Carrier 40MBQB18D3 User Manual

40MB*D Ducted Heat Pump Split System Sizes 09 to 48
Owner's Manual
TABLE OF CONTENTS
A NOTE ABOUT SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IMPORTANT SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
PARTS NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
REMOTE CONTROL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
REMOTE CONTROL FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
USING THE REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
AIR CONDITIONER OPERATIONS AND PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
HINTS FOR ECONOMICAL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
SAFETY PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
SUMMARIZE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. . . . . . . . . . . . . . 28
FUNCTION SUMMARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
NAME AND FUNCTION OF INDICATORS ON THE WIRE CONTROLLER.. . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . 29
INSTALLATION METHOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . 30
NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROL- LER. . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . 31
USING METHOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . 33
TECHNICAL INDICATION AND REQUIREMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PAGE
NOTE TO EQUIPMENT OWNER:
Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
INSTALLATION INFORMATION
Date Installed _____________________________
DEALERSHIP CONTACT INFORMATION
Company Name: _________________________________ Address:_________________________________________ ________________________________________________ Phone Number:__________________________________ Technician Name:_________________________________ ________________________________________________
A NOTE ABOUT SAFETY
Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution:
DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards that could result in personal injury or death.
CAUTION is used to identify unsafe practices which could result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
Model Numbers
Unit Tons Unit Btuh
0.75 9,000 1
1.5
12,000 18,000
24,000 40MBQB24D--3208/230-12 36,000 40MBQB36D--3208/230-13
48,000 40MBQB48D--3208/230-14
Volt- Ph @
60Hz
Indoor Model
Number
208/230-1 40MBQB09D--3 208/230-1 208/230-1
40MBQB12D--3 40MBQB18D--3
!
PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or service agency must use factory--authorized kits or accessories when modifying this product.
Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.
WARNING
Model number Nomenclature
40 MA Q B 09 B - - 3
Digi ts 10, 11 - b lank
Digi t 12 indi cates v oltage 1 = 115/ l/60 3 = 208- 230-1 -60Hz
Digi t 9 - Indoo r Fa n Coil Un it Type B = High -Wa ll C = Cass ette D = Duct ed F = Cons ole G = Unde rceil ing H = High Wal l Color Varia tion
- = Outd oor
Digi ts 7, 8 ind icate t he system' s capac ity in 10 00 BTU/ Hr
Exam ple: 09 = 9 000 BTU /Hr
Maxi mum Num ber of fa n coil units c onnec ted to th e outdo or unit B = 1:1
Digi t 5 indic ates th e system's t ype: C = Cool ing onl y; Q = Heat p ump
Digi ts 3 and 4 re prese nt the mo del
The fi rst two d igits i ndicate th e equip ment ty pe. 40 = Ind oor uni t; 38 = Out door un i
2
INDOOR UNIT
OUTDOOR UNIT
2
4
1
5
M
INDOOR UNIT
3
6
9
7
10
(A)
8
Fig.1
OUTDOOR UNIT(A,B,C)
Air outlet
1
Air inlet
2
Air filter(on some models)
3
Electric control cabinet
4
Wire controller(on some models)
5
Drain pipe
6
Connecting pipe
7
Air inlet
8 9
Air inlet(side and rear)
Air outlet
10
NOTE
All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model).The actual shape shall prevail.
3
1. IMPORTANT SAFETY INFORMATION
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The safety precautions listed here are divided into two categories. In either case, important safty information is listed which must be read carefully.
WARNING
Do not expose your body to the air flow for a long time.
Do not insert fingers, rods or other objects into the air inlet or outlet.
When the fan is rotating at high speed, it will cause injury.
Never use a flammable spray such as hair spray,lacquer or paint near the unit.
It may cause a fire.
Never touch the air outlet or the horizontal blades while the swing flap is in operation.
Fingers may get caught or the unit may break down.
The appliance shall be installed in accordance with national wiring regulations.Failure to observe a warning may result
in death.
