Thank you for purchasing our Cardinal C Series Digital Count ing Sca le. Your sca le is
equipped with a rechargeable battery pa ck th at is able to provide 100 hours continuous
operation (with backlight on) or 200 hours continuous operation (with backlight off).
This manual will guide you through setup and operation of your scale. Please read it
thoroughly before attempting to operate this scale and keep it handy for future reference.
Copyright
All rights reserved. Reproduction or use, without expressed writte n permission, of editorial
or pictorial content, in any manner, is prohibite d. No pate nt lia bility is assumed with respect
to the use of the information containe d he r ein.
Disclaimer
While every precaution has been taken in the preparation of this manual, the Seller
assumes no responsibility for errors or omissions. Neither is any liability assumed for
damages resulting from use of the inform a tion contained herein. All instructions and
diagrams have been checked for accuracy and ease of applica tion; however, success and
safety in working with tools depend to a great ext ent u pon th e in dividu al accur a cy, skill and
caution. For this reason the Seller is not able to gu ar an tee the result of any procedure
contained herein. Nor can they assume responsibility for any damage to property or injury
to persons occasioned from the procedures. Pers on s engag ing th e pr o ced ures do so
entirely at their own risk.
FCC Compliance Statement
This equipment generates uses and can radiate radio frequency and if not ins ta lled and
used in accordance with the instruction manual, may c aus e interference to radio
communications. It has been tested and found to comply with the limits for a Class A
computing device pursuant to Subpart J of Par t 15 o f FCC ru le s, which are designed to
provide reasonable protection aga in st such interference when operated in a commercial
environment. Operation of this equipmen t in a r esiden t ial area may cause interference in
which case the user will be responsible to take whatev er mea s ur e s nece ssa ry to correct
the interference.
You may find the booklet “How to Identify and Resolve Radio TV Interference Problems”
prepared by the Federal Communications Commission helpful. It is available from the U.S.
Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4.
Proper Disposal
When this device reaches the end of its useful life, it must be pr op er ly disp ose d of . I t mu st
not be disposed of as unsorted municipal waste. Within the Eur o pean Union, this device
should be returned to the distributor from where it was purchased for proper disposal. This
is in accordance with EU Directive 2002/96/ EC. Wit hin North America, the device should be
disposed of in accordance with the local laws regarding the disposa l of waste electrical and
electronic equipment.
It is everyone’s responsibility to help maintain the environment and to reduce
the effects of hazardous substances contained in electr ica l and electronic
equipment on human health. Please do your part by making certain that this
device is properly disposed of. The symbol shown to the right indicates that
this device must not be disposed of in unsorted municipal waste progr ams.
8526-M260-O1 C Series Operation
3
I
SPECIFICATIONS
Model:
C6
C15
C30
C65
Capacity and Division Value
6 lb x 0.0005 lb (3 kg x 0.2g)
15 lb x 0.001 lb (7.5 kg x 0.5g)
30 lb x 0.002 lb (15 kg x 1g)
65 lb x 0.005 lb (30 kg x 2g)
Display: WEIGHT = 6 Digits
Avg Piece Weight = 6 Digits
PIECES = 6 Digits
Scale Size: 13.39" W x 13.39" D x 5.00" H
(340 mm x 340 mm x 127 mm)
Platform Size: 12.60" W x 9.06" D
(320 mm x 230 mm)
Power: Built-in rechargeable 6v/4Ah battery or 12VDC /110~240 VAC 50/60Hz
AC adapter
Temperature: 32° ~ 104°F (0° ~ 40°C)
Humidity: 25% ~ 95% RH
Zero: Established on power up routine and maintained by auto-zero circuitry
Tare: 100% of full scale capacity
Serial Number_____________________
Date of Purchase __________________
Purchased Form___________________
_________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
PRECAUTIONS
Before using this scale, read this manual
and pay special attention to all
NOTIFICATION symbols:
Before beginning installation of your C Series Digital Counting Scale, make certain the scale
has been received in good condition. Carefully remove the scale from the shipping carton
and inspect it for any evidence of damage (su c h as exterior dents or scratches) that m ay
have taken place during shipment. Keep the carton and packing material for return
shipment if it should become necessary. It is the responsibility of the purchaser to file all
claims for any damages or loss incurred during transit.
