Cardinal Detecto 8435, Detecto 8435KG Owner's Manual

Page 1
DIGITAL
(
Pediatric Scale
Models 8435 & 8435KG
Owner’s Manual
CARDINAL SCALE MFG. CO. 8525-M316-O1 Rev A 02/10
www.detectoscale.com
Technical Support: Ph: 866-254-8261 x techsupport@cardet.com
PO BOX 151 x WEBB CITY, MO 64870
417) 673-4631 x FAX(417) 673-5001
PH
Printed in USA
Page 2
Page 3
DIGITAL PEDIATRIC SCALE
Thank you for your purchase of our Detecto Model 8435 (8435KG) Digital Pediatric scale. It has been manufactured with quality and reliability at our factory in Webb City, MO USA. Your scale has been tested before leaving our factory to insure accuracy and dependability for years to come.
This manual will guide you through assembly, installation, and operation of your scale. Please read it thoroughly before attempting to use your scale and keep it handy for future reference.
FCC COMPLIANCE STATEMENT WARNING! This equipment generates uses and can radiate radio frequency and if not
installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference.
You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4.
All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk.
SPECIFICATIONS
Capacity ….....…..…..… 130 lb x 0.1 lb (59 kg x 0.05 kg), selectable
Tray Size ...........…..….. 22” L x 14.75” W x 4.5” D (56 cm L x 37 cm W x 11 cm D)
Shipping Weight …....… 33 lb (15 kg)
Scale Height ....….…..... 37 1/2 ” (953 mm)
Display ….…….....…….. Six digit, Seven segment, 0.7 inch (17.8 mm) high LCD
Power .........………….... 6 “AA” size Alkaline, Ni-Cad or NiMH batteries (not included) OR an
optional 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA listed AC power adapter (Cardinal part number 6800-1045).
Keyboard .….....…......... Membrane type with 5 keys, On/Off, Lock/Release, Units, Zero,
BMI/Enter and 4 directional arrows
Serial Number_______________________
Date of Purchase ____________________
Purchased Form_____________________
___________________________________
___________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
Before using this instrument, read this manual and pay special attention to all "WARNING" symbols:
PRECAUTIONS
IMPORTANT ELECTRICAL
WARNING
8525-M316-O1 Rev A x 8435(KG)
1
Page 4
UNPACKING INSTRUCTIONS
-Err-
-OF-
-trL-
-UnS-
CALib AdErr ErrAL ErrAH
OCAP
OFF
x Remove scale from carton by lifting up with equal force from column and platform base.
x Remove all plastic wrapping, foam fillers and cardboard material from the scale.
x Place scale upside down on level, stable surface and remove all cardboard packing from
bottom of scale base.
x Return scale to upright position and check for any damage incurred in shipping. If scale
has been damaged, place a claim with the carrier. Use the original carton and shipping material to return the scale.
x Remove and unpack the AC power adapter, if the scale was ordered with this option.
BABY TRAY INSTALLATION
1. Referring to Figure No. 1, remove the 2 flat head screws from the scale platform.
2. Place the baby tray on the scale platform and align the holes in the tray with the holes in the scale platform.
3. Attach baby tray to scale platform using the 2 flat head screws remove in step 1.
Do not over-tighten the screws.
4. Scale is now ready for operation.
x DO NOT subject the platform to sudden shocks.
x DO NOT submerge indicator in water, pour or spray water directly on indicator.
x DO NOT use abrasive cleaners on this scale.
x DO NOT use acetone or other volatile solvents for cleaning.
x DO clean the scale and indicator using a damp soft cloth and mild detergent.
x DO avoid areas where the scale might be exposed to moisture.
Figure No. 1
CARE AND CLEANING OF SCALE
ERROR AND STATUS DISPLAYS
Display Meaning
General error, invalid keypad entry was attempted. Attempting to display a negative number greater than –9,999 or a
positive number greater than 99,999. Indicates an attempt to zero a weight outside scale zero range. Motion is present when indicator is attempting to perform one of the
following operations: Power Up Zero or Zero Weight Display. Indicates calibration is necessary.
Consult your scale service representative.
Scale weight exceeds scale capacity. Displayed to indicate indicator is turning off.
2
8525-M316-O1 Rev A x 8435(KG)
Page 5
OPERATION
[\
[\
DO NOT press the keys on the keypad with pointed objects (pencils, pens, etc). Damage to keypad resulting from this practice is NOT covered under warranty.
Basic Weighing
1. Place scale on a level, stable surface.
2. With the baby tray empty, press ON/OFF
key to turn on indicator.
3. Press ZERO key to zero weight display.
The ZERO and lb or kg annunciator will turn on to show that scale is ready to weigh baby.
4. Lay baby being weighed in the center of
baby tray. This will distribute the weight evenly across the scale platform.
