Cannon Canterbury, Fitzroy Instruction Manual

Inbuilt Heater Instruction Manual
Please read this manual before installing and using this heater.
Please leave instruction manual with the owner
Distributor
This appliance is designed, manufactured and distributed by:
FitzroyCanterbury
2 | Cannon Fitzroy / Canterbury Inbuilt
CONTENTS PAGE
WARRANTY 2
SAFETY WARNINGS 3
OPERATION 4
OPTIONAL ACCESSORIES 5
INBUILT: FITZROY SPECIFICATIONS 6
INBUILT: CANTERBURY SPECIFICATIONS 7
FITZROY & CANTERBURY INBUILT INSTALLATION INSTRUCTIONS 8 – 9
FITZROY & CANTERBURY INBUILT FLUING OPTIONS 10
FITZROY INBUILT FASCIA REMOVAL 11
CANTERBURY INBUILT FASCIA REMOVAL 11
ELECTRICAL CONNECTION & SEALING THE FASCIA 12
LOG INSTALLATION & GAS CONNECTION 13
SETTING THE GAS PRESSURE 14
SERVICE INSTRUCTIONS 15 –16
WIRING DIAGRAM 17
TROUBLESHOOTING 18 – 19
WARRANTY
Don’t risk your appliance warranty.
Only a licensed person will give you a
Compliance Certificate, showing that the work
complies with all the relevant standards.
And only a licensed person will have insurance
protecting their workmanship for 6 years.
So make sure you use a licensed person to install this
appliance and ask for your Compliance Certificate
to ensure the manufacturers
appliance warranty will be honoured.
The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product that consumers have under the Trade Practices Act and similar laws of the States and Territories.
We warrant this Cannon appliance to be free of defects in materials, workmanship and manufacturing to the original purchaser for 2 years, (10 years on the heat exchanger) from the date of original purchase. We will, at our option and subject to the terms of this warranty, repair or replace free of charge this Cannon appliance or any component part, which upon examination by us or our repair agent is found to be defective in materials, workmanship or manufacturing. However, this warranty does not cover any consumables (if any).
The purchaser must present the original purchase receipt to us when making any claim under this warranty.
This warranty will not apply if: (i) a compliance label or serial number (as the case may be) has been removed from the appliance or rendered illegible; (ii) the appliance has been subject to misuse, abuse, accident, incorrect installation or non-domestic use; (iii) the appliance has been modified, tampered with or repaired by a person other than our authorised repair agent; (iv) the appliance is re-installed/relocated during the warranty period.
The purchaser is responsible for all travelling expenses if the purchaser requests any repair be carried out at a place outside areas normally serviced by our repair agents.
Should you require service on this appliance, please contact our service department on 1300 727 421.
Enter the details of the date installed and the Compliance Certificate number in the appropriate area on the rear page of this manual.
DO NOT operate this appliance before reading the
instruction booklet.
DO NOT place articles on or against this appliance.
DO NOT store chemicals or flammable
materials, or spray aerosols near this appliance.
DO NOT operate with panels, covers or guards
removed from this appliance.
Cannon Fitzroy / Canterbury Inbuilt | 3
8. If removed, the glass window must be put back onto the unit prior to operating the heater.
9. Installation and repairs should be performed by a licensed service person only, refer to back of brochure for service number.
10. For installation into a non-combustble fireplace, i.e masonry or brick or into a mock fireplace, i.e. timber or plasterboard, the chimney and base should be of sound construction and be free from cracks and holes (to ensure that sufficient flue draught can be generated).
Note: when installing into a mock fireplace a mock fireplace installation kit must be used. (Part No. MOCKKITUNI)
11. The heater must be properly installed in a working chimney or mock fireplace with flue. Operation of this heater, when not connected into a working chimney or a properly installed and maintained flueing system can result in carbon monoxide (CO) poisoning and possi­ble death.
