58PHA/PHX PERFORMANCE™ BOOST 80
4 --- WAY M U LTI P O I S E
INDUCED---COMBUSTION GAS FURNACE
Input Capacities: 45,000 thru 135,000 Btuh
Series 110/120
Product Data
58PHA/PHX furnaces are approved for use with natural or propane
gas, and the 58PHX is approved for use in Low NOx Air Quality
Management Districts.
STANDARD FEATURES
S ECM Blower Motor included
S QuieTecht noise reduction system
S SmartEvapt—Humidity control when using a
Thermidistatt Control
S ComfortFant—adjustable constant fan speed from the
thermostat
A10251
THE CARRIER PERFORMANCEt BOOST 80
GAS FURNACE
The 58PHA/PHX 4--way Multipoise Gas Furnaces offer deluxe
features not found in other single--stage 80% gas furnaces. The
ECM motor and Carrier’s control logic combine to provide a
SEERBOOSTofupto1.5points.*Carrier’sQuieTecht noise
reduction system makes the Performancet Boost 80 an incredibly
quiet induced--draft gas furnace.
The gas furnace control system provides a dehumidification mode,
a motor speed selection for continuous fan operation selectable at
the thermostat, and fault code storage in the event of power
outages. Applications are easy with 4--way multipoise design,
through--the--furnace downflow venting, 13 different venting
options, and a design for easy service access. An inner blower door
is provided for tighter sealing in sensitive applications. The
S Microprocessor based control center
Enhanced diagnostics with LED and reflective sight glass.
Stores fault codes during power outages
Adjustable heating air temperature rise
Adjustable cooling airflow
Dehumidification selection for summer--time cooling
S 4--way Multipoise furnace, 13 vent applications
S Compact design -- only 33--1/3 in. (847 mm) tall
S Power Heat SiNt Igniter
S Draft safeguard switch to ensure proper furnace venting
S Insulated blower compartment
S Inner door for tighter sealing
S Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In.
Water Gauge with all present air inlets and air outlet sealed.
S HYBRID HEAT Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Residential installations eligible for consumer financing
through the Retail Credit Program
*as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil ---only rating when paired with selected Carrier evaporator coils.
1

FURNACE COMPONENTS
INDUCER MOTOR
ASSEMBLY
PRESSURE
SWITCH
FLUE COLLECTOR
BOX
GAS VALVE
58PHA
MANUAL RESET
LIMIT SWITCHES
HOT SURFACE
IGNITOR
VENT
ELBOW
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
BLOCKED VENT
SWITCH
FLAME
SENSOR
GAS MANIFOLD
GAS BURNER
BLOWER
DOOR SAFETY
SWITCH
FURNACE
CONTROL
BOARD
BLOWER AND
MOTOR
CAPACITOR/
POWER CHOKE
A10314
NOTE: The 58PHA/PHX Furnaces are factory shipped for use with natural gas. These furnaces can be field--converted for propane gas with
a factory--authorized and listed accessory conversion kit.
2

