Carrier 40MBQB09D3 User Manual

40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48
Product Data
INDUSTRY LEADING FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 40MBD series ducted split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted in the ceiling. This selection of fan coils permits creative solutions to design problems such as:
S Add- ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S Historical renovations or any application where
preserving the look of the original structure is essential.
These compact indoor fan coil units take up very little space above the ceiling. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.
LOW SOUND LEVELS
When sound ordinances and proximity to neighbors demand quiet operation, the 38MAQ unit is the right choice: The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MAQ units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ducted split system is simple to install. A mounting bracket and duct work is needed for the indoor units, and only wire and piping need to be run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 40MBD / 38MAQ / 38MBQ ducted split systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw- thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy accessible service panels. In addition, these ducted systems have extensive self- diagnostics to assist in troubleshooting.
BUILT- IN RELIABILITY
Ducted split system indoor and outdoor units are designed to provide years of trouble- free operation.
The ducted indoor units include protection against freeze- up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor will start the over- current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year- round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ducted split system design allows individual or multi- room heating or cooling when required. There is no need to run large supply- air fans or chilled water pumps to handle a few spaces with unique load patterns.
EASY- TO- USE CONTROLS
The ducted units have microprocessor- based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote control provides the interface between user and the unit.
CONDENSATE PUMP
Factory installed condensate pump on the ducted fan coil provides installation flexibility.
STANDARD WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.
2
MODEL NUMBER NOMENCLATURE
INDOOR UNIT
40 MB 309
40= FAN COIL UNIT
MB =MODEL
SYSTEM TYPE Q =HEATPUMP
MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT B=1:1
NOMINAL CAPACITY 09 -3/4TON 12 -1TON 18 -1-1/2TONS 24 -2TONS 36 -3TONS 48 -4TONS
BQD
--
VOLTAGE 3 = 208/230- 1 - 60
NOT USED
INDOOR FAN COIL TYPE
D =DUCTED
38 MA 309
38 = OUTDOOR UNIT
MA =MODELSIZES09- 24 MB =MODELSIZES36- 48
SYSTEM TYPE Q =HEATPUMP
MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT B=1:1
NOMINAL CAPACITY 09 -3/4TON 12 -1TON 18 -1-1/2TONS 24 -2TONS 36 -3TONS 48 -4TONS
OUTDOOR UNIT
BQ-
--
VOLTAGE 3 = 208/230- 1 - 60
NOT USED
UNIT TYPE
- = OUTDOOR UNIT
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org.
3
STANDARD FEATURES AND ACCESSORIES
Ease Of Installation
Mounting Brackets S Low Voltage Controls S
Comfort Features
Microprocessor Controls S Wired Remote Control S Wireless Remote Control S Automatic Horizontal Air Sweep S Air Direction Control S Auto Restart Function S Cold Blow Protection On Heat Pumps S Freeze Protection Mode On Heat Pumps S Turbo Mo d e S Silence Mode S Auto Changeover On Heat Pumps S
Follow Me S
Energy Saving Features
Sleep Mode S Stop/Start Timer S
46° F Heating Mode (Heating Setback)
Safety And Reliability
3MinuteTimeDelayForCompressor S Over Current Protection For Compressor S Indoor Coil Freeze Protection S Indoor Coil High Temp Protection in Heating Mode S Condenser High Temp Protection in Cooling Mode S
Ease Of Service And Maintenance
Cleanable Filters S Diagnostics S Liquid Line Pressure Taps S
Application Flexibility
Condensate Pumps S Crankcase Heater S
Legend
SStandard A Accessory
S
OUTDOOR UNITS
Crankcase Heater
Standard on all unit sizes. Heater clamps around compressor oil stump.
