Carelink CL-MC-XE1-IP-Y User Manual

® 2013, All right of the brand and product names are reserved by Carelink Ltd.
CL-MC-XE1-IP-Y Multiplexer
Solution
Multi-Service over 100Mbase-Tx
User Manual
Release 1.05
Doc No.: EX05-MN-001-MDN
http://carelink.com.hk
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
I
Copyright
No part of this manual may be reproduced in any form or by any means or used to make any derivative,
such as translation, adaptation, or transformation, without the consent of the manufacture.
Trademarks
As to Windows 98, Windows NT, Windows 2000, Windows Vista, Windows XP and Windows 7, those
are registered trademarks of their respective companies.
Caution
Circuit/electrical equipment is sensitive to the impact of static electricity, which can endanger their
delicate electronics. Dry weather conditions or walking across a carpeted floor may cause you to
acquire a static electrical charge.
To protect your equipment, please pay attention to the following:
Touch the metal chassis of your computer to ground the static electrical charge before you pick up
the circuit equipment.
Pick up the device by holding it on the left and right edges only.
Put on the strap of static-electricity-proof to avoid impacting the function during the equipment is
operating.
Accessories Per Package
Please check the following accessories before installation
CL-MC-XE1-IP-Y x 1 set (Please verify the part number)
(Optional) “x 1 piece AC Power Cord” or “Power Adapter (+5VDC 110/220 VAC)”
 (Optional) A pair of L-shaped brackets and mounted screws
A copy of electrical file of user manual for buyer
Contact Information
Customer Service
System
Carelink Ltd.
Web http://www.carelink.com.hk
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- II -
Abbreviation
AIS Alarm Indication Signal
ANSI American National Standards Institute
AP Access Point
CESoPSN Circuit Emulation Service over Packet Switch Network
CLI Command Line Interface
FE Fast Ethernet
ITU International Telecommunication Union
LED Light Emitting Diode
LOS Loss of Signal Alarm
LOF Loss of Frame Alarm
MAC Media Access Control
OOF Out of Frame
L-bit Remote Defect Indication
RDI Remote Detect Indicator
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 1 -
Table of Contents
Chapter 1 Introduction ...........................................................................................................2
1-1 Functional Description ................................................................................................................ 2
1-2 Features ..................................................................................................................................... 2
1-3 CL-MC-XE1-IP-Y Outlook .......................................................................................................... 3
1-4 Applications of CL-MC-XE1-IP-Y ............................................................................................... 3
1-5 Technical Specifications ............................................................................................................. 3
1-6 Order Information ....................................................................................................................... 4
Chapter 2 Installation Notes ..................................................................................................5
2-1 Description.................................................................................................................................. 5
2-2 Unpacking................................................................................................................................... 5
2-3 Site Requirements ...................................................................................................................... 5
2-4 Site Selection ............................................................................................................................. 5
2-5 AC or DC Electrical Outlet Connection ...................................................................................... 6
2-6 Rack Installation Configuration .................................................................................................. 6
2-7 Getting Start ............................................................................................................................... 7
Chapter 3 Operating Instructions ..........................................................................................8
3-1 Description.................................................................................................................................. 8
3-2 Front Panel ................................................................................................................................. 8
3-3 Rear Panel................................................................................................................................ 10
3-4 Loopback Mode ........................................................................................................................ 11
3-5 IP Configuration ........................................................................................................................ 11
3-6 Interface Configuration ............................................................................................................. 11
3-7 Fault Report .............................................................................................................................. 11
3-8 Save Configuration ................................................................................................................... 12
3-9 Command Line Interface for Setup .......................................................................................... 13
Appendix ...............................................................................................................................17
A) Script for resetting CL-MC-XE1-IP-Y to default I .......................................................................... 17
B) Script for resetting CL-MC-XE1-IP-Y to default II ......................................................................... 18
C) Script for resetting CL-MC-XE1-IP-Y to default III ........................................................................ 19
D) Script for resetting CL-MC-XE1-IP-Y to default IV ....................................................................... 21
E) Script for resetting CL-MC-XE1-IP-Y to default V ........................................................................ 23
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 2 -
Chapter 1 Introduction
1-1 Functional Description
The CL-MC-XE1-IP-Y series is a “Multi-service (TDM and Ethernet) over Ethernet” bridge, which
transports upto four ports of E1 and one LAN into Ethernet packets. Its target application shown in Figure
1-4.1 is the transparent E1 port interconnection via the IP networks (using Ethernet packets).
CL-MC-XE1-IP-Y series implements the newest Circuit Emulation System over IP technology.
The E1 over IP of CL-MC-XE1-IP-Y is compliant with IETF “CES over IP” standard. Versatile LEDs are
provided for alarms and status indication.
1-2 Features
Support 1~4 E1 over 100M Ethernet (WAN).
Provide 1-port Ethernet LAN for Ethernet access.
User side as standard TDM (E1) interfaces.
Full-duplex 100Mbps Ethernet Interfrace.
Provides auto-negotiation which can auto configure CL-MC-XE1-IP-Y to 100M depending on the
speed of Ethernet port.
Support “E1” clock source with alternative “E1 line recovered clock”, “adaptive clock” and “internal
clock”.
