE:
1. Saddle valve is fully open.
2. All plumbing connections are watertight.
3. Humidifier functions properly.
4. Bypass damper is in proper position.
Figure 1 Figure 2 Figure 3
Form/Catalog: IM-HUM-12
10008994 B2205139A 5.10
7A. MANUAL HUMIDIFIER CONTROL INSTALLATION INSTRUCTIONS:
T
he Manual Humidifier Control is designed for low voltage service to control humidification equipment. An increase in relative humidity expands the nylon ribbon that opens the control switch to stop operation on the humidifier. A decrease in relative humidity reverses the process and closes the control switch.
GENERAL INSTRUCTIONS
1. Do not attempt to repair or recalibrate
humidifier control. Controls requiring service should be returned to your distributor.
2. Use humidifier control in low voltage (24 VAC) applications only. Install 24 VAC wiring to humidifier control as shown in Wiring Diagrams, opposite side.
3. Make sure no bare wires are exposed or insulation damaged. Insulation on wire should extend to head of screws.
4. Make sure all splices are mechanically and electrically secure.
5. To remove dirt or other foreign matter from nylon ribbon and control interior, dust lightly with a fine, soft brush.
90-1067 90-1068 90-1069
1. Front Cover
2. Base
3. Feed Tube
4. Water Distribution Tray
5. Humidifier Pad
6. Scale Control Insert
7. Integral Damper
8. Damper Handle
9. Drain Spud
10. Hole Plug
11. Nameplate
12. Solenoid Valve
12
10
2
7
9
6
11
1
4
3
5
8
90-1172
FURNISHED ITEMS
ITEMS NOT FURNISHED
Built-in bypass damper
2
4 VAC HumidifierControl
Saddle valve
Humidifier Installation Template
Mounting screws (sheet metal screws)
Water supply line (1⁄4” copper)
Drain line (1⁄2” I.D. hose)
24 VAC Transformer
Low voltage wire Bypass ductwork
H
umidifier Control Adapter Plate
P
art No. 4402