Carrier 38MHRQ24A3, 40MHHQ243 User Manual

10 Year Parts & Compressor Warranty
When Registered Within 90-Days Of Installation
NOMINAL CAPACITY SEER EER HSPF INDOOR OUTDOOR
LIQUID X SUCTION
MIN LINE
LENGTH
PRE
CHARGE
LENGTH
MAX LINE
LENGTH
ADDITIONAL
CHARGE
MAX LIFT
MCA / MOCP
BASEPAN
HEATER
Warranty
With
Registration
WIRELESS
REMOTE
WIRED
CONTROLLER
9,000/ Gray ID
30.5
15.8 10.3
40GRQB09B--3 38GRQB09---3
1/4 X 1/2 10' 25' 82' .20 Oz/Ft. 33' 12A/15A Factory Installed 10 YEARS Included N/A
9,000/White ID
30.5
15.8 10.3
40GRQB09H--3 38GRQB09---3
1/4 X 1/2 10' 25' 82' .20 Oz/Ft. 33' 12A/15A Factory Installed 10 YEARS Included N/A
12,000/Gray ID
23.0
12.8 10.3
40GRQB12B--3 38GRQB12---3
1/4 X 1/2 10' 25' 82' .20 Oz/Ft. 33' 13A/20A Factory Installed 10 YEARS Included N/A
12,000/White ID
23.0
12.8 10.3
40GRQB12H--3 38GRQB12---3
1/4 X 1/2 10' 25' 82' .20 Oz/Ft. 33' 13A/20A Factory Installed 10 YEARS Included N/A
18,000/Gray ID
21.0
12.5 10.3
40GRQB18B--3 38GRQB18---3
1/4 X 5/8 10' 25' 82' .20 Oz/Ft. 33' 19A/30A Factory Installed 10 YEARS Included N/A
18,000/White ID
21.0
12.5 10.3
40GRQB18H--3 38GRQB18---3
1/4 X 5/8 10' 25' 82' .20 Oz/Ft. 33' 19A/30A Factory Installed 10 YEARS Included N/A
PerformanceTM High Wall 1:1 Heat Pump
9,000 - 115Volt 24.5
15.0 11.2
40MAQB09B--1 38MAQB09R--1
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 15A/20A Factory Installed 10 YEARS Included Optional
12,000 - 115 Volt 22.0
13.0 10.2
40MAQB12B--1 38MAQB12R--1
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 15A/20A Factory Installed 10 YEARS Included Optional
30,000
19.8
11.5 9.4
40MAQB30B--3 38MAQB30R--3
3/8 X 5/8 10' 25' 164' .32 Oz/Ft. 82' 20A/30A Factory Installed 10 YEARS Included Optional
36,000
16.0
8.6 8.5
40MAQB36B--3 38MAQB36R--3
3/8 X 5/8 10' 25' 164' .32 Oz/Ft. 82' 25A/35A Factory Installed 10 YEARS Included Optional
9,000
25.0
14.5 11.2
40MAQB09B--3 38MAQB09R--3
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Optional
12,000
22.5
12.5 12.0
40MAQB12B--3 38MAQB12R--3
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Optional
18,000
20.0
12.5 10.3
40MAQB18B--3 38MAQB18R--3
1/4 X 1/2 10' 25' 98' .16 Oz/Ft. 65' 18A/25A Factory Installed 10 YEARS Included Optional
24,000
20.5
13.0 10.3
40MAQB24B--3 38MAQB24R--3
3/8 x 5/8 10' 25' 98' .32 Oz/Ft. 65' 20A/30A Factory Installed 10 YEARS Included Optional
PerformanceTM Cassette 1:1 Heat Pump
9,000
20.0
13.0 10.8
40MBCQ09---3 38MAQB09R--3
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Optional
12,000
19.5
12.5 10.6
40MBCQ12---3 38MAQB12R--3
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Optional
16,000
20.0
12.5 10.5
40MBCQ18---3 38MAQB18R--3
1/4 X 1/2 10' 25' 98' .16 Oz/Ft. 32' 18A/25A Factory Installed 10 YEARS Included Optional
PerformanceTM Console 1:1 Heat Pump
9,000
20.0
12.5 11.6
40MBFQ09---3 38MAQB09R--3
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Optional
12,000
19.4
12.5 10.5
40MBFQ12---3 38MAQB12R--3
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Optional
PerformanceTM Ducted 1:1 Heat Pump
9,000
19.0
13.0 11.1
40MBQB09D--3 38MAQB09R--3
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Included
11,000
19.0
12.5 10.5
40MBQB12D--3 38MAQB12R--3
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 9A/15A Factory Installed 10 YEARS Included Included