CAUTION
Failure to observe a caution may result in injury or damage to the equipment.
WARNING
Ask your dealer for installation of the air conditioner.
Incomplete upgrades may result in a water leakage, electric shock, and fire.
Ask your dealer for upgrades, repair, and maintenance. Incomplete improvement, repair, and maintenance may result in a water leakage, electric shock, and fire.
In order to avoid electric shock, fire or injury, or if you detect any abnormality such as a burning smell, turn off the power supply and call your dealer for instructions.
Never let the indoor unit or the remote controller get wet.
It may cause an electric shock or a fire.
Never press the button of the remote controller with a hard, pointed object.
The remote controller may be damaged.
Never replace a fuse with that of another rate or other wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break down or cause a fire.
Never put any objects into the air inlet or outlet. Objects touching the fan at high speed can be dangerous.
Never inspect or service the unit. Ask a qualified service person to perform this work.
Do not dispose this product as unsorted municipal waste.Collection of such waste separately for special treatment is necessary.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
To prevent refrigerant leak, contact your dealer.
When the system is installed and operates in a small room, it is required to maintain the concentration of the refrigerant, below the limit. Otherwise, oxygen in the room may be affected, resulting in a serious accident.
The refrigerant in the air conditioner is safe and normally does not leak.
If the refrigerant leaks in the room, and comes in contact with a fire of a burner, a heater or a cooker the refrigerant leak may transform in to a harmful gas.
Turn off any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit.
Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired.
CAUTION
Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, animals or works of art.
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord.
Otherwise, an electric shock and injury may result.
In order to avoid electric shock or fire, make sure that an earth leak detector is installed.
Be sure the air conditioner is grounded.
In order to avoid electric shock, make sure that the unit is grounded and that the earth wire is not connected to gas or water pipe, lightning conductor or telephone earth wire.
4
In order to avoid injury, do not remove the fan guard of the outdoor unit.
Do not operate the air conditioner with a wet hand.
An electric shock may happen.
Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.
Do not place items which might be damaged by moisture under the indoor unit.
Condensation may form if the humidity is above 80%, the drain outlet is blocked or the filter is polluted.
After a long use, check the unit stand and fitting for damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used together with the air conditioner.
Arrange the drain hose to ensure smooth drainage.
Poor drainage may cause wetting of the building, furniture etc.
Never touch the internal parts of the controller. Do not remove the front panel. Some parts inside are dangerous to touch, and the unit may be damaged.
Never expose little children, plants or animals directly to the air flow.
Adverse influence to little children, animals and plants may result.
Do not allow a child to mount on the outdoor unit or avoid placing any object on it.
Falling or tumbling may result in injury.
Do not operate the air conditioner when using a room fumigation - type insecticide.
Failure to observe could cause the chemicals to deposit in the unit, which could endanger the health of those who are hypersensitive to chemicals.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
2. PARTS NAMES
The air conditioner consists of the indoor unit, the outdoor unit, the connecting pipe and the remote controller.
(Refer to Fig.2-1)
Function indicators on indoor unit display panel
Temporary button
Operation lamp
For the inverter type,this switch is used for after-sales service purposes only,the user should not select it.
PRE-DEF indicator(cooling and heating type) or fan only indicator(cooling only type)
Infrared signal receiver
Display Digital tube
Timer indicator
Display panel
Alarm indicator
Fig.2-1
Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit.
It may cause incomplete combuston or deformation of the unit due to the heat.
Do not install the air conditioner at any place where flammable gas may leak out.
If the gas leaks out and remains around the air conditioner, a fire may break out.
The appliance is not intended for use by young children or infirm persons without supervision.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
For fixed-frequency type,
temporarily in case you misplace the remote controller or its batteries are exhausted. Two modes including AUTO and FORCED COOL can be selected through the TEMPORARY BUTTON on the air-in grill control box of the indoor unit. Once you push this button, the air conditioner will run in such order: and back to
FORCED AUTO
1
The OPERATION lamp is lit, and the air conditioner will run under FORCED AUTO mode. The remote controller operation is enabled to operate according to the received signal.