MODEL NUMBER NOMENCLATURE
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø7/8
[22.2]
ACCESSORY (2)
KNOCK OUTS FOR
VENTING(5
PLACES)
58PHA Deluxe 4 ---Way Multi poise
58PHX Low N Ox Version
Input Rates
045 --- 44,000 Btuh
070 --- 66,000 Btuh
090 --- 88,000 Btuh
110 --- 110,000 Btuh
135 --- 132,000 Btuh
DIMENSIONS
5.1
[130.5]
5 15/16
[150.7]
5 1/2
[140.3]
8 7/16
[213.5]
9 7/8
[250.7]
27 3/4
[704.7]
33 1/4
[843.9]
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
3. Minimum return ---air opening at furnace.
a. For 800 CFM---16---in. (406 mm) round or 14 1/2 x 12 --- in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20 ---in. (508 mm) round or 14 1/2 x 19 1/ 2 ---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22 ---in. (559 mm) round or 14 1/2 x 22 1/ 16 ---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both sideinlets,
a combination of 1 side and the bottom, or the bottom only will ensure adequate r eturn air openings for airflow requirements above 1800 CFM.
FURNACE
SIZE
045--- 08 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12--- 11/16 (322) 4 (102) 104 (47) 16 (406)
070--- 16 17--- 1/2 (445) 15--- 7/8 (403) 11--- 9/16 (294) 16 (406) 4 (102) 126 (57) 16 (406)
090--- 16 21 (533) 19 --- 3/8 (492) 13--- 5/16 (338) 19--- 1/2 (495) 4 (102) 140 (64) 20 (508)
110--- 20 21 (533) 19 --- 3/8 (492) 13--- 5/16 (338) 19--- 1/2 (495) 4 (102) 152 (69) 20 (508)
135--- 20 24--- 1/2 (622) 22--- 7/8 (581) 15--- 1/16 (383) 23 (584) 4 (102)* 163 (74) 24 (610)
*135 size f urnace requires a 5 or 6 --- in. (127 or 152 mm) vent. U se a vent adapter between furna ce and vent stack. See Installation Instructions for complete
install ation requirements.
THERMOSTAT WIRE ENTRY
AIR FLOW
ACCESSORY
ACCESSORY
21.6
[549.5]
BOTTOM INLET
28.39
[721.2]
[736.9]
A
CABINET
WIDTH)
Ø7/8
[22.2]
Ø1/2
[12.7]
Ø7/8
[22.2]
29
6.1
[155.7]
OUTLET WIDTH
58PHA
2 1/16
[51.6]
Ø7/8
[22.2]
ACCESSORY (2)
FRONT OF CASING
1 15/16
[49.2]
2 5/16
3 7/16
[59]
[86.8]
5 7/8
[148.5]
TOP OF CASING
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
B
1.7
[43.5]
045
AIR FLOW
A
BOTTOM RETURN
WIDTH
C
TOP AND
BOTTOM FLUE
COLLAR
100
TOP OF CASING
3/4
[19.1]
D
BOTTOM
INLET WIDTH
3
100
110
Series N umber
9 9/16
[243.3]
27 3/4
[704.7]
J.BOX PROVISION
29 9/16
[750.7]
KNOCK OUTS FOR
VENTING(5
PLACES)
08
Nominal Cooling Size
(Airflow at .5 e.s.p.)
400 CFM per 12,000 Btuh)
08 --- 800 CFM
12 --- 1200 CFM
20--- 2000 CFM
FRONT OF CASING
6 13/16
[172.3]
5 7/8
[148.5]
5 5/8
[143.3]
5 7/16
[138.5]
1 15/16
[49.2]
4 13/16
[122.2]
Ø7/8
[22.2]
Ø7/8
[22.2]
ACCESSORY
VENT
CONNECTION
SIZE
8 5/8
[219]
AIR FLOW
19
[481.7]
OUTLET
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
Ø1 3/4
[44.5]
GAS ENTRY
Ø7/8
[22.2]
ACCESSORY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
SHIP WT.
LB. (KG)
7 13/16
ACCESSORY
FILTER
MEDIA
CABINET SIZE
IN. (MM)
9 11/16
[197.8]
[245.4]
14 7/8
[337.3]
(BOTH SIDES)
1 1/4
[31.8]
[25.4]
11 7/16
[290.7]
58PHA

SPECIFICATIONS
UNIT SIZE 045 -- 08 070--16 090 --16 110 --20 135 --20
RATINGS AND PERFORMANCE
Input Btuh* 58PHX Upflow; all 58PHA 44,000 66,000 88,000 110,000 132,000
Nonweatherized ICS 58PHX Downflow/Horizontal 42,000 63,000 84,000 105,000 126,000
Output Capacity (Btuh)† 58PHX Upflow; all 58PHA 36,000 53,000 72,000 90.000 107.000
Nonweatherized ICS 58PHX Downflow/Horizontal 34,000 51,000 69,000 86,000 102,000
AFUE† 80.0 80.0 80.0 80.0 80.0
Certified Temperature Rise Range --- ° F (° C) 30-60
Certified External Static Pressure Heat/Cool 0.10/0.50 0.12/0.50 0.15/0.50 0.20/0.50 0.20/0.50
Airflow CFM‡
ELECTRICAL
U n i t V o l t s --- H e r t z --- P h a s e 115-60-1
58PHA
Operating Voltage Range Min-Max 104-127
Maximum Unit Amps 8.1 10.8 11.4 14.2 14.2
Maximum Wire Length (Measure one way in Ft (M) 34 (10) 26 (8) 25 (7) 31 (9) 31 (9)
Minimum Wire Size 14 12
MaximumFuseorCktBkrSize(Amps)** 15 20
Transformer (24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control Solid-State Time Operation
Burners (Monoport) 2 3 4 5 6
Gas Connection Size 1/2-in. NPT
GAS CONTROLS
Gas Valve (Redundant) Mfr. White-Rodgers
Min. inlet pressure (In. W.C.) 4.5 (Natural Gas)
Max. inlet pressure (In. W.C.) 13.6 (Natural Gas)
Ignition Device Hot Surface
Factory-installed orifice Size 43
BLOWER DATA
Direct-Drive Motor HP (ECM) 1/2 3/4 3/4 1 1
Motor Full Load Amps 6.8 8.8 8.8 11.5 11.5
RPM (Nominal)-Speeds 1050--- 5
Blower Wheel Diameter x Width --- In. (mm) 10 x 6
Heating 735 1230 1345 1890 1865
Cooling 1035 1460 1665 2040 2070
( 1 7 --- 3 3 )
(254 x 152)
25--- 55
( 1 4 --- 3 1 )
11 x 8
(279 x 203)
35--- 65
( 1 9 --- 3 6 )
10 x 10
(254 x 254)
30-60
( 1 7 --- 3 3 )
11 x 11
(279 x 279)
40-70
( 2 2 --- 3 9 )
11 x 11
(279 x 279)
* Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent f or each 1000 ft. (305
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2012 Table F.4 or furnace installation instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return-air supply f or the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in. wide, high efficiency
media filter.
** Time---dela y type is recommended.
ICS Isolated Combustion System
4