Be sure to read this instructions before you use the equipment.
Keep this instructions on hand for reference to ensure optimum preformance.
MS350-02_cover08.6.5, 3:30 PM3
FCC REGULATIONS (For 120V models)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy, and if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Do not make any changes or modifications to the equipment unless otherwise specified in the manual. If
such changes or modifications should be made, you could be required to stop operation of the equipment.
RADIO INTERFERENCE REGULATIONS (For 120V models)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus
set out in the Interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the
Industry Canada.
RÈGLEMENT SUR LE BROUILLAGE RADIOÉLECTRIQUE (For 120V models)
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils
numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Appareils Numériques",
NMB-003 édictée par l'lndustrie Canada.
MODEL NAMES
Model Microfilm Scanner 350II is identical to model M31025.
Model Microfilm Scanner 350II is the sales name of model M31025.
• Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and
other countries.
• ISIS is a trademark of EMC Corporation in the United States.
• Kodak is a trademark of Eastman Kodak Company.
• 3M is a trademark of Minnesota Mining Manufacturing Company.
• TUSCAN is a trademark of the TUSCAN Corporation.
Other brand and product names may be trademarks or registered trademarks of their respective companies.
MS350-02_cover08.6.5, 3:30 PM4
INTRODUCTION
These instructions describe the operating procedures for the Canon
Microfilm Scanner 350II. After you set up the unit, keep this manual
in a convenient location so you can find it when you need it.
CE-IE-335-0107.5.14, 14:191
1
Conventions
A few symbols and notations alert you to additional information
that will make operation of the scanner more efficient, trouble
free, and safe.
(➞P.13)
A number preceded by an arrow and enclosed in parentheses shows
you the page number that contains more information about the
previous statement or paragraph.
WARNING
Warnings are provided for your safety and contain extremely important information. Failure to observe the
instructions provided in a warning could result in death
or serious injury to yourself or your co-workers.
CAUTION
Caution notices are also provided for your safety and
contain important information. Failure to observe the
instructions provided in a caution notice could result in
serious injury to yourself or your co-workers or damage to the equipment.
HEAT CAUTION
There will be cautions for heat injury caused by hot
sections. For your safety, be sure to follow instructions
given in these cautions.
Important
These important notes contain important information
on procedures that must be followed or actions that
must be avoided. Failure to observe a request could
result in damage to the equipment or a malfunction.
Notes
Notes provide additional tips or advice that can save
your time and effort in using the scanner.
INDEX .................................................................................................... 57
4
CE-IE-335-0107.5.14, 14:194
■ BEFORE YOU BEGIN ... ■
50cm
10cm
10cm
BEFORE YOU BEGIN ...
To ensure safe, efficient operation, read the follow precautions
and recommendations before you choose a location and set up the
system.
Work Safety!
Choosing a safe location
■ To ensure adequate space for ventilation, operation, and maintenance, make sure there is enough space around the system on all
sides. To prevent overheating, never block the ventilation slots.
■ Avoid exposure to direct sunlight. When exposure to sunlight is
unavoidable, install curtains to protect the unit.
■ Avoid a dusty location. Dust can adversely affect the internal parts
of the unit.
■ Do not set up and use the unit in a location where the unit is exposed to water, steam, or high humidity. Keep all liquids away
from the unit.
5
CE-IE-335-0107.5.14, 14:195
■ BEFORE YOU BEGIN ... ■
■ Avoid areas like laboratories where fumes from ammonia, acetone,
or other volatile chemicals are present. Never use any kind of
volatile, flammable spray near the unit.
■ Never set up the unit in an area where flammable substances like
alcohol, thinner, or other organic chemicals are present.
■ Select a flat, stable surface that can support the 26 kg (57.2 lb)
weight of the unit.
■ Choose a location that is free of excessive vibration.
■ Avoid a location subject to sudden or wide changes in tempera-
ture. Condensation inside the unit can cause poor image quality.
Use the unit in a location within these ranges for temperature and
humidity.
Temperature10˚C to 32.5˚C (50˚F to 90.5˚F)
Humidity10% to 80% RH
Use Fileprint in a work environment that is suitable for Fileprint.
■ Do not place the unit near large speakers, a radio, a television, or
any other type of equipment that can generate a strong magnetic
field.
6
CE-IE-335-0107.5.14, 14:196
■ BEFORE YOU BEGIN ... ■
Power supply
If you have any questions about the power source at
your work site, contact your supplier or the power company.
■ The unit should have an independent power source that is not
shared with any other electrical device. If you have to use an extension cord or power strip, make sure the total ampere rating for
all the equipment does not exceed the ampere rating of the extension cord.
■ Do not place anything on the power cord, and do not locate the
unit where people working around the unit will walk on the cord.
