Carrier GT-PX(50YER), GT-PW(50YEW), GT-PX(50YD) User Manual

GT-PW (50YEW)
Water-To-Water Series
WATER-TO-WATER PURON® SYSTEMS
SIZE 010 [10 kW]
Revised Aug. 1 2010
GT-PW Water-to-Water (50YEW) Series
Table of Contents
Unit Features .......................................................................................197
Model Key .............................................................................................199
Rated Equipment Performance & Efciencies ..................200
Performance Data .................................................................201-202
Physical Data .......................................................................................203
Dimensions...........................................................................................204
Electrical Data .....................................................................................205
Wiring Diagrams .................................................................... 206-213
Engineering Guide Specications .............................................214
Accessories & Options ..................................................................215
Warranty Information ....................................................................215
Revision History ................................................................................216
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
50YEW Water-To-Water Design Features
The 50YEW series is unlike any other water-to-water heat pump on the market today. The large operating map of the scroll compressor allows high temperature operation, up to 145°F [63°C] leaving load water temperature even at 32°F [0°C] entering source water temperature. The combination of a coaxial (tube-in-tube) heat exchanger for the source (ground loop) side and a brazed plate heat exchanger for the load (heating/hot water) side provides very high efciencies. Integral controls for hydronic heating and domestic water heating avoid the need for external microprocessor-based controls for outdoor temperature reset, warm weather shutdown, staging and other controls.
The 50YEW has an extended range refrigeration circuit, capable of ground loop (geothermal) applications as well as open loop (well water) applications. Standard features and factory-installed options are many. Unique application-specic controls make the 50YEW series ideal for hydronic heating and domestic hot water generation. The heating-only refrigeration circuit is optimized for high water temperatures, heating efciencies, and capacities.
The dual level compressor isolation mounting system, insulated compressor enclosure, and compressor discharge mufer make the 50YEW series one of the quietest water-to-water heat pumps available. The attractive “Euro-style” cabinet allows the unit to t into any decor.
Application Flexibility
• Capacities 10kW [32,600 Btuh].
• High temperature scroll compressor, up to 145°F [63°C] leaving water temperature.
• Ultra high efciencies (4.2 COP at ground loop conditions; up to
5.5 COP at ground water conditions).
• Built-in programmable controller with Outdoor Temperature Reset and Warm Weather Shutdown.
• Large, back-lit digital user interface.
• Rugged coaxial (tube-in-tube) “Source” heat exchanger (copper or cupro-nickel).
• Close approach temperature brazed plate stainless steel “Load” heat exchanger.
• Dual level compressor isolation, compressor enclosure, and discharge mufer for Ultra quiet operation.
• “Euro-style” cabinet for attractive look.
• Insulated cabinet with foil backed insulation for ease of cleaning.
• Flush-mount FPT ttings, secured to the cabinet (no backup wrench required).
• TXV metering device.
• 12-point low voltage terminal strip for ease of installation.
• ETL safety listing.
• Wide variety of options including internally factor y installed Domestic Hot Water Mode, Load and Source side pumps with expansion tanks, VSFP (variable speed oor pump connection) Controls and Cupro-Nickel Source Heat Exchanger.
Service & Installation Advantages
• Hinged front access door and 3 removable panels for ease of installation and service.
• Galvanized steel construction with protective powder coat paint and hinged front access door.
• Bi-directional thermal expansion valve.
®
• Puron
• Circuit breaker protected 75VA control transformer.
• High and low pressure service por ts on refrigerant circuit.
• Accurate refrigerant sensing freeze protection.
Factory Quality & Certications
• All units are built on our Integrated Process Control Assembly
a. Veries that the correct components are being assembled. b. Automatically performs special leak tests on all joints. c. Conducts pressure tests. d. Performs highly detailed run test unparalleled in the HVAC industry. e. Automatically disables packaging for a “failed” unit. f. Creates computer database for future service analysis and
• All units are water run-tested in all modes to insure efciency
• Heavy gauge galvanized steel cabinets are epoxy powder coated
• All refrigerant brazing is done in a nitrogen atmosphere.
• All units are deep evacuated to less than 100 microns prior to
• All joints are both helium and halogen leak tested to insure annual
• Coaxial heat exchanger, refrigerant suction lines and all water
• Noise Reduction features include: dual level compressor isolation,
• Safety features include: high pressure and loss of charge to
• 10-year limited warranty on major refrigerant circuit components,
• AHRI/ASHRAE/ANSI/ISO 13256-2 certied.
• NRTL & CSA listed.
• US EPA “Energy Star” compliant.
• ISO 9001:2000 Certied.
Options & Accessories
• Full Condensing Hot Water Generation With Internal Secondar y
• Factory Installed “Load” and “Source” Pumps.