2
FORCED COOL The OPERATION lamp flashes, the air conditioner will turn to FORCED AUTO after it is enforced to cool with a wind speed of HIGH for 30 minutes. The remote controller operation is disabled.
3
OFF The OPERATION lamp goes off. The air conditioner is OFF while the remote controller operation is enabled.
FORCED
this function is used to operate the unit
FORCED
FORCED
AUTO.
AUTO, FORCED COOL, OFF,
NOTE
This manual does not include Remote Controller Operations, see the<<Remote Controller Owner's manual>> packed with the unit for details.
5
4. REMOTE CONTROL FUNCTIONS
7
8
9
5. USING THE REMOTE CONTROL
10111213141516
17
18
6. AIR CONDITIONER OPERATIONS AND PERFORMANCE
Use the system in the following temperature for safe and effective operation.The max operation temperature for the air conditioner.(Cooling/Heating)
Table 2-1
Temperature
Mode
Cooling operation
Heating operation
(cooling only type without)
Dry operation
(for the models with low temperature cooling system)
Outdoor temperature
32 °F~122°F / 0°C ~ 50°C
5 °F~122°F / -15°C ~ 50°C
5 °F~76°F / -15°C ~ 24°C
32 °F~122°F / 0°C ~ 50°C
NOTE
Room
temperature
62°F ~90°F (17°C~32°C)
32°F~86°F (0°C~30°C)
62°F ~90°F (17°C~32°C)
7. HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical operation. (Refer to corresponding chapterfor details)
Adjust the air flow direction properly to avoid winding toward your body.
Adjust the room temperature properly to get a comfortable situation and to avoid supercooling and superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or windows more often than necessary.
Set the timer for the desired operating time.
Never put obstructions near the air outlet or the air inlet. Or it will cause lower efficiency, even a sudden stop.
Adjust the air flow direction properly to avoid winding toward your body.
1
If air conditioner is used outside the above conditions, it may cause the unit to function abnormally.
2
Is it normal for condensation to form on the unit when the relative humidity in a room is high. Close the door and windows to help reduce the condensation. Optimum performance will be achieved within these
3
operating temperature range.
Three-minute protection feature
A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it restarts immediately after operation.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start flashing when power is restored. To restart operation, push the ON/OFF button on the remote controller. Lightning or a mobile telephone operating nearby may cause the unit to malfunction.
Disconnect the unit with the power and then connect the unit with the power again. Push the ON/OFF button on the remote controller to restart operation.
Adjust the room temperature properly to avoid supercooling and superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or windows more than necessary.
If you don't plan to use the unit for a long time, please disconnect power and remove the batteries from the remote controller. When the power switch is connected, some energy will be consumed, even if the air conditioner isn't in operation. So please disconnect the power to save energy. And please switch the power on 12 hours before you restart the unit to ensure a smooth operation.
A clogged air filter will reduce cooling or heating efficiency, please clean it once two weeks.
8
. MAINTENANCE
CAUTION
Before you clean the air conditioner, be sure the power supply is off.
Refrigerant Leakage Detection(optional):
,
With this new technology, the display area will display EC (if applicable) and the LED indication lamps continue flashing when the outdoor unit detects refrigerant leakage.
,
Check to see if wiring is broken or disconnected.
Use a dry cloth to wipe the indoor unit and remote controller.
A wet cloth may be used to clean the indoor unit if it is very dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically-treated duster for wiping or leave such material on the unit for long because. it may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform.
19
Maintenance after a long stop period
Check and remove everything that might be blocking inlet and outlet vents of indoor units and outdoor units.
Clean air filters and casings of indoor units. Refer to "Cleaning the air filter" for details on how to proceed and make sure to install cleaned air filters back in the same position.
Check and remove everything that might be blocking inlet and outlet vents of indoor units and outdoor units.