4
DIMENSIONS - INDOOR
Fig. 1 – Indoor unit
Outline dimensions Air outletopening size Air return opening size
Size A B C D E F G H I J K L M H1 H2 W1 W2
27.6
9
(700)
27.6
12
(700)
36.2
18
(920)
36.2
24
(920)
44.8
36
(1140)
47.2
48
(1200)
8.2
(210)25(635)
8.2
(210)25(635)
8.2
(210)25(635)
10.6
(270)25(635)
10.6
11.8
30.5
(775)
34.1
(865)
(270)
(300)
22.4
(570)
22.4
(570)
22.4
(570)
22.4
(570)
27.9
(710)
31.4
(800)
2.5 (65)
2.5 (65)
2.5 (65)
2.5 (65)
2.5 (65)
3.1 (80)
19.4
(493)
19.4
(493)
19.4
(493)
19.4
(493)
36.7
(933)
38.1
(968)
1.3 (35)
1.3 (35)
1.3 (35)
1.3 (35)
1.3 (35)
1.5 (40)
4.6
(119)
4.6
(119)
4.6
(119)
7.0
(179)
7.0
(179)
8.0
(204)
23.4
(595)
23.4
(595)
32.0
(815)
32.0
(815)
40.7
(1035)
43.0
(1094)
7.8
(200)
7.8
(200)
7.8
(200)
10.2
(260)
10.2
(260)
11.3
(288)
3.1 (80)
3.1 (80)
3.1 (80)
0.7 (20)
1.7 (45)
1.7 (45)
Brackets
29.1
(740)
29.1
(740)
37.8
(960)
37.8
(960)
48.8
(1240)
48.8
(1240)
Hanger
13.8
(350)
13.8
(350)
13.8
(350)
13.8
(350)
19.7
(500)
19.7
(500)
Refrigerant Pipe Locations
4.7
5.6
(143)
5.6
(143)
5.6
(143)
5.6
(143)
5.6
(143)
7.8
(198)
3.7 (95)
3.7 (95)
3.7 (95)
3.7 (95)
3.7 (95)
6.1
(155)
(120)
4.7
(120)
4.7
(120)
4.7
(120)
4.7
(120)
6.9
(175)
5.9
(150)
5.9
(150)
5.9
(150)
5.9
(150)
5.9
(150)
8.3
(210)
5
DIMENSIONS - OUTDOOR
Fig. 2 – Outdoor unit
Unit Size W in (mm) D in (mm) H in (mm) L1 in (mm) L2 in (mm)
9K 31.8(810) 12.2(310) 21.9(558) 21.6(549) 12.8(325) 82.4(37.4) 12K 31.8(810) 12.2(310) 21.9(558) 21.6(549) 12.8(325) 82.4(37.4) 18K 33.2(845) 12.6(320) 27.5(700) 22.0(560) 13.1(405) 102.5(46.5) 24K 37.2(945) 15.5(395) 31.8(810) 25.2(640) 15.9(405) 137.5(62.4) 36K 37.2(945) 15.5(395) 31.8(810) 25.2(640) 15.9(405) 137.5(62.4) 48K 36.93(938) 15.4(392) 53.9(1369) 24.9(634) 15.9(404) 220(100)
Operating
Weight lb (kg)
6
CLEARANCES - INDOOR
7.874in(200mm)
11.811in(300mm)
23.622in x 23.622in(600mm x 600mm)
Fig. 3 – Indoor Unit Clearance
CLEARANCES - OUTDOOR
A
D
UNIT
A 24 (609) B 24 (609) C 24 (609) D 4 (101) E 4 (101)
B
Air-outlet
Fig. 4 – Clearances Outdoor
Air-inlet
E
C
Minimum Value
in. (mm)
7
SPECIFICATIONS
Size 9 12 18 24 36 48
System
Performance
Controls
Operating
Range
Piping
Refrigerant
Outdoor
Indoor Coil
Compressor
Electrical
Outdoor
Indoor
