Cannon FFITZROY PROFILE PWR Installations

CANNON
FITZROY PROFILE PWR
TO SUIT MOCK FIREPLACE INSTALLATIONS
INSTALLATION INSTRUCTIONS FOR FITMENT
INTO A COMBUSTIBLE ENCLOSURE
This heater is for use with Natural Gas
Read these instructions in conjunction with heater
CONTENTS
ITEM PAGE.
GENERAL AND SAFETY WARNINGS P ge 1
a
CLEARANCE FROM COMBUSTIBLE P ge
a
2
OVERALL DIMENSIONS OF CABINET P ge
a
3
- 5
Pa
4
g
e
FITMENT OF SPACER BRACKETS AND BLANKET
CAVITY CLEARANCE REQUIREMENTS P
a
ge 6
7
INSTALLATION DETAIL ADVICE P g
a e
g
CONTACT FOR MAINTENANCE ATTENTION a 8
e
P
GENERAL
THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS, AG 5601, MUNICIPAL BUILDINGS CODES, ELECTRICAL WIRING REGULATIONS AND ANY OTHER STATUTORY REGULATIONS.
TO CONFORM WITH THE AUSTRALIAN STANDARDS APPROVAL REQUIREMENTS, THE SPACERS MUST BE PERMANENTLY FITTED TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLE MATERIALS.
THESE MOCK FIREPLACE INSTALLATION INSTRUCTIONS AND SAFETY WARNINGS SHALL BE READ IN CONJUNCTION WITH THE HEATER INSTALLATION BOOKLET AND THE SAFETY WARNING IN THAT MANUAL. (SEE PAGES 3&4)
Page 1.
IMPORTANT NOTE: WHEN INSTALLING THIS POWER FLUE HEATER INTO A MOCK FIREPLACE , A MOCK FIREPLACE INSTALLATION KIT MUST BE USED.
FOR INSTALLATION INTO A (MOCK) COMBUSTIBLE FIREPLACE CONSTRUCTED FROM TIMBER AND / OR PLASTERBOARD, THE FLUE WILL NEED TO BE SUPPORTED TO MAINTAIN MIN CLEARANCES FROM ANY COMBUSTIBLE MATERIALS.
THE HEATER MUST BE INSTALLED WITH IT’S INTEGRAL FLUE CORRECTLY INSTALLED (SEE INSTALLATION INSTRUCTION BOOKLET) FOR THIS HEATER TO OPERATE PROPERLY. IF THE FLUE SYSTEM IS NOT CORRECTLY INSTALLED AND MAINTAINED, POISONING BY CARBON MONOXIDE (CO) COULD RESULT AND POSSIBLY CAUSE DEATH.
THE APPLIANCE SHOULD BE INSPECTED PRIOR TO USE, WITH REGULAR INSPECTIONS (ANNUALLY) TO BE MADE BY A LICENSED SERVICE PERSON. IT IS IMPORTANT THAT CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN, DIRT AND LINT FREE, FOR A SAFE AND EFFICIENT OPERATION OF THE HEATER.
SAFETY WARNINGS
CLEARANCE FROM COMBUSTIBLES.
(SEE FIG 1.)
MIN 630 mm MAX 650 mm
MIN 745 mm MAX 840 mm
CLEARANCE FROM COMBUSTIBLES.
BETWEEN HEATER CABINET AND OTHER COMBUSTIBLE SURFACES.
* 50 mm CLEARANCE FROM BOTH TOP AND SIDE SURFACES.
* 50 mm CLEARANCE FROM REAR.
* 50 mm CLEARANCE BETWEEN SIDE OF THE HEATER FRONT AND COMBUSTIBLES.
ADDITIONAL CLEARANCES ARE SPECIFIED. (SEE FIG 6, PAGE 6)
FIG 1.
Page 2.
DEPTH OF CAVITY : MIN 440 mm MAX 740 mm
Loading...