CANOGA PERKINS L351 ESU User Manual

Quick Start Guide
L351 ESU
This document provides instructions for installation and initial configuration of the Canoga Perkins model L351 ESU (Ethernet Service Unit). The EdgeAccess L351 Ethernet Service Unit
is a managed Ethernet and Fast Ethernet Compliant device that supports native 10Mbps and 100Mbps Transparent LAN extension circuits. The L351 offers 10/100 auto sensing or software configurable User Interface and a variety of optical network interfaces. The L351 is modular and hot swappable with a common form factor to mount in Canoga Perkins’ Carrier Class Universal Chassis System (UCS) as well as a variety of Customer Premise Enclosures (CPE).
Parts List
1 x L351-xxxx 1 x UCS 1000 or UCS 1002 chassis 1 x UCS 1001 chassis 1 x UCS 1230 BAM (Bus Access Module) 1 x Model 1020-2100 (management access CPE) or 1030-2200 (unmanaged CPE) 1 x EIA-232 serial cable (straight) 1 x EIA-232 to DB9 converter (Canoga Perkins p/n CRJ-D9F-10)
Step 1: Unpacking
Unpack the L351 and check the unit for damage. If the unit is damaged, contact Canoga Perkins’ Tech Support line, (800) 360-6642, and ask for an RMA.
Step 2: Module Set Up
Before installation into a chassis or enclosure, you must verify the application in which the L351 will be used, i.e. 10Mbps or 100Mbps Ethernet, managed or non-managed etc. The application may require setting the dip switches located at the rear of the L351. If the unit is to be installed in the UCS 1030 enclosure, set the L351 to the desired configuration using Table 1 as a reference. Otherwise, the L351 can be configured through software to the desired configuration when installed in the UCS 1000, 1001, 1002 or 1020.
Figure 1. L351 Switches and Default Setting
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008
Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com
P/N 6942580 Rev A Page 1 of 8
SW2 (User Port Configurations)
100 User Port Speed 100Mbps 10Mbps (Default) A User Port Autonegotiate Enabled (Default) Disabled F User Port Duplex Full Duplex Half Duplex (Default) N Not Used N/A N/A (Default)
Function
On Off
Table 1. SW2 settings
SW3 (Extension Port Configurations)
S SideBand Management Enabled (Default) Disabled
Link Loss Forwarding
L
U
E
Extension port to User port Link Loss Forwarding
User port to Extension port Enabled Disabled (Default)
Extension port LLE (Link Loss Echo) or RMTF (Remote Fault)
Function
On Off
Enabled Disabled (Default)
Disables LLE Enables LLE and Disables RMTF
and Enables RMTF
(Default)
Table 2. SW3 settings
Step 3: Module Installation
Several options for installation are available for the L351. For applications requiring multiple modules in the same location, depending on the size and quantity requirements, the UCS 1000 or 1002 chassis may be used. The UCS 1000 chassis, in conjunction with model 1230 BAM, can accommodate up to 30 L351s and the UCS 1002 can accommodate up to 14 L351s. The L351 is also hot-swappable module and it can be inserted any time without interruption of service to other modules.
Insert the L351 in an available slot in the 1230 or UCS 1002 making sure that the unit is lined-up with the card guides. The module should slide into the slot with ease and make contact with the rear connector without excessive force. Tighten the thumbscrew after insertion. The same steps apply when installing in the UCS 1020 or 1030. See Figures 2 to 5.
Figure 2. L351 in UCS 1230 and UCS 1000 chassis
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008
Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com
P/N 6942580 Rev A Page 2 of 8
Figure 3. L351 in UCS 1002 chassis
Figure 4. L351 in UCS 1230 and UCS 1001 chassis
Figure 5. L351 in UCS 1020 management access customer premise enclosure
Figure 6. L351 in UCS 1030 customer premise enclosure
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008
Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com
P/N 6942580 Rev A Page 3 of 8
Loading...
+ 5 hidden pages