Carrier 40MFQ user guide manual

40MFC / 38MFC 40MFQ / 38MFQ High---Wall Ductless Split System Sizes 009 to 022
Owner's Manual
TABLE OF CONTENTS
PAGE
A NOTE ABOUT SAFETY 2...................................................................................
DISPLAY PANELS 4..........................................................................................
REMOTE CONTROL 5........................................................................................
REMOTE CONTROL FUNCTIONS 6--7..........................................................................
CLEANING, MAINTENANCE AND TROUBLESHOOTING 8 -- 9.....................................................
NOTE TO EQUIPMENT OWNER:
Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # ___________________________________ Serial # ___________________________________
INSTALLATION INFORMATION
Date Installed _____________________________
DEALERSHIP CONTACT INFORMATION
Company Name: _________________________________ Address:_________________________________________ ________________________________________________ Phone Number:__________________________________ Technician Name:_________________________________ ________________________________________________
A NOTE ABOUT SAFETY
Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution:
DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards that could result in personal injury or death.
CAUTION is used to identify unsafe practices which could result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
!
PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or service agency must use factory--authorized kits or accessories when modifying this product.
Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.
WARNING
GENERAL
The high wall fan coil unit provides quiet, maximum comfort. In addition to cooling and/or heating, the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort. IMPORTANT: The high wall fan coil unit should be installed by authorized personnel only; using approved tubing and accessories. If technical assistance, service or repair is needed, contact the installer. The high wall fan coil unit can be set up and operated from the remote control (provided). If the remote is misplaced, the system
can be operated from the “Auto” setting on the unit.
Operating Modes:
The high wall fan coil unit has five operating modes.
S Fan only S Auto S Heating (heat pump models only) S Cooling S Dehumidification (DRY)
Fan Only
In Fan Only mode, the system filters and circulates room air without changing room air temperature.
Auto
In Auto mode, the system will automatically cool or heat the room according to the user--selected set point.
Heating
In Heating mode, the system heats and filters room air.
Cooling
In Cooling mode, the system cools, dries and filters room air.
Dehumidification (DRY)
In Dehumidification mode, the system dries, filters and slightly cools room air temperature. This mode prioritizes air dehumidification but it does not take the place of a dehumidifier.
Remote Control
The remote control transmits commands to set up and operate the system. The control has a window display panel that shows the current system status. The control can be secured to a surface when used with the mounting bracket provided.
2
PART NAMES
■ Indoor
10
M
S w
i n g
S e l
f C
S
l
e
l e
a
e
n
F
ol
I o
l
ni
o w
ze
M
r
e S m
L
a
E
r
D
t
E y e
F.P
.
S
i l e n
■ Outdoor
1
2
1. Front panel
3
2. Air Inlet
3. Display
4. Air Filter
5. Horizontal airflow grille
6. Vertical air flow louver
4
5
Air Outlet
11
6
7
A U T
O C O
O
D
L
R
Y
HE
AT
F A
N HI G
H
T
M
E
ED
M
L
P
O
o
W
d e
O n
/ O f
f
F a n
p
T i m e
r
T u rb
o
c e
12
7. Interconnecting tubing
8. Control and power wiring to indoor unit
9. Service valves
10. Remote control
11. Remote control bracket
12. Self-- tapping screws
8
9
A14354
Indoor/Outdoor Unit
1. Temp Up /TempDown Buttons
2. Mode Button
AUTO
COOL
DRY
HEAT
1
TEMP
FAN
HIGH
MED
LOW
3. On/Off Button
4. Horizontal Swing
Button
5. Self Clean Button
On/Off
Mode
2
3
S w i
n
4
g
Follow Me
Self Clean
5
Ionizer
6
Smart Eye
SLEEP
Fan
LED Turbo
F.P.
Silence
7
T im
er
8
9
10
11
6. Follow Me Button
7. Fan Button
8. Timer On
9. Sleep Button
10. Turbo Button
/TimerOff Buttons
11. LED / F.P Button
NOTE: Vertical Swing, Ionizer, Smart Eye, and Silence are not available on this model.
A14355
Remote Control
3
DISPLAY PANELS
SELECTED TEMPERATURE /
SELF-DIAGNOSTIC CODES indicator
DEFROST indicator
Illuminates when the coil is warming up to prevent cold blow or when the unit goes into defrost mode.
OPERATION indicator This indicator flashes once per second after power is on and illuminates when the unit is in operation.
