J IMPORTANT: Read entire instructions before program-ming the thermostat.
GENERAL
mostats which maintain room temperature by controlling the operation of an HVAC (heating, ventilation trod air condition-
ing) system. Sepm'ate heating and cooling set points and auto-changeover capability allow occupied and unoccupied
programming for energy savings.
During power interruption the internal memory stores tem-
perature and mode settings for an unlimited time. Batteries are not required.
OPERATION
Thermostat Display -- The thermostat display is locat-
ed in the top center of the thermostat. See Fig. 1. The following information can be displayed on the screen:
mode (OFF. HEAT. COOL, EHEAT, or AUTO)
fan setting (ON or AUTO)
auxiliary heat status (P274-0200-C, -0300-C only)
room temperature
desired temperature
reset tilter
outdoor temperature (P274-0200-C, -0300-C only)
Thermostat Buttons --The thermostat has buttons
which are used to change the set points of the thermostat and set the thermostat modes. The buttons are accessible from
behind the thermostat covel: To access the buttons, pull on the hinged thermostat covel: The buttons ;ue: MODE, FAN, and RESET FILTER. See Fig. 1.
The UP and DOWN buttons are used to change the cunent, desired temperature set point and to scroll through program- ming set points. The UP and DOWN buttons am located on the
fi'ont of the thermostat.
Setting Indoor Temperature Set Points
1. Press the UP or DOWN button one time. The LCD
(liquid crystal display) will illuminate and the current temperature set point will be displayed. Next to the temperature display, HEAT or COOL will be dis- played. SET TEMP will appear above the temperature display.
2. To change the temperature set point, continue to press the UP or DOWN buttons until desired temperature is reached. Press the MODE button to set temperature for another setting (Heat or Cool).
Non-Programmable
Thermostat
3. The thermostat will automatically return to regular operation within 5 seconds.
NOTE: The cool setting must be at least 2 degrees higher than the heat setting for proper operation.
Fan Operation -- 33_e FAN button selects fan operation.
The fan can operate in either Fan ON or AUTO mode.
Press the FAN button to switch between fan ON or AUTO
mode. When the fan is set to ON, "FAN" is displayed in the LCD on the thermostat. The fan will mn continuously for im- proved air circulation while in the ON position.
When the fan is set to AUTO mode, the fan runs only as
needed to maintain indoor air temperature. NOTE: The "FAN" indicator will not be displayed in the LCD
when thermostat is operating in AUTO mode.
Mode Operation -- The Mode button selects the operat-
ing mode of the thermostat. Pressing the MODE button will rotate the following options on the LCD: OFF. HEAT. COOL, AUTO, and EHEAT (heat pump models only). The mode for each selection will be displayed on the thermostat when
selected. NOTE: If AUTO is selected, the thermostat will enter Heating
or Cooling mode based on the room temperature and the heat- ing and cooling set points.
Display Outdoor Temperature -- To displaythe
outdoor-air temperature on thermostats offering this feature, simultaneously press the UP and DOWN buttons for twenty
seconds. The outdoor temperature will then be displayed on the LCD.
NOTE: Two dashes "--" appearing on the LCD indicates that the thermostat either does not have this feature installed or the
temperature sensor is not properly connected.
Reset Filter Display -- The thermostat will display
"FILTER" on the LCD when it is time to change or clean the filtel:
After cleaning or changing the filter, press the RESET
FILTER button to restart the timer and turn off the indicator
Auto Changeover Operation -- The thermostat will
provide automatic changeover from Heating to Cooling mode and Cooling to Heating mode when required. The thermostat will automatically switch to maintain the desired temperature setting. The thermostat does not need to be manually changed fi_)m heating to cooling or cooling to heating operation.
Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without Incurring obllgaUons.
REPLACEMENT COMPONENTS DIVISION
©CARRIER CORPORATION 2004 9-04
PRINTED IN U.S.A.
LITERATURE NUMBER P274-7SO
REPLACES: 997-510011-19
CATALOG NO. 570-352
Battery Changeout- If the installation requires tile
usage of batteries, the batteries will require replacement every
NOTE: If installation is hard-wired, batteries are not required and will not need to be replaced.
12 months.
Open thermostat door and slide the battery compartment door to the fight. Remove two AA alkaline batteries. Install two new AA alkaline batteries following the polarity markings
Error Codes --If the thermostat displays "--", "E2",
"E3", or "E4" in the LCD, an error is present. See Table 1 for enor codes and descriptions.
(+ / -) on the thermostat.
Table 1 -- Error Codes
SYMPTOM WHAT TO CHECK Blank LCD Check for 24 vac between R and C at terminal connections or battery.
"--" (2 dashes) on temperature display Temperature sensor reading out of range. Check sensor for damage. If recycling power
"E2" on temperature display Brownout condition or too low of voltage to thermostat. Double check wiring and check for
"E3" on temperature display The outdoor temperature sensor is open, not connected, or shorted.
"SERVICE FILTER" on temperature display After the selected number of hour of blower operation "FILTER" will display on LCD. This is
Cooling will not come on Select COOL mode. Set desired temperature to 10° F below room temperature. Simulta-
Heating will not come on Select HEAT mode. Set desired temperature to 10° F above room temperature. Simulta-
does not clear display, thermostat should be replaced.
24 vac between R and C. E2 will clear 15 sec after proper voltage is restored.
to remind the home owner to "check" the filter. Press RESET FILTER button to clear display and reset timer to 0.
neously press FAN and INCREASE TEMPERATURE buttons to defeat timers. Check for COOL ON icon and 24 vac at Y (first-stage) terminal. If present, thermostat is okay and
3roblem is with equipment or wiring. If not present, replace thermostat.
neously press FAN and INCREASE TEMPERATURE buttons to defeat timers. Check for HEAT ON and 24 vac at Y (first-stage) terminal (with heat pump) or W/W1 (with air condi-
tioner) terminal. If present, thermostat is okay and problem is with equipment or wiring. If not present, replace thermostat.