CANNON
FITZROY PROFILE PWR
TO SUIT MOCK FIREPLACE INSTALLATIONS
INSTALLATION INSTRUCTIONS FOR FITMENT
INTO A COMBUSTIBLE ENCLOSURE
This heater is for use with Natural Gas
Read these instructions in conjunction with heater
installation instructions

CONTENTS
ITEM PAGE.
GENERAL AND SAFETY WARNINGS P ge 1
a
CLEARANCE FROM COMBUSTIBLE P ge
a
2
OVERALL DIMENSIONS OF CABINET P ge
a
3
- 5
Pa
4
g
e
FITMENT OF SPACER BRACKETS AND BLANKET
CAVITY CLEARANCE REQUIREMENTS P
a
ge 6
7
INSTALLATION DETAIL ADVICE P g
a e
g
CONTACT FOR MAINTENANCE ATTENTION a 8
e
P

GENERAL
THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED
PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS, AG 5601,
MUNICIPAL BUILDINGS CODES, ELECTRICAL WIRING REGULATIONS
AND ANY OTHER STATUTORY REGULATIONS.
TO CONFORM WITH THE AUSTRALIAN STANDARDS APPROVAL
REQUIREMENTS, THE SPACERS MUST BE PERMANENTLY FITTED
TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLE
MATERIALS.
THESE MOCK FIREPLACE INSTALLATION INSTRUCTIONS AND
SAFETY WARNINGS SHALL BE READ IN CONJUNCTION WITH THE
HEATER INSTALLATION BOOKLET AND THE SAFETY WARNING IN
THAT MANUAL. (SEE PAGES 3&4)
Page 1.
IMPORTANT NOTE:
WHEN INSTALLING THIS POWER FLUE HEATER INTO A MOCK
FIREPLACE , A MOCK FIREPLACE INSTALLATION KIT MUST BE USED.
FOR INSTALLATION INTO A (MOCK) COMBUSTIBLE FIREPLACE
CONSTRUCTED FROM TIMBER AND / OR PLASTERBOARD, THE FLUE
WILL NEED TO BE SUPPORTED TO MAINTAIN MIN CLEARANCES
FROM ANY COMBUSTIBLE MATERIALS.
THE HEATER MUST BE INSTALLED WITH IT’S INTEGRAL FLUE
CORRECTLY INSTALLED (SEE INSTALLATION INSTRUCTION BOOKLET)
FOR THIS HEATER TO OPERATE PROPERLY. IF THE FLUE SYSTEM
IS NOT CORRECTLY INSTALLED AND MAINTAINED, POISONING BY
CARBON MONOXIDE (CO) COULD RESULT AND POSSIBLY CAUSE
DEATH.
THE APPLIANCE SHOULD BE INSPECTED PRIOR TO USE, WITH
REGULAR INSPECTIONS (ANNUALLY) TO BE MADE BY A LICENSED
SERVICE PERSON. IT IS IMPORTANT THAT CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN, DIRT AND LINT
FREE, FOR A SAFE AND EFFICIENT OPERATION OF THE HEATER.
SAFETY WARNINGS

CLEARANCE FROM COMBUSTIBLES.
(SEE FIG 1.)
MIN 630 mm
MAX 650 mm
MIN 745 mm
MAX 840 mm
CLEARANCE FROM COMBUSTIBLES.
BETWEEN HEATER CABINET AND OTHER
COMBUSTIBLE SURFACES.
* 50 mm CLEARANCE FROM BOTH TOP
AND SIDE SURFACES.
* 50 mm CLEARANCE FROM REAR.
* 50 mm CLEARANCE BETWEEN SIDE OF
THE HEATER FRONT AND
COMBUSTIBLES.
ADDITIONAL CLEARANCES ARE SPECIFIED.
(SEE FIG 6, PAGE 6)
FIG 1.
Page 2.
DEPTH OF CAVITY : MIN 440 mm
MAX 740 mm