• Factory Installed Expansion Tanks.
• Cupro-Nickel Source Water Coil.
• Extended Labor Allowance and Service Warranty.
HFC-410A zero ozone depletion refrigerant.
System (IPCS). The IPCS is a unique state of the art manufacturing system that is designed to assure quality of the highest standards of any manufacturer in the water-source industry. Our IPCS system:
diagnostics from run test results.
and reliability.
for durable and long-lasting nish.
refrigerant charging.
leak rate of less than 1/4 ounce.
lines are fully insulated to eliminate condensation problems in low temperature applications.
insulated compressor compartment, interior cabinet insulation using 1/2” coated glass ber, and variable speed fan.
protect the compressor, condensate overow protection, freeze protection sensors to safeguard the coaxial heat exchanger and air coil, hot water high-limit and low compressor discharge temperature switch provided to shut down the hot water generator when conditions dictate. Fault lockout enables emergency heat and prevents compressor operation until thermostat or circuit breaker has been reset.
Optional extended warranties available.
Heat Exchanger and Potable Water Circulating Pump.
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
50YEW Water-To-Water Series Features
1
Euro-Style Cabinet For Attractive Look
2
High Temperature Scroll Compressor
3
Rugged Coaxial “Source” Heat Exchanger
Close Approach Temperature Brazed Plate
4
Stainless Steel “Load” Heat Exchanger
Optional Full Condensing Hot Water
5
Generation With Internal Secondary Heat Exchanger and Potable Water Circulating Pump
Optional Factory Installed “Load” and
6
“Source” Pumps with expansion tanks
Fully Insulated Water and
7
Refrigerant Lines
6
7
5
11
14
4
1
8
Fully Insulated Compressor Section
Powder Coated Galvanized Steel Cabinet
9
and Front Access Panel For Long Life, Taupe Metallic
Large Backlight User Interface
10
Built-In Programmable Controller With
11
Outdoor Temperature Reset and Warm Weather Shutdown
Dual level compressor isolation and discharge
12
mufer for ultra quiet operation
Hinged Front Access Door and Three
13
Removable Panels For Ease of Installation and Service
12-Point Terminal Strip For Ease of Low
14
Voltage Wiring
3
2
12
9
13
10
50YEW
8
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
Model Key
5 0 A0 1 0 CW 3 1 1
Y E W
Prefix
Residential Series
YEW = Puron High Temperature
Heating Only Water-to-Water
1 2 3
4 5 6 7
Unit Size
010 (10kW)
Hydronic Options
A = No Pump B = Load Pump w/Expansion Tank C = Load Pump & Source Pump(s) w/Expansion Tanks
8
9 10 11 12
Controls
W = CXM Y = CXM w/VSFP
Packaging
1 = Single Pack, Domestic
Revision Level
1 = Current
Voltage
3 = 208-230/60/1
Water Coil & DHW Options
C = Copper Source & Braze Plate Load, No DHW D = Copper Source & Braze Plate Load, DHW w/Sec. hx & pump N = Cupro-Nickel Source & Braze Plate Load, No DHW P = Cupro-Nickel Source & Braze Plate Load, DHW w/Sec. hx & pump
*When digit 9 = “D” or “P,” digit 7 cannot be A.”
*
*
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
Rated Equipment Performance & Efciencies
60 Hz (I-P) Units
Ground Loop Heat Pump Ground Water Heat Pump
Heating Heating
Model
50YEW010
THW010 32.6 4.2 30.8 3.3 42.6 5.2 39.9 4.1
Indoor temperature is also called “Load;” outdoor temperature is also called “Source.” Numbers shown with “/” indicate entering/leaving water temperatures. Bold outline indicates typical radiant oor application temperatures. Ratings at 40°C [104°F] are based upon AHRI/ISO Standard 13256-2; all other ratings are based upon Standard EN 14511-2.
Indoor 86/95°F
Outdoor 32/27°F
Capacity
Mbtuh
COP
60 Hz (S-I) Units
Ground Loop Heat Pump Ground Water Heat Pump
Heating Heating
Model
50YEW010
THW010 9.57 4.2 9.03 3.3 12.50 5.2 11.69 4.1
Indoor temperature is also called “Load;” outdoor temperature is also called “Source.” Numbers shown with “/” indicate entering/leaving water temperatures. Bold outline indicates typical radiant oor application temperatures. Ratings at 40°C [104°F] are based upon AHRI/ISO Standard 13256-2; all other ratings are based upon Standard EN 14511-2.
