Cannon FITZIB-PMEXB, FITZIB-PMEXP Instruction Manual

Fitzroy Inbuilt Power Flue Instruction Manual
Please read this manual before installing and using this heater.
Please leave instruction manual with the owner
Distributor
Tel: 1300 727 421
Models: FITZIB-PMEXB FITZIB-PMEXP
Sharing a lifetime of cosy moments
2 | Cannon Fitzroy Inbuilt Power Flue
CONTENTS PAGE
WARRANTY 3
SAFETY WARNINGS 5
OPERATION 6
OPTIONAL ACCESSORIES 7
FITZROY INBUILT POWER FLUE SPECIFICATIONS 8
REGULATORY LOCATOR 9
POWER FLUE INSTALLATION INSTRUCTIONS 10 – 12
FASCIA REMOVAL AND ELECTRICAL CONNECTION 13
LOG INSTALLATION & GAS CONNECTION 14
SETTING THE GAS PRESSURE 15
SERVICE INSTRUCTIONS 16 –17
WIRING DIAGRAM 18
TROUBLESHOOTING 19 – 20
NOTES 21
Cannon Fitzroy Inbuilt Power Flue | 3
WARRANTY
This Warranty against defects for your newly purchased Cannon product is proudly prepared by Sampford IXL Pty Ltd of 421 Smith Street, Fitzroy, VIC 3065, phone 1300 727 421.
1. Sampford IXL products come with guarantees that do not exclude the following consumer entitlements under the Australian Consumer Law:
a. replacement or refund for a major failure and
compensation for any other reasonably foreseeable loss or damage; and
b. to have the goods repaired or replaced if goods fail
to be of acceptable quality and the failure does not amount to a major failure.
2. Sampford IXL warrants that your product and related supply will be free from defects in materials and workmanship during the warranty term. Your warranty term can be found in your original instruction booklet contained in this box, commencing from the date of purchase. Sampford IXL acknowledges this product requires professional installation and product removal is hazardous to consumers, accordingly any necessary inspections and services will be carried out on site. You should not attempt de-installation.
3. Subject to Point 1, Sampford IXL will repair any defects in materials and workmanship during the warranty term and if the product is deemed irreparable provide a replacement of an equivalent current model where the balance of the warranty period from the original date of purchase will take effect.
4. To the fullest extent permitted by law and subject always to Point 1, Sampford IXL will not be liable for:
a. any loss or damage arising from loss of use, loss
of prots or revenue; or
b. for any indirect or consequential loss or damage
resulting from any breach of this warranty against defects.
5. Defective Sampford IXL products may be repaired using refurbished parts or if required, completely replaced by a refurbished product of the same type.
Limitations to Your Cannon Warranty
6. Subject to Point 1, this Warranty:
a. will only be provided to the original purchaser
where the original purchase was made from a Sampford IXL Authorised Dealer or Reseller and proof of such purchase can be presented at the time of service;
b. only applies to Sampford IXL products purchased
in Australia from a Sampford IXL Authorised Dealer or Reseller and installed by a qualied person where a Certicate of Compliance in accordance with State/Territory laws is provided;
c. will not apply where the defect in or failure of
the product is attributable to misuse, abuse, accident or non-observation of the manufacturer’s instructions. This product must be used in accordance with the manufacturer’s instructions;
d. will not cover faults due to normal wear and tear
with reasonable use nor consumable components such as globes, lters, glass items, etc;
e. will not cover any damages or problems caused to
this product by natural forces eg. storm, re, ood, and earthquake; or by intrusion or accumulation (or both) of foreign matters eg. dust, soil, and moisture. Sampford IXL recommends that you take out appropriate insurances to protect your product to this end;
f. will not apply if this product is installed in a mobile
dwelling eg. caravan or boat;
g. will not apply if this product is removed from the
location where it was rst installed;
h. is immediately void if the serial or model number
label is removed or defaced;
i. is immediately void if the product is serviced or
repaired by a unauthorised/unqualied personnel;
j. covers use of this product for domestic use only;
k. will not be restarted or extended upon repair or replacement of the product or a part.