Outdoor Model 38MAQB09---3 38MAQB12---3 38MAQB18---3 38MAQB24---3 38MBQB36---3 38MBQB48---3 Indoor Model 40MBQB09D--3 40MBQB12D--3 40MBQB18D--3 40MBQB24D--3 40MBQB36D--3 40MBQB48D--3 Energy Star YES YES YES YES NO NO Cooling Rated Capacity Btu/h 9,000 11,000 16,000 23,000 36,000 48,000 Cooling Cap. Range Min - Max Btu/h 3,500~11,000 4,000~13,000 4,500~18,000 5,500~24,500 8,500~38,000 9,000~50,000 SEER 19.0 18.0 18.5 19.0 15.5 16.5 EER 13.5 12.5 12.5 12.5 8.5 8.2 Heating Rated Capacity Btu/h 10,000 11,800 18,000 24,400 38,000 50,000 Heating Cap. Range Min - Max Btu/h 4,500~11,500 5,000~13,500 5,500~19,000 6,000~26,000 9,500~50,000 10,000~55,000 HSPF 9.6 9.0 9.6 10.5 10.5 10.0 Wireless Remote Controller(°F/°C Convertible) Standard Wired Remote Controll er (°F/°C Convertible) Standard Cooling OutdoorDB Min - Max °F 4~122 4~122 4~122 4~122 4~122 4~122 Heating OutdoorDB Min - Max °F 4~86 4~86 4~86 4~86 4~86 4~86 Total Piping Length Ft. 82 82 98 98 213 213
*
Piping Lift Pipe Connection Size -Liquid In. 1/4 1/4 1/4 3/8 3/8 3/8 Pipe Connection Size -Suction In. 3/8 1/2 1/2 5/8 5/8 5/8 Type R410A DesignPressure PSIG 550 550 550 550 550 550 MeteringDevice CapillaryTube inOutdoor Unit Charge Lbs. 2.76 2.76 4.19 5.18 7.5 9.48 Face Area Sq. Ft. 9.2 9.2 16.0 21.1 8.2 14.1 No. Rows 2 2 2 3 2.6 2.0
coil
Fins per inch 21 21 18 18 17 17.0 Circuits 4 4 6 8 6 10.0 Face Area Sq. Ft. 1.4 1.4 1.4 2.0 3.5 4.2 No. Rows 3 3 3 4 4 4 Fins per inch 16 16 16 16 16 16 Circuits 4 4 4 6 8 8 Type Hermetic Rotary DC Inverter Compressor Model AS M 98D1UFZA ASM108D1UFZA ASM135D23UFZ DA250S2C-30MT TNB306FPGMC-L MNB36FAAMC-L Oil Type VG74 VG74 VG74 VG74 FV50S FV50S Oil Charge Fl. Oz. 12.5 12.5 15.2 27.7 36.2 47.3 Rated Current RLA 5.3 5.7 7.3 8.8 13.5 13.5 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Power Supply Indoor unit powered from outdoorunit MCA A. 15 15 15 15 30 35 MOCP -Fuse Rating A. 15 15 20 25 50 55 Unit Width In. 31.9 31.9 33.3 37.2 37.2 36.9 Unit Height In. 22.0 22.0 27.6 31.9 31.9 53.9 Unit Depth In. 12.2 12.2 12.6 15.6 15.6 15.4 Net Weight Lbs. 82.4 82.4 120.5 134.0 160.9 220.0 Airflow CFM 945 945 1050 1390 2940 4240 Sound Pressure dB(A) 56 56 59 62 65 65 Unit Width In. 27.6 27.6 36.2 36.2 44.9 47.2 Unit Height In. 8.3 8.3 8.3 10.6 10.6 11.8 Unit Depth In. 25.0 25.0 25.0 25.0 30.5 34.1 Net Weight Lbs. 39.9 39.9 50.7 57.3 77.2 99.2 Number ofFan Speeds 3 3 3 3 3 3 Airflow (lowest tohighest) CFM 290/340/380 290/340/380 400/440/480 590/650/810 680/940/1180 940/1180/1470 Sound Pressure (lowest to highest) dB(A) 30/33/36 30/34/38 34/37/38 43/45/48 46/50/52 41/44/46 Max Static Pressure In.WG. 0.16 0.16 0.28 0.28 0.32 0.40
Ft. 32 32 65 65 98 98
8