Indoor 30/35°C Outdoor 0/-3°C
Capacity
kW
COP
Indoor 104/113°F
Outdoor 32/27°F
Capacity
Mbtuh
Indoor 40/45°C Outdoor 0/-3°C
Capacity
kW
COP
COP
Indoor 86/95°F
Outdoor 50/45°F
Capacity
Mbtuh
Indoor 30/35°C
Outdoor 10/7°C
Capacity
kW
COP
COP
Indoor 104/113°F
Outdoor 50/45°F
Capacity
Mbtuh
Indoor 40/45°C
Outdoor 10/7°C
Capacity
kW
COP
COP
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
Performance Data - 50YEW010
Source Load
EWT
GPM
°F
20 8.3 1.3 3.1
4.2 0.3 0.8
30
8.3 0.9 2.0
4.2 0.3 0.7
50
8.3 0.7 1.7
4.2 0.3 0.7
70
8.3 0.7 1.7
50YEW operating parameters are as follows: Min Source EWT = 20°F; Max Load LWT = 145°F (see application section for design guidelines). Interpolation is permissible; extrapolation is not. Operation below 40°F EWT (source) is based upon 15% methanol antifreeze solution. All performance data is based upon the lower voltage of dual voltage units. Antifreeze for source water is required for operation in the shaded area and all source EWTs below 40°F.
WPD
PSI FT PSI FT PSI FT
EWT
HC
°F
MBtuh
50 32.3 1.10 28.6 61.9 8.6 0.8 1.7 32.7 1.10 32.7 59.4 8.7 1.8 4.0
70 30.0 1.74 27.7 81.1 5.1 0.6 1.4 30.3 1.68 30.3 78.7 5.3 1.1 2.6
90 27.8 2.41 22.9 100.2 3.4 0.5 1.2 28.0 2.35 28.0 98.0 3.5 1.0 2.2
110 25.5 2.99 18.4 119.4 2.5 0.4 0.9 25.7 2.93 25.7 117.4 2.6 0.8 1.9
50 31.9 1.10 28.1 61.8 8.5 0.8 1.7 32.1 1.11 32.1 58.8 8.5 1.8 4.0
70 29.6 1.74 23.7 80.9 5.6 0.6 1.4 29.7 1.68 29.7 78.1 5.2 1.1 2.6
90 27.4 2.40 19.2 100.1 3.8 0.5 1.2 27.2 2.34 27.2 97.5 3.4 1.0 2.2
110 25.2 2.97 15.1 119.3 2.8 0.4 0.9 24.8 2.91 24.8 116.8 2.5 0.8 1.9
130 22.8 3.68 10.3 138.4 2.1 0.3 0.7 22.4 3.62 22.4 136.2 1.8 0.7 1.6
50 36.3 1.12 32.5 63.4 9.5 0.8 1.7 36.7 1.12 36.7 60.1 9.6 1.8 4.0
70 33.7 1.76 27.7 82.4 5.6 0.6 1.4 34.1 1.7 34.1 79.3 5.9 1.1 2.6
90 31.2 2.43 22.9 101.5 3.8 0.5 1.2 31.5 2.37 31.5 98.6 3.9 1.0 2.2
110 28.7 3 18.4 120.6 2.8 0.4 0.9 28.9 2.94 28.9 117.9 2.9 0.8 1.9
130 26.0 3.72 13.3 139.6 2.1 0.3 0.7 26.3 3.66 26.3 137.2 2.1 0.7 1.6
50 44.2 1.12 40.4 66.3 11.6 0.8 1.7 43.9 1.11 43.9 62.0 11.6 1.8 4.0
70 41.1 1.81 34.9 85.2 7.3 0.6 1.4 40.6 1.71 34.8 81.1 6.9 1.1 2.6
90 38.2 2.53 29.6 104.1 4.8 0.5 1.2 37.5 2.43 29.2 100.3 4.5 1.0 2.2
110 35.1 3.15 24.4 123.0 3.8 0.4 0.9 34.2 3.06 23.8 119.4 3.3 0.8 1.9
130 32.1 3.92 18.7 141.8 2.6 0.3 0.7 31.0 3.82 18.0 138.5 2.4 0.7 1.6
50 48.9 1.13 45.0 68.1 12.7 0.8 1.7 49.3 1.12 49.3 63.5 12.9 1.8 4.0
70 45.5 1.83 39.2 86.8 7.3 0.6 1.4 45.9 1.73 40.0 82.6 7.8 1.1 2.6