How to Make a Claim Under Your Cannon Warranty
7. To make a claim under this Warranty you will need to:
a. contact Sampford IXL service department on
1300 727 421 or aftersalesservice@sampfordixl. com.au to provide details and register your claim enabling a Sampford IXL assessment;
b. submit proof of purchase with your claim eg. tax invoice or purchase receipt;
c. where a property has been constructed by a
builder/developer and it is tted with IXL products, please submit proof of purchase by way of the certicate of occupancy, with your claim.
8. Sampford IXL will contact you to make arrangements for service on site.
9. Subject to Point 1, you will be responsible for any costs relating to the provision of your product to a Sampford IXL Authorised Service Dealer.
10. Subject to Point 1, in the event you live more than 50 km from a Sampford IXL Authorised Service Dealer you may be subject to travel or transport costs to facilitate the repairing or replacement of your IXL product.
4 | Cannon Fitzroy Inbuilt Power Flue
Don’t risk your appliance warranty
Only a licensed person will give you a
Compliance Certicate, showing that the work
complies with all the relevant standards.
Only a licensed person will have insurance
protecting their workmanship for 6 years.
You MUST use a licensed person to install this
appliance who MUST give you your Compliance
Certicate to ensure the manufacturers appliance
warranty will be honoured.
11. Sampford IXL and its Authorised Service Dealers reserve the right to seek reimbursement of any costs incurred by them should your Cannon product be found to be in good working order.
Privacy
The privacy of your personal information has always been important to us. To learn more about how we collect, keep and use your personal information, please obtain a copy of our privacy statement by visiting our website at www.sampfordixl.com.au or by contacting us via email on info@sampfordixl.com.au or by telephone on 1300 727 421.
Enter the details of the date installed and the Compliance Certicate number in the appropriate area on the rear page of this manual.
DO NOT operate this appliance before reading the
instruction booklet.
DO NOT place articles on or against this appliance.
DO NOT store chemicals or ammable
materials, or spray aerosols near this appliance.
DO NOT operate with panels, covers or guards
removed from this appliance.
DO NOT connect an LP gas cylinder located indoors.
Cannon Fitzroy Inbuilt Power Flue | 5
SAFETY WARNINGS
Please read this manual before installing and using the heater.
Safety Warnings
1. What to do if you smell gas (a) Turn OFF the main gas supply (b) Extinguish any open ame (c) Open windows (d) Do not touch electrical switches (e) Do not use your telephone (f) Call your gas supplier immediately from a neighbour’s phone
2. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the sections of this manual for correct proce­dures, or consult with place of purchase, a licensed plumber, a gas supplier or the CANNON distributor listed in this manual.
3. Install the heater only in locations that are referred to in the installation instructions. Do not build the heater into bookcases, walls or enclosures (combustible materials) without the use of an insulating blanket & stand off brackets tted (supplied with heater).
4. Due to high temperatures the room heater should be located out of trafc and away from:
• Furniture and draperies
• Combustible materials
• Gasoline and other ammable liquids
Do not place clothing or other ammable
material on or near the heater.
5. Keep curtains*, clothes, furniture and other ammable materials at least 900mm from front and sides of heater. * At the owner’s discretion curtain clearance can
be less than 900mm as long as they are restrained from the front, top and sides of the heater. The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained.
6. Children and adults should be alerted to the hazard of high surface temperature and should take care to avoid burns or clothing ignition.
This appliance is not intended for use by
persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concern­ing use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
7. Never attempt to burn paper or any other material in the heater.
8. Do not place articles on or against this appliance.
Do not use or store ammable materials near
this appliance.
Do not spray aerosols in the vicinity of this
appliance while it is in operation
Do not modify this appliance.
