58PHA/PHX PERFORMANCE™ BOOST 80
4 --- WAY M U LTI P O I S E
INDUCED---COMBUSTION GAS FURNACE
Input Capacities: 45,000 thru 135,000 Btuh
Series 110/120
Product Data
58PHA/PHX furnaces are approved for use with natural or propane
gas, and the 58PHX is approved for use in Low NOx Air Quality
Management Districts.
STANDARD FEATURES
S ECM Blower Motor included
S QuieTecht noise reduction system
S SmartEvapt—Humidity control when using a
Thermidistatt Control
S ComfortFant—adjustable constant fan speed from the
thermostat
A10251
THE CARRIER PERFORMANCEt BOOST 80
GAS FURNACE
The 58PHA/PHX 4--way Multipoise Gas Furnaces offer deluxe
features not found in other single--stage 80% gas furnaces. The
ECM motor and Carrier’s control logic combine to provide a
SEERBOOSTofupto1.5points.*Carrier’sQuieTecht noise
reduction system makes the Performancet Boost 80 an incredibly
quiet induced--draft gas furnace.
The gas furnace control system provides a dehumidification mode,
a motor speed selection for continuous fan operation selectable at
the thermostat, and fault code storage in the event of power
outages. Applications are easy with 4--way multipoise design,
through--the--furnace downflow venting, 13 different venting
options, and a design for easy service access. An inner blower door
is provided for tighter sealing in sensitive applications. The
S Microprocessor based control center
Enhanced diagnostics with LED and reflective sight glass.
Stores fault codes during power outages
Adjustable heating air temperature rise
Adjustable cooling airflow
Dehumidification selection for summer--time cooling
S 4--way Multipoise furnace, 13 vent applications
S Compact design -- only 33--1/3 in. (847 mm) tall
S Power Heat SiNt Igniter
S Draft safeguard switch to ensure proper furnace venting
S Insulated blower compartment
S Inner door for tighter sealing
S Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In.
Water Gauge with all present air inlets and air outlet sealed.
S HYBRID HEAT Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Residential installations eligible for consumer financing
through the Retail Credit Program
*as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil ---only rating when paired with selected Carrier evaporator coils.
1
FURNACE COMPONENTS
INDUCER MOTOR
ASSEMBLY
PRESSURE
SWITCH
FLUE COLLECTOR
BOX
GAS VALVE
58PHA
MANUAL RESET
LIMIT SWITCHES
HOT SURFACE
IGNITOR
VENT
ELBOW
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
BLOCKED VENT
SWITCH
FLAME
SENSOR
GAS MANIFOLD
GAS BURNER
BLOWER
DOOR SAFETY
SWITCH
FURNACE
CONTROL
BOARD
BLOWER AND
MOTOR
CAPACITOR/
POWER CHOKE
A10314
NOTE: The 58PHA/PHX Furnaces are factory shipped for use with natural gas. These furnaces can be field--converted for propane gas with
a factory--authorized and listed accessory conversion kit.