16,000
19.6
12.5 11.0
40MBDQ18---3
38MAQB18R--3
1/4 X 1/2 10' 25' 98' .16 Oz/Ft. 65' 18A/25A Factory Installed 10 YEARS Included Included
23,000
20.5
12.5 12.5
40MBDQ24---3 38MAQB24R--3
3/8 X 5/8 10' 25' 98' .32 Oz/Ft. 65' 20A/30A Factory Installed 10 YEARS Included Included
36,000
16.5
9.0 11.5
40MBDQ36---3 38MBRQ36A--3
3/8 X 5/8 10' 25' 213' .43 Oz/Ft. 82' 30A/50A Factory Installed 10 YEARS Included Included
48,000
17.4
9.2 10.3
40MBDQ48---3 38MBRQ48A--3
3/8 X 5/8 10' 25' 213' .43 Oz/Ft. 82' 35A/50A Factory Installed 10 YEARS Included Included
Installation Note :
ComfortTM High Wall 1:1 Heat Pump
9,000 - 115Volt 16.0
11.0 9.0
40MHHQ09---1 38MHRQ09A--1
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 13A/20A N/A 10 YEARS Included Optional
12,000 - 115 Volt 16.8
10.8 9.0
40MHHQ12---1 38MHRQ12A--1
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 13A/20A N/A 10 YEARS Included Optional
9,000
16.0
10.5 9.0
40MHHQ09---3 38MHRQ09A--3
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 8A/15A N/A 10 YEARS Included Optional
12,000
17.0
10.9 9.0
40MHHQ12---3 38MHRQ12A--3
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 10A/15A N/A 10 YEARS Included Optional
17,000
16.0
11.0 9.0
40MHHQ18---3 38MHRQ18A--3
1/4 X 1/2 10' 25' 98' .16 Oz/Ft. 65' 15A/20A N/A 10 YEARS Included Optional
22,000
16.8
10.5 9.0
40MHHQ24---3 38MHRQ24A--3
3/8 X 5/8 10' 25' 164' .32 Oz/Ft. 65' 18A/25A N/A 10 YEARS Included Optional
ComfortTM High Wall 1:1 Cooling Only
9,000 - 115Volt 16.6
11.6 N/A
40MHHC09---1 38MHRC09A--1
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 13A/20A N/A 10 YEARS Included Optional
12,000 - 115 Volt 17.3
10.7 N/A
40MHHC12---1 38MHRC12A--1
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 13A/20A N/A 10 YEARS Included Optional
9,000
16.0
10.6 N/A
40MHHC09---3 38MHRC09A--3
1/4 X 3/8 10' 25' 82' .16 Oz/Ft. 32' 7A/15A N/A 10 YEARS Included Optional
12,000
16.5
10.8 N/A
40MHHC12---3 38MHRC12A--3
1/4 X 1/2 10' 25' 82' .16 Oz/Ft. 32' 7A/15A N/A 10 YEARS Included Optional
18,000
17.0
10.5 N/A
40MHHC18---3 38MHRC18A--3
1/4 X 1/2 10' 25' 98' .16 Oz/Ft. 65' 11A/15A N/A 10 YEARS Included Optional
24,000
17.5
10.9 N/A
40MHHC24---3 38MHRC24A--3
3/8 X 5/8 10' 25' 164' .32 Oz/Ft. 65' 16A/25A N/A 10 YEARS Included Optional
Control Wiring
Kit Number
KSAIC0101115 KSAIC0101230
01-DLS-026-01
1 to 1 PerformanceTM &
ComfortTM Series ONLY
Mid-Tier High Wall
SEN-INS-CAR-03
208/230-1
© Carrier Corporation 2017
SUBJECT TO CHANGE WITHOUT NOTICE
07/2017
Sensibo®
Mid-Tier Ducted
SEN-INS-CAR-01
24 Volt Interface
Volt-Ph
Mid-Tier Cassette & Floor Console
SEN-INS-CAR-02
115-1
PerformanceTM Ducted 1:1 Heat Pump
Heating Capacity: 36K = 71% & 48K = 75% of Rated Capacity @ 5° F
The 38MBRQ Ducted systems require a shielded, stranded communication circuit between the indoor and outdoor units
Standard Heating Capacity Systems
* Warranty registration required except in CA and Quebec. In Commercial applications, Warranty is 7 Years P/C with Registration
See installation Instructions 14/3 Stranded Wire with Ground is the required Control wiring between the indoor and outdoor units
High Heating Systems - 100% of Rated Capacity @ 5° F
Single Zone Quick Reference Guide
Ductless Systems
