Cardinal Detecto PZ3000 Series, Detecto PZ3015, Detecto PZ3015L, Detecto PZ3030, Detecto PZ3060 Owner's Manual

(
PZ3000 Series
CARDINAL SCALE MFG. CO. 8528-M372-O1 Rev E 05/14
PO BOX 151
417) 673-4631 FAX (417) 673-5001
PH
www.detectoscale.com
WEBB CITY, MO 64870
Ingredient Scale
Owner’s Manual
Printed in USA
Technical Support: Ph: 866-254-8261  techsupport@cardet.com
A
INTRODUCTION
We wish to thank you for your purchase of our PZ3000 Ingredient scale. It has been designed and manufactured at our factory in Webb City, MO U.S.A. with quality and reliability.
This manual will instruct you in the proper installation, operation and maintenance of your new scale. Please read it before attempting to use the scale and keep it handy for future reference.
FCC Compliance Statement
This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference.
You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402, stock No. 001-000-00315-4.
All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk.
TABLE OF CONTENTS
SPECIFICA TIONS . . . . . . . . . . . . . . . . . . . .. . .
INST ALLA TION . . . . . . . . . . . . . . . . . . . . . . . . .
POWER CONNECTION . . . . . . . . . . . . . . . . . . 4
Power Supply . . . . . . . . . . . . . . . . . . . . .. . . .
Battery Operation . . . . . . . . . . . . . . . . . .. . .
Battery Charging . . . . . . . . . . . . . . . . . . . . ..
Battery Installation/Replacement . . . . . . . . 4
Extended Battery Operation . . . . . . . . . . . .
OPTIONAL ZERO DEVICES . . . . . . . . . . . . . .
KEYP AD DESCRIPTION . . . . . . . . . . . . . . . . .
NNUNCIA TORS . . . . . . . . . . . . . . . . . . . . . . . 9
OPERA TION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARE AND MAINTENANCE . . . . . . . . . . . . . .
SETUP AND Calibration . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . .
P ARTS IDENTIFICATION . . . . . . . . . . . . . . . .14
Weight Display
Dimensions Display Scale Base PZ3015
PZ3015L PZ3030 PZ3060
Zero
Power Requirements
Tare
Operation Temperature
Humidity Capacity
Certifications
SPECIFICATIONS
6 Digit, 0.7" LCD Digital Display
7.5" W x 1.5" D x 4.5" H 8" W x 8" D x 1.75" H
12" W x 12" D x 1.75" H 12" W x 12" D x 1.75" H 14" W x 12" D x 3" H
Established on power up routine and maintained by auto-zero circuitry.
100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA listed AC power adapter (Cardinal part number 6800-1045) OR optional 6 “AA” NiMH batteries (1.2v/2700 mAh). NOTE: On PZ3060, the
batteries (Cardinal part number 6800-0020) ARE included.
ZERO key on keypad, Lite Way Sensor or optional Foot Switch or Piezo Button
30 to 110 °F (-1 to 43 °C)
75% without condensation 15lb x 0.005
30lb x 0.01 60lb x 0.02
NOT LEGAL FOR TRADE
1 3
4 4 4
6 7 8
10 10 11 13
8528-M372-O1 Rev E PZ3000 Series
1
2
Serial Number_______________________ Date of Purchase ____________________ Purchased Form_____________________
___________________________________ ___________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
PRECAUTIONS
Before using this instrument, read this manual and pay special attention to all "NOTIFICATION" symbols:
IMPORTANT ELECTRICAL
WARNING
8528-M372-O1 Rev E PZ3000 Series
INSTALLATION
1. Carefully remove the scale base and display from the shipping carton and inspect them for
any evidence of damage (such as exterior dents and scratches) that may have taken place during shipment. Remove the packing material from the scale base and on the PZ3030, the shipping screw on the bottom of the scale base. Next, remove the protective covering from the display and keypad. Keep the carton, packing material and shipping screw (on the PZ3030) for return shipment if it should become necessary . NOTE: It is the r espon sibility of the purchaser to file all claims for any damages or loss incurred during transit.