2
MODEL NUMBER NOMENCLATURE
A
B
[736.9]
29
Ø7/8
[22.2]
ACCESSORY
5 15/16
[150.7]
28.39
[721.2]
Ø7/8
[22.2]
ACCESSORY
14 7/8
[337.3]
(BOTH SIDES)
Ø7/8
[22.2]
ACCESSORY
Ø7/8
[22.2]
ACCESSORY
Ø1 3/4
[44.5]
GAS ENTRY
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
11 7/16
[290.7]
9 11/16
[245.4]
[197.8]
7 13/16
Ø7/8
[22.2]
J.BOX PROVISION
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
1 15/16
[49.2]
1
[25.4]
1 1/4
[31.8]
29 9/16
[750.7]
1 15/16
[49.2]
5 5/8
[143.3]
5 7/16
[138.5]
6 13/16
[172.3]
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
19
[481.7]
OUTLET
D
21.6
[549.5]
BOTTOM INLET
C
33 1/4
[843.9]
9 9/16
[243.3]
3/4
[19.1]
5 7/8
[148.5]
3 7/16
[86.8]
9 7/8
[250.7]
27 3/4
[704.7]
2 5/16
[59]
FRONT OF CASING
TOP OF CASING
4 13/16
[122.2]
27 3/4
[704.7]
5 7/8
[148.5]
8 5/8
[219]
5 1/2
[140.3]
8 7/16
[213.5]
FRONT OF CASING
TOP OF CASING
6.1
[155.7]
2 1/16
[51.6]
5.1
[130.5]
1.7
[43.5]
Ø7/8
[22.2]
ACCESSORY (2)
AIR FLOW
AIR FLOW
BOTTOM RETURN
WIDTH
AIR FLOW
KNOCK OUTS FOR
VENTING(5
PLACES)
58PHA Deluxe 4 ---Way Multi poise
58PHX Low N Ox Version
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
3. Minimum return ---air opening at furnace.
a. For 800 CFM---16---in. (406 mm) round or 14 1/2 x 12 --- in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20 ---in. (508 mm) round or 14 1/2 x 19 1/ 2 ---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22 ---in. (559 mm) round or 14 1/2 x 22 1/ 16 ---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both sideinlets,
a combination of 1 side and the bottom, or the bottom only will ensure adequate r eturn air openings for airflow requirements above 1800 CFM.
*135 size f urnace requires a 5 or 6 --- in. (127 or 152 mm) vent. U se a vent adapter between furna ce and vent stack. See Installation Instructions for complete
install ation requirements.
THERMOSTAT WIRE ENTRY
AIR FLOW
ACCESSORY
ACCESSORY
21.6
[549.5]
BOTTOM INLET
28.39
[721.2]
[736.9]
A
CABINET
WIDTH)
Ø7/8
[22.2]
Ø1/2
[12.7]
Ø7/8
[22.2]
29
6.1
[155.7]
OUTLET WIDTH
58PHA
2 1/16
[51.6]
Ø7/8
[22.2]
ACCESSORY (2)
FRONT OF CASING
1 15/16
[49.2]
2 5/16
3 7/16
[59]
[86.8]
5 7/8
[148.5]
TOP OF CASING
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
B
1.7
[43.5]
045
AIR FLOW
A
BOTTOM RETURN
WIDTH
C
TOP AND
BOTTOM FLUE
COLLAR
100
TOP OF CASING
3/4
[19.1]
D
BOTTOM
INLET WIDTH
3
100
110
Series N umber
9 9/16
[243.3]
27 3/4
[704.7]
J.BOX PROVISION
29 9/16
[750.7]
KNOCK OUTS FOR
VENTING(5
PLACES)
08
Nominal Cooling Size
(Airflow at .5 e.s.p.)
400 CFM per 12,000 Btuh)
08 --- 800 CFM
12 --- 1200 CFM
20--- 2000 CFM
FRONT OF CASING
6 13/16
[172.3]
5 7/8
[148.5]
5 5/8
[143.3]
5 7/16
[138.5]
1 15/16
[49.2]
4 13/16
[122.2]
Ø7/8
[22.2]
Ø7/8
[22.2]
ACCESSORY
VENT
CONNECTION
SIZE
8 5/8
[219]
AIR FLOW
19
[481.7]
OUTLET
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
Ø1 3/4
[44.5]
GAS ENTRY
Ø7/8
[22.2]
ACCESSORY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
SHIP WT.