Provide ”ACT” and “ALM” LED indicators for each TDM interface.
Provide “Link/Activity” and “Link Speed” LED indicators for Ethernet interface.
Stand–alone desktop unit, optional 19” rack mountable.
Power Support (i) Built-in “AC 110/220 VAC input” or “DC -36 ~ -72VDC input”
(ii) (optional) +5VDC power jack .
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 3 -
1-3 CL-MC-XE1-IP-Y Outlook
Figure 1-3.1 CL-MC-XE1-IP-Y 4-Port E1 Outlook
1-4 Applications of CL-MC-XE1-IP-Y
The CL-MC-XE1-IP-Y is mainly applied for the solution of wireline usage connected with PSTN via E1
and Router via 100BaseTx and for integrating the various equipment based traditional TDM and popular
IP services.
Figure 1-4.1 Application Configuration of CL-MC-XE1-IP-Y Multiplexer
1-5 Technical Specifications
(1) Construction
Physical Dimension
Height: 44 mm (1U)
Width: 320 mm
Depth: 125 mm
Weight: 1.2 Kg ~ 1.3kg (depending on which model is purchased)
(2) 100M Ethernet Interface
a. Compliant with 802.3/802.3u standards
b. 100-BaseT with RJ45 connector
c. Full-duplex
d. Support Auto-negotiation
e. LED indicator for Ethernet: Link status and Act activity
(3) TDM Interfaces : E1 Interface
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 4 -
a. Data Rate: 2.048 Mbit/s 50 ppm
b. Line Code: Bipolar with HDB3
c. Test Load Impedance: 120 ohms± 5% resistive, balanced.
d. LED indications for E1: ACT, ALM
e. Connector Type: RJ48c
(4) Power Supply
a. AC: 85~264V, 47~63Hz or
(Optional) DC: -36 ~ -72 V
b. (Optional) +5VDC Power Jack : external power adapter with +5VDC 110/220 VAC
c. Maximum Power Consumption: < 15 watts
(5) Operating Environment
a. Ambient temperature: 0 ~ 40 ℃ for indoor application
(Optional): 0 ~ 55
b. Storage temperature: 0 ~ 85
c. Relative humidity: 5 ~ 95 non condensing
1-6 Order Information
Feature Options:
[ Downlink Interface ] 1x E1 2x E1 4x E1
[ Management ] Craft terminal Craft terminal + SNMP-based MIB management
[ Power ] 1x AC 1x DC +5VDC power jack input port 1x AC + 1x DC
+5VDC power jack input port + 1x AC +5VDC power jack input port + 1x DC
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 5 -
Chapter 2 Installation Notes
2-1 Description
This chapter provides the information needed to install CL-MC-XE1-IP-Y series. It is important to follow
the installation instructions to ensure normal operation of the system and to prevent damages from
human negligence.
2-2 Unpacking
If there is a possibility for future relocation of the CL-MC-XE1-IP-Y unit, please keep the packing cartons
and protection packaging material.
Please carefully unpack and inspect the unit and accessories for potentially damaged and missing parts.
Contact our nearest sales representative or our company directly if you detect any damaged or missing
parts. Improper handling during shipment may cause early failure.
2-3 Site Requirements
Users should follow the precautions below to insure the safety and to minimize the risk of damage to the
equipment:
Make sure that the power outlet is properly grounded. Please refer to article 250 of the National Electrical
Code (NEC) Handbook. Proper grounding should include a minimum of:
A grounded rod buried outside the building at least 8 feet (2.44 meters) deep.
2-4 Site Selection
For best performance, the distance of 6 feet (1.83 meters) from the AC power outlet to CL-MC-XE1-IP-Y
series is preferred. To allow easy access to the equipment, leave at least 36 inches (90 cm) clearance in
the front and at least 4 inches (10.2 cm) at the rear.
Caution
:
To avoid overheating, leave at least 1 inch (2.5 cm) on either side of the CL-MC-XE1-IP-Y
series. Also, DO NOT stack other equipments on top of the CL-MC-XE1-IP-Y unit in order to
ventilate the system normally.
www.carelink.com
CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 6 -
2-5 AC or DC Electrical Outlet Connection
For safety and to prevent damage to CL-MC-XE1-IP-Y series, make sure that the power requirement
matches the appearance of user electric outlets. Connect power source to CL-MC-XE1-IP-Y unit and
power on the equipment.
Caution:
Damage to compact key components may occur if the output voltage applied to device
is not within the specified range.
2-6 Rack Installation Configuration
There are 3 kinds of common parts for each CL-MC-XE1-IP-Y pack, including 1 set of TDM over IP
multiplexer, 1 piece of AC power cable. If CL-MC-XE1-IP-Y intends to be mounted into a rack, a pair of
L-shaped brackets with 10 pieces of screws should be requested by user’s order. The following Figure
2-6.1 as desktop mode and Figure 2-6.2 as rack mode, and the procedures are to show the installation
configuration.
Figure 2-6.1 CL-MC-XE1-IP-Y series as desktop mode
Figure 2-6.2 CL-MC-XE1-IP-Y series as rack mount mode
www.carelink.com
Loading...
+ 18 hidden pages