12. Testing the effectiveness of the flue: Before testing the flue confirm air vents are unobstructed. If an exhaust fan or other heating appliances are present switch them on. This is to test that there is no interaction between the Cannon heater and other appliances.
Refer to Australian Standard Gas Installations AS 5601.
For ‘air movement not to affect appliance’ see clause
5.3.1.
For ‘air supply to appliance’ see clause 5.4.1.
For ‘ventilation requirements’ see clause 5.4.3.
13. The appliance should be inspected prior to use, with regular inspections (annually) to be made by a licensed service person. It is important that circulating air passageways of the appliance be kept clean, dirt and lint free, for safe and efficient operation of the heater.
14. On first lighting your heater an odour may be emitted due to its new condition. This is quite normal and will disappear after a few hours use at the maximum control position.
Important: When this heater is operating the mesh guard/glass front is hot. The mesh guard, or glass front, is fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently removed. For protection of young chil­dren or the infirm, a secondary guard is required.
This appliance meets the following standards: Standards Australia AS/NZS 3100 AS 5601 AS 4553:2008
SAFETY WARNINGS
Please read this manual before installing and using the heater.
Safety Warnings
1. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the sections of this manual for correct proce­dures, or consult with place of purchase, a licensed plumber, a gas supplier or the CANNON distributor listed in this manual.
2. Install the heater only in locations that are referred to in the installation instructions. Do not build the heater into bookcases, walls or enclosures (combustible materials) without the use of a Mock Fireplace kit.
3. Due to high temperatures the room heater should be located out of traffic and away from: Furniture and draperies Combustible materials Gasoline and other flammable liquids
Do not place clothing or other flammable
material on or near the heater.
4. Keep curtains*, clothes, furniture and other flammable materials at least 900mm from front and sides of heater. * At the owner’s discretion curtain clearance can
be less than 900mm as long as they are restrained from the front, top and sides of the heater. The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained.
5. Children and adults should be alerted to the hazard of high surface temperature and should take care to avoid burns or clothing ignition.
This appliance is not intended for use by
persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concern­ing use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
6. Never attempt to burn paper or any other material in the heater.
7. Do not place articles on or against this appliance.
Do not use or store flammable materials near
this appliance.
Do not spray aerosols in the vicinity of this
appliance while it is in operation
Do not modify this appliance.
4 | Cannon Fitzroy / Canterbury Inbuilt
Operating Instructions
Plug the power cord into the wall socket and turn on the power to the heater (FIG 1). Alternatively, switch on the isolation switch and circuit breaker at the main switch­board if the heater has fixed wiring. Refrain from using an extension cord.
User controls FIG 2.
When there is power available to the heater and it is in the OFF or Standby mode, a red LED located inside the ON/OFF button will flash twice and will extinguish after approximately 3 seconds and then repeat this cycle continuously.
To Turn the heater ON press the ON/OFF button once.
• TheLEDwillilluminateandanaudiblebeepwillsound
but there will be approximately 5 seconds delay before the ignition system commences. On success­ful ignition the heater will operate on Low Fire and Low Fan for approximately 3 minutes then will switch to selected setting (if already chosen, otherwise will switch to Medium settings automatically).
• TheLEDwillextinguishapproximately30seconds
following the ignition startup.
• SelectthedesiredheatinglevelbypressingtheLOW,
MEDIUM or HIGH button once as required.
• LOWisLOWheatandLOWspeedfan.HighisHigh
heat and High speed fan.
• ToturntheheaterOFFpresstheON/OFFbutton once. An audible beep will sound twice to indicate the heater is off. The burner will extinguish but the fan will continue to operate for approximately 3 minutes. Remember that the fan will continue to operate for approximately 3 minutes after the OFF button has been pressed but you can turn the heater ON again without having to wait for the fan to stop operating.
