50TFF-4SB
50TFF004-014
SINGLE-PACKAGE ELECTRIC
COOLING UNITS WITH
FIELD-INSTALLED ELECTRIC HEAT
— PERFORMANCE DATA
— CERTIFIED DIMENSION PRINTS
— CERTIFIED ROOF CURB
DIMENSION PRINTS
Form 50TFF-4SB Replaces: 50TFF-3SB
© Copyright 2005 Carrier Corporation • Syracuse, New York 13221
Printed in U.S.A. 11-05 Catalog No. 04-51500003-01
Date: Supersedes:
SINGLE-PACKAGE ELECTRIC
FIELD-INSTALLED ELECTRIC HEAT
50TFF004-014
COOLING UNITS WITH
50TFF
JOB NAME: LOCATION:
BUYER: BUYER P.O. # CARRIER #
UNIT NUMBER: MODEL NUMBER:
UNIT DESIGNATION:
PERFORMANCE DATA CERTIFIED BY: DATE:
DESCRIPTION
Units are a single piece, electric cooling unit, with a low profile, pre-wired, tested and charged at the factory.
The units have the capability for convertible supply and return openings and are intended for installation on an
accessory curb (ordered separately), or for slab mounting (for horizontal duct connections). Units are designed
to accept a field-installed economizer, enthalpy control, manual or two-position outside-air damper, roof curb,
as well as many choices of field-installed electric heat. Refer to accessory chart below for full listing.
FEATURES
• Standard one-year full product warranty.
• Five-year protection plan for the motor-compressor.
• Outdoor ambient cooling operation from 25 F (–4 C) to 115 F (46 C).
• Units are tested and certified by ARI and certified by UL and CSA.
Factory-run test printout included in each rooftop.
• 24-volt control circuit, with resettable breaker.
• Two-inch disposable-type return air filters in dedicated rack.
• Hermetic compressor on independent circuit with internal line break and
overload protection, self-lubricating with internal discharge muffler.
• Scroll compressor with internal overload protection (50TFF007 and
50TFF014).
• Each refrigerant circuit contains a filter drier to trap dirt and particles.
• Single compressor on 3 to 6 ton units.
• Dual compressors on 7
• Two-speed direct drive evaporator fan on all units except size 007 which
is belt driven. Adjustable belt drive fans are optional on all sizes.
• Non-corrosive condensate pan with self-draining sloping design with
both bottom and side drain connections.
1
/2to 121/2ton units.
• Thru-the-bottom power control entry capability.
• Evaporator and condenser coils constructed of aluminum fins mechanically bonded to seamless copper tubes.
• Single point electrical connections.
• Direct-drive propeller condenser fan totally enclosed with permanently
lubricated bearings.
• Pre-painted, insulated cabinet with primer inner panels, certified 500-hr
salt spray test and non-corrosive screws.
• Large, easily removable panels provide ready access to unit components
for rapid removal or maintenance.
• Filter access door for filter access and maintenance that requires no tools.
• Fixed orifice metering device precisely controls refrigerant flow to each
circuit individually.
• Reliable accurate control circuit with color coded wires and easy accessible terminal board.
• Loss of charge, freeze protection, and high pressure switches standard.
• Cooling units with field-installed electric heat with accessory singlepoint electrical kit have single-point electrical power connection — UL
approved.
Rev.:
-4SB
PERFORMANCE DATA
COOLING
Net Total Cap. _____________________________________________ Btuh
Net Sensible Cap. __________________________________________ Btuh
Compressor Power Input _____________________________________ kW
_______________________________________ F Outdoor Air Temperature
Indoor Entering Air db _______________ F wb _________________ F
Cfm ___________________ Ext. Static Pressure ______________ in. wg
EER _________________________________________________________
ELECTRICAL DATA
Power Supply to Unit _____________ Volts _________________ Phase ___________________ Hz
Minimum Circuit Amps ________________ Maximum Overcurrent Protection (Fuse only)____________
HEATING
Heating Capacity
kW ________________________________________________________
Btuh _______________________________________________________
OPERATING WEIGHT
_________ lb (unit) _____________ lb (curb)
2
OPTIONS AND ACCESSORIES
FACTORY-INSTALLED OPTIONS
EconoMi$er IV with Controller
EconoMi$er2 with 4-20 mA Actuator Only
(PremierLink™ or 3rd Party EMS System
Control)
Copper/Copper Coils — Evaporator,
Condenser, Both
Pre-Coated Condenser Coil
E-Coat (Post-Coated) Condenser Coil
FIELD-INSTALLED ACCESSORIES
EconoMi$er IV with Controller
EconoMi$er2 with 4-20 mA Actuator and No Microprocessor — Vertical or Horizontal
25% Open Two-Position Damper
25% Open Manual Air Damper
50% Open Manual Outdoor Air Damper
100% Open Two-Position Damper
Outdoor Air/Return Air Temperature
Sensor
Outdoor Air/Return Air Enthalpy Sensor
Roof Curb (14 or 24-in. Height)
Thru-the-Bottom/Roof Curb Electrical
Connection Kit
Time Guard II Compressor Anti-Cycle Control
Condenser Coil Hail Guard
Condenser Coil Grille
Room Temperature Sensor
Non-Fused Disconnect Switch (factory wired)
115-Volt Convenience Outlet (factory wired, load side)
PremierLink Control
25% Manual Air Damper
Alternate Motor and Drive
(except 007 and 009 size)
High-Static Motor (except size 014)
Novar 3051 Control
PremierLink Control
CO2Sensor (IAQ Control)
Power Exhaust
Horizontal Power Exhaust Module (Single Fan)
–20 F Motormaster® Low Ambient Control Kit
Programmable Setback Thermostat
Electrical Mechanical Thermostat and Subbase
Indoor Fan/Filter Status Indicator
Electric Resistance Heat Coils
62AQ Energy$Recycler™ Mounting Kit
62AQ Energy$Recycler Supply Air Blower
62AQ Energy$Recycler 460-V Transformer
62AQ Energy$Recycler 575-V Transformer
Humidistat
Light Commercial Thermidistat™ Device
UV-C Lamps
Other ____________________
BLANKET QUOTE CONTROLS
115-Volt Field Powered GFI Convenience Outlet
(line side)
115-Volt GFI Convenience Outlet (field powered)
E-Coated Aluminum/Copper Condenser and Evaporator Coils
Fused Disconnect
Hinged Acess Panels
Lockout of High Fire Stage for Heating
CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE
Low Ambient Controller (Motormaster® I)
Smoke Detector — Return Air
Smoke Detector — Return and Supply Air
Smoke Detector — Supply Air
Split Power (transfer switch NOT included)
UV-C Lamps (installed and powered with door interlock
switch and disconnect switch)
3