2. To mount the display on the scale base, locate the two mounting screws on the display and the two slotted holes in the scale base bracket.
3. Lift the scale (by the bracket) high enough to allow you to align the two screws on the display with the large end of the two slotted holes in the bracket. Place the screws on the display in the bracket and gently pull forward to secure the display to the bracket.
4. Plug the AC power supply into the power jack, located on the bottom side of the display (refer to Figure 1) and then connect the AC power adapter into the proper electrical outlet.
5. If it is desired to use the scale remotely (no AC power), with the exception of the PZ3060, you must first obtain and install 6 NiMH batteries (2300mAh minimum). The batteries should then be allowed to charge approximately 8 hours. Charging the batteries for more than 8 hours will not harm them. The scale may be operated while the batteries are charging.
6. Place the scale on a stable, vibration-free, level surface away from direct sunlight and any rapidly moving air source (heating and cooling vents).
7. Place commodity tray on the scale. The scale is now ready to use.
CAUTION! DO NOT place the scale on any unstable cart, stand or table. The scale may fall causing injury to the operator, and seriously damage the unit, or proper operation of the scale may be inhibited.
Display Mounting Screws
Figure No. 1
8528-M372-O1 Rev E PZ3000 Series
Optional Zero Device Connector
Power Supply Jack
Scale Base Cable
3
POWER CONNECTION
NOTE: The PZ3000 can be operated from a power supply or from 6 “AA” size,
(2300mAh minimum) NiMH batteries. The power supply is also used to recharge the NiMH batteries. Batteries are available by ordering Cardinal part number, 6800-0020.
Power Supply
To power the PZ3000 using the power supply, connect the power supply's connector into the power jack on the bottom side of the display and then connect the 12 VDC, 1 Amp power adapter into the proper electrical outlet. See Figure 1. On models requiring 220 VAC, it is the customer’s responsibility to obtain the correct power adapter plug. The scale is now ready for operation.
Battery Operation
Battery operation is a standard feature of the PZ3000 Series Ingredient Scale, although the batteries are optional (not included, except on model PZ3060). The scale will operate for up to 50 hours on fully charged batteries depending on the condition of the batteries (from new to about 500 recharges). The battery bar graph indicates the battery capacity in 4 steps:
4 segments - the full battery capacity is available, 3 segments - the battery is at 75% of capacity, 2 segments - the battery is at 50% of capacity, 1 segment: - the battery is at 25% capacity.
When the battery voltage drops too low for accurate weighing, the display will show LoBAt an d then shut off. You will be unable to turn the display back on until the AC power supply is connected to the display to operate it and recharge the batteries.
Battery Charging
To recharge the NiMH batteries, the AC power supply must be connected to a power outlet and plugged into the display. It will take approximately 4 to 8 hours to fully recharge the batteries in the display. Charging the batteries for more than 8 hours will not damage them . NOTE: The scale may be operated while the batteries are charging.
Battery Installation/Replacement
To install or remove the batteries, the following steps should be followed:
1. Remove the indicator from the scale,
wall or table stand.
2. Turn the indicator so that the display
is facing away from you and place it face down on a table or bench.
3. Referring to Figure No.2, locate the
two screws on the angled edge of indicator. NOTE: The PZ3015 and PZ3030 use two thumbscrews and the PZ3060 uses two socket head cap screws instead of thumbscrews.
4. Remove the screws and washers
under them.
5. Lift the battery door exposing the
battery holder.
6. Referring to Figure No. 3, locate and
remove the connector on the end of the battery holder.
Remove these Screws
Figure No. 2
4
8528-M372-O1 Rev E PZ3000 Series
POWER CONNECTION, CONT.
7. Slide one side of the battery door so that it clears the edge of the indicator enclosure and
then remove the battery door.
8. Place the battery door on a table or bench with the battery holder and battery strap up.
9. Referring to Figure No. 3, remove the 2 Philips screws securing the battery strap to the
battery door and remove the strap.