Clean air filters and casings of indoor units. Refer to "Cleaning the air filter" for details on how to proceed and make sure to install cleaned air filters back in the same position. Turn on the power at least 12 hours before operating the unit in order to ensure smoother operation. As soon as he power is turned on, the remote controller displays appear.
Maintenance before a long stop period
Let the indoor units run in fan only operation for about half a day in order to dry the interior of the units.
Clean air filters and casings of indoor units. Refer to " Cleaning the air filter" for details on how to proceed and make sure to install cleaned air filters back in the same position.
If your unit is a descensional ventilated model, please push the filter up slightly to let the position retainer move away from the flange fixed holes, and take off the filter according to the arrow direction shows in the following fig.
Fig.5-2
Cleaning the air filter(on some models)
The air filter can prevent dust or other particulate from entering the unit. In case of blockage of the filter, the working efficiency of the air conditioner may greatly decrease. Therefore, the filter must be cleaned once every two weeks during long time usage.
If the air conditioner is installed in a dusty place , clean the the air filter frequently.
If the accumulated dust is too heavy to be cleaned , please replace the filter with a new one(replaceable air filter is an optional fitting).
If your unit is a rear ventilated model, please remove the filter fixed screws2 screwsand pull the filter away from the unit.
Clean the air filter (vacuum cleaner or pure water may be used to clean the air filter. If the dust accumulation is too heavy , please use asoft brush and mild detergent to clean it and dry out in cool place) .
Fig.5-3
Fig.5-1
Fig.5-4
20
The air-in side should face up when using vacuum cleaner. (Refer to Fig.5-4) The air-in side should face down when using water. (Refer to Fig.5-3)
Symptom 3.2: Indoor unit, outdoor unit
When the system is changed over to heating operation after defrost operation moisture generated from defrosting becomes steam and is exhausted.
CAUTION
Do not dry out the air filter under direct sunshine or with fire.
5. Re-install the air filter
6. Install and close the air-in grill in the reverse order of step 1 and 2 and connect the control box cables to the corresponding terminators of the main body .
9.
FOLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES
Symptom 1: The system does not operate
The air conditioner does not start immediately after the ON/OFF button on the romote controller is pressed. If the operation lamp lights, the system is in normal condition.To prevent overloading of the compressor motor, the air conditioner starts 3 minutes after it is turned ON.
If the operation lamp and the " heating type) or fan only indicator(cooling only type)" means you choose the heating model, When just starting, if the compressor has not started, the indoor unit appears "anti cold wind" protection because of its overlow outlet temperature.
PRE-DEF indicator(cooling and
light, it
Sptom 4: Noise of air conditionerscooling
Symptom 4.1: Indoor unit
A continuous low "shah" sound is heard when the system is in cooling operation or at a stop. When the drain pump (optional accessories) is in operation,this noise is heard.
A "pishi-pishi" squeaking sound is heard when the system stops after heating operation. Expansion and contraction of plastic parts caused by temperature change make this noise.
Symptom 4.2: Indoor unit, outdoor unit
A continuous low hissing sound is heard when the system is in operation. This is the sound of refrigerant gas flowing through both indoor and outdoor units.
A hissing sound which is heard at the start or immediately after stopping operation or defrost operation. This is the noise of refrigerant caused by flow stop or flow change.
Symptom 4.3: Outdoor unit
When the tone of operating noise changes. This noise is caused by the change of frequency.
Symptom 2: Change into the fan mode during cooling mode
In order to prevent the indoor evaporator frosting, the system will change into fan mode automatically, restore to the cooling mode after soon.
When the room temperature drops to the set temperature, the compressor goes off and the indoor unit changes to fan mode; when the temperature rises up, the compressor starts again. It is same in the heating mode.
Symptom 3: White mist comes out of a unit
Symptom 3.1: Indoor unit
When humidity is high during cooling operation If the interior of an indoor unit is extremely contaminated, the temperature distribution inside a room becomes uneven. It is necessary to clean the interior of the indoor unit. Ask your dealer for details on cleaning the unit. This operation requires a qualified service erson
Symptom 5: Dust comes out of the unit
When the unit is used for the first time in a long time. This is because dust has gotten into the unit.