■ Do not bundle the power cord or wrap it around an object like a
table or chair leg. The area around the unit should be clear of all
obstacles. In case of an emergency, you should be able to reach
the power source quickly to unplug the cord.
■ To remove the power cord from the power outlet, grasp the head
of the plug firmly to remove it. Never pull on the cord to remove
the plug from the power outlet. Never touch the power cord with
wet hands.
CE-IE-335-0107.5.14, 14:197
7
■ BEFORE YOU BEGIN ... ■
Daily handling
Before using the equipment, make sure you and your co-workers
read the following warnings about using this equipment.
PAY ATTENTION TO THESE WARNINGS! FAILURE
TO FOLLOW THESE WARNINGS COULD RESULT
IN INJURY FROM FIRE OR ELECTRICAL SHOCK!
WARNING
■ Always observe these warnings when using the scanner. Failure
to follow these warnings could result in injury due to fire or electric shock.
■ Do not set up the scanner in a location close to flammable solvents such as alcohol and paint thinners.
■ Do not cut, damage or modify the power cord, do not pull or bend
the power cord excessively, and do not place heavy objects on the
power cord.
■ Never plug in or unplug the power cord with wet hands.
■ Do not place objects on top of the scanner as such objects could
fall and cause injury. Do not plug the scanner into a multi-socket
adapter.
■ Do not knot or bundle the power cord, and ensure that the plug is
pushed fully into the power outlet.
■ Use only the power cord supplied with the scanner.
■ Do not attempt to disassemble or modify the scanner. There are
no user-serviceable parts inside the scanner.
■ Do not use flammable sprays or aerosols near the scanner.
■ Switch the scanner off and unplug the power cord before cleaning
the scanner.
■ To clean the unit, use a cloth lightly dampened with water or a
mild detergent.
■ If the scanner emits an unusual noise, odor, smoke or sparks, or if
the scanner will not function when switched on, immediately
switch the scanner off, unplug the power cord and contact an authorized Canon dealer or service center.
■ Before you move the scanner even a short distance, switch the
scanner off and unplug the power cord.
8
CE-IE-335-0107.5.14, 14:198
CAUTIONS
■ Do not set up the scanner on sloping, wobbly or otherwise unstable surfaces or in locations affected by excessive vibration. The
scanner could cause injury if it falls over or slides off the surface.
■ Do not block the ventilation slots as this could result in a fire due
to the build up of heat inside the scanner.
■ Do not place vessels containing liquids (cups, vases, etc.) or small
metal objects (paper clips, staples, necklaces, etc.) on top of the
scanner. Liquids or metal objects falling into the scanner could
cause an electric shock or fire. If any liquids or metal objects fall
into the scanner, immediately switch the scanner off, unplug the
power cord and contact an authorized Canon dealer or service
center.
■ Do not set up the scanner in dusty or humid locations as this could
result in an electric shock or fire.
■ Do not place heavy objects on top of the scanner as such objects
could fall and cause injury.
■ BEFORE YOU BEGIN ... ■
■ Use only a power supply having the rated voltage. The use of
other voltages could result in a fire or electric shock.
■ Always unplug the power cord by grasping the plug itself. Pulling
on the power cord can damage the cord so that the core wires are
exposed or snapped and could cause a fire or electric shock.
■ Do not use an extension power cord as this could cause a fire or
electric shock.
■ Keep the area around the power outlet free of obstacles to ensure
that the scanner can be unplugged quickly in the event of an emergency.
■ Take care not to tip water or flammable solvents such as alcohol,
thinners or benzene into the scanner as this could result in a fire or
electric shock.
■ If the scanner will be left unused for a lengthy
period, always unplug the scanner as a safety measure.
■ Avoid touching internal scanner components when you perform
routine cleaning or maintenance such as changing the lamp. Some
internal components generate high temperatures or high voltages.
To avoid injury such as burns or electric shocks, take care also
that metal objects such as necklaces or bracelets do not come into
contact with internal scanner components.
■ To avoid injury when you are moving the scanner, take care not
to put your hands on the metalprotrusions on the underside
of the scanner unit.
HEAT CAUTIONS
■ Avoid touching internal scanner components when you perform
routine cleaning or maintenance such as changing the lamp. Some
internal components generate high temperatures or high voltages.
CE-IE-335-0107.5.14, 14:199
9
■ BEFORE YOU BEGIN ... ■
Features of the Microfilm Scanner 350II
❏ Space saving
The economical design of this compact film scanner requires less
space on your desk or work table.
❏ Internal SCSI-USB converter
SCSI-USB converter is built-in, so you can use both SCSI and
USB interfaces. See “Preparing the computer (scanner
mode)”(➞P.21)
❏ Automatic film polarity detection
The unit automatically detects the presence of negative film or
positive film and sets itself accordingly.
