,_ WARNING
Withtoday'shomesbeingbuilt"tighter"for improvedenergyefficiency,manystatesandprovincesnow requiremechanicalventilationas partof the buildingcode.Inthesetighthomes,contaminantsincluding radon,formaldehyde,householdchemicals,smokeandotherodorscanbuildupto levelsthatexceedsafe
thresholds. TheFreshAirVentsystemcontrollerprovidestheuserwith adjustableflexibilityto preciselysetupand
managefreshairto reduceor dilutethevolumeof "stale" air in thehome- at anaffordablepricepoint. Thesystemallowsfreshairto beintroducedthroughouttheyear,exceptin extremetemperatureand
humidityconditions.Thecontrollerdoesnotallowthe damperto openwhenoutdoortemperaturesare aboveIO0°F(38°C),belowO°F(-17°C),orif indoorhumiditylevelsareabove55%,inorderto prevent conditionsthat wouldhavea negativeimpactoncomfort.
Workingwithyour FreshAirVentDampersystemtheVentilationControllertellswhen,andhowlong,it shouldoperate.It doesthis throughcontinuousmonitoringofyourindoorhumidity,alongwith theoutdoor temperature.Itthenoperatesaccordingtothetimersettingsasadjustedto yourpreference,or localcodes ortheHVACindustryrecognizedASHRAE62.2-2007guidelines.
PleaseNete: TheVentilationControllerwill notworkif the outdoorfreshairintakeventis cloggedwith debris.Cleanthisregularly.Alsopleasemakesureto notobstructorcloseoffthereturnairgrillesof your heatingsystemin ordertoprotectyourfurnace.
YourVentilationControlleris installedinthe returnductofyourfurnaceorheatpump.Therearetwo adjustable settings,thecycle time andtheactualventilationtime withineachcycle.Here'showthisworks.Ifthe cycletime issetto 2 hoursandthecontrollerknobissetto40minutes,youwill get40minutesofventilation everytwo hours.
Yourventilationsetting,whichis40minutesevery2hoursinthis example,canbemetbytheoperationof yourheatingorcoolingsystem.Orif weatherconditionsarecomfortableorthethermostatisonsetback,the Controlleritselfwill turnonthe furnaceblowerto providethe40minutes.
YourInstallershouldhavealreadysetthisfor you.Thiswill likelybeatthe recommendedfactorysetting oftwo hours.
Ifthereisaneedto changethis,consultyourdealer.
Theknobonthefrontof the Controlleris usedtosetthe ventilationtime withinthecycleintervalsetinStepA.
TheTESTsettingis usedto checkthe deviceforproper
installation.Itisnotfor normaloperation,it will only
activatetheControllerfor 1minute.Donotleavetheknob atTEST,it doesnotallow actualoperatingtime.
TheOFFsettingcutsoff all circuitactivation,while 0
leavesthe circuitelectricallyactivebut itwill notoperate. Thedialislabeledin 15minuteincrements,butcanbesetto anyestimatedvaluewithin 5minuteaccuracy.TheInstaller
will havealreadysetthisfor youaccordingto the sizeand numberofoccupantsforyourhome.Ifyoufeellikeyouneed moreorlesstime,turntheknobto a maximumof5minutes
eitherway.Seehowthis worksbeforeadjustingagain.
60
3O
0
MINUTES PER CYCLE
AsinstalledyourVentilationControllerwill useinputmeasurementsofOutdoorTemperatureandIndoor Humidity,plustheadjustedtimesettings,tocomputeactivation.Thetemperatureoutdoorsismeasured with a sensoratthefreshair ductinlet.IndoorHumidityismeasuredinthe returnductwith asensorbuilt intotheController.Incoordinationwith thetimersettings,theControllerthenoperatesaccordingto the temperatureandhumiditylimitsshownin Diagram1below.
..=.
o,.
oo
15% 25% 35% 45% 55% 65%
iNDOOR RELATIVE HUMiDiTY
SectionA:Ventilationpreventedduetotemperatureextremesand/orhighindoorhumidity. SectionB:Ventilationperthetimersettings. SectionC:Ventilationoptionalif required.Consultyourdealerforrecommendations.
Ifthe "TIMEONLY"resistorisusedinsteadof theOutdoorTemperatureSensor,the Controller'soperationis determinedbythetimersettingsasadjustedonly.TheControllerwill notlimit operationbasedon the temperatureandhumiditylimitsasshownin Diagram 1.Thisfeatureis importantfor areaswithmoderate
climates. Ifa jumperwireis usedinplaceof the OutdoorTemperatureSensor,theControllerwill disregardthe
temperaturesettingandbaseventilationoperationontheindoorrelativehumidityandthe timersettings only.Inthis modetheControllerwon'tallowventilationif the indoorRHrisesabove55%.