LB. (KG)
7 13/16
ACCESSORY
FILTER
MEDIA
CABINET SIZE
IN. (MM)
9 11/16
[197.8]
[245.4]
14 7/8
[337.3]
(BOTH SIDES)
1 1/4
[31.8]
[25.4]
11 7/16
[290.7]
58PHA
SPECIFICATIONS
UNIT SIZE045 -- 08070--16090 --16110 --20135 --20
RATINGS AND PERFORMANCE
Input Btuh*58PHX Upflow; all 58PHA44,00066,00088,000110,000132,000
U n i t V o l t s --- H e r t z --- P h a s e115-60-1
58PHA
Operating Voltage RangeMin-Max104-127
Maximum Unit Amps8.110.811.414.214.2
Maximum Wire Length (Measure one way in Ft (M)34 (10)26 (8)25 (7)31 (9)31 (9)
Minimum Wire Size1412
MaximumFuseorCktBkrSize(Amps)**1520
Transformer (24v)40va
External ControlHeating12va
Power AvailableCooling35va
Air Conditioning Blower RelayStandard
CONTROLS
Limit ControlSPST
Heating Blower ControlSolid-State Time Operation
Burners (Monoport)23456
Gas Connection Size1/2-in. NPT
GAS CONTROLS
Gas Valve (Redundant)Mfr.White-Rodgers
Min. inlet pressure (In. W.C.)4.5 (Natural Gas)
Max. inlet pressure (In. W.C.)13.6 (Natural Gas)
Ignition DeviceHot Surface
Factory-installed orificeSize 43
BLOWER DATA
Direct-Drive Motor HP (ECM)1/23/43/411
Motor Full Load Amps6.88.88.811.511.5
RPM (Nominal)-Speeds1050--- 5
Blower Wheel Diameter x Width --- In. (mm)10 x 6
Heating7351230134518901865
Cooling10351460166520402070
( 1 7 --- 3 3 )
(254 x 152)
25--- 55
( 1 4 --- 3 1 )
11 x 8
(279 x 203)
35--- 65
( 1 9 --- 3 6 )
10 x 10
(254 x 254)
30-60
( 1 7 --- 3 3 )
11 x 11
(279 x 279)
40-70
( 2 2 --- 3 9 )
11 x 11
(279 x 279)
*Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent f or each 1000 ft. (305
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2012 Table F.4 or furnace installation instructions.
†Capacity in accordance with U.S. Government DOE test procedures.
‡Airflow shown is for bottom only return-air supply f or the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in. wide, high efficiency
media filter.
** Time---dela y type is recommended.
ICS Isolated Combustion System
4
CARRIER ACCESSORIES
DESCRIPTIONPAR T NO.045 ---08070 ---16090 --- 16110 --- 20135 ---20
FILCABXL0016XX
Media Filter Cabinet
Cartridge Media Filter
EZ Flex Media Filter with End Caps
Replacement EZ Flex Filter Media
Filter Rack Bottom Return
External Side Return Filter RackKGAFR0201ALLXXXXX
Unframed Filter 3/4---in. (19 mm)
Flue ExtensionKGAFE0112UPHXXXXX
Combustible Floor BaseKGASB0201ALLXXXXX
Downflow Vent GuardKGBVG0101DFGXXXXX
Vent Extension KitKGAVE0101DNHXXXXX
Chimney Adapter KitKGACA02014FCXXXX
Chimney Adapter KitKGACA02015FCX
N a t u r a l --- t o --- P r o p a n e C o n v e r s i o n
Kit*
P r o p a n e --- t o --- N a t u r a l C o n v e r s i o n
Kit*
Label KitKGALB0301KITXXXXX
Gas Orifice
*Factory ---author ized and field ---install ed. Gas conversion kits are CSA (AGA/CGA) recognized.
See Installation Instructions for model, altitude, and heat value usages.