❏ Uses a variety of film formats
A wide variety of roll/fiche carriers or auto carriers can be installed so you can use several film formats like microfiche, aperture card, and roll film.
❏ Easy operation
Operations like border removal and image trimming can be performed at the press of a few keys before scanning.
❏ Reader-Printer mode (CapturePerfect)
This is a mode which enables the scanner to perform the same
Reader-Printer functions as a Microfilm printer does. Scanned images can be printed out directly through a designated printer.
❏ Expandability
By adding the optional DMP board, sold separately, in the Microfilm Scanner 350II, the scanner can be used as a Digital Microfilm Printer (DMP).
Before you use the equipment, make sure you and your co-workers read the following warnings about using this equipment.
10
CE-IE-335-0107.5.14, 14:1910
■ BEFORE YOU BEGIN ... ■
About operation modes
The following operating modes are available with this scanner.
Select one of the following modes according to your system environment before using the scanner. For details, contact your service representative.
❏ Scanner mode
Using this scanner in connection with a personal computer, the
image projected on the scanner’s screen can be saved in the PC as
image data, or printed out through a printer connected to the PC.
❏ DMP mode
By installing the optional DMP board in the scanner and connecting it to a DMP-dedicated printer, the MS350II can be used as a
digital microfilm printer (DMP). The image projected on the
scanner’s screen can be printed out through the DMP-dedicated
printer. In this case, no personal computer is required.
❏ Reader-printer mode
Using the CapturePerfect bundled with the MS350II, the scanner
that is set to the Scanner mode will operate as if it is set to the
DMP mode. The image projected on the scanner’s screen can be
printed out directly through a printer connected to the personal
computer. In this case, however, the image cannot be saved in the
PC as image data.
When the DMP board is installed in this scanner, switch
the “DMP mode” and “scanner mode” in the user mode
before use. (➞P.45 “USER MODE”)
If the computer is connected with the user mode set to
“DMP mode” when the DMP board is installed in this
scanner and the MS350II is used as a scanner, the
operation panel may not be operable or other problems may occur.
CE-IE-335-0107.5.14, 14:1911
11
■ BEFORE YOU BEGIN ... ■
Unpacking: What's in the box?
When you unpack the box, use the checklist below to make sure
that you have everything. If anything is missing, contact your supplier.
■ Microfilm Scanner 350II
■ Keyboard
■ Lens holder
■ Setup CD
ISIS/TWAIN Driver
CapturePerfect
■ USB cable
■ Power cord
■ Function Key label (➞P.39 “Setting the function keys (DMP
mode)”)
■ Instructions (This manual)
■ Canon Software License Agreement
■ Warranty Card (U.S.A. and Canada only)
12
CE-IE-335-0107.5.14, 14:1912
■ BEFORE YOU BEGIN ... ■
Options
In addition to the accessories provided in the product package, a
number of optional accessories that are required for using the scanner, such as carriers and lenses, are also sold, as well as other
optional accessories that can be purchased as needed. Contact your
nearest authorized Canon Dealer for details.
■ Carriers (➞P.17 “Preparing the carrier”)
Multiple carriers can be used for all types of film, including cartrige
film, microfiche, jacket film and aperture cards.
Since the scanner does not come with a carrier, purchase the carrier best suited to your needs.
■ Installation Kit (➞P.17“Preparing the carrier”)
Some carriers require an Installation Kit. Contact your nearest
authorized Canon service outlet for details.
■ Lenses (➞P.18 “Preparing the lens”)
One fixed-focus lens and five zoom lenses are available for the
Microfilm Scanner 350II. Since the scanner dose not come with a
lens, purchase the lenses best suited to your needs.
■ DMP board
This optional board is required to use the scanner in the DMP
mode.
■ Fileprint 270/470 (➞P.20 “Preparing optional printer (for the DMP
mode)”)
These printers are DMP-dedicated printers that support the scanner when used in the DMP mode.
■ Framing Kit (➞P.37 “Trimming”)
This optional unit allows you to selectibely scan a portion of the
image projected onto the screen. This Framming Kit is required
in order to use the Trimming function provided by the scanner.
■ Foot switch
This is an underfoot switch that provides the same function as the
Start key on the operational panel.
CE-IE-335-0107.5.14, 14:1913
13
■ BEFORE YOU BEGIN ... ■
Operation panel
Provides keys that allow you to perform
settings for image adjustment or film
mode selection.
Important parts and their functions
Before you use the unit, take a few minutes to become familiar
with the names of the important parts.
Screen
Displays images and allows you to view
images before you print them.
DIN connector
Allows you to connect a
cable for the Autocarrier
100C, FS Controller I or
Roll/Fiche carrier 200.
Power switch
Allows you to turn power on and off.
Carrier stage
Holds an interchangeable carriers.
Lens holder
Holds an interchangeable
lens.
