CANOGA PERKINS 1040 User Manual

Model 1040 Standalone Enclosure User Manual
NOTICE!
This device contains static sensitive components. It should be handled only with proper Electrostatic Discharge (ESD) grounding procedures.
NOTE!
Cet équipement contient des composants sensibles aux décharges électro-statiques. Il doit absolument être manipulé en respectant les règles de mise à la terre afin de prévenir de telles décharges.
NOTICE
Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, operation and/or maintenance of Canoga Perkins equipment. The drawings, specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings, specifications and information is prohibited.
Canoga Perkins reserves the right to change or update the contents of this manual and to change the specifications of its products at any time without prior notification. Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision. However, no guarantee is given or implied that the document is error free or that is accurate with regard to any specification.
2
Canoga Perkins Corporation
20600 Prairie Street
Chatsworth, California 91311-6008
Business Phone: (818) 718-6300
(Monday - Friday 7 a.m. - 5 p.m. Pacific Time)
FAX: (818) 718-6312 (24 hrs.)
Web Site: www.canoga.com
Email: fiber@canoga.com
Copyright© 2003 - 2005 Canoga Perkins Corporation
All Rights Reserved
®
EdgeAccess
Product Number 6913100
EdgeAccess Model 1040
Universal Chassis System
Model 1040
User Manual
Model Number 1040-UM
Rev. D 01/2008

Model 1040 Standalone Enclosure User Manual

The Model 1040 standalone enclosure, shown in Figure 1, supports one 5U-sized managed module.
Figure 1. Model 1040 Standalone Enclosure
The front provides two switches, five LEDs, one connector, and a slot for a module. The back includes an AC power cord socket and the ALM IN and ALM OUT connectors.
Switch Setting Selects
F1/NRM/F2 for the module F1 Function 1, such as Local loopback NRM Normal operation; set this for most applications F2 Function 2, such as Remote loopback HDX/FDX for 10BASE-T port HDX Half duplex FDX Full duplex
Note: If the link partner is set to auto-negotiation, the link uses 10M and follows the HDX/FDX
switch setting for this port; otherwise, set this switch to match the other switch on the link.
LED State Definition
PWR Off No power Green Power is on ALARM, MAJ and MIN Off Normal MIN Amber Minor alarm MAJ Red Major alarm Tx for 10BASE-T port Off No transmission Green blinking Transmission activity LNK/Rx for 10BASE-T port Off No link Green Link is established at full duplex Amber Link is established at half duplex Blinking Data is received
Note: To clear a latched Minor or Major alarm, push the ACK button.
Connector Provides
ALM IN and ALM OUT, MIN and MAJ Alarm status from another device (IN) and to
another device (OUT)
10BASE-T Half or full duplex Ethernet
EdgeAccess Model 1040
3

Installing and Using the 1040 Enclosure

To use the 1040 enclosure, see Figure 1 and follow these steps:
1. Place it on a secure surface with room for air flow and within 7 ft. (2.134 m) of the AC power source.
2. Insert a module in the guide rails and press it firmly into the backplane, then secure the thumbscrews finger-tight.
3. At ALM OUT, on the rear panel, connect devices to receive alarm information; see Figure 2.
NO The contacts are open for normal operation and closed in a fault condition
COM The electrical common
NC The contacts are closed for normal operation and open in a fault condition
4. At ALM IN, on the rear panel, connect devices to supply alarm information; see Figure 2. Connect cabling from the + output on the device to IN+ on the 1040 and from the - output to IN­on the 1040; the internal alarm sense circuit is optically protected. Connect an optional Frame or Chassis Ground to FGND.
Figure 2. Model 1040 Alarm Connectors
5. Plug the power cord into the rear of the 1040 enclosure, then plug it into the AC power source; this turns on the power. To turn off the power, unplug the power cord.
6. To set any switches on the module, install the module in the 1040 enclosure, connect all cables, and access the module, see the User Manual for the module.

Specifications

Dimensions: 11.70"L x 12.0"W x 1.718"H (297 mm x 305 mm x 44 mm) Weight: 5.6 lbs (2.5 kg) Power: 115 to 230 VAC; 50 to 60 Hz autoranging, 14 W maximum Operating Environment:
Regulatory Compliance
ETL, cETL (UL 60950 CAN/CSA C22.2 No. 60950, EN/IEC 60950) EN 60825-1, -2
FCC Part 15B/IC-003/VCCI Class A, C-Tick (AS/NZS 3548)
EN 55022 Class A, EN 61000-3-2, EN 61000-3-3
EN 55024
CE Mark
0° to +50°C, Up to 90% humidity (Non-condensing)
4
EdgeAccess Model 1040

Warranty Information

Current Warranty information is available on-line in the Client Login Area of the Canoga Perkins web site (www.canoga.com) or by contacting Technical Support at 800-360-6642 (voice) or fiber@canoga.com (email).
EdgeAccess Model 1040
5
CANOGA PERKINS CORPORATION
20600 Prairie Street
Chatsworth, California 91311-6008 USA
Phone: (818) 718-6300 FAX: (818) 718-6312
Web Site: www.canoga.com
Email: fiber@canoga.com