*This Sheet is not intended to replace the Installation Instructions. It is a reference guide only. Always reference the Installation Instructions*
Infinity® High Wall 1:1 Heat Pump
High Heating Systems - 100% of Rated Capacity @ 0° F
Standard Heating Capacity Systems
PerformanceTM High Wall 1:1 Heat Pump
High Heating Systems - 100% of Rated Capacity @ 5° F
High Heating Systems - 100% of Rated Capacity @ 5° F
Ceiling Cassette Grille 40MBQB01C--- Required and Sold Separately
High Heating Systems - 100% of Rated Capacity @ 5° F
@ 5° F @ -13° F @ -22° F
38MGRQ18B--3 2
13,900 / 73% 6,540 / 34% 5,520 / 29%
10' 82' 131' 49' 49' 18A 25A
38MGRQ24C--3 3
23,000 / 100% 17,590 / 77% 13,850 / 60%
10' 98' 197' 74' 49' 25A 35A
38MGRQ30D--3 4
28,000 / 100% 20,650 / 74% 16,700 / 60%
10' 115' 263' 98' 49' 30A 45A
38MGRQ36D--3 4
36,000 / 100% 27,690 / 77% 23,030 / 64%
10' 115' 328' 123' 65' 35A 50A
38MGRQ48E--3 5
36,000 / 75% 28,050 / 58% 23,330 / 49%
10' 115' 328' 123' 65' 35A 50A
9+9
9+12
12+12
9+9 12+12 9+9+9 9+12 12+18 9+9+12 9+18 18+18 9+9+18
9+9+9
9+9 12+12 9+9+12 9+12 12+18 9+9+18 9+18 12+24 9+12+12 9+24 18+18 9+12+18 9+18 12+12 9+9+9 9+24 12+18 9+9+12
12+24 9+9+18 18+18 9+9+24 18+24 9+12+12 24+24 9+12+18
9+18 9+9+9
9+24 9+9+12 12+12 9+9+18 12+18 9+9+24 12+24 9+12+12 18+18 9+12+18 18+24 9+12+24 24+24 9+18+18
9+18+24
9+12+12+12+12
01-DLS-026-01
18+18+24
9+9+18+24
12+12+18+18
© Carrier Corporation 2017
SUBJECT TO CHANGE WITHOUT NOTICE
07/2017
12+24+24
9+9+12+24
12+12+12+18
9+9+9+12+12
9+12+12+12+18
18+18+18
9+9+18+18
12+12+12+24
9+9+9+12+18
12+12+12+12+12
12+12+24
9+9+9+24
9+12+18+18
9+9+9+9+12
9+9+12+12+12
38MGRQ48E--3
9+24+24
9+9+9+9
9+12+12+12
12+12+12
9+9+9+12
9+12+12+18
12+12+18
9+9+9+18
9+12+12+24
12+18+18
9+9+12+12
9+18+18+18
9+9+9+9+18
9+9+12+12+18
12+18+24
9+9+12+18
12+12+12+12
9+9+9+9+24
18+18+18
9+9+12+12
9+18+18+18
12+12+18
18+18+24
9+9+12+18
12+12+12+12
9+9+9+9+9
9+9+9+18+18
38MGRQ36D--3
9+12+24
12+12+24
9+9+9+9
9+12+12+12
9+18+18
12+18+18
9+9+9+12
9+12+12+18
9+18+24
12+18+24
9+9+9+18
9+12+12+24
9+24+24
12+24+24
9+9+9+24
9+12+18+18
9+9+12+24
12+12+12+18
9+9+18+18
12+12+12+24
9+9+18+24
12+12+18+18
12+12+12
9+9+9+9
9+9+12+18
12+12+18
9+9+9+12
9+12+12+12
12+18+18
9+9+9+18
12+12+12+12
38MGRQ24C--3
9+12+12
12+12+12
38MGRQ30D--3
9+18+18
12+12+12
12+12+24
9+9+12+12
Outdoor Models
Two Zones
Three Zones
Four Zones
Five Zones
38MGRQ18B--3
40MBDQ24---3
Grille Part # 40MBQB01C---
40MAQB24B--3
40MHHQ24---3
Rated Combinations
40MBQB12D--3
40MBCQ12---3
40MAQB12B--3
40MHHQ12---3
40MBFQ12---3
40MBDQ18---3
40MBCQ18---3
40MAQB18B--3
40MHHQ18---3
Ducted Models
Cassette Models
High Wall Models
High Wall Models
Console Models
40MBQB09D--3
40MBCQ09---3
40MAQB09B--3
40MHHQ09---3
40MBFQ09---3
Indoor Units and the Approved Combinations
Ducted Unit
Ceiling Cassette
PerformanceTM High Wall
ComfortTM High Wall
Console
4 @ 1/4"
3 @ 3/8" 1 @ 1/2"
Factory Installed
10 YEARS
5 @ 1/4"
3 @ 3/8" 2 @ 1/2"
Factory Installed
10 YEARS
3 @ 1/4"
3 @ 3/8"
Factory Installed
10 YEARS
4 @ 1/4"
3 @ 3/8" 1 @ 1/2"
Factory Installed
10 YEARS
Liquid Line
Suction Line
2 @ 1/4"
2 @ 3/8"
Factory Installed
10 YEARS
PRE
CHARGE
LENGTH
MAX LIFT
MCA
MOCP
BASEPAN
HEATER
Warranty With
Registration
MGR Multi-Zone Heat Pumps
Two zone minimum connection required on all units.