Lamp unit
Holds the lamp for the main
source of illumination. Remove
to change the halogen lamp.
Keyboard
Use to adjust the screen image, set
the print mode, execute printing, and
control almost all other operations.
14
CE-IE-335-0107.5.14, 14:1914
Operation panel and keyboard keys
Operation panel keys
This is a summary of the keys on the operation panel.
1 Negative/Positive keyThree settings are available:
( ) In negative film mode produces positive output from nega-
tive film images.
( ) In positive film mode, produces positive output from posi-
tive images.
■ BEFORE YOU BEGIN ... ■
( A ) In automatic mode, selects the mode based on the type of
film detected.(➞P.36)
2 Trimming/Border keyUse this key to trim the image to be scanned or to remove the
black border around the image.(➞P.37)
3 Brightness indicatorShows the brightness adjusted using the brightness adjustment
key.
4 Brightness adjustment keysUse the or key to adjust brightness of the image manually,
or the use AE key to adjust it automatically. In the DMP mode,
this applies to brightness for printing.
5 Print/Error DisplayDisplays the number of prints (01 to 99) in case of the Reader-
Printer mode. Also displays error message(User and Service
releated).
6 Print number setting keyUse these keys to set the number of prints to make for each
image in the Reader-Printer mode or the DMP mode (➞P.11).
Also use them to set various settings or confirm the SCSI ID of
the scanner.
7 Clear/Stop keyStops scanning or resets the number of prints. Also defines an
area for trimming, or defines a specified time for the power
saver mode.
When the scanner is connected to the Fileprint 470 and used in
the DMP mode, this key is also used to switch to the cassette
select mode (➞P.43).
8 Start keyIn the case of the Scanner mode: press this key to start scan-
CE-IE-335-0107.5.14, 14:1915
ning with the “Panel Start” set to on in the application, or to
start scanning in the Reader-Printer mode (➞P.11).
In the case of the DMP mode: press this key to start printing.
The Print/Error display stays blinking from the time the key is
pressed until the time scanning begins.
15
■ BEFORE YOU BEGIN ... ■
Keyboard keys
This is a summary of the keyboard keys.
9 Function keysThe following functions are assigned on the respective keys
before factory shipping. For details, refer to P.39 “Setting the
function keys (DMP mode).”
P1: DATE
P2: NOTE
P3: PICTURE
P4: SHARPNESS
!0 Cassette Select keySelects paper cassette for printing when the scanner is con-
nected with the Fileprint 470.
!1 Auto Rotate keyRotates the image 90 degrees for printing.
!2 Zoom keysUse these keys to register zoom settings. During normal
operation, you can immediately switch to one of the registered
settings by pressing the key.
!3 Rotate keysPress this key to rotate the image left or right by 90 degrees.
!4 Reset keyUse this key to restore or change default settings.
!5 Film Control knob (optional)Transports film through a motorized carrier. Turn the knob
right to advance the film forward, or left to rewind it. (Note
that this knob cannot be used with the FS Controller I.)
!6 Adjust Mode indicatorsThe illuminated lamp identifies the type of image adjustment
!7 Image Adjust Select keySelects the type of adjustment you can make: Zoom magnifica-
!8 Image Adjust Control dialUse this dial to adjust the magnification, focus or rotation.
16
CE-IE-335-0107.5.14, 14:1916
you can make. You can switch the adjustment type by pressing
the Image Adjust Select key.
tion, Focus, or Rotation.
■ BEFORE YOU BEGIN ... ■
Preparing the carrier
This is a list of all the carriers that can be installed and used with
the Microfilm Scanner 350II. For more details about these options, contact your supplier. For details about installation and operation, refer to the instructions provided with each auto carrier.
Some carriers require an optional Installation Kit.
■ Fiche Carrier 190RII
A microfish carrier which allows viewing of fiche, jackets, or aperture cards up to 105 mm x 190 mm.
■ Autocarrier 100C (AC100C)
A motorized auto carrier for 16 mm cartridge films (ANSI, ANSI
ENCLOSED*1, Kodak Ektamate, 3M) that features fast autoloading and high speed film transport.
■ FS Controller I
A motorized auto carrier for 16 mm cartridge films (ANSI, Kodak
Ektamate, 3M). This carrier is required for reading film marked
with blips for automated image search and retrieval.
■ Roll/Fiche Carrier 200
A motorized fiche auto carrier for either fiche, jacket, or aperture
card format film, 16mm/35mm film standard open reels or 3M,
TUSCAN M-Type*2 cartridges.
*1 ANSI ENCLOSED cartridge is defined as ANSI MS-15.
2
*
TUSCAN M-Type is a TUSCAN cartridge with a 3M-type core.
CE-IE-335-0107.5.14, 14:1917
17
Loading...
+ 43 hidden pages
You need points to download manuals.