TIMER indicator Illuminates during TIMER operation
A14356
Unit Display
______________________________________________________________________________________________________________
1. OPERATING MODE DISPLAY:
3
2
SET TEMPERATURE
1
TIMER ON OFF
4
5
6
8
7
Indicates the current operation mode “AUTO”, “COOL”, “DRY”, “HEAT” (heat pumps only), or “FAN”.
2. TRANSMISSION INDICATOR:
Illuminates when remote control transmits signals to the in­door unit.
3. TEMPERATURE/TIMER DISPLAY:
Temperature setting from 62_F(17_C) to 86_F(30_C) or set times for the timer operation (0~24h) will be displayed. If FAN mode is selected, there will be no temperature dis­played.
4. ON/OFF INDICATOR:
This symbol appears when the unit is turned on by the re­mote control, and disappears when the unit is turned off.
5. FA N M OD E D ISP LAY:
Indicates when fan mode is selected.
6. FAN SPEED DISPLAY:
Indicates the set fan speed. Nothing is displayed when the mode is set to AUTO or DRY.
7. FOLLOW ME DISPLAY:
This indicator will be displayed when the remote sensing function is activated. This option is not available in DRY and FAN modes.
8. TIMER DISPLAY:
Indicates the timer settings. It displays “TIMER ON” when the auto--on time function is set, “TIMER OFF” when the auto--off time function is set, and “TIMER ON OFF when both functions are set.
NOTE: Symbols shown in this manual are for the purpose of demonstration. During actual operation, only the relevant symbols are displayed.
Remote Control Display
4
A14357
REMOTE CONTROL
AUTO
COOL
DRY
HEAT
S w i
n g
Self Clean
FAN
HIGH
MED
LOW
TEMP
On/Off
Mode
Fan
Time
SLEEP
r
Follow Me
LED Turbo
F.P.
Ionizer
Smart Eye
Silence
A U T
O C O
O
D
L
R
Y
H E
A T
F A
N H I G
H
T
M
E
E
M
D
L
P
M
O
o
W
d e
O n
S
/ O
w
f
f
i n g
Fa n
S
e l f
C
S
lea
l e
e
n
p
F
o
Ion
l l
ow iz e
M
r
e
S
T
m
L
i m
a
E
r
D
e
t Ey
r
e
T u rb
F.P
o
.
S
i l e n
c e
A14358
!
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage. Handle the control with care and avoid getting the control wet.
IMPORTANT: The remote control can operate the unit from a distance of up to 25 ft. (7.6 m) as long as there are no obstructions.
When the timer function is used, the remote control should be kept in the vicinity of the fan coil (within 25 ft / 7.6 m)
The remote control can perform the following basic functions:
S Turn the system ON and OFF S Select operating mode S Adjust room air temperature set point and fan speed S Adjust airflow direction
Refer to the Remote Control Function section for detailed description of all the capabilities of the remote control.
Battery Installation
Two AAA 1.5 v alkaline batteries (included) are required for operation of the remote control.
To install or replace batteries:
1. Slide the back cover off the control to open the battery com­partment.
2. Insert batteries. Follow the polarity markings inside the battery compartment.
3. Replace battery compartment cover.
NOTE:
1. When replacing batteries, do not use old batteries or a different type battery. This may cause the remote control to malfunction.
2. If the remote is not going to be used for several weeks, remove the batteries. Otherwise battery leakage may damage the remote control.
3. The average battery life under normal use is about 6 months.
4. Replace the batteries when there is no audible beep from the indoor unit or if the Transmission Indicator fails to light.
5. When batteries are removed, the remote control erasesall programmed settings. The control must be reprogrammed after insertion of new batteries.
Remote Control Operation -- Quick Start
NOTE: When transmitting a command from the remote control to
the unit, be sure to point the control toward the right side of the unit. the unit will confirm receipt of a command by sounding an audible beep.
1. Turn the unit on by pushing the ON/OFF button.
2. If there is a preference for _C rather than _F (default), press
and hold the increase point buttons together for approximately 3 seconds.
3. Select the desired mode by pushing the mode button.
AUTO
COOL
NOTE: Cool only units have no heat mode.
4. Select the temperature set point by pointing the control to­ward the unit and pressing the increase/decrease temperature set point buttons until the desired temperature appears on screen.
5. Select the desired fan speed by pressing the FAN button.
NOTE: If unit is operating in DRY or AUTO mode, the fan speed will be automatically set.