90 42.3 2.56 33.5 105.6 4.8 0.5 1.2 42.7 2.46 34.3 101.7 5.1 1.0 2.2
110 38.9 3.18 28.1 124.4 3.8 0.4 0.9 39.3 3.09 28.8 120.8 3.7 0.8 1.9
130
35.5 3.96 22.0 143.1 2.6 0.3 0.7 35.9 3.86 22.7 139.8 2.7 0.7 1.6
50 57.0 1.13 53.1 71.1 14.8 0.8 1.7 56.3 1.12 56.3 65.4 14.8 1.8 4.0
70 53.1 1.87 46.7 89.6 8.3 0.6 1.4 52.0 1.73 46.1 84.2 8.8 1.1 2.6
90 49.6 2.63 40.6 108.3 5.5 0.5 1.2 48.1 2.49 39.5 103.2 5.6 1.0 2.2
110 45.8 3.30 34.5 126.9 4.1 0.4 0.9 44.0 3.17 33.2 122.1 4.1 0.8 1.9
130 41.9 4.11 27.9 145.5 3.0 0.3 0.7 39.8 3.98 26.3 140.9 2.9 0.7 1.6
50 61.4 1.14 57.5 72.7 15.8 0.8 1.7 62.0 1.13 62.0 67.0 16.1 1.8 4.0
70 57.2 1.89 50.8 91.1 8.9 0.6 1.4 57.8 1.75 51.8 85.8 9.7 1.1 2.6
90 53.4 2.66 44.3 109.7 5.9 0.5 1.2 53.9 2.52 45.3 104.8 6.3 1.0 2.2
110 49.3 3.34 37.9 128.2 4.3 0.4 0.9 49.8 3.2 38.9 123.6 4.6 0.8 1.9
130 45.1 4.16 30.9 146.7 3.2 0.3 0.7 45.5 4.02 31.8 142.5 3.3 0.7 1.6
5.4 GPM
PowerkWHE
MBtuh
LWT
°F
COP
WPD
HC
MBtuh
7.3 GPM
PowerkWHE
MBtuh
LWT
WPD
COP
°F
Residential Products Technical Guide
50YEW
50YEW
GT-PW Water-to-Water (50YEW) Series
Performance Data - 50YEW010
Source DHW Circuit
EWT
GPM
°F
6.75 0.8 1.8
20
8.3 1.4 3.2
6.75 0.7 1.7
30
8.3 1.3 3.0
6.75 0.6 1.5
50
8.3 1.2 2.8
6.75 0.6 1.3
70
8.3 1.1 2.6
6.75 0.5 1.2
90
8.3 1.1 2.4
6.75 0.5 1.2
110
8.3 1.0 2.4
50YEW operating parameters are as follows: Min Source EWT = 20°F; Max Load LWT = 145°F (see application section for design guidelines). Interpolation is permissible; extrapolation is not. Operation below 40°F EWT (source) is based upon 15% methanol antifreeze solution. All performance data is based upon the lower voltage of dual voltage units. Antifreeze for source water is required for operation in the shaded area and all source EWTs below 40°F.
WPD
PSI FT PSI FT
EWT
HC
°F
MBtuh
50 28.2 1.78 22.1 66.1 4.6 1.9 4.3 28.3 1.57 22.9 60.4 5.3 3.7 8.6
70 27.1 2.15 19.8 85.5 3.7 1.80 4.2 27.1 1.89 20.7 80.1 4.2 3.6 8.3
90 25.6 2.61 16.7 104.7 2.9 1.8 4.1 25.7 2.29 17.9 99.6 3.3 3.5 8.2
110 23.9 3.16 13.1 123.8 2.2 1.8 4.0 24.0 2.78 14.5 119.0 2.5 3.5 8.1
120 22.9 3.47 11.1 133.2 1.9 1.7 4.0 23.0 3.06 12.6 128.6 2.2 3.5 8.0
50 29.0 1.76 23.0 66.5 4.8 1.9 4.3 29.1 1.55 23.8 60.7 5.5 3.7 8.6
70 27.9 2.12 20.6 85.9 3.8 1.8 4.2 27.9 1.87 21.6 80.4 4.4 3.6 8.3
90 26.4 2.58 17.6 105.2 3.0 1.8 4.1 26.5 2.27 18.7 99.9 3.4 3.5 8.2
110 24.6 3.13 14.0 124.2 2.3 1.8 4.0 24.7 2.75 15.3 119.2 2.6 3.5 8.1
120 23.6 3.44 11.9 133.6 2.0 1.7 4.0 23.7 3.02 13.4 128.9 2.3 3.5 8.0
50 33.4 1.82 27.2 69.0 5.4 1.8 4.3 34.2 1.61 28.7 62.6 6.2 3.7 8.6
