Carrier 40MBCQ183 Specifications

40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18
Product Data
INDUSTRY LEADING FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 38/40MB*C series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The in- ceiling cassette fan coils are ideal for retrofit or modernization projects where a false ceiling is available. This selection of fan coils permits inexpensive and creative solutions to design problems such as:
S Add- ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.
LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38MAQ unit is the right choice: The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MAQ units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38/40MB*C ductless split systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw- thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy- to- use cleanable filters. In addition, these cassette systems have extensive self- diagnostics to assist in troubleshooting.
FACTORY INSTALLED BASEPAN HEATER
BUILT- IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation.
The in- ceiling cassette units include protection against freeze- up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor will start the over- current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year- round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply- air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts.
EASY- TO- USE CONTROLS
The in- ceiling cassette has microprocessor- based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit.
FACTORY INSTALLED CONDENSATE PUMP
Customizing these ductless split systems to your application is easily accomplished. The factory installed condensate pump on the cassette fan coil unit provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.
2
MODEL NUMBER NOMENCLATURE
INDOOR UNIT
40 B 309
40= FAN COIL UNIT
BQC
--
MB =MODEL
SYSTEM TYPE Q =HEATPUMP
MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT B=1:1
NOMINAL CAPACITY 09 -3/4TON 12 -1TON 18 -1-1/2TONS
38 MA 309
38 = OUTDOOR UNIT
MA =MODEL
OUTDOOR UNIT
BQ-
--
VOLTAGE 3 = 208/230- 1 - 60
NOT USED
INDOOR FAN COIL TYPE
C =CASSETTE
VOLTAGE 3 = 208/230- 1 - 60
SYSTEM TYPE Q =HEATPUMP
MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT B=1:1
NOMINAL CAPACITY 09 -3/4TON 12 -1TON 18 -1-1/2TONS
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org.
NOT USED
UNIT TYPE
- = OUTDOOR UNIT
3
STANDARD FEATURES AND ACCESSORIES
Ease Of Installation
Mounting Brackets S Low Voltage Controls S
Comfort Features
Microprocessor Controls S Wired Remote Control A Wireless Remote Control S Automatic Horizontal Air Sweep S Air Direction Control S Auto Restart Function S Cold Blow Protection On Heat Pumps S Freeze Protection Mode On Heat Pumps S Turbo Mo d e S Silence Mode S Auto C h angeover On Heat Pumps S Follow Me S
Energy Saving Features
Sleep Mode S Stop/Start Timer S 46° F Heating Mode (Heating Setback) S
Safety And Reliability
3MinuteTimeDelayForCompressor S Over Current Protection For Compressor S Indoor Coil Freeze Protection S Indoor Coil High Temp Protection in Heating Mode S Condenser High Temp Protection in Cooling Mode S
Ease Of Service And Maintenance
Cleanable Filters S Diagnostics S Liquid Line Pressure Taps S
Application Flexibility
Condensate Pumps S Crankcase Heater S
Legend
SStandard A Accessory
INDOOR UNIT ACCESSORIES
Grille
To maximize shipping efficiency, the grille for the in- ceiling cassette is set up as an accessory.
NOTE: Grille is required.
OUTDOOR UNITS
Crankcase Heater
Standard on all unit sizes. Heater clamps around compressor oil stump.
4
DIMENSIONS - INDOOR
Fig. 1 – Indoor unit
Unit size
Height in(mm) 10.24(260) 1.97 (50) 10.24 (260) 1.97 (50) 10.24 (260) 1.97 (50)
Width in(mm) 22.44(570) 25.47 (647) 22.44 (570) 25.47 (647) 22.44 (570) 25.47 (647) Depth in(mm) 22.44 (570) 25.47 (647) 22.44 (570) 25.47 (647) 22.44 (570) 25.47 (647)
Height in(mm) 11.42 (290) 4.84 (123) 11.42 (290) 4.84 (123) 11.42 (290) 4.84 (123)
Width in(mm) 25.79 (655) 28.15 (715) 25.79 (655) 28.15 (715) 25.79 (655) 28.15 (715) Depth in(mm) 25.79 (655) 28.15 (715) 25.79 (655) 28.15 (715) 25.79 (655) 28.15 (715)
Weight-Gross lbs(kg) 41.88 (19) 9.92 (4.5) 41.88 (19) 9.92 (4.5) 46.3 (21) 9.92 (4.5)
Weight-Net lbs(kg) 35.27 (16) 5.51 (2.5) 35.27 (16) 5.51 (2.5) 39.68 (18) 5.51 (2.5)
body panel body panel body panel
9K 12K 18K
Dimensions
Packing
5
DIMENSIONS - OUTDOOR
Model W in (mm) D in (mm) H in (mm) L1 in (mm) L2 in (mm)
9K/12K 32.0 (810) 12.2 (310) 22.0 (558) 20.9 (530) 11.4 (290) 82.5 (37.4)
18K 32.3 (845) 12.6 (320) 27.6 (700) 22.1 (560) 13.2 (335) 102.5 (46.5)
Fig. 2 – Outdoor unit
Operating
Weight lb (kg)
6
Loading...