9. If removed, the glass window must be put back onto the unit prior to operating the heater.
10. Installation and repairs must be performed by a licensed service person only, refer to back of brochure for service number.
11. For installation into a non-combustible replace, i.e masonry or brick or into a mock replace, i.e. timber or plasterboard, the chimney and base should be of sound construction.
12. On rst lighting your heater an odour and possibly some harmless smoke may be emitted due to its new condition. This is quite normal and will disappear after a few hours use.
Important: When this heater is operating the mesh guard/glass front is hot. The mesh guard, or glass front is tted to this appliance to reduce the risk of re or injury from burns and no part of it should be permanently removed. For protection of young children or the inrm, a secondary guard is recommended (not supplied with heater).
This appliance meets the following standards: Standards Australia AS/NZS 3100 AS 5601 AS 4553:2008
6 | Cannon Fitzroy Inbuilt Power Flue
Operating Instructions
Plug the power cord into the switch socket and turn on the power to the heater (FIG 1). Alternatively, switch on the isolation switch and circuit breaker at the main switchboard if the heater has xed wiring. Refrain from using an extension cord.
User controls FIG 2.
When there is power available to the heater and it is in the OFF or Standby mode, a red LED located inside the ON/OFF button will ash twice and will extinguish after approximately 3 seconds and then repeat this cycle continuously.
To turn the heater ON press the ON/OFF button once.
• The LED will illuminate and an audible beep will sound
but there will be approximately 30 seconds delay before the ignition system commences. On successful ignition the heater will operate on Low Fire and Low Fan for approximately 3 minutes then will switch to selected setting (if already chosen, otherwise will switch to NORMAL settings automatically).
• The LED will extinguish approximately 30 seconds
following the ignition startup.
• Select the desired heating level by pressing the LOW,
NORMAL or BOOST button once as required.
• LOW is LOW heat and LOW speed fan. BOOST is
HIGH heat and HIGH speed fan.
• To turn the heater OFF press the ON/OFF button once. An audible beep will sound twice to indicate the heater is off. The burner will extinguish but the fan will continue to operate for approximately 3 minutes. Remember that the fan will continue to operate for approximately 3 minutes after the OFF button has been pressed but you can turn the heater ON again without having to wait for the fan to stop operating.
• If the ignition system fails to ignite or keep the burner
alight, the system will beep 4 times and go into safe shutdown mode. It will beep 4 times every 30 seconds to alert you to the fact. Press the ON/OFF button once to restart the heater during this time. You MUST wait at least 5 minutes before trying to
OPERATION
FIG 2FIG 1
ON / OFF
LOW
BOOST
NORMAL
turn the heater on again if there have been several attempts to ignite the heater without success.
• If there is an interruption to the power supply the
heater will fail safely and switch off. When the power supply has been restored you MUST wait at least 5 minutes before turning the heater ON.
Cleaning
All cleaning should be carried out when the heater is cold. Normally the heater should only need wiping with a lint-free damp cloth. Any stubborn stains can be removed with a nonabrasive spray on cleaner. If an abrasive cleaner is used the paint nish will be damaged.
For heaters tted with the glass front: All cleaning should be carried out when the heater is cold. Clean the outer glass with a mild liquid or spray on glass cleaner. Do not use harsh abrasive cleaners or sharp metal scrapers to clean the heater glass front since they can scratch the surface, which may result in shattering of the glass.
Internally the heater should only be cleaned by an authorised service person. If your heater requires attention contact your supplier or an authorised service person.
Flame Characteristics
The heater ame should be stable, not lifting from the burner. The logs should glow after approximately 15 minutes operation on BOOST setting.
The heater is designed to operate with luminous ames and may exhibit slight carbon deposit on the logs. If there is any excess carbon build-up on logs, or the burner ame is unstable, contact Sampford IXL in your state.