70 31.5 2.20 24.0 88.0 4.2 1.8 4.2 32.2 1.95 25.6 81.9 4.8 3.6 8.3
90 29.5 2.70 20.3 107.0 3.2 1.8 4.1 30.2 2.40 22.0 101.2 3.7 3.5 8.2
110 27.5 3.31 16.2 125.8 2.4 1.8 4.0 28.1 2.94 18.0 120.5 2.8 3.5 8.1
120 26.4 3.66 13.9 135.2 2.1 1.7 4.0 27.0 3.24 15.9 130.1 2.4 3.5 8.0
50 34.8 1.78 28.7 69.8 5.7 1.9 4.3 35.5 1.58 30.1 63.1 6.6 3.7 8.6
70 32.8 2.16 25.4 88.7 4.4 1.80 4.2 33.5 1.91 27.0 82.4 5.1 3.6 8.3
90 30.7 2.65 21.7 107.6 3.4 1.8 4.1 31.4 2.35 23.4 101.7 3.9 3.5 8.2
110 28.5 3.25 17.5 126.5 2.6 1.8 4.0 29.2 2.88 19.4 120.9 3.0 3.5 8.1
120 27.4 3.59 15.2 135.8 2.2 1.7 4.0 28.1 3.18 17.2 130.5 2.6 3.5 8.0
50 43.1 1.91 36.5 74.5 6.6 1.9 4.3 45.7 1.72 39.8 66.8 7.8 3.7 8.6
70 40.3 2.35 32.3 93.1 5.0 1.8 4.2 42.7 2.11 35.6 85.8 5.9 3.6 8.3
90 37.4 2.85 27.7 111.5 3.8 1.8 4.1 39.6 2.57 30.9 104.8 4.5 3.5 8.2
110
34.3 3.43 22.5 129.7 2.9 1.8 4.0 36.3 3.09 25.8 123.6 3.4 3.5 8.1
120 32.6 3.75 19.8 138.8 2.5 1.7 4.0 34.6 3.37 23.1 132.9 3.0 3.5 8.0
50 45.2 1.85 38.9 75.7 7.1 1.6 4.3 47.9 1.67 42.2 67.7 8.4 3.7 8.6
70 42.3 2.28 34.6 94.2 5.5 1.8 4.2 44.9 2.05 37.9 86.6 6.4 3.6 8.3
90 39.3 2.77 29.8 112.5 4.2 1.8 4.1 41.6 2.49 33.1 105.5 4.9 3.5 8.2
110 36.0 3.33 24.6 130.7 3.2 1.8 4.0 38.1 3.00 27.9 124.2 3.7 3.5 8.1
120 34.2 3.64 21.8 139.8 2.8 1.7 4.0 36.3 3.27 25.1 133.6 3.3 3.5 8.0
50 49.5 1.96 42.8 78.1 7.4 1.9 4.3 54.1 1.79 48.0 70.0 8.9 3.7 8.6
70 46.9 2.41 38.7 96.8 5.7 1.8 4.2 51.3 2.20 43.8 89.0 6.8 3.6 8.3
90 43.7 2.95 33.6 115.1 4.3 1.8 4.1 47.8 2.70 38.6 107.8 5.2 3.5 8.2
110 39.9 3.60 27.6 133.0 3.2 1.8 4.0 43.7 3.28 32.5 126.3 3.9 3.5 8.1
120 37.7 3.96 24.2 141.8 2.8 1.7 4.0 41.3 3.61 29.0 135.5 3.4 3.5 8.0
50 32.8 1.88 26.3 68.6 5.1 1.9 4.3 35.9 1.72 20.0 63.2 6.1 3.7 8.6
70 52.4 2.31 44.5 100.0 6.6 1.8 4.2 57.4 2.11 50.2 91.3 8.0 3.6 8.3
90 49.7 2.83 40.0 118.5 5.1 1.8 4.1 54.4 2.59 45.6 110.2 6.2 3.5 8.2
110 46.3 3.45 34.5 136.7 3.9 1.8 4.0 50.7 3.15 39.9 128.9 4.7 3.5 8.1
120 42.3 3.80 29.3 144.4 3.3 1.7 4.0 46.3 3.46 34.5 137.3 3.9 3.5 8.0
50 55.9 2.01 49.0 81.8 8.2 1.9 4.3 62.9 1.86 56.5 73.2 9.9 3.7 8.6
70 53.46 2.47 45.0 100.6 6.4 1.8 4.2 60.2 2.28 52.4 92.3 7.7 3.6 8.3
90 50.0 3.05 39.6 118.7 4.8 1.8 4.1 56.3 2.82 46.7 111.0 5.8 3.5 8.2
110 45.5 3.76 32.7 136.2 3.5 1.8 4.0 51.3 3.48 39.4 129.1 4.3 3.5 8.1
120 42.9 4.17 28.7 144.8 3.0 1.7 4.0 48.3 3.85 35.2 138.1 3.7 3.5 8.0
50 60.9 1.92 54.3 84.6 9.3 1.9 4.3 68.5 1.77 62.5 75.3 11.3 3.7 8.6
70 58.3 2.35 50.2 103.3 7.3 1.8 4.2 65.6 2.18 58.2 94.3 8.8 3.6 8.3