Port adaptors included with the outdoor unit and no branch box required
PerformanceTM Multi-Zone Heat Pump
OUTDOOR UNIT
MAX
ZONES
MAX HEATING CAPACITY
BTU's / %
PORT COMBINATIONS
MIN LINE
LENGTH
MAX
ZONE
LENGTH
TOTAL
LINE
LENGTH
Optional Included
Heating Capacity BTU's / % of rated
Outdoor Unit
208/230V
Indoor Unit
208/230V
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
MA*R Series High-Wall Single Zone Heat Pump with Inverter Technology
Heat Pump with factory installed base pan heater – Variable Speed System
Indoor unit is powered from outdoor unit.
1/4"
Cooling Outdoor DB Min - Max °F
Heating Outdoor DB Min - Max °F
82 Feet
98 Feet
164 Feet
32 Feet
65 Feet
82 Feet
Maximum Over-Current Protection
15A
15A
25A
30A
30A
35A
Suction/Vapor Line Connection Size
Minimum Circuit Ampacity
25A
9A
Misc. Operational Data
Cooling Cap. Range; Min-Max Btu/h
Heating Cap. Range; Min-Max Btu/h
36,000
30,000
24,000
18,000
9,000
8,000-36,200
8,000-30,500
Indoor Conditions DB 69°F
5,310 / 49%
Controller Set Point Range
Liquid Line Connection Size
ODU Precharged R410a
Precharged for 25ft of line set
Minimum Line Set Length
Maximum Elevation / Lift
Maximum Line Set Length
Weigh In 0.16oz/ft >25ft
Weigh In 0.32oz/ft >25ft
3.31 lbs
4.30 lbs
5.73 lbs
6.06 lbs
10 Feet
10 Feet
10 Feet
3.31 lbs
9A
62°F to 86° Applicable to Heating Mode and Cooling Mode; Wired or Wireless Controllers
20A
20A
18A
7.50 lbs
3/8"
38MAQB09R--3
40MAQB09B--3
9,000
10,900
25.0
14.5
11.2
12,010 / 110%
9,020 / 83%
5,310 / 44%
38MAQB18R--3
40MAQB18B--3
17,000
18,000
20.0
12.5
10.3
18,520 / 103%
16,520 / 92%
12,420 / 69%
38MAQB12R--3
40MAQB12B--3
12,000
12,000
22.5
12.5
12.0
12,010 / 102%
9,020 / 75%
15,050 / 63%
38MAQB30R--3
40MAQB30B--3
30,000
30,000
19.8
11.5
9.4
16,380 / 55%
14,320 / 48%
12,850 / 43%
38MAQB24R--3
40MAQB24B--3
24,000
24,000
20.5
12.5
10.3
24,030 / 100%
16,520 / 69%
Non-Programmable
KSACN0401AAA
Programmable Wired Wall Mount Controller
38MAQB36R--3
40MAQB36B--3
36,000
36,000
Accessory Model
Sold separately through RCD
Description
Notes
Includes 19ft cable / max 66ft
KSACN0101AAA
17401204001601
17401204000769
17317100A33862
Non-Programmable Wired Wall Mount Controller
19ft Extension Cable Kit for KSCAN0101AAA
Cooling Only Wireless Remote Control
17317100A11505
Programmable Cooling Only Wired Controller
Includes 19ft cable / max 66ft
19ft Extension Cable Kit for KSCAN0401AAA & 17317100A11505 (through RCD)
16.0
8.6
8.5
16,380 / 46%
14,320 / 40%
13,800 / 38%
5,500-24,000
9,000-37,000
3/8"
1/2"
5/8"
Includes 19ft cable / max 66ft
Carrier Duct-Free System Accessories Compatible With 40MAQBxxB--3 High Wall IDU's
5,500-24,500
4,500-18,800
3,500-13,000
6,000-32,000
9,000-34,000
Outdoor Ambient -13°F to 122°F
Outdoor Ambient -22°F to 86°F
12,000
4,000-13,800
5,000-15,500
4,500-14,500
Heating Capacity BTU's / % of rated
Outdoor Unit
208/230V
Indoor Unit
208/230V
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
At 5°F Outdoor Ambient
At -13°F Outdoor Ambient
At -22°F Outdoor Ambient
Included Optional
Heat Pump with factory installed base pan heater – Variable Speed System
MA*R Series Ceiling Cassette Single Zone Heat Pump with Inverter Technology
Outdoor Unit
208/230V
Indoor Unit
208/230V requires
40MBQB01C--- ceiling
grille
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Heating Capacity BTU's / % of rated
Indoor unit is powered from outdoor unit.