6. Set the airflow direction. When the unit is turned on, the
louvers default to the cooling or heating position. The user can adjust the horizontal louver position by pushing the horizontal swing button or have continuous louver move­ment by pressing this button for two or more seconds..
Manual Operation
If the remote control is lost, damaged, or the batteries are exhausted, the MANUAL button can be used to run the unit.
When the MANUAL button is pressed once, AUTO mode will take place (heat or cool). When this button is pressed twice, the system will enter in TEST mode and run for 30 minutes in the COOLING mode (it will run in the AUTO mode afterward). When it is pressed three times, the system will be turned OFF.
The set conditions of manual operation are as follows:
S Preset set point: 76_F(24_C) S Fan speed: AUTO S Discharge air direction: Pre--set position based on operation in
“Cool”or “Heat” mode.
5
and decrease temperature set
DRY
HEAT
Manual Button
AUTO/COOL
FAN
A14359
REMOTE CONTROL FUNCTIONS
Pressing the On/Off Button
When the air conditioner is not in operation, the remote control will display the last set point and mode.
S Press the On/Off button to start the unit.
-- The unit will start in thelast operating mode and set point. The ON/OFF indicator will appear.
S Press button On/Off to stop the unit.
-- All indicator lights on the unit will go out, and the remote control will display the set point and mode.
NOTE: If theOn/Off button is pressed too soon after a stop, the compressor will not start for 3 to 4 minutes due to the inherent protection against frequent compressor cycling. The unit will only emit an audible beep when the signals are received correctly.
Selecting an Operating Mode
Use the Operating Mode button to select one of the available modes.
SET TEMPERATURE
TIMER ON OFF
AUTO
NOTE: HEAT mode is only available for heat pump models
Setting the Room Temperature Set Point
Pressing the increase temperature set point and decrease buttons will raise or lower the temperature.
The unit will confirm signal receipt with a beep and the value of the set temperature on the display will change accordingly.
The temperature can be set between 62_F(17_C) and 86_F(30_C) in increments of 1_For1_C.
NOTE: In Cooling mode, if the temperate selected is higher than the room temperature, the unit will not start. The same applies for the Heating mode if the selected temperature is lower than the room temperature.
Selecting the Fan Speed
COOL
DRY
HEAT
FAN
A14360
Selecting the Horizontal Direction Louver Position
In order to optimize comfort, the horizontal louver will operate in a preset range as shown in the figure below.
COOLING
HEATING
A08044
The horizontal louvers can be adjusted by pressing the horizontal SWING button
in the remote control and can be set to be stationary or moving continuously. The horizontal louver position is stored in the settings, but it is deactivated when the TURBO or MANUAL settings are set, or when a power interruption takes place.
ection
Air Dir
Press the horizontal
button repeatedly to choose one of the louver positions. Every time this button is pushed, the specific louver will swing by 6 degrees.
In the Cooling, Dehumidification, and Fan Only modes, the louver will swing in the cooling range. In the Heating mode (for heat pump models), the louver will swing in the heating range.
NOTE: Always use theremote control to adjust the horizontal louver position, otherwiseabnormal operation may occur. If the louver is manually adjusted out of its range, power the unit off and then on again.
Auto Swing
For automatic horizontal louver swing, push the horizontal swing button
for two or more seconds.
Selecting Vertical Direction of the Louver
The vertical louvers can be adjusted manually to direct the airflow to achieve optimal comfort in the space.
AUTO
LOW
MED
HIGH
The fan speed can be selected by pressing the FAN button. NOTE: When the unit is on, the fan will run continuously in
cooling or heating. When in heating, there might be situations where the fan will slow down or shut off to prevent cold blow.
A14362
A07543
6
Timer Function
TIMER ON (to start the unit) and TIMER OFF (to stop the unit) can be used separately or together.
Timer ON only
This function will allow the unit to start automatically at the set time. The TIMER ON can be set while the unit is on or off.
UNIT ON
-- P r e s s t h e T I M E R O N sequence. The set time is displayed in the remote control display. Every time the TIMER ON button is pressed, the time will increase by 30 minutes, up to 10 h. It will increase by 60 minutes, afterwards, until the time setting reaches 24 h.
-- When the TIMER ON is set, the TIMER light on unit illuminates. The unit will continue to run at the set time.
UNIT OFF
-- Set the timer described in the UNIT ON section.
-- Theunitwillstartatthesettime.
Adjust the TIMER ON settings to 0.0 to cancel this option.
button to initiate the auto-on time
Timer OFF only
This function will allow the unit to stop automatically at the set time. The timer can be set while the unit is on or while it is off.