Symptom 6: The unit can emit odors
The unit can absorb the smell of rooms, furniture, cigarettes, etc., and then emit it again.
Symptom 7: The outdoor unit fan does not spin.
During operation. The speed of the fan is controlled in order to optimize product operation.
21
TROUBLESHOOTING
10.
7.1. Troubles and causes of air conditioner
If one of the following malfunctions occur, stop operation, shut off the power, and contact with your dealer.
The operation lamp is flashing rapidly (5Hz). This lamp is still flashing rapidly after you turn off the power and turn it on again. (Refer to Table 7-1 and Table 7-2)
Remote controller receives malfunction or the button does not work well.
A safety device such as a fuse, a breaker frequently actuates.
Obstacles and water enter the unit.
Water leaks from indoor unit.
Other malfunctions.
If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident, investigate the system according to the following procedures. (Refer to Table 7-3)
CAUTION
Please cut off the power supply when appearing the above malfunction, check if the voltage provided is out of range, check if the installation of air-conditioner is correct, then electrify again after 3 minutes power off. If the problem is still existent, please contact the local service station or the equipment provider.
22
Table 7-1
NO.
Indoor EEPROM error
1
Communication malfunction
2
between indoor and outdoor units
Indoor fan speed malfunction
3
Indoor room temperature sensor
4
open circuit or short circuit
Evaporator coil temperature
5
sensor open circuit or short circuit
Refrigerant leakage detection
6
malfunction
Water-level alarm malfunction
7
Communication malfunction between two indoor units (for
8
twins model)
Other malfunction of twins model
9
Current overload protection
10
Outdoor room temperature sensor
11
open circuit or short circuit
Outdoor condenser pipe
12
temperature sensor error
Discharging air temperature
13
sensor error
Outdoor EEPROM error
14
Outdoor fan speed malfunction
15
(Only for DC fan motor)
T2b sensor error
16
Inverter module IPM protection
17
18
High/Low voltage protection
High temperature protection of
19
compressor top
Outdoor low temp. protection
20
Compressor drive error
21
Mode conflict
22
Malfunction Timer lamp
Display (nixie tube)
E0
E1
E3
E4
E5
EC
EE
E8
E9
F0
F1
F2
F3
F4
F5
F6
P0
P1
P2
P3
P4
P5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
Flash
Flash
Flash
Flash
Flash
Flash
Running lamp (flashes per second)
1
2
4
5
6
7
8
9
10
1
2
3
4
5
6
7
1
2
3
4
5
6
23
Table 7-2
Symptoms Causes
Unit does not start
Air flowing normally however unit is not cooling cooling
Units starts or stops frequently
Low cooling effect
Power failure. Power switch is off. Fuse of power switch may have burned. Batteries of remote controller exhausted or other problem of controller.
Temperature is not set correctly. Unit is in 3 minutes protection mode for the compressor.
Refrigerant is too low or too high. Air or no concentrating gas in the refrigerating circuit. Compressor is malfunction. Voltage is too high or too low. System circuit is blocked.
Outdoor unit and indoor unit heat exchanger is dirty. The air filter is dirty. Inlet/outlet of indoor/outdoor units is blocked. Doors and windows are open Direct sunlight on unit. A strong heat source nearby. heat resource. Outdoor temp. is too high. Leakage of refrigerant or lack of refrigerant.
Solution
Wait for the return of power. Switch on the power. Replace the fuse. Replace the batteries or check the controller.
Set the temperature properly. Wait.
Check leakage, and rightly recharge refrigerant. Vacuum and recharge refrigerant. Maintenance or change compressor. Install manostat. Find reasons and solution.
Clean the heat exchanger. Clean the air filter. Eliminate all dirt. Close doors and windows. Adjust curtains to shelter unit from sunshine. Reduce heat source. AC cooling capacity reduces (normal). Check leakage and rightly recharge refrigerant.
