Carlo Gavazzi UA 30 CLD Data Sheet

Specifications are subject to change without notice (26.10.01) 1
Ultrasonic Diffuse, Analogue Output with Teach-in
Types UA 30 CLD .. .. M1 TI
• Cylindrical M30 polyester housing
• Sensing distance: 100-1500 mm, 200-2000 mm or 300-3500 mm
• Teach-in functionality
• Power supply: 19 to 30 VDC
• 8° beam angle
• Protection: Short-circuit, reverse polarity, transients
• Protection degree IP 67
• M12 plug, 5 pin
Product Description
Ultrasonic sensor Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection Teach-in
Type Selection
Housing Connection Rated operating Analogue output and Ordering no. diameter dist. (S
n
) 2 PNP outputs NO/NC Teach-in
M30 Plug M12 100-1500 mm 0-10 VDC and 2 x PNP UA 30 CLD 15 AK M1 TI M30 Plug M12 200-2000 mm 0-10 VDC and 2 x PNP UA 30 CLD 20 AK M1 TI M30 Plug M12 200-2000 mm 4-20 mA and 2 x PNP UA 30 CLD 20 AG M1 TI M30 Plug M12 200-2000 mm 2 x PNP UA 30 CLD 20 PO M1 TI M30 Plug M12 300-3500 mm 0-10 VDC and 2 x PNP UA 30 CLD 35 AK M1 TI
Ordering Key
UA 30 CLD 35 AK M1 TI
A family of diffuse ultrasonic sensors with sensing range from 100-1500 mm, 200-2000 mm and 300-3500 mm with teach-in adjustment. Adjust­ments by teach-in make it possible to set the analog angle according to the re­quests and program the out­put to NO or NC switching as well. The outputs are either 0­10 V or 4-20 mA which make
it an ideal choice for distance measurement, level measure­ment, diameter measurement or slope control with cus­tomised settings. Due to use of microprocessor control the digital filtering makes the sen­sor very immune against most electromagnetic interferences and enables synchronisation in an easy way.
Specifications
Rated operational volt. (Ue) 19 to 30 VDC
(ripple included)
Ripple 10%
Output current (I
e
) max. 100 mA (continuous)
for switching outputs
No-load supply current (I
o
) 45 mA
Protection Short-circuit, transients and
reverse polarity
Rated insulation voltage > 1 kV Output
UA30CLD..AKM1TI Analogue 0-10 VDC,
2 PNP open collector outputs, NO or NC
UA30CLD20AGM1TI Analogue 4-20 mA,
2 PNP open collector outputs, NO or NC
UA30CLD20POM1TI 2 PNP open collector
outputs, NO or NC
Teach-in Set point adjustment
NO/NC selection
Indication Set points, 2 LED’s Rated operating distance
UA30CLD15 .. M1 TI 100-1500 mm UA30CLD20 .. M1 TI 200-2000 mm UA30CLD35 .. M1 TI 300-3500 mm
Operating frequency 1 Hz Response times
UA30CLD15/20 .. M1 TI 60 ms (target speed 1 m/s)
300 ms (step response)
UA30CLD35 AG M1 TI 120 ms (target speed 1 m/s)
500 ms (step response)
Hysteresis (H)
(differential travel) Programmable
Temperature compensation Yes Beam angle
2 Specifications are subject to change without notice (26.10.01)
Dimensions
UA 30 CLD .. .. M1 TI
Installation Hints
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided
Specifications (cont.)
Ambient temperature
Operating
-15° to +70°C (5° to +158°F)
Storage
-25° to +85°C (-13° to +185°F)
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13) Housing material
Polyester PBTP
Connection
Plug M12, 5-pin
Weight 148 g Tightening torque 7.5 Nm CE-marking Yes
150 mm
1500 mm
300 mm
300 mm
250 mm
2000 mm
350 mm
3500 mm
UA 30 ... 15 UA 30 ... 20 UA 30 ... 35
Detection Range
Wiring
Pin Function
1 24 VDC 2 SP 2 3 0 V GND 4 SP 1 5 0 ... 10 V
Guaranteed detection of a target 100 x 100 mm
Possible detection of a large target
Loading...