40MAQ
High Wall Ductless System
Sizes 09 to 36
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 40MAQ series ductless split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection
of fan coils permits creative solutions to design problems such as:
S Add−ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork
S Historical renovations or any application where
preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer.
The indoor units are whisper quiet. There are no compressors
indoors, either in the conditioned space or directly over it, and
there is none of the noise usually generated by air being forced
through ductwork.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only
by refrigerant piping and wiring to prevent intruders from crawling
through ductwork. In addition, since the outdoor units can be
installed close to an outside wall, coils are protected from vandals
and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. A mounting
bracket is standard with the indoor units and only wire and piping
need to be run between the indoor and outdoor units. These units
are fast and easy to install ensuring minimal disruption to
customers in the home or workplace. This makes the 40MAQ
ductless systems the equipment of choice, especially in retrofit
situations.
BUILT−IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide
years of trouble−free operation.
The high wall indoor units include protection against freeze−up
and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three
minute time delay before the compressor starts the over−current
protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be
controlled individually based on usage pattern. The air sweep
feature provided permits optimal room air mixing to eliminate hot
and cold spots for occupant comfort. In addition, year−round
comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or
cooling when required. There is no need to run large supply−air
fans or chilled water pumps to handle a few spaces with unique
load patterns. In addition, because air is moved only in the space
required, no energy is wasted while air moves through the ducts.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate
access to the control compartment, providing a service technician
access to check unit operation. In addition, the draw−thru design of
the outdoor section means that dirt accumulates on the outside
surface of the coil. Coils can be cleaned quickly from the inside
using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced
due to easy−to−use cleanable filters. In addition, these high wall
systems have extensive self−diagnostics to assist in
troubleshooting.
EASY−TO−USE CONTROLS
The high wall units have microprocessor−based controls to provide
the ultimate in comfort and efficiency. The user friendly wireless
remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is
easily accomplished.
Adding a condensate pump accessory to the high wall fan coil
provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating &
Refrigeration Institute), and ETL.
2
MODEL NUMBER NOMENCLATURE
INDOOR UNIT
BQB
40= FAN COIL UNIT
MA = MODEL
SYSTEM TYPE
Q = HEAT PUMP
40 MA 309
- -
VOLTAGE
1 =115-1-60
3 = 208/230-1-60
B = ALL MODELS
NOMINAL CAPACITY
09 - 3/4 TON
12 - 1 TON
18 - 1-1/2 TONS
24 - 2 TONS
30 - 2 -1/2 TONS
36 - 3 TONS
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
NOT USED
INDOOR FAN COIL TYPE
B = HIGH WALL
3
STANDARD FEATURES AND ACCESSORIES
Ease Of Installation
Mounting Brackets S
Low Voltage Controls S
Comfort Features
Microprocessor Controls S
Wired Remote Control A
Wireless Remote Control S
Automatic Vertical Air Swing S
Air Direction Control S
Auto Restart Function S
Cold Blow Protection On Heat Pumps S
Freeze Protection Mode On Heat Pumps S
Turbo Mode S
Silence Mode S
Auto Changeover On Heat Pumps S
Follow Me S
Energy Saving Features
Sleep Mode S
Stop/Start Timer S
46°F Heating Mode (Heating Setback)
Safety And Reliability
Indoor Coil Freeze Protection S
Indoor Coil High Temp Protection in Heating Mode S
Ease Of Service And Maintenance
Cleanable Filters S
Diagnostics S
Application Flexibility
Condensate Pumps A
Legend
S Standard
A Accessory
S
INDOOR UNITS
On high wall fan coils, the condensate pump has a lift capability
of 12 ft. (3.6 m) on the discharge side with the pump mounted in
the fan coil or 6 ft. (1.8 m) on the suction side if the pump is
remote mounted. The pump is recommended when an adequate
drain line pitch cannot be provided, or when the condensate must
move up to exit.
NOTE: An external 115v power source is required to run the
pump on unit sizes 9k and 12k.
Fig. 1 – Condensate Pump Accessory
ACCESSORIES
ACCESSORY NO. DESCRIPTION FOR MODELS
53DS-900---117
53DS-900---118
KSACN0101AAA
53DS-900---089
53DS-900---008
CONDENSATE PUMP
(115V)
CONDENSATE PUMP
(208-230V)
WIRED REMOTE
CONTROL
INSULATED 25’ LINE
SET - 1/4” X 3/8”
INSULATED 25’ LINE
SET - 1/4“ X 1/2”
SIZES 09, 12 (115V)
SIZES 09, 12, 18, 24,
30 (208-230V)
ALL SIZES
SIZE 09
SIZES 12, 18
4
DIMENSIONS − INDOOR
Fig. 2 – Indoor Unit
HIGH WALL UNIT SIZE 9K 12K 9K 12K 18K 24K 30K 36K
Voltage (115V) (115V) (208/230V) (208/230V) (208/230V) (20/230V) (208/230V) (20/230V)
Height In (mm) 11.02 (280) 11.02 (280) 11.02 (280) 11.02 (280) 12.40 (315) 13.39 (343) 13.39 (343) 13.39 (343)
Width In (mm) 32.87 (835) 32.87 (835) 32.87 (835) 32.87 (835) 38.98 (990) 46.69 (1186) 46.69 (1186) 46.69 (1186)
Depth In (mm) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 8.58 (218) 10.16 (258) 10.16 (258) 10.16 (258)
Weight-Net Lbs (kg) 19.18 (8.7) 19.18 (8.7) 19.18 (8.7) 19.18 (8.7) 24.46 (12.0) 40.12 (18.2) 40.12 (18.2) 40.12 (18.2)
CLEARANCES − INDOOR
CEILING
A150693
5
"
(0.13m)
min.
6" (0.15m) min.
(1.8m)
6'
FLOOR
Fig. 3 – Indoor Unit Clearance
5
"
(0.13m)
min.
5