Low heating effect
Outdoor temperature is lower than
44.6˚F/7˚C Doors and windows not completely closed. Leakage of refrigerant or lack of refrigerant.
Use heating device. Close doors and windows. Check leakage and rightly recharge refrigerant.
24
7.2. Troubles and causes of wire controller
Before asking for serving or repairing , check the following points. (Refer to Table 7-3)
Table 7-3
Symptoms
The fan speed can not be changed.
The wire controller signal is not transmitted even when the ON/OFF button is pushed.
The TEMP. indicator does not come on.
The indication on the display disappears after a period of time.
The TIMER ON indicator goes off after a period of
certain time.
Solution
Check whether the MODE indicated on the display is "AUTO"
Check whether the MODE indicated on the display is "DRY"
Check whether the signal transmitter of the wire controller is properly directed to the infrared signal receiver of the indoor unit.
Check whether the MODE indicated on the display is FAN ONLY
Check whether the timer operation has come to an end when the TIMER OFF
is indicated on the display.
Check whether the timer operation is started when the TIMER ON is indicated
on the display.
Causes
When the automatic mode is selected, the air conditioner will automatically change the fan
speed.
When dry operation is selected, the air conditioner automatically
change the fan speed. The fan speed can be selected during "COOL" , "FAN ONLY",
The power supply is off.
The temperature cannot be set during FAN mode.
The air conditioner operation will stop at the set time
Up to the set time, the air conditioner will automatically
start and the appropriate indicator will go off.
and
"HEAT"
Not receiving tone sounds from the indoor unit even when the ON/OFF button is
pressed.
Check whether the signal transmitter of the wire controller is properly directed to the infrared signal receiver of the indoor unit when the ON/OFF button is pressed.
Directly transmit the signal transmitter of the wire controller to the
infrared signal receiver of the indoor unit, and then repeatly push the ON/OFF button twice.
25
● This manual gives detailed description of the precautions that should be brought to your attention during operation.
● In order to ensure correct service of the wired controller please read this manual carefully before using the unit.
● For convenience of future reference, keep this manual after reading it.
● The wired controller will reset to factory setting with auto mode, auto fan and 76°F(24°C) setting temperature when the air conditioner restarts after power failure. And this may cause inconsistent displays on the wired controller and on the air conditioner. You need to readjust the running status through the wired controller.
26
11. SAFETY PRECAUTIONS
The following contents are stated on the product and the operation manual,
including usage, precautions against personal harm and property loss, and the
methods of using the product correctly and safely. After fully understanding the
following contents (identifiers and icons), read the text body and observe the
following rules.
Identifier description
Identifier Meaning
Means improper handling may lead to personal injury or
Warning
Caution
Means improper handling may lead to personal death or severe injury.
property loss.
[Note]: 1. “Harm” means injury, burn and electric shock which need long-term treatment but need no hospitalization
2. “Property loss” means loss of properties and materials.
Icon description
Meaninglcon
It indicates forbidding. The forbidden subject-matter is indicated in the icon or by images or characters aside.
It indicates compulsory implementation. The compulsory subject-matter is indicated in the icon or by images or characters aside.
27
Warning
W
arning
Delegate
installation
Please entrust the distributor or professionals to install the unit. The installers must have the relevant know-how. Improper installation performed by the user without perm ission may cause fire, electric,shock, personal injury or water leakage.
Do not spray flammable aerosol to the wire controller directly. Otherwise, fire may occur.
Do not operate with wet hands or let water enter the wire controller. Otherwise, electric shock may occur.
Usage
W
arning
Forbid
Forbid
12. SUMMARIZE
Usage condition:
1. Power supply: 5V DC.
2. Operation temperature:
-5°F(-15°C)~ +109°F(+43°C).
