© Carrier Corporation 04/96 Rev. C 07/04 www.totaline.com Literature Number 570-990
Electronic Air Cleaners
SPECIFICATIONS ELECTRICAL REQUIREMENT
INPUT POWER OUTPUT POWER
PART MAX CELL UNIT
TEMPERATURE
INPUT INPUT NORMAL MAXIMUM OUTPUT OUTPUT
NUMBER CAPACITY WEIGHT WEIGHT RATE VOLTS HZ WATTS WATTS VOLTS AMPERES
P101-1402A
1400 CFM (2) 10 Ibs. ea. 32 Ibs. 32°F (0°C) to
120 50/60 48 55 6.2 kvDC 2.5 mADC
(2380 m
3
/hr.) (4.54 kg.) (14.5 kg.) 125°F (47°C)
P101-2002A
2000 CFM (2) 12 Ibs. ea. 36 Ibs. 32°F (0°C) to
120 50/60 53 61 6.2 kvDC 3.2 mADC
(3400 m
3
/hr.) (5.44 kg.) (16.3 kg.) 125°F (47°C)
P101-2020A
1400 CFM (2) 9 Ibs. ea. 35 Ibs. 32°F (0°C) to
120 50/60 48 55 6.2 kvDC 2.5 mADC
(2380 m
3
/hr.) (4.09 kg.) (15.9 kg.) 125°F (47°C)
Physical Dimensions:
Specifications and Electrical Requirements:
Pressure Drop:
PART
NUMBER 600cfm 1000cfm 1400cfm 2000cfm
P101-1402A .02 .05 .11 n/a
P101-2002A n/a .04 .07 .14
P101-2020A .02 .05 .11 n/a
ABCDEFG
Model P101-1402A Dimensions
20.25 in 13.875 in 16.9375 in 22.5 in 24.875 in 7.125 in 21.4375 in
(514 mm) (352 mm) (430 mm) (572 mm) (632 mm) (181 mm) (541 mm)
Model P101-2002A Dimensions
24.25 in 17.875 in 20.9375 in 22.5 in 24.875 in 7.125 in 21.4375 in
(616 mm) (454 mm) (532 mm) (572 mm) (632 mm) (181 mm) (541 mm)
Model P101-2020A Dimensions
24.25 in 17.875 in 20.9375 in 19 in 21.375 in 7.125 in 18.625 in
(616 mm) (454 mm) (532 mm) (483 mm) (543 mm) (181 mm) (473 mm)
How It Works:
Airborne Actual Micron A Proportionate Particle
Pollutants Particle Size Range Size Comparison
Human Hair 35-200 microns
Pollen 10-100 microns
Spores 10-35 microns
Bacteria .3-35 microns
Animal Dander .3-10 microns
Lung Damaging Dust .5-5 microns
Smoke .01-1 microns
Information Source: American Industrial Hygiene Association
Totaline® Signature Series
Electronic Air Cleaner Effectiveness:
Totaline® Signature
Series Electronic Air
Cleaners are directly
mounted to your
home’s heating and
cooling system.
• The furnace blower
moves the dirty air
into the Electronic
Air Cleaner.
• The prefilter first
removes all of the
larger particulate matter.
• Smaller particles are then given a powerful
positive electrical charge in the charging section.
• These charged particles are then attracted to the
oppositely charged grounded plates, where they adhere
like a magnet until washed away during cleaning.
• Finally the cleaner air passes through the activated
carbon filters for odor removal (optional) and is
recirculated back into your home.
4-Stage Electronic Air Cleaning
Prefilter Charging Grounded Activated
Section Plates Carbon
Filters
(optional)
Also available:
• Optional charcoal after-filter to reduce
household odors.
Information Source: Trion Inc.