UNIT ON
-- Press the TIMER OFF sequence. The set time is displayed in the remote control display. Every time the TIMER OFF button is pressed, the time will increase by 30 minutes, up to 10 h. It will increase by 60 minutes, afterwards, until the time settings reach 24 h.
-- When the TIMER OFF is set, the timer light on the unit illuminates and the unit turns off automatically at the set time.
UNIT OFF
-- Set the TIMER off as described in the UNIT ON section.
-- The TIMER display on the unit illuminates and the unit will remain off.
Adjust the TIMER ON settings to 0.0 to cancel this option.
button to initiate the auto--off time
Timer ON and Timer OFF
Use both functions to program the unit to turn on and shut off at specified times.
UNIT OFF
-- Set TIMER ON as previously described.
-- Set TIMER OFF as previously described.
-- The unit will start automatically at the set TIME ON and will turn off at the set TIME OFF.
UNIT ON
-- Set TIME OFF as previously described.
-- Set TIME ON as previously described.
-- The unit will turn off automatically at the set TIME OFF and will turn on at the set TIME ON.
Sleep Mode
This mode is used to conserve energy and can be used when the unit is in the COOL, HEAT or AUTO mode only.
Cool Mode
-- Push the SLEEP button.
-- After 1 hour the set point will be raised by 1.8_F(1_C).
-- After another hour, the set point will be raised by another
1.8_F(1_C)andthefanwillruninlowspeed.
-- The unit will shut off 5 hours after setting the SLEEP mode.
-- The SLEEP mode will be cancelled if either the “Mode”, “TEMP”, “Fan”, “Timer”, or “On/Off” buttons on the remote control is pressed.
Heat Mode
-- Same as cooling mode but set points will be lowered by
1.8_F(1_C).
Turbo Mode
Use the TURBO mode to cool or heat the room rapidly.
-- Press the TURBO button. An audible “beep” will be heard if the indoor unit supports this function.
-- Thefanwillrunonsuperhighspeed.
-- The TURBO mode terminates automatically after 20 minutes from pushing the Turbo mode button. It can be terminated immediately by pushing the Turbo mode again. When the Turbo mode is terminated, the unit will go back to the original setting.
Resetting the Remote Control
If the batteries in the remote control are removed, the current settings will be cancelled and the control will return to the initial settings and will be in standby mode. Push the ON/OFF button to activate it.
Time Delay
If the On/Off button is pressed too soon after a stop, the compressor will not start for 3 to 4 minutes due to the inherent protection against frequent compressor cycling. The unit will only emit an audible beep when the signals are received correctly.
Heating Features
If the unit is in the heating mode, there will be a delay when the fan starts. The fan will start only after the coil is warmed up to prevent cold blow.
Auto Defrost Operation
In heating mode, if the outdoor coil is frosted, the indoor fan and outdoor fan will turn off while system removes the frost on the outdoor coil.
The system will automatically revert to normal operation when frost is removed from the outdoor unit.
Auto Start
If the power fails while the unit is operating, the unit stores the operating condition, and it will start operation automatically under those conditions when the power is restored.
Self Clean Mode
Press the “Self Clean” button to activate or deactivate the self--cleaning function. Under this function, the air conditioner will automatically clean and dry the evaporator..
Follow Me Mode
Press the “Follow Me” button to activate or deactivate this function. Under this setting, the temperature displayed in the remote control is the actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes. This function is not available for DRY and FAN modes.
LED / F.P. Mode
Press the LED button to turn the display light on and off. Press the “F.P.” button for approximately 2 seconds to activate or deactivate the freeze protection mode. The indoor unit will display “FP”.
This function is only available in the heating mode for heat pumps. Under this function, the unit will operate at high fan speed and the coil temperature will be automatically set to 46_F(8_C).
This mode can also be deactivated by pressing the “On/Off”, “Sleep”, “Mode”, “Fan”, or either “TEMP” buttons.
7
CLEANING, MAINTENANCE AND TROUBLESHOOTING
!
CAUTION
ELECTRICAL SHOCK HAZARD
Failure to follow this caution may result in personal injury or death. Always turn off power to the system before performing any cleaning or maintenance to the system. Turn off the outdoor disconnect switch located near outdoor unit. Be sure to disconnect indoor unit if on a separate switch
!