Outdoor Unit
208/230V
Indoor Unit
208/230V requires
40MBQB01C--- ceiling
grille
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Indoor Conditions DB 69°F
Indoor unit ceiling grille required and SOLD SEPARATELY p/n: 40MBQB01C---
20.0
16,000
18,000
40MBQB18C--3
40MBQB12C--3
Heating Capacity BTU's / % of rated
At 5°F Outdoor Ambient
At -13°F Outdoor Ambient
At -22°F Outdoor Ambient
40MBQB09C--3
13.0
20.0
9,000
9,000
40MBCQ09---3
40MBCQ12---3
40MBCQ18---3
7,540 / 63%
6,890 / 57%
7,160 / 80%
7,320 / 81%
10,472 / 116%
KSACN0501AAA
Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
17317100A11945
Programmable Cooling Only Wired Controller
Includes 19ft cable / max 66ft
Indoor unit includes integrated condensate lift pump. Drain line connection 25mm or 0.98" outside diameter.
Carrier Duct-Free System Accessories Compatible With 40MBQBxxC--3 Cassette IDU's
Accessory Model
Description
Notes
KSACN0101AAA
Non-Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
17401204001601
19ft Extension Cable Kit for KSCAN0101AAA
Sold separately through RCD
Misc. Operational Data
9,000
12,000
18,000
Cooling Cap. Range; Min-Max Btu/h
3,500 - 11,000
4,000 - 13,000
4,500 - 18,000
17401204000769
17317100A33862
Cooling Only Wireless Remote Control
Non-Programmable
19ft Extension Cable Kit for KSCAN0501AAA & 17317100A11945 (through RCD)
Heating Outdoor DB Min - Max °F
Outdoor Ambient -22°F to 86°F
Maximum Line Set Length
82 Feet
82 Feet
98 Feet
Heating Cap. Range; Min-Max Btu/h
4,500 - 11,500
5,000 - 13,500
5,500 - 19,000
Cooling Outdoor DB Min - Max °F
Outdoor Ambient -13°F to 122°F
Precharged for 25ft of line set
Weigh In 0.16oz/ft >25ft
ODU Precharged R410a
3.31 lbs
3.31 lbs
4.30 lbs
Maximum Elevation / Lift
32 Feet
32 Feet
65 Feet
Minimum Line Set Length
10 Feet
10 Feet
10 Feet
25A
Liquid Line Connection Size
1/4"
1/4"
1/4"
Suction/Vapor Line Connection Size
3/8"
1/2"
1/2"
10.8
12,000
12,000
19.5
12.5
10.6
12,220 / 102%
Controller Set Point Range
62°F to 86° Applicable to Heating Mode and Cooling Mode; Wired or Wireless Controllers
38MAQB09R--3
38MAQB12R--3
38MAQB18R--3
11,910 / 74%
12,589 / 79%
19,005 / 119%
10.5
12.5
Minimum Circuit Ampacity
9A9A18A
Maximum Over-Current Protection
15A
15A
Included Optional
Heat Pump with factory installed base pan heater – Variable Speed System
MA*R Series Floor Console Single Zone Heat Pump with Inverter Technology
Outdoor Unit
208/230V
Indoor Unit
208/230V
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Heating Capacity BTU's / % of rated
Includes 19ft cable / max 66ft
17401204001601
19ft Extension Cable Kit for KSCAN0101AAA
Sold separately through RCD
KSACN0401AAA
Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
Outdoor Unit
208/230V
Indoor Unit
208/230V
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Includes 19ft cable / max 66ft
Indoor unit is powered from outdoor unit.