Battery Strap
Figure No. 3
Remove Philips Screws
10. To install or replace the batteries, first remove the battery holder cover by pushing in on
the tab and lifting it up. Refer to Figure No. 4.
11. If replacing the batteries, remove all 6 batteries from the battery holder. If installing new
batteries, proceed to step 12. NOTE: To insure optimum performance of your PZ3000 when powered by the
internal battery, replace all 6 batteries with new “AA” size, NiMH batteries (2300mAh minimum). DO NOT mix new and used batteries.
Battery
Connector
Figure No. 4
Push in and lift here
12. Install the 6 new “AA” size batteries in the battery holder, noting the polarity markings
located in the battery holder. Refer to Figure No. 5.
13. After placing all 6 batteries in the holder, replace the battery cover and battery strap.
Secure the battery strap with the 2 Philips screws removed earlier.
14. Replace the battery door on the indicator and then re-connect the connector on the end of
the battery holder.
8528-M372-O1 Rev E PZ3000 Series
Battery
Cover
5
Figure No. 5
POWER CONNECTION, CONT.
+
-
-
+
6 “AA” Size NiMH Batteries
(2300mAh minimum)
15. Insuring no wires are between the battery door and the back of the indicator, lower the
battery door.
16. Install the two screws and washers removed in step 4. NOTE: The PZ3015 and PZ3030
use thumbscrews and should be finger-tightened only.
17. Return the indicator to the scale, wall or table stand.
18. Apply power to the PZ3000 using the power supply, to begin charging the new batteries.
19. The scale is now ready for operation.
+
-
-
+
+
-
-
+
Extended Battery Operation
In operations that require the remote use (no AC power) of the scale beyond the approximately 50 hours of continuous use, an auxiliary battery door assembly (CPN 8528-C365-0A) and 6 “AA” size, 2300 mAh minimum batteries (CPN 6800-0020) can be purchased to easily accommodate your operation.
The following steps describe how to remove the battery door and re-charge the batteries externally using the AC power adapter (battery charger).
1. Remove the indicator from the scale, wall or table stand.
2. Turn the indicator so that the display is facing away from you and place it face down on a
table or bench.
3. Referring to Figure No.2, locate the two screws on the angled edge of the indicator and
remove the screws and washers under them. NOTE: The PZ3015 and PZ3030 use two thumbscrews and the PZ3060 uses two socket head cap screws.
4. Referring to Figure No. 6 remove the connector from the end of the battery holder and
then remove the battery door and set it aside.
5. Place the auxiliary battery door with fully recharged batteries on the indicator and then
re-connect the connector to the end of the battery holder. See Figure No. 6.
6. Insuring no wires are between the battery door and the back of the indicator, lower the
battery door and install the two screws and washers removed in step 3. NOTE: The PZ3015 and PZ3030 use thumbscrews and should be finger-tightened only.
7. Return the indicator to the scale, wall or table stand. The scale is ready for operation.
8. Place the battery door removed in step 5 on a table or bench with the battery holder and
battery strap up.
6
8528-M372-O1 Rev E PZ3000 Series
POWER CONNECTION, CONT.
9. Referring to Figure No. 6, locate the battery charger jack on the battery door.
10. Plug the AC power adapter (battery charger) into the jack on the battery door and then
connect the AC power adapter (battery charger) into the proper electrical outlet.
11. Allow approximately 4 to 8 hours to fully recharge the batteries.
Figure No. 6
Battery Charger Jack
Battery
Connector
OPTIONAL ZERO DEVICES
In addition to the standard display pushbutton and “Lite Way” hands-free methods to zero the weight, the PZ3000 Series has an optional Foot Pedal or Mountable Pushbutton available. The model numbers for the optional zero devices are:
PZFS for the foot pedal and PZPB for the mountable pushbutton.
Figure No. 7
Power Supply Jack
Scale Base Cable
Optional Zero Device Plugs in Here