58PHA
5
CARRIER ACCESSORIES
ACCESSORIES
ELECTRONIC AIR
CLEANER (EAC)
AIR PURIFIERModels GAPAAXCC1625, GAPAAXCC2025
MECHANICAL AIR
CLEANER
HUMIDIFIERModel HUM
HEAT RECOVERY
VENTILATOR
ENERGY
RECOVERY
VENTILATOR
UV LIGHTSModel UVL
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T P --- N A C , T C --- N A C
T H E R M O S T A T --N O N --PROGRAMMABLE
58PHA
F o r u s e w i t h 1 --- s p e e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r --- T P --- N H P, T C --- N H P *
F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T P --- N R H *
For use with multi--- use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity
C o n t r o l --- T P --- P R H
{
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e --- T P --- P A C
F o r u s e w i t h 1 --- s p e e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---
TP--- PHP*
T H E R M O S T A T --PROGRAMMABLE
F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e --- T P --- P R H *
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , 5 --- 2 D a y P r o g r a m m a b l e --- T P --- P A C
F o r u s e w i t h m u l t i --- s t a g e a p p l i c a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e --- T C --- P H P }
F o r m u l t i --- u s e / s t a g e c o n f i g u r a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e / Te m p e r a t u r e
a n d H u m i d i t y C o n t r o l --- T P --- P R H
{
Comfort Series™ T hree ---Zone Kit --- ZONECC3ZAC01, ZONECC3ZHP01
ZONING CONTROL
2--- Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC2KIT01 --- B
4--- Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC4KIT01 --- B
8--- Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC8KIT01 --- B
Model EACB
Models EZXCAB, FILCAB
Model HRV
Model ERV
TYPICAL WIRING SCHEMATIC
NOTE 2
FIVE WIRE
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
BLK
WHT
115-V FIELD-
SUPPLIED
DISCONNECT
GND
BLK
WHT
GND
AUXILIARY
J-BOX
C
O
N
T
R
O
L
24-V
TERMINAL
BLOCK
FURNACE
*Model HP and 2S thermostat must be field converted to air conditioner operation.
{Thermidistatt Contro
}Dual Fuel thermostat is used with furnace and heat pump application.
l control can be configured for multiple use and staging. It must be configured for each specific application.
WCRGY
W
R
G
COM
Y/Y2
NOTE 1
NOTES:Connect Y-terminal in furnace as shown for proper blower operation.
1.
2.
Some thermostats require a "C" terminal connection as shown.
3.
If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
THERMOSTAT
TERMINALS
CONDENSING
UNIT
TWO
WIRE
FIELD-SUPPLIED
DISCONNECT
GND
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
A99440
6
SEE NOTES: 1,2,4,7,8,9
UPFLOW
A02058
SEE NOTES: 1,2,3,4,7,8,9
UPFLOWDOWNFLOW
A02059
SEE NOTES: 1,2,4,5,7,8,9
A02061
58PHA
SEE NOTES:1,2,3,4,5,7,8,9
DOWNFLOW
SEE NOTES: 1,2,3,4,7,8,9
DOWNFLOW
A02063A02060
SEE NOTES: 1,2,4,5,6,7,8,9
DOWNFLOW
Ven ti ng N ot es
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC),
NFPA54/ANSI Z223.1.
2. Immediately increase to 5--in. (127 mm) vent connector outside furnace casing when 5--in. (127 mm) vent connector required, refer to
Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
Downflow Vent Guard is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4--in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete
application details.
8. Secure vent connector to furnace elbow with (2) corrosion--resistant sheet metal screws, space approximately 180_ apart.
9. Secure all other single wall vent connector joints with (3) corrosion--resistant screws spaced approximately 120_ apart. Secure Type B
vent connectors per vent connector manufacturer’s recommendations.
7
A02062
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
A02068A02070
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
58PHA
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL RIGHT
A02069
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFTHORIZONTAL LEFT
A02064
A02066
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02065
SEE NOTES: 1,2,4,5,7,8,9
A02067
8
AIR DELIVERY -- CFM (WITH FILTER)*
UNIT SIZECOLORSPEED
Gray511851145111510751035980905820720580
045 ---08
070 ---16
090 ---16
110 ---20
135 ---20
*A filter is required for each return --- air inlet. Airflow performance included 3/4 ---in. (19 mm) washable filter media such as contained in factory ---authorized accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
------ Indicates unstable operating conditions.
