Carrier ERVCCSHB, ERVCCLHA, ERVCCSVB User Manual

ERVCCLHA, ERVCCSHB, ERVCCSVB Energy Recovery Ventilator
Owner’s Manual
Fig. 1 -- ERVCCLHA Horizontal Unit
A07619
A05229
Fig. 2 -- ERVCCSHB Unit (Side Port)
A05330
Fig. 3 -- ERVCCSVB Unit (Top Port)
NOTE TO EQUIPMENT OWNER:
ENERGY RECOVERY VENTILATOR
Model # _____________________________________
Serial # ______________________________________
ACCESSORIES (List type and model #)
_____________________________________________ _____________________________________________
_____________________________________________
_____________________________________________
NOTE TO INSTALLER:
This manual must be left with the equipment owner.
INSTALLATION INFORMATION:
Date Installed ________________________________
DEALERSHIP CONTACT INFORMATION:
Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________
SAFETY CONSIDERATIONS
Recognize safety information. This is the safety--alert symbol When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
UNIT OPERATION
ERV with OneToucht Control
ERV
MAX MIN
INTERMITTENT
Press “PUSH” until the desired ventilation operation is selected. There are three selections: High, Low, Intermittent. The power indicator light indicates which mode has been selected.
High — This mode is recommended for the removal of excess pollutants and humidity. The ventilator will operate at its maximum speed continuously. The power indicator light will be lit red when this mode is selected.
Low — This mode is recommended for normal daily operation. The ventilator will operate at its minimum speed continuously. The power indicator light will be lit yellow when this mode is selected.
Intermittent — Thismode isrecommended whentheinsideairistoo dryin the heatingseasonor too humidin thecoolingseason.The ven­tilator will operate atits minimum speed for 20 minutes per hourand be off for 40 minutes per hour. The power indicator light will be lit green when this mode is selected.
Off — To turn the ventilator off, press “Push” until the power indica­tor light is turned off.
A07622
ERV with Latent Control
A07621
Your ERV isdesigned tooperateas an integral partof yourtotalheat­ing and cooling system.
Low Exchange Mode—If the relative humidity inside the building is lower than selected, air exchange would occur with the outside at high speed. If the relativehumidity level inside the building is higher than selected,air exchange would occur outside at low speed.This en­sures continuous air exchange for constant air quality.
Intermittent Mode—If the relative humidity inside the building is higher than selected, no air exchange would occur, and the system would turn off. If the relative humidity inside the building is lower than selected, air exchange would occur with outside at high speed. Thismodeis idealfor maintainingtheproperhumiditylevelwhenthe continuous mode cannot.
!
WARNING
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Before servicing system, always turn off main power to system. Turn off accessory heater power if applicable. There may be more than 1 disconnect switch.
!
CAUTION
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury. Although special care has been taken to minimize sharp edges
in the construction of your unit, be extremely careful when handling parts or reaching into the unit.
2