3. Operation humidity: 40%-90%, RH.
13. FUNCTION SUMMARY
Main function:
1. Connecting to indoor unit by A, B, C,
D, E termina.;
2. Button setting action mode.
3. LCD display.
4. Timer for rest time.
28
14. NAME AND FUCTION OF INDICATORS ON THE CONTROLLER
1
2
Timer ON/OFF
Operation mode indication
1
2
1 121 12
Lock
6
Temperature display zone
7
3
Follow me function
4
ON/OFF indication
5
Fan speed indication
Operation mode indication:
When press " MODE " button, the follow-
ing mode can be selected in circle. Auto
→Cool →Dry→Heat→Fan only→Auto.
For cooling only model,heat mode is
skipped. Timer :
When adjust setting on time or only on
time is set, the "ON" is lighted.
When adjust setting off time or only off
time is set , the "OFF" is lighted. If on
and off timer are both set, the"ON" and
"OFF"are both lighted. Follow me function:
There is a temperature sensor inside the
wire controller, after setting temperature,
it will compare the two temperatures,
and the space of wire controller will be
29
the same as setting temperature. It is
speed.
available under cooling, heating, auto
mode. ON/OFF indication :
When it is on, the icon display, other-
wise it is extinguished. Fan speed indication :
There are four fan modes : low, middle,
high, auto. For some models, no middle
fan then the middle fan is seen as high
15. INSTALLATION METHOD
5-way terminal
Lock:
When the " LOCK " button is pressed,
the icon appear and other buttons is
unable, press again, the icon disappear. Temperature display zone:
Generally it displays setting tempera-
ture, it can be adjusted by press tem-
perature button ▲ and ▼. But in fan
mode, no display here.
Emitter tube
Wire Controller
5-Core Shield Cable
RUN
Indoor switch board
Indoor Unit
+5V
GND
30
When a wire controller is needed, a small 5-way terminal should be added,fix an infra-
red emitter with gumwater near the receiver on the switch board. Connect its anode
and cathode to A and B,and +5V, GND, RUN to C, D, E on the switch board.
16. NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER
MODE BUTTON
TIMER ON BUTTON
TIMER OFF BUTTON
FOLLOW ME BUTTON
ELECTRICAL HEATER BUTTON
RESET BUTTON
TIMER
ON
TIMER
OFF
FOLLOW
ME
AUXIL
HEATER
MODE
RESET
NOTE
LOCK
FANSPEED
ECO
SWING
TEMP
11
12
13
ON / OFF BUTTON
ADJUST BUTTON ▲
ADJUST BUTTON ▼
SWING BUTTON
ECONOMY BUTTON
FAN SPEED BUTTON
LOCK BUTTON
All the pictures in this manual are for explanation purpose only. There may be
slightly different from the wire controller you purchased(depend on model). The
actual shape shall prevail.
31
Mode botton:
mode. Pressing the FOLLOW ME button
When press this botton,the operation
mode change as the following
sequence:
→AUTO → COOL→DRY→HEAT→FAN
Remark: For the cooling only model, the
heating mode is skipped. Timer on button :
Press this button, timer on function is
active. Then every press, the time
increase 0.5h, after 10h, 1h increase-
ment after each press. If cancel this
Function, just set it to "0.0" . Timer off button:
Press this button, timer off function is
active.Then every press, the time
increase 0.5h, after 10h, 1h increase-
ment after each press. If cancel this
function, just set it to "0.0" . Follow me button :
When under cool, heat and auto mode,
press this button, follow me function is
active. Pressing the ON/OFF button or
MODE button will not cancel the Follow
me feature. This function is disable
when the unit is off or under DRY or FAN
again will cancel the follow me feature. Electrical heater button :
If press this button in heat mode, electri-
cal heater function become ineffective. Reset button(hidden):
Use a 1mm stick to press in the little hole,
then the current setting is canceled. The
wire controller enter into original state. ON/OFF button:
When in off state, press this button, the
indicator is on, the wire controller enter
into on state, and send setting information
to in door Pcb. When in on state,press this
button, the indicator is off, and send
instruction. If timer on or timer off has
been set, it concel this setting then send
instruction to stop the machine. Adjust button ▲:
Set indoor temperature up. If press and
hold on, it will increase at 1°F(1°C) per
0.5 second. Adjust button ▼ :
Set indoor temperature down. if press and
hold on, it will decrease at 1°F(1°C) per
0.5 second.
