Thank you for purchasing our Detecto Model VET330 Digital Veterinary Scale. The VET330 is equipped with a rechargeable battery pack that (after 14 hours of charging) is able to provide approximate 8 hours of continuous use.
This manual will guide you through setup and operation of your scale. Please read it thoroughly before attempting to operate this scale and keep it handy for future reference.
ЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬ
FCC COMPLIANCE STATEMENT
WARNING! This equipment generates uses and
can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference.
You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402, stock No. 001-000-00315-4.
ЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬЬ
All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk.
Serial Number_______________________ Date of Purchase ____________________ Purchased Form_____________________
___________________________________ ___________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
Introduction ………………………………….. 1
Specifications.………….………….………… 1
Installation………………………………….… 2
Display Functions ……..……..…..…………. 3
Key Functions …………...………………….. 4
Operation ……………………………………. 5
Configuration ………………..………………. 6
Gravity Compensation……………………… 7
Display Message …….…..………..……….. 8
Care and Maintenance….…..…………..….. 8
SPECIFICATIONS
Weight Display: LCD, 7 Digit, with decimal 1.0”
Characters
Dimensions of Display head:
Platform Size: 36" W x 22" D x 1.97”H
Zero: Established on power up
Power: Built-in rechargeable battery
Tare: 100% of full scale capacity
Temperature: 40 to 105°F (5°to 35°C)
Humidity: 25% ~95% RH
Capacity and Division:
Keys:
Features: Low battery indicator, Power
Weight: 52 Lbs (23.5 kg)
PRECAUTIONS
Before using this instrument, read this manual and pay special attention to all "WARNING" symbols:
IMPORTANT ELECTRICAL
10.63" W x 3.54" D x 1.77" H (270 mm x 90 mm x 45 mm)
(900 mm x 550 mm x 50 mm)
routine and maintained by auto-zero circuitry.
pack (7.2VDC/1200mA) or 120 VAC 60Hz powering a 15 VDC 300 mA wall plug-in UL/CUL listed power supply
330lb x 0.2lb, 150kg x 100g
HOLD, UNIT, ON/ZERO/OFF, TARE
saving selectable timing auto shut-off
WARNING
1
INSTALLATION
UNPACKING
Before beginning installation of your scale, make certain the instrument has been received in good condition. When removing the scale from its packing, inspect it for signs of damage, such as exterior dents and scratches. Keep the carton and packing material for return shipment if it should become necessary. It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit.
1. Remove the scale from the shipping carton and inspect it for any signs of damage.
2. Plug-in the 15VDC adapter to use the scale and to begin charging the battery pack. Refer to the POWER SUPPLY or BATTERY PACK sections of this manual for more instruction.
3. Place the scale on a flat level surface.
4. The scale is now ready for use.
POWER SUPPLY
To apply power to the scale using the supplied 15VDC, 300 mA power supply, insert the plug from the power supply cable into the power jack on the right side of the indicator and then plug power supply into the proper electrical outlet. The scale is now ready for operation.
BATTERY PACK
The scale uses a 7.2VDC, 1200 mA built-in rechargeable battery pack. The VET330 can operate for approximate 8 hours of continuous use with a fully charged battery pack.
BATTERY CHARGING
To recharge the battery pack, the power supply must be connected to an AC power outlet and plugged into the scale. It will take approximately 14 hours to fully recharge the battery pack in the scale. While the batteries are charging the VET330 can still be operated. Note that charging the battery pack for more than 14 hours will not damage it.
If the power supply is disconnected before the 14 hours, the scale will continue to charge the battery pack when the power supply is plugged back in.
LOW BATTERY
When the battery pack is near the point it needs to be recharged, a low battery indicator on the display will turn on. If the battery voltage drops too low for accurate weighing, the scale will automatically shut off and you will be unable to turn it back on. When the low battery indicator is displayed, the operator should plug the power supply into the scale and then into the proper electrical wall outlet. The scale will begin charging the battery pack.
2