90 54.5 2.91 44.6 121.3 5.5 1.8 4.1 61.4 2.69 52.18 112.8 6.7 3.5 8.2
110 49.6 3.59 37.4 138.6 4.0 1.8 4.0 55.9
120 46.8 3.98 33.2 147.0 3.4 1.7 4.0 52.6 3.68 40.1 139.7 4.2 3.5 8.0
50 59.3 2.04 52.4 83.8 8.5 1.9 4.3 68.4 1.91 61.9 75.2 10.5 3.7 8.6
70 57.4 2.54 48.7 102.8 6.6 1.8 4.2 66.2 2.38 58.1 94.6 8.1 3.6 8.3
90 54.1 3.18 43.3 121.1 5.0 1.8 4.1 62.4 2.98 52.3 113.2 6.1 3.5 8.2
110 49.5 3.96 36.0 138.5 3.7 1.8 4.0 57.1 3.71 44.4 131.3 4.5 3.5 8.1
50 64.7 1.94 58.0 86.8 9.8 1.9 4.3 74.6 1.82 68.4 77.5 12.0 3.7 8.6
70 62.6 2.42 54.3 105.8 7.6 1.8 4.2 72.2 2.27 64.5 96.8 9.3 3.6 8.3
90 59.0 3.03 48.7 123.9 5.7 1.8 4.1 68.1 2.84 58.4 115.3 7.0 3.5 8.2
110 53.9 3.77 41.1 141.1 4.2 1.8 4.0 62.2 3.53 50.2 133.2 5.2 3.5 8.1
GPM=3.5
PowerkWHE
MBtuh
LWT
COP PSI FT
°F
WPD
HC
MBtuh
Carrier : Turn to the Experts.
LGPM=5.4
PowerkWHE
MBtuh
3.32 44.53 130.9 4.9 3.5 8.1
LWT
°F
WPD
COP
Carrier Geothermal Heat Pump Systems
Physical Data
Model 010
Compressor (qty) 1
Factory Charge HFC-410A (oz) [kg] 88 [2.50]
Indoor/Load Water Connection Size
FPT (in) 1
Outdoor/Source Water Connection Size
FPT (in) 1
Domestic Hot Water Connection Size
FPT (in) 3/4
Maximum Working Pressure (Water Side)
Base Unit (PSIG) [kPa] 500 [3445]
DHW Option (PSIG) [kPa] 145 [999]
Internal Source Pump w/Expansion Tank (PSIG) [kPa]
Internal Load Pump w/Expansion Tank (PSIG) [kPa]
Weight - Operating, (lbs) [kg] 455 [207]
Weight - Packaged, (lbs) [kg] 470 [214]
*
*
45 [310]
45 [310]
Dual isolation compressor mounting Balanced Port Expansion Valve (TXV) Insulated Source and Load Water Coils
*Does not apply to DHW potable water circuit
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
50YEW Dimensions
1.9” [4.9cm]
2.1” [5.3cm]
50YEW
Overall Cabinet
Model
A
DepthB WidthC Height
in. 26.8 25.6 48.9 3.4 8.1 22.3 11.3 17.7 14.4 33.6 35.6 38
010
cm. 68.1 65.1 124.2 8.6 20.6 56.6 28.7 45 36.6 85.3 90.4 96.5
1 2 3 4 5 6
D
Source
(Outdoor)
Water In
Source
(Outdoor)
Water Out
Water Connections
E
(Indoor)
Water In
F
Load
G
DHW
Water Out
H
Load
(Indoor)
Water Out
J
DHW
Water In
Electric Access Plugs
K
Low
Voltage
Carrier : Turn to the Experts.
L
Low
Voltage
M Power Supply
Carrier Geothermal Heat Pump Systems
Units with DHW Option
Model
50YEW010
THW010 G 208-230/60/1 197/254 1 20.7 81
Model
50YEW010
THW010 G 208-230/60/1 197/254 1 20.7 81
Voltage
Code
Voltage
Code
Voltage
Voltage
Min/Max
Voltage
Min/Max
Voltage
*Denotes optional items. Consult unit data plate if conguration is unknown.