5. Read weight display.
6. Remove baby from baby tray.
Zero Weight Display
1. If the indicator is not showing zero weight on the display, press ZERO key.
2. Weight display will return to zero. The
ZERO, STABLE annunciators will turn on to show a stable, center-of-zero weight condition.
and lb or kg
Figure No. 2
Zero Weight Display with Item on Scale
1. Place item (blanket or similar covering) on scale.
2. Weight display will show weight of item on scale.
3. Press ZERO key.
4. Weight display will return to zero. The ZERO, STABLE
turn on. The item’s weight has been "zeroed off".
5. Proceed with weighing operation.
and lb or kg annunciators will
Metric Conversion
Press UNITS key to toggle between pounds and kilograms. Note that lb or kg annunciator will turn on to show which weighing unit is active.
CAUTION!
Do not leave the baby unattended in the baby tray. Failure to maintain continual control of the baby can result in serious injuries should the baby fall from the baby tray.
8525-M316-O1 Rev A x 8435(KG)
3
Page 6
BATTERY OPERATION
niCAd
Batteries
The scale can use 6 "AA" size Alkaline, Ni-Cad or NiMH batteries (not included). You must first obtain and install batteries before operations can begin. Batteries are contained in a battery holder inside indicator. Access is via a removable panel on the back of indicator.
When using batteries, all 6 batteries must be of the same type. They must be all Alkaline, Ni-Cad or all NiMH. In addition, DO NOT mix Ni-Cad or NiMH batteries.
IMPORTANT! The scale can be operated from Alkaline, Ni-Cad or NiMH batteries. All six (6) batteries must be of the same type. They must all be Alkaline, all Ni-Cad or all NiMH. DO NOT mix Alkaline and Ni-Cad or NiMH batteries.
CAUTION! The AC power adapter is also used to recharge the batteries, when the scale is operated from Ni-Cad or NiMH batteries. DO NOT connect the AC power adapter to the scale if using Alkaline batteries. Also, when using Alkaline batteries, make sure or Setup Review sections of 750 Weight Indicator Owner’s Manual (8555-M260-O1).
Battery Installation/Replacement
To install or remove the batteries, the following steps should be followed:
1. Make sure the AC power adapter is
unplugged.
setup option is disabled (set to 0). Refer to Setup and Calibration
2. Remove the indicator from scale column
bracket. (Referring to Figure No. 3, pull the spring plunger down and slide the indicator up away from the bracket).
3. Turn the indicator over so that the display
is facing away from you.
4. Locate the rectangular panel on back of
indicator.
Battery Cover
5. To install or replace the batteries, first
remove the battery holder cover by pushing in on the tab and lifting it up. Refer to Figure No. 4.
Load Cell Cable
AC Power Adapter
Spring Plunger Release
Figure No. 3
Push in and lift here.
For more information on setup and operation of the indicator, see the 750 Owner’s Manual (8555-M260-O1).
4
Figure No. 4
8525-M316-O1 Rev A x 8435(KG)
Page 7
BATTERY OPERATION, CONT.
g
p
p
6. If installing new batteries, proceed to
step 7. If replacing the batteries, remove all 6 batteries from the battery holder and then proceed to step 7.
7. Install the 6 new “AA” size batteries in the battery holder, noting the polarity markings located in the battery holder. Refer to Figure No. 5.
8. After placing all 6 batteries in the holder, replace the battery cover.
9. Turn the indicator over (display facing up) and press the ON/OFF key.
10.If display turns on, batteries have been installed correctly. If not, remove panel and check for one or more improperly positioned batteries.
11.Return indicator to scale column bracket.
12.The scale is now ready for operation.
Indicator Installation
To install the indicator on the scale column bracket, place the screw heads on the back of the indicator into the large end of the slotted holes in the bracket. Pull down to secure the indicator. The spring plunger will lock the indicator to the bracket. See Figures No. 6, 7 and 8.
+ -
- +
+ -
- +
+ -
- +
Figure No. 5
Spring
er
Plun
Figure No. 7
Figure No. 6
AC Power
AC Power
ter
ter
Ada
Ada
Scale
Scale Cable
Cable
Figure No. 8
Spring Plunger Release
OPTIONAL AC POWER ADAPTER
To power the scale using the optional 12 VDC wall plug-in AC power adapter, connect the plug from the adapter into the power jack on the back of the indicator and then plug the power adapter into the proper electrical outlet. Refer to Figure 6. On models requiring 230 VAC, it is the customer’s responsibility to obtain the correct power adapter plug.
