Y ou can be justifiably proud of your purchase because the same pride in craftsmanship and engineering know-how that goes into Carrier equipment for cooling the Astrodome sports complex in Texas, the United States Capitol,s Halls of Congress and countless other installations worldwide have been built into your unit.
One of the pleasant benefits awaiting you with room air conditioning is that in addition to being cooled, the room air is filtered and dehumidified. This owner,s manual is designed to help you be familiar with the many comforts and techno­logical features your unit offers. Moreover, it contains vital information about maintenance, service and economical operation. Take the next few minutes to discover for yourself how to get the most in personal comfort and economical operation from your new Carrier room air conditioner .
PRECAUTIONS BEFORE OPERATION
UNIT DESCRIPTION REMOTE CONTROL DESCRIPTION REMOTE CONTROL PREPARATION
UNIT OPERATION
AUTOMATIC OPERATION MANUAL OPERATION TIMER OPERATION DISCHARGE AIR LOUVER CONTROL EMERGENCY AND TEST OPERATION AIR CLEANING OPERATION
CARE AND MAINTENANCE
POINTS TO NOTE CLEANING THE FILTERS AND FRONT PANEL CLEANING THE MAIN UNIT AFTER-SEASON CARE
TROUBLESHOO TING
CONTENTS
2 6
6
8 11 13 13
14 15 20
21 22 23 23 25 26 26 27
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○
○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○
PRECAUTIONS
Installing and servicing air conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install or service this equipment. Untrained personnel can perform basic maintenance functions such as cleaning the coil and filters, and replacing filters. All other operations should be performed by trained service personnel. When working on air conditioning equipment, observe precautions in the literature, tags and labels attached to the unit.
Use the correct voltage. Using voltage other than specified will damage the unit.
Check the power plug. If the power plug is not inserted tightly, or if there is any damage to the power cord, it could result in leakage or electric shock.
Do not use the power cord as a means of turning off the unit.
Before performing service or maintenance operations on the system, turn off the main power of the unit. Electric shock can cause personal injury.
WARNING
WARNING
WARNING
WARNING
OWNER,S MANUAL - 2
PRECAUTIONS
Do not use flammable sprays near the unit. The unit can be damaged by gasoline, benzene, thinners, insecticides and other chemical agents.
When unplugging the power plug, do not pull by the power cord. The power cord will get damaged and it can cause electric shock.
To avoid the risk of serious electric shock, never splash the indoor and the outdoor unit with water.
Do not put hands or objects into the discharge grille of outdoor unit. This unit has a fan running at high speed. It is very dangerous to touch the fan.
Use only fuses of the proper amperage.
WARNING
WARNING
WARNING
WARNING
WARNING
OWNER,S MANUAL - 3
PRECAUTIONS
Be careful to keep the room temperature a comfortable level. A void continuous direct air flow to the occupant, especially in case of sleeping persons or hospital patients.
Do not obstruct the front of the discharge grille of both units. This will block air flow, reduce the cooling effect and may result in unit malfunction.
Ventilate the room when it becomes stuffy or filled with undesirable odors.
Keep heat sources away from the unit; high temperature can cause damage.
Set a comfortable temperature. Very low or very high temperature setting consider­ably increase power consumption.
WARNING
WARNING
WARNING
WARNING
WARNING
27°C
OWNER,S MANUAL - 4
PRECAUTIONS
To circulate the room air only, operate at the FAN mode.
In summer, if possible, prevent direct sunlight from entering the room; draw curtains or blinds.
Use the timer correctly to maintain comfort conditions.
Please read this owner,s manual carefully before operating the unit. It contains further important instructions for proper operation.
WARNING
WARNING
WARNING
WARNING
OWNER,S MANUAL - 5
BEFORE OPERA TION
O
N /
O
F F
T E
M
P
S L
E E
P
ROOM AIR INLET
AIR FILTER
ACTIVE CARBON FILTER &
OPTION 2 : PHOTO-CA TAL YST FILTER
REMOTE CONTROL SIGNAL RECEIVER
AIR SWING FLAP
VERTICAL LOUVER
ROOM AIR OUTLET
POWER PLUG
LCD REMOTE CONTROL
OUTDOOR AIR OUTLET
OUTDOOR AIR INLET
INDOOR AND OUTDOOR
CONNECTION
DRAIN HOSE
UNIT DESCRIPTION
Indoor Unit
Outdoor Unit
OWNER,S MANUAL - 6
OPTION 1 : ELECTROST ATIC FILTER
BEFORE OPERA TION
Switch Panel
• UNIT ON(Green): When the unit is switched on by the remote control, a green light will be displayed.
• TIMER(Orange) : When the unit is in reservation mode, an orange light will be displayed.
• EMERGENCY button :
Can be used when the remote control is lost or inoperative.
• TEST button :
Is only used by service men to test the unit operation.
For the usage of EMERGENCY and TEST buttons, refer to EMERGENCY AND TEST OPERA TION, p.21.
Indoor Unit Display
EMERGENCY TEST