Important
The appliance MUST be serviced at least annually by an authorised service person. ThIs maintenance cost is not covered under the warranty terms and conditions. More frequent cleaning may be required due to excessive lint build-up from carpeting, bedding materials, pet hair, etc.
It is imperative that control compartments, burners and circulating air passage ways of the appliance be kept clean.
Do not use this heater if the glass is cracked or with the safety screen removed.
Do not use heater with broken or missing logs.
High wind gusts can affect the heaters ueing and switch the heater off. If this happens, restart the heater as normal. If the problem persists contact Sampford IXL.
Cannon Fitzroy Inbuilt Power Flue | 7
OPTIONAL ACCESSORIES
Product codes
• 50 mm spacer kit:
FITZ Black BSPACERX-B FITZ Platinum BSPACERX-P
• Glass kit: FITZDGKITX-B
• 3 sided surround kit:
FITZSURROUND3SX-B (black) FITZSURROUND3SX-P (platinum) FITZSURROUND3SX-S (S/Steel)
• Weather kit: WPBPF
• Fitzroy Powerue console kit:
CONSPWRX-B (black) CONSPWRX-P (platinum)
• Fitzroy spacer: Black: BSPACERX -B (black) Platinum: BSPACERX -P (platinum)
• 4 sided surround (all inbuilts): SURROUND4SX-B (black) SURROUND4SX-P (platinum) SURROUND4SX-S (stainless steel)
• Remote Thermostat: RTKIT
• Extended Flue Kit: FLUEWFX
Versatility and exibility are key components of our instal­lation options. Install in a shallow recess or an existing replace, elegant spacers will eliminate any size discrep­ancies. To enhance your Cannon’s appearance add a decorative 3 or 4 sided surround.
Every Cannon heater brings you the optional convenience of controlling your heater through a remote thermostat.
For added convenience the heater can now be connected to a home automation system, such as C-bus. This allows the heater to be turned on or off remotely (normal heat setting only). Speak to your home automa­tion specialist for further information.
Weatherproof kit
3 Sided surround kit
Console kit 4 Sided surround kit
Fitzroy glass kit
Remote thermostat
Spacer kit
(shown here on a Canterbury heater)
Extended ue kit
8 | Cannon Fitzroy Inbuilt Power Flue
FITZROY INBUILT POWER FLUE SPECIFICATIONS
Cannon Fitzroy Inbuilt Power Flue
FIG 3 Front View and Side View
Gas type Natural or Propane gas,
as indicated on data label Gas consumption 26.0 MJ/hr input Energy output 6.09 kW / 21.92 MJ/hr Energy star rating 5.05 stars Heater type Gas space heater approved
to AS 4553:2008 Operating pressure Natural gas 0.75 kPa (high)
/ 0.40 kPa (low)
Propane gas 2.65kPa (high)
/ 1.1 kPa (low) Gas regulator Integral part of controller Min. inlet pressure 1.13 kPa (NG)
2.75 kPa (Propane) Fan 3 speed Ignition Electronic direct spark Power requirement 240 VAC 10 Amp
switch socket Power consumption 90 VA maximum Minimum cavity Height
Dimensions
605 mm*
Width 700 mm*
Depth 485 mm* Optional accessories Glass front
Remote thermostat
Spacer kit
3 sided surround
4 sided surround
Console kit
Extended ue kit
Weatherproof box Overall dimensions Refer to FIG 3 * For installation into a masonry/brick replace
690 mm
700 – 800 mm
808 mm 386 mm50 mm 50 mm
651 mm
600 mm
Ceiling
Mantle 300 mm min clearance
900 mm min clearance
1000 mm min clearance
For min clearance see Note 2
For min clearance see Note 1
Rear wall of replace
For further detailed ueing methods refer to our website or the installation instruction manual.
Note 1:
485 mm min clearance for straight through ue. 585 mm min clearance for ex ue pipe.
Note 2:
100 mm min clearance for straight through ue. 200 mm min clearance for ex ue pipe.
Loading...