8525-M316-O1 Rev A x 8435(KG)
5
Page 8
PARTS IDENTIFICATION
FINAL ASSEMBLY
ITEM QTY PART NUMBER DESCRIPTION
1 1 33P1201X-1 BASE ASSEMBLY
2 1 430XG3R804 COLUMN WELDMENT
3 1 709G2R1204 LOAD CELL & MOUNTING ASSEMBLY
4 1 0033-B255-08 DRAFT ROD FOR (8435)
5 1 33P50 BABY TRAY
6 4 63K1038 BASE LEG
7 1 5930-B114-08 LABEL: SCALE MODEL NO. SHEET 7
8 1 0033-B439-0A MOUNTING BRKT
9 1 391RV204 NUT ELASTIC STOP 1/4-20 Z/P
10 1 6021-1454 SCW HEX HEAD 1/4 -20 X 3/4
11 1 6024-0004 WASHER FLAT 1/4
12 1 0033-B104-0A TOP PLATE ASSY.
13 1 593R986 SERIAL TAG
14 2 6024-0049 WASHER LOCK EXT #10
15 6 6024-0047 WASHER LOCK EXT 1/4
16 6 6021-1423 SCW TRUSS HEAD 1/4-20 X 1/2
17 2 6021-1045 SCW HEX HEAD #10-32 X 1/2 Z/P
18 1 750 DIG. WT. INDICATOR
19 2 6021-0868 SCW FLAT-HEAD. MACHINE-SCW 08-32X.500
* 1 6800-1045 OPTIONAL AC ADAPTER 100-240VAC/12VDC @ 1A
* NOT SHOWN
6
8525-M316-O1 Rev A x 8435(KG)
Page 9
PARTS IDENTIFICATION, CONT.
BASE ASSEMBLY
ITEM QTY PART NUMBER DESCRIPTION
1 1 33P1011X PLATFORM WELDMENT
2 4 3P2087 PLATFORM LOAD BEARING
3 1 3P1001X BASE WELDMENT
4 2 3P60 CHECK PLATE
5 2 6021-0985 HEX WASHER HD SCW #10 X 1/2
6 4 63K1038 BASE LEG
7 1 2U58 UNION CENTER HANGER
8 1 3P8003X SHORT LEVER ASSEMBLY
9 4 3P8059 UNION HANGER
10 1 3P122 BUMPER
11 1 3P8002X LONG LEVER ASSEMBLY
15 6 6024-0047 WASHER LOCK EXT 1/4
16 6 6021-1423 SCW TRUSS HEAD 1/4-20 X 1/2
8525-M316-O1 Rev A x 8435(KG)
7
Page 10
STATEMENT OF LIMITED WARRANTY
Detecto Scale warrants its equipment to be free from defects in material and workmanship as follows: Detecto warrants to the original purchaser only that it will repair or replace any part of equipment which is defective in material or workmanship for a period of one (1) year from date of shipment. Detecto shall be the sole judge of what constitutes a defect.
During the first ninety (90) days Detecto may choose to supply all necessary replacement parts and service during normal weekday working hours at no charge to the buyer.
After the first ninety (90) days Detecto will supply parts and service at the job site provided the owner agrees to pay the Dealer for all travel time, including mileage and test equipment, as well as any expenses incurred over the direct labor of the technician at the job site. This limited warranty honors only labor performed by Detecto authorized dealers.
This warranty does not apply to peripheral equipment not manufactured by Detecto; this equipment will be covered by certain manufacturer’s warranty only.
This warranty does not include replacement of expendable or consumable parts. This does not apply to any item which has deteriorated or damaged due to wear, accident, misuse, abuse, improper line voltage, overloading, theft, lightning, fire, water or acts of God, or due to extended storage or exposure while in purchaser’s possession. This warranty does not apply to maintenance service. Purchased parts will have a ninety (90) day repair or replacement warranty only.
Detecto may require components be returned to the factory; they must be properly packed and shipping charges prepaid. A return authorization number must be obtained for all returns and marked on the outside of all returned packages. Detecto accepts no responsibility for loss or damage in transit.
8
8525-M316-O1 Rev A x 8435(KG)
Page 11
STATEMENT OF LIMITED WARRANTY
Conditions Which Void Limited Warranty
This warranty shall not apply to equipment which: A.) Has been tampered with, defaced, mishandled or have had repairs
and modifications not authorized by Detecto. B.) Has had serial number altered, defaced, or removed. C.) Has not been grounded according to Detecto’s recommended
procedure.
Freight Carrier Damage
Claims for equipment damaged in transit must be referred to the freight carrier in accordance with freight carrier regulations.
This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of the product. Detecto will not be liable for consequential damages of any nature, including but not limited to, loss of profit, delays or expenses, whether based on tort or contract. Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured.
The foregoing is in lieu of all other warranties, express or implied including any warranty that extends beyond the description of the product including any warranty of merchantability or fitness for a particular purpose. This warranty covers only those Detecto products installed in the forty-eight (48) contiguous continental United States.
Ph. (800) 641-2008
E-mail: detecto@cardet.com
203 E. Daugherty
Webb City, MO 64870
D268-WARRANTY-DET
02/06
Printed in USA
8525-M316-O1 Rev A x 8435(KG)
9
Page 12
10
8525-M316-O1 Rev A x 8435(KG)
Loading...