Yellow4920880835800755720680645605540
Blue3735685625585530490435395345295
Orange2820765725670630580545490455405
Red1650595535490430390330280235--- ---
Gray51625158515351495146014151365129512201125
Yellow41405136013201280124011951155111510701030
Blue3124012001155111010651020975935895850
Orange211901140109510501000955915870830790
Red11035985930885835785745695650600
Gray51845180017551710166515951500140012751105
Yellow41590154515001455141013651315127011801000
Blue313651320127012151170112510701025955900
Orange212251160111010601010950895830770710
Red111001030960875805730645570505425
Gray52255220521502100204019851920183517351615
Yellow41600152514651400133512751210115010801015
Blue31945189018301770171516551600154514801430
Orange21420134012801200114010651005925865790
Red11280120511401055990910840760695630
Gray52295224021852125207020051925180516701545
Yellow41725166016051545146013951340128512301170
Blue31910186518001745168516101545148514351380
Orange21630157515101435136513001245118511301065
Red11430135512851200112510751015945855800
0.10.20.30.40.50.60.70.80.91
EXTERNAL STATIC PRESSURE (In. W.C.)
58PHA
9
58PHA
A10269
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
Always Ask For
10
GUIDE SPECIFICATIONS
Gas Furnace
58PHA/PHX
GENERAL
System Description
Furnish a _________________ fixed capacity gas--fired furnace
for use with natural gas or propane (factory authorized conversion
kit required for propane); furnish cold air return plenum; furnish
external accessory media cabinet for use with accessory media filter
or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be 3rd party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will carry the CSA Blue Star label.
Unit efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage and Handling
Unit shall be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. only. Warranty certificate available upon request.
PRODUCTS
Equipment
Components shall include: slow--opening gas valve to reduce
ignition noise, regulate gas flow, with electric switch gas shut--off;
flame proving sensor, hot surface igniter, pressure switch assembly;
flame rollout switch, blower and inducer assembly, 40va
transformer; low--voltage (heating) (heating/ cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed bearings, of _______hp, and
shall be multiple--speed direct drive. shall be soft mounted to the
blower scroll to reduce vibration transmission.
Filters
Furnace may have reusable--type filters. Filter shall be _______ in
(x) _______in. (mm). An accessory high efficiency Media Filter is
available as an option. _______________ Media Filter.
Casing
Casing shall be of .030--in. (.76 mm) thickness minimum,
pre--painted steel.
Inducer Motor
Inducer motor shall be soft mounted to reduce vibration
transmission.
Draft Safeguard Switch
Draft Safeguard Switch (blocked vent safeguard) shall be factory
installed to reduce the possibility of vent gas infiltration due to a
blocked or restricted vent pipe.
Heat Exchangers
Heat exchangers shall be a 4--Pass 20 gage aluminized steel of
fold--and--crimp sectional design when applied operating under
negative pressure.
Controls
Control shall include a micro--processor based integrated electronic
control board with at least 11 service troubleshooting codes
displayed via enhanced flashing LED diagnostic light on the
control, a self--test feature that checks all major functions of the
furnace within one minute, and a replaceable automotive--type
circuit protection fuse. Multiple operational settings available
including, separate blower speeds for heating, cooling and
continuous fan. Continuous fan speed may be adjusted from the
thermostat. Features will also include temporary reduced airflow in
the cooling mode for improved dehumidification when a
Thermidistatt Control is selected as the thermostat.
_________ in. (mm); height_________in. (mm) (casing only).
Height shall be_________in. (mm) with A/C coil and
____________ in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be_________AWG; maximum fuse size
or circuit breaker shall be __________Amps.
Special Features
Refer to section of the product data sheet identifying accessories
and descriptions for specific features and available enhancements.
58PHA
11
58PHA
Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231Edition Date: 08/13
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: 58PHA ---08PD
Replaces: 58PHA --- 07PD
12
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.