Compressor
Qty RLA LRA
Standard (No DHW)
Compressor
Qty RLA LRA
Electrical Data
*Load
Pump
FLA
1.07 - 1.07 22.8 28 45
1.07 1.07 1.07 23.9 29.1 45
*Load
Pump
FLA
1.07 - 21.8 26.9 45
1.07 1.07 22.8 28 45
*Source
Pump
FLA
*Source
Pump
FLA
ISBP
Pump
FLA
Total
Unit FLA
Total
Unit FLA
Min
Circuit
Amps
Min
Circuit
Amps
Max
Fuse
HACR
Max
Fuse
HACR
Electrical - Wiring Diagram Matrix
Model
50YEW010 96B0108N05 230/60/1 -
50YEW010 96B0108N06 230/60/1 VSFP
50YEW010 96B0108N08 230/60/1 DHW
50YEW010 96B0108N09 230/60/1 DHW + VSFP
Diagram
Number
Voltage Option
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
Electrical Wiring Diagrams
50YEW010 Electrical Wiring Diagram - 230/60/1 96B0108N05
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
50YEW010 Electrical Wiring Diagram - 230/60/1
96B0108N05
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
50YEW010 Electrical Wiring Diagram - 230/60/1 VSFP - 96B0108N06
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
50YEW010 Electrical Wiring Diagram - 230/60/1
VSFP - 96B0108N06
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
50YEW010 Electrical Wiring Diagram - 230/60/1 DHW - 96B0108N08
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
50YEW010 Electrical Wiring Diagram - 230/60/1
DHW - 96B0108N08
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
50YEW010 Electrical Wiring Diagram - 230/60/1 DHW + VSFP - 96B0108N09
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
50YEW010 Electrical Wiring Diagram - 230/60/1
DHW + VSFP - 96B0108N09
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
Engineering Guide Specications
General
The water-source heating units shall be high temperature water-to­water heat pumps. Units shall be performance rated in accordance with EN 14511-2 or ARI/ISO/ASHRAE 13256-2, and listed by a recognized safety-testing laboratory or agency, such as ETL. Each unit shall be water run-tested at the factory. The quality control system shall automatically perform via computer: triple leak check, pressure tests, evacuate and accurately charge system, perform detailed heating mode tests, and quality cross check all operational and test conditions to pass/fail data base. Each unit shall be pallet mounted and shipped with appropriate protective packaging to help avoid damage in transportation.
The units shall be warranted by the manufacturer against defects in materials and workmanship for a period of 10 years on all parts, and 10 years on the compressor and refrigerant circuit par ts with a service labor allowance for 5 years on refrigeration components and 2 years on other parts. An optional extended warranty is available for the 50YEW Series units, which increases the labor allowance to 10 years on all parts. The water source units shall be designed to operate with entering Source temperature between 20 and 110°F [-7 and 43°C], and entering Load temperature between 50 and 130°F [10 and 54°C] with a maximum leaving load temperature of 145°F [63°C].
Casing & Cabinet
The cabinet shall be fabricated from heavy-gauge galvanized steel and painted with a polyester powder coating. Access door shall be hinged for easy access. The interior shall be insulated with 1/2” [13mm] thick, multi-density, foil-backed coated glass ber. Three access panels shall be provided and shall be removable with piping in place. The internal component layout shall provide for major service with the unit in place for restricted access installations. The units shall have an insulated compressor section to minimize the transmission of compressor noise.
Refrigerant Circuit
All units shall contain Puron® (HFC-410A) sealed refrigerant circuit employing a hermetic motor-compressor, thermal expansion valve, coaxial tube water-to-refrigerant Source heat exchanger, brazed plate Load heat exchanger, compressor discharge mufer, 100% molecular sieve lter drier with XH-11 desiccant, and service ports. An optional Domestic Hot Water mode shall be available. Compressors shall be scroll type designed for heat pump duty and shall be double isolated from the cabinet with two sets of compressor mounting hardware. Compressor motors shall be single-phase PSC with internal over load protection.
The coaxial water-to-refrigerant heat exchangers shall be designed for close approach temperatures and be constructed of a convoluted copper (optional cupro-nickel) inner tube and steel outer tube. The brazed plate heat exchanger shall be designed for close approach temperatures and shall be constructed with stainless steel plates. The thermal expansion valve shall provide proper superheat over the entire uid temperature range with minimal “hunting”. The coaxial heat exchangers and refrigerant suction lines shall be insulated to prevent condensation at low liquid temperatures.
Electrical
CXM Control – A microprocessor-based compressor controller shall be provided to monitor and control unit operation. The control shall provide compressor enable, high and low pressure monitoring, eld selectable water coil low temperature sensing, and over/under voltage monitoring. The control shall also provide for water valve connection, a test mode, short cycle protection, random start­up, as well as fault LED, fault memory, and intelligent fault retry. The control shall employ quick attach harness assemblies for low voltage connections to the control board to aid in troubleshooting or replacement. An integral terminal block with screw terminals shall be provided on the control for connection to other low voltage controls. The control system microprocessor board shall be specically designed to protect against building electrical system noise contamination, EMI, and RFI interference.
MPC Control – A programmable controller shall be provided to monitor buffer tank temperature, Domestic Hot Water (DHW) tank temperature, outdoor air temperature, and other inputs to determine when to operate the compressor, pump(s) and hot water valve. The MPC shall be factory-wired to the CXM compressor control module and user interface. MPC programming shall include outdoor temperature reset, warm weather shutdown, cooling enable, heat pump staging, emergency DHW output, pump control, vacation mode, DHW time schedule, advanced diagnostics, user interface communication, and sensor monitoring.