CAUTION
EQUIPMENT DAMAGE/OPERATION HAZARD
Failure to follow this caution may result in equipment damage or improper unit operation. Operating the system with dirty air filters may damage the indoor unit and could cause reduced cooling performance, intermittent system operation, frost build--up on indoor coil or blown fuses.
Periodic Maintenance
Periodic maintenance is recommended to ensure proper operation of the unit. Recommended maintenance intervals may vary depending on the installation environment, e.g., dusty zones, etc. Refer to Table 1.
!
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury. The coil fins are very sharp. Use caution when cleaning. Always wear safety protection.
Cleaning the Coil
Clean the coil at the beginning of each cooling season, or when necessary. Use a vacuum cleaner or a long--bristle brush to avoid damage to the coil fins.
Air Filters
Remove and clean the air filters once a month. NOTE: If air filters show signs of excessive wear or are torn, they must be replaced. Contact your local dealer for replacement filters.
1. Open front panel on unit.
2. Pull filters down to remove.
3. Vacuum filters.
4. Clean with warm water.
5. Shake filter to remove excess water and dry thoroughly.
6. Replace filter by sliding into rack until filter snaps in place.
7. Close front panel on unit.
Indoor Unit Front Panel
To clean the front panel on the indoor unit, wipe the outside with a soft, dry cloth.
Preparing for Extended Shutdown Period
Clean the filters and reposition them in the unit. Operate the unit in Fan only mode for 12 hours to dry all internal parts.
Turn main power supply off and remove batteries from the remote control.
System Operation Recommendations
The items outlined in the following list will help to assure proper system operation:
S Replace both remote control batteries at the same time. S Point the remote control toward the unit display panel when
transmitting a command.
S Keep doors and windows closed while unit is operating. S Contact an authorized service representative if a problem arises
that cannot be easily resolved.
S Do not perform cleaning or maintenance activities while unit
is on.
S Keep display panel on unit away from direct sunlight and heat
as this may interfere with remote control transmissions.
S Do not block air intakes and outlets on the indoor or outdoor
units.
Energy Saving Recommendations
The following recommendations will add greater efficiency to the ductless system:
S Select a comfortable thermostat setting and leave it at chosen
setting. Avoid continually raising and lowering the setting.
S Keep filter clean. Frequent cleaning may be necessary depend-
ing on indoor air quality.
S Use drapes, curtains or shades to keep direct sunlight from
heating room on very hot days.
S Limit run time by using the TIMER function. S Do not obstruct air intake on front panel. S Turn on air conditioning before indoor air becomes too un-
comfortable.
Troubleshooting
Refer to Table 2 before contacting your local dealer.
!
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage. When cleaning the front panel, do not use water hotter than 105_F (40.6_C) and do not pour water onto the fan coil. Do not use abrasive or petroleum based cleaners as they may damage the front panel.
8
Table 1—Periodic Maintenance
INDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR
Clean Air Filter* Change Remote Control Batteries
S
S
S
OUTDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR
Clean Outdoor Coil from Outside Clean Outdoor Coil from Insideç BlowAirOverElectricPartsç Check Electric Connection Tighteningç Clean Fan Wheelç Check Fan Tighteningç Clean Drain Pansç
* Increase frequency in dusty zones.
{ Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual
S
S S S S S S
Table 2—Troubleshooting
PROBLEM POSSIBLE CAUSE SOLUTION
Unit/System Does Not Work The circuit breaker has tripped or a fuse
has blown.
Power failure.Diagnostic lights illuminate.*Voltage is too low.
Cooling is Not Working Properly
The filter is blocked with dust.Temperature is not set properly.A window or door is open.The outdoor unit is obstructed.The fan speed is too low.The operation mode is in Fan instead of
Cool.
Heating is Not Working Properly
The filter is blocked with dust.Temperature is set too low.A window or door is open.The outdoor unit is obstructed.
Unit Stops During Operation The Off timer is not operating correctly.
Diagnostic lights illuminate.*
* Diagnostic lights are a combination of lights that will illuminate in the display area on the unit. They are a combination of the lights you see during normal
operation.
Reset the circuit breaker or replace the fuse with
the specified replacement fuse.
Restart operation when the power is restored.Call your service representative.Call your service representative.
Clean the air filter.Check the temperature and reset if necessary.Close the window or door.Remove the obstruction.Change the fan speed selection.Change the operating mode to Cool or reset the
unit.
Clean the air filter.Check the temperature and reset if necessary.Close the window or door.Remove the obstruction.Restart the operating mode.Call your service representative.