Indoor Conditions DB 69°F
40MBQB12F--3
Heating Capacity BTU's / % of rated
At 5°F Outdoor Ambient
At -13°F Outdoor Ambient
At -22°F Outdoor Ambient
40MBQB09F--3
38MAQB09R--3
38MAQB12R--3
40MBFQ09---3
Carrier Duct-Free System Accessories Compatible With 40MBQBxxF--3 Floor Console IDU's
Accessory Model
Description
Notes
12,000
Cooling Cap. Range; Min-Max Btu/h
3,500 - 11,000
4,000 - 13,000
17401204000769
17317100A33862
Cooling Only Wireless Remote Control
Non-Programmable
Misc. Operational Data
9,000
19ft Extension Cable Kit for KSCAN0401AAA & 17317100A11505 (through RCD)
5,000 - 13,500
Cooling Outdoor DB Min - Max °F
Outdoor Ambient -13°F to 122°F
Heating Outdoor DB Min - Max °F
Outdoor Ambient -22°F to 86°F
1/4"
Maximum Line Set Length
82 Feet
Maximum Elevation / Lift
32 Feet
Minimum Line Set Length
10 Feet
15A
Controller Set Point Range
62°F to 86° Applicable to Heating Mode and Cooling Mode; Wired or Wireless Controllers
40MBFQ12---3
Suction/Vapor Line Connection Size
3/8"
1/2"
Minimum Circuit Ampacity
9A
9A
Precharged for 25ft of line set
Weigh In 0.16oz/ft >25ft
ODU Precharged R410a
3.31 lbs
3.31 lbs
Liquid Line Connection Size
Maximum Over-Current Protection
15A
1/4"
Heating Cap. Range; Min-Max Btu/h
4,500 - 11,500
17317100A11505
Programmable Cooling Only Wired Controller
12,000
12,000
8,500
10.5
12.5
19.4
11.6
12.5
20.0
9,000
KSACN0101AAA
Non-Programmable Wired Wall Mount Controller
7,820 / 87%
7,952 / 88%
9,989 / 111%
7,290 / 61%
8,151 / 68%
12,010 / 100%
Includes Both
Controllers
Heat Pump with factory installed base pan heater – Variable Speed System
MA*R Series Ducted Single Zone Heat Pump with Inverter Technology
Outdoor Unit
208/230V
Indoor Unit
208/230V
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
40MBQB*D
40MBDQ
HSPF
Heating Capacity BTU's / % of rated
0.64
38MAQB18R--3
38MAQB24R--3
Max. External Static Pressure In. WG.
0.18
0.18
0.40
0.64
0.64
Controller Set Point Range
62°F to 86° Applicable to Heating Mode and Cooling Mode; Wired or Wireless Controllers
Factory Set Static Pressure In. WG
0.02
0.02
ECM Blwr Mtr Automatically Adjusts Uo To Max ESP
35A
Maximum Over-Current Protection
15A
15A
25A
30A
50A
50A
Minimum Circuit Ampacity
9A9A18A
20A
30A
9.26 lbs
Liquid Line Connection Size
1/4"
3/8"
Suction/Vapor Line Connection Size
3/8"
1/2"
5/8"
Precharged for 25ft of line set; oz/ft >25ft
Weigh in 0.16oz/ft >25ft
0.32oz/ft
Weigh in 0.43oz/ft>25ft
ODU Precharged R410a
3.31 lbs
3.31 lbs
4.30 lbs
5.73 lbs
6.72 lbs
Maximum Elevation / Lift
32 Feet
65 Feet
98 Feet
Minimum Line Set Length
10 Feet
10 Feet
10 Feet
Cooling Outdoor DB Min - Max °F
Outdoor Ambient -13°F to 122°F
Heating Outdoor DB Min - Max °F
Outdoor Ambient -22°F to 86°F
Maximum Line Set Length
82 Feet
98 Feet
213 Feet
9,000-50,000
Heating Cap. Range; Min-Max Btu/h
4,500-11,500
5,000-13,500
5,500-19,000
6,000-26,000
9,500-50,000
10,000-55,000
Cooling Cap. Range; Min-Max Btu/h
3,500-11,000
4,000-13,000
4,500-18,800
5,500-24,500
8,500-38,000
17317100A33862
Cooling Only Wireless Remote Control
Non-Programmable
Misc. Operational Data
9,000
12,000
18,000
24,000
36,000
48,000
17317100A11945
Programmable Cooling Only Wired Controller
Includes 19ft cable / max 66ft
17401204000769
Indoor unit includes integrated condensate lift pump. Drain line connection 25mm or 0.98" outside diameter.
Carrier Duct-Free System Accessories Compatible With 40MBQB & 40MBDQ Ducted IDU's
Accessory Model
Description
Notes
KSACN0501AAA
Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
KSACN0101AAA
Non-Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
17401204001601
19ft Extension Cable Kit for KSCAN0101AAA
Sold separately through RCD
19ft Extension Cable Kit for KSCAN0501AAA & 17317100A11945 (through RCD)
24,650 / 48%
Indoor unit is powered from outdoor unit.