Digital User Interface – A panel-mounted backlit digital user interface shall be factory installed and wired for customization of the MPC programming. Four arrow keys and a select key will be used to control a large dot-matrix style 2” x 2” (5 x 5 cm) backlit display. The main screen shall display current outdoor and water temperatures, and allow the user to change settings by selecting from one of the menus at the bottom of the screen. A special installer set up mode will allow the technician to change some of the default MPC parameters. The user interface shall include a time schedule for DHW operation, Fahrenheit/Celsius selection, vacation mode for DHW, and other user preference options.
12-point terminal block – A low voltage terminal block with a blue/ gray pattern for ease of identication shall be provided to connect thermistors and external wiring. The MPC, user interface, CXM board and other relays/components shall be factory-wired to the terminal block.
Line voltage lugs shall be provided for unit wiring. A circuit breaker protected 75VA transformer shall be employed. Units shall have knockouts for entrance of low and line voltage wiring.
Piping
Source/Load supply and return water connections, as well as Domestic Hot Water supply and return connections shall be FPT (Female Pipe Thread) copper ttings and shall be securely mounted ush to the cabinet allowing for connection to an MPT (Male Pipe Thread) tting without the use of a back-up wrench. All Source water piping shall be insulated to prevent condensation at low liquid temperatures.
50YEW
Carrier : Turn to the Experts.
Carrier Geothermal Heat Pump Systems
Accessories & Warranty
Accessories & Options
Hot Water Mode Option
An optional mode to provide domestic hot water shall be provided. This mode shall include a factory-installed, internal secondary heat exchanger and a factory-installed potable water, bronze circulating pump. This option shall provide an additional set of water connections for the potable domestic hot water and shall be completely factory installed and wired. An external sensor shall be provided to sense the domestic water storage tank temperature.
Internal Source and Load Pumps / Internal Expansion Tanks
Optional Source pump(s), Load pump, and expansion tank(s) shall be factory installed and wired to help lower installation costs and labor. When installed at the factory, pumps are controlled by the MPC.
Variable Speed Floor Pump Connection
An optional relay and line voltage lugs shall be provided for a variable speed radiant oor system pump. Some radiant oor systems utilize a variable speed pump on the oor system, which changes ow based upon the number of zones open or closed. Since the pump has built-in controls, only a power supply is needed.
Warranty Information
The 2010 standard warranty applies to units ordered on or after July 1, 2010. See Carrier’s 2010 Limited Express Residential Warranty Certicate CA234 for specic coverage and limitation.
Carrier residential class heat pumps are backed by a ten-year limited warranty on all unit par ts, including the following accessories when installed with Carrier units: Flow Controllers & Electric Heaters.
Carrier goes even further to back up its commitment to quality by including a service labor allowance for the rst ve years on refrigeration circuit components and two years on all other par ts, auxiliary heaters and geothermal pumping modules.
The Optional Extended Factory Ser vice Labor Allowance Warranty offers additional length of term protection to the consumer by offsetting service labor costs for 10 years.
To order this warranty, contact your Carrier distributor. This coverage must be purchased within 90 days of unit installation. See Limited Express Extended Labor Warranty Certicate CA235 for details.
Cupro-Nickel Heat Exchanger
An optional corrosion resistant CuNi coaxial heat exchanger shall be factory installed in lieu of standard copper construction (Source heat exchanger only).
Flow Controller (eld installed)
A self-contained module shall provide all uid pumping, ll and connection requirements for ground-source closed­loop systems up to 20 GPM [76 l/m]. The Flow Controller shall provide 1” pump isolation valves/3-way service valves. Pump heads shall be removable from the volute for easy replacement. The Flow Controller shall be enclosed in a polystyrene case and fully insulated with urethane foam to prevent condensation. The Flow Controller shall have a 5- year warranty on all par ts.
Hose Connection Kit (eld installed)
An accessory hose kit shall provide 150psi [1034 kPa] 1” rubber hose with brass ttings equipped with service pressure/ temperature ports for connection between the unit and Flow Controller.
Residential Products Technical Guide
50YEW
GT-PW Water-to-Water (50YEW) Series
Revision History
Date Page # Description
21 July, 10
01 June, 10 Various Warranty, Paint, Nomenclature Updates
30 Mar, 10 All Misc. format, physical data, and electrical data
30 Mar, 10 Decoder Page Decoder Updated
1 Mar, 10 All Misc. format and desc. updates
15 Dec, 09 All Updated Performance pages, added DHW mode information
01 Jan, 09 All Reformatted Document Size
01 Oct, 06 All First Published
Wiring Diagram