Placement
Place the scale on a stable, vibration-f r ee level sur face away from direct sunlight and from
any rapidly moving air source (heating/cooling ven ts, fans, etc.). Make certain the powe r
cord and peripheral cables are routed out of the way of normal traffic.
CAUTION! DO NOT place the scale on any unstable cart, stand or t able. The
scale may fall causing injury to the operator, a nd seriously damage the unit,
or proper operation of the scale may be inhibited.
Level Adjustment
Check to make certain the scale is level. The level indicator is
located at the front of the scale. If the scale is not level (the bubble
will not be centered), loosen the locking ring on all four ( 4) mo un ting
feet and adjust them as required to cent er the bubble and attain a
level scale. Once a level condition has been obt ain ed , lock the
mounting feet in place by tightening the adjust m en t locking ri ng s
against the bottom of the scale.
Power Connection
The scale contains a power supply that conver ts the 110/120/220/240 VAC 50/60Hz wall
supply to the power required by the scale circuitry. The power supply also contains the
circuitry necessary to monitor and rechar ge the battery and is capable of operating the sca le
and recharging the battery simultaneously.
AC Operation
Plug the power cord into a grounded, polariz ed wall r ecep tacle that supplies 110/120 VAC
50/60Hz power. If it is necessary to use an extension co r d, make cert ain it is a 3-wire, fully grounded type using a minimum of 18-gauge wire. Be certain the power cord is rout ed out
of the way of normal traffic. If only an ung r ou nde d wall re cep tacle is available, it is the customer's responsibility to contact a qualifie d electrician to replace the ungrounded
receptacle with a properly grounded polarized wall recep tacle or have a grounding adapter
properly installed.
WARNING! To avoid electrical hazard, DO NOT under any circumstances,
cut, remove, alter, or in any way bypass the power cord-grounding prong.
It is the responsibility of the customer to contact a qualified electrician to install the
proper power cord connector. Plug th e power cord into a grounded, polarized wa ll
receptacle that supplies 220/240 VAC 50/60Hz power. Be certain the power cord is routed
out of the way of normal traffic.
Not Level Level
8526-M260-O1 C Series Operation
1
PRECAUTIONS
Most scales are designed for an office type environment. The C Series Digital Counting
Scale is no exception to that rule. The following should be used as a guideline for the
proper environment to operate you r scale:
The environment should be free of excessive dust and moisture.
Provide a comfortable temperature. In general, the scale will perform well over a
temperature range of 32 to 104° F (0 to +40° C).
To keep cooling requirements to a minimum, the scale should be placed out of direct
sunlight and to provide adequate air circulation, keep the area around the scale clear.
Make certain the scale is not directly in front of a heatin g or co oling vent . Such a location
will subject the scale to sudden temperature changes and air currents that may resu lt in
unstable weight readings.
Insure that the scale has good, clean AC power and is properly gro un ded . In areas
subject to lightning strikes, additio na l pr otection to minimize lightning damage, such as
surge suppressors, should be installed.
CARE AND CLEANING
1. DO NOT submerge the scale in water, pour or spray water directly on it.
2. DO NOT use acetone, thinner or other volat ile solvent s for cleaning.
3. DO clean the indicator with a damp soft cloth and mild non-abrasive detergent .
4. DO remove power before cleaning with a damp cloth.
5. DO clean and store the scale in a plastic bag (in a dry environment) if the sca le is not
going to be used for some time. A desiccant packet may be included to pr e ven t moisture
build up.
6. DO recharge the internal battery every three months while in storage.