32
Swing button:
First press, start swing function;second
press, stop swing. (Match to some
17. USING METHOD
AUTOMATIC OPERATION
model with swing function).
11 Economy operation button :
press this button, the indoor unit oper-
ates in economy mode, press again, exit
this mode (it may be ineffective for some
models)
12 Fan speed button:
press this button consecutively, the fan
speed will circle as follow:
13 Lock button(hidden):
When you push the LOCK button, all
current settings are locked in and the
wire controller does not accept any oper-
ation except that of the LOCK button.
Use the lock mode when you want to
prevent setting from being changed
Connect to power,indoor operation lamp
flash.
1. Press "MODE" button, select " AUTO " ;
2. Press the button "▲" and "▼", set tem-
perature you want, generally it is among
62°F(17°C)~86°F(30°C);
3. Press " ON/OFF" button, operation
lamp is on, the air-conditioner work in auto
mode, indoor fan is auto, and can not be
changed. Auto is displayed on LCD. Press
ON/OFF button again to stop.
4. Economy operation is valid in auto
mode.
5. In event of power interruption such as a
blackout, the air conditioner stops once.
But it restarts automatically and performs
previous operation when the power supply
is resumed.
accidentally or play fully. Push the
LOCK button again when you want to
cancel the LOCK mode.
33
COOL/HEAT/FAN MODE OPERA­TION
1. Press "MODE" button, select "COOL"
, "HEAT" or "FAN ONLY" mode.
2. Press temperature adjust button to
select setting temp.
3. Press "FAN SPEED" button to select
high/mid/low/auto.
4. Press "ON/OFF" button, indoor unit
operation lamp on, it works in selected
mode. Press "ON/OFF" button again, it
stops to work.
Remark: When in fan mode, no tempera-
ture can be set.
TIMER SETTING
Timer on only:
1. Press " TIME ON " button, it display
"SET" on LCD, and display " H " and "ON"
, it is waiting for timer on setting.
2. Press " timer " on button repeatedly to
adjust time setting.
3. If press this button and hold on, the
time will increase at 0.5h, after 10h, it
increase at 1h.
4. After setting 0.5 second, the wire con-
troller send timer on information, it is
finished.
Timer off only:
DRY OPERATION
1. Press " MODE " button, select " DRY "
mode.
2. Press temperature adjust button to
select setting temp.
3. Press " ON/OFF " button, indoor unit
operation lamp on, it works in dry mode.
Press ON/OFF button again, it stops to
work.
4. In dry mode, economy operation and
fan speed are ineffective.
1. Press "TIME OFF " button, it display
"SET" on LCD, and display " H " and ON,
it is waiting for timer on setting.
2. Press "TIME OFF" button repeatedly to
adjust time setting.
3. If press this button and hold on , the
time will increase at 0.5h, after 10h, it
increase at 1h.
4. After setting 0.5 second, the wire con-
troller send timer off information, it is
finished.
34
TIMER ON AND TIMER OFF BOTH
18. TECHNICAL INDICA-
1. Set timer on time as the correspond-
ing step1 and 2.
2. Set timer off time as the correspond-
ing step1 and 2.
3. Timer off time must be longer than
timer on time.
4. 0.5 second after setting, the wire con-
troller send information.the setting is
finished.
CHANGE TIMER
If there is a need of changing timer
time, press corresponding button to
revise it. If concel timer, change timer
time to 0.0.
TION AND REQUIRE­MENT
EMC and EMI comply with the CE
certification requirements.
NOTE
The timer time is relative time,that is
delay after setting time( i, e: setting
time is 8:05 A,M). So when imer is set,
the standard time can not be adjusted.
5
3