Indoor Conditions DB 69°F
8.5
10.5
25,300 / 67%
17,570 / 46%
14,680 / 39%
38MBRQ48A--3
40MBDQ48---3
48,000
51,000
17.4
38MBRQ36A--3
40MBDQ36---3
36,000
38,000
15.5
8.9
10.3
34,000 / 67%
27,120 / 53%
40MBQB24D--3
24,000
24,000
20.5
12.5
11.5
25,042 / 104%
16,520 / 69%
15,250 / 64%
40MBDQ24---3
24,000
24,000
20.5
12.5
12.5
25,042 / 104%
16,520 / 69%
15,250 / 64%
40MBQB18D--3
16,500
18,000
19.6
12.5
10.5
18,920 / 105%
12,509 / 69%
11,650 / 65%
40MBDQ18---3
16,500
18,000
19.6
12.5
11.0
18,920 / 105%
12,509 / 69%
11,650 / 65%
8,114 / 81%
38MAQB12R--3
40MBQB12D--3
11,500
12,000
19.0
12.5
10.5
12,300 / 103%
8,562 / 71%
7,790 / 65%
38MAQB09R--3
40MBQB09D--3
9,000
10,000
19.0
13.0
11.1
11,068 / 111%
8,353 / 84%
Outdoor Unit
208/230V
Indoor Unit
208/230V
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Heating Capacity BTU's / % of rated
At 5°F Outdoor Ambient
At -13°F Outdoor Ambient
At -22°F Outdoor Ambient
Included
Controller Set Point Range
62°F to 86° Applicable to Heating Mode and Cooling Mode; Wired or Wireless Controllers
Includes 19ft cable / max 66ft
Programmable Wired Wall Mount Controller
KSACN0401AAA
17401204000769
19ft Extension Cable Kit for KSCAN0401AAA & 17317100A11505 (through RCD)
17317100A11505
Programmable Cooling Only Wired Controller
Includes 19ft cable / max 66ft
17317100A33862
Cooling Only Wireless Remote Control
Carrier Comfort Series 40MHHQ High-Wall Heat Pumps with Inverter Technology
Outdoor Unit
Indoor Unit
Cool Btuh
Heat
Btuh
SEER
EER
HSPF
MCA
MOPA
Heating BTU's / % of rated
at 5°F Outdoor Ambient
Optional
38MHRQ09A--1*
40MHHQ09---1
9,000
9,800
16.0
11.0
9.0
13A / 20A
6,100 / 62%
5,370 / 45%
38MHRQ18A--3**
40MHHQ18---3
18,000
18,000
16.0
11.0
9.0
38MHRQ12A--1*
40MHHQ12---1
12,000
12,000
16.8
10.8
5,700 / 58%
38MHRQ12A--3**
40MHHQ12---3
12,000
12,000
17.0
10.9
9.0
6,070 / 51%
40MHHQ24---3
22,000
25,000
16.8
10.5
9.0
18A / 25A
9.0
13A / 20A
10A / 15A
38MHRC12A--1*
40MHHC12---1
120/1/60
12,000
17.3
10.7
13A
20A
38MHRC09A--1*
40MHHC09---1
120/1/60
9,000
16.6
11.6
13A
20A
5,800 - 18,600
38MHRC18A--3**
40MHHC18---3
208-230/1/60
18,000
17.0
10.5
11A
15A
38MHRC24A--3**
40MHHC24---3
208-230/1/60
24,000
17.5
10.9
16A
25A
9,400 - 25,200
*System Voltage is 120/1/60. **System voltage is 208-230/1/60. Indoor unit is powered from outdoor unit.
Wireless remote control included with indoor unit. Wired remote control accessory available separately.
Carrier MHHQ/MHHC System Accessories
Accessory Model
Description
Notes
Non-Programmable
Miscellaneous Operational Data
System BTU Size
9K
12K
18K
24K
Liquid X Vapor
1/4" X 3/8"
1/4" X 1/2"
1/4" X 1/2"
3/8" X 5/8"
Max L / Max E / Min L
82ft / 32ft / 10ft
98ft / 65ft / 10ft
164ft / 65ft / 10ft
3,000 - 12,500
3,500 - 19,800
4,000 - 24,200
Refrigerant
Pre-charged for 25ft of line set. Add 0.161oz per foot over 25ft.
Add 0.322oz/ft over 25ft
MHRQ ODU Precharge R410a
1.76 lbs
2.11 lbs
2.82 lbs
3.97 lbs
Heating Outdoor DB Min - Max °F
Outdoor Ambient 0°F to 86°F (Heat Pump Only)
38MHRQ09A--3**
40MHHQ09---3
8,500
9,800
16.0
10.5
9.0
8A / 15A
MHRQ Heating; Min - Max Btu/h
2,500 - 11,800
3,000 - 12,800
3,500 - 19,800
4,000 - 24,200
Cooling Outdoor DB Min - Max °F
Outdoor Ambient 0°F to 122°F
MHRC ODU Precharge R410a
1.06 lbs
1.30 lbs
2.09 lbs
2.64 lbs
MHRQ Cooling; Min - Max Btu/h
2,400 - 10,500
MOPA
7A
15A7A15A
4,800 - 13,000
4,400 - 10,000
4,800 - 13,200
4,400 - 10,200
Cooling Range BTU Min - Max
14,920 / 60%
15A / 20A
9,670 / 54%
38MHRQ24A--3**
38MHRC12A--3**
40MHHC12---3
208-230/1/60
12,000
16.5
10.8
38MHRC09A--3**
40MHHC09---3
208-230/1/60
9,000
16.0
10.6
Carrier Comfort Series 40MHHC High-Wall Cooling Only with Inverter Technology
Outdoor Unit
Indoor Unit
Outdoor Volts
Cool Btuh
SEER
EER
MCA
At 69°F Indoor
8
6,150 / 51%
Application
All MFC/MFQ Series
All MFC/MFQ Series
MFC/MFQ 12K, 18K, 22K (230 V)
MFC/MFQ 9K & 12K (115 V)
Outdoor Ambient 14°F to 115°F
Outdoor Ambient 5°F to 75°F (Heat Pump Only)
Heating Cap BTU's / % @
20°F Outdoor Ambient
6,100 / 68%
11,260 / 51%
9,490 / 53%
6,150 / 51%
4,500 - 13,000
5,500 - 19,000
6,500 - 24,000
4,500 - 13,000
5,500 - 19,500
6,500 - 24,000
1.87 lbs
2.60 lbs
Miscellaneous Operational Data
System BTU Size
9K
Heating Outdoor DB Min - Max °F
Cooling Outdoor DB Min - Max °F
Cooling Range; Min - Max Btu/h
Heating Range; Min - Max Btu/h
4,000 - 10,000
4,000 - 10,500
MFC ODU Precharged R410a
1.43 lbs
1.43 lbs
Refrigerant
Pre-charged for 25ft of line set. Add 0.16oz per foot over 25ft.
Add 0.32oz/ft over 25ft
MFQ ODU Precharged R410a
2.60 lbs
2.60 lbs
2.87 lbs
3.52 lbs
Liquid X Vapor
1/4" X 3/8"
1/4" X 1/2"
1/4" X 1/2"
3/8" X 5/8"
Max L / Max E / Min L
65ft / 25ft / 10ft
65ft / 30ft / 10ft
98ft / 30ft / 10ft
12K
17K & 18K
22K
53DS-900---118
Condensate Pump
KSACN0101AAA
Optional Wired Remote Controller
53DS-900---059
Wireless Controller Locking Mount
53DS-900---117
Condensate Pump
*Outdoor Voltage is 120/1/60. **Outdoor voltage is 208-230/1/60. Indoor unit is powered from outdoor unit.
Wireless remote control included with indoor unit. Wired remote control accessory available separately.
Carrier MFQ/MFC System Accessories
Accessory Model
Description
38MFC022---3**
40MFC022---3
208-230/1/60
22,000
15.0
10.0
16A
25A
38MFC018---3**
40MFC018---3
208-230/1/60
18,000
15.0
8.5
14A
20A
38MFC012---3**
40MFC012---3
208-230/1/60
12,000
15.0
9.0
10A
15A
38MFC012---1*
40MFC012---1
120/1/60
12,000
15.0
9.0
19A
30A
38MFC009---1*
40MFC009---1
120/1/60
9,000
15.0
10.0
19A
30A
Carrier Comfort MFC Series High-Wall Cooling Only with Inverter Technology
Outdoor Unit
Indoor Unit
Outdoor Volts
Cool Btuh
SEER
EER
MCA
MOPA
9.5
8.2
16A / 25A
8.2
14A / 20A
38MFQ022---3**
40MFQ022---3
22,000
22,000
15.0
38MFQ017---3**
40MFQ017---3
17,000
18,000
15.0
10.5
9.5
8.2
10A / 15A
8.2
19A / 30A
38MFQ012---3**
40MFQ012---3
12,000
12,000
15.0
19A / 30A
38MFQ012---1*
40MFQ012---1
12,000
12,000
15.0
9.5
38MFQ009---1*
40MFQ009---1
9,000
9,000
15.0
10.5
8.2
Included Optional
Carrier Comfort MFQ Series High-Wall Heat Pumps with Inverter Technology
Outdoor Unit
Indoor Unit
Cool Btuh
Heat
Btuh
SEER
EER
HSPF
MCA
MOPA
At 69°F Indoor DB
9
Loading...
+ 18 hidden pages