• Iftheignitionsystemfailstoigniteorkeeptheburner
alight, the system will beep 4 times and go into safe shutdown mode. It will beep 4 times every 30 seconds to alert you to the fact. Press the ON/OFF button once to restart the heater during this time. Wait at least 20 seconds before attempting to turn the heater on.
OPERATION
ON / OFF
LOW
HIGH
MEDIUM
FIG 2FIG 1
• Ifthereisaninterruptiontothepowersupplythe
heater will fail safely and switch off. When the power supply has been restored adopt the 20 seconds waiting rule before turning the heater ON.
Cleaning
All cleaning should be carried out when the heater is cold. Normally the heater should only need wiping with a lint-free damp cloth. Any stubborn stains can be removed with a nonabrasive spray on cleaner. If an abrasive cleaner is used the paint finish will be damaged.
For heaters fitted with the glass front: All cleaning should be carried out when the heater is cold. Clean the outer glass with a mild liquid or spray on glass cleaner. Do not use harsh abrasive cleaners or sharp metal scrapers to clean the heater glass front since they can scratch the surface, which may result in shattering of the glass.
Internally the heater should only be cleaned by an authorised service person. If your heater requires attention contact your supplier or an authorised service person.
Flame Characteristics
The heater flame should be stable, not lifting from the burner. The logs should glow after approximately 15 minutes operation on HIGH setting.
The heater is a fuel effect unit and is designed to operate with luminous flames and may exhibit slight carbon deposit on the logs. If there is any excess carbon build-up on logs, or the burner flame is unstable, contact Sampford IXL in your state.
Important
The appliance should be inspected before use and at least annually by an authorised service person. More frequent cleaning may be required due to excessive lint build-up from carpeting, bedding materials, pet hair, etc.
It is imperative that control compartments, burners and circulating air passage ways of the appliance be kept clean.
Do not use this fire if the glass is cracked or with the safety screen removed.
Do not use fire with broken or missing logs.
Cannon Fitzroy / Canterbury Inbuilt | 5
OPTIONAL ACCESSORIES
Product codes
•50mmspacerkit
CANT model BSPACERE-B FITZ Black BSPACERX-B FITZ Platinum BSPACERX-P
•FITZGlasskit:FITZDGKITX-B
•3sidedsurroundkit:
CANT model CANTSURROUND3SX-B (black) CANTSURROUND3SX-S (S/Steel) FITZ models FITZSURROUND3SX-B (black) FITZSURROUND3SX-P (platinum) FITZSURROUND3SX-S (S/Steel)
•Fitzroyfreestandingkit:
FITZFSKITX-B
•ConsoleKit:
Fitzroy console kit: CONSFITZX-B (black) CONSFITZX-P (platinum) Canterbury console kit:
CONSCANT-B (black)
•Mockreplacekit (all open flue inbuilts): MOCKKITUNI
•4sidedsurround: SURROUND4SX-B (black) SURROUND4SX-P (platinum) SURROUND4SX-S (stainless steel)
•Canterburymeshkit:CANTIBMG-B
•RemoteThermostat:RTKIT
Versatility and flexibility are key components of our instal­lation options. If installed into a shallow recess or an existing fireplace, elegant spacers will eliminate any size discrepancies. To enhance your Cannon’s appearance add a decorative 3 or 4 sided surround.
Every Cannon heater brings you the optional convenience of being controlled via a remote thermostat.
For added convenience the heater can now be connected to a home automation system, such as C-bus. This allows the heater to be turned on or off remotely (low heat setting only). Speak to your home automation specialist for further information.
Mock fireplace kit
Fitzroy freestanding kit
3 sided surround kit
Console kit
4 sided surround kit
Canterbury mesh guard
Fitzroy glass kit
Remote thermostat
Spacer kit
6 | Cannon Fitzroy / Canterbury Inbuilt
INBUILT: FITZROY SPECIFICATIONS
Gas type Natural or Propane gas,
as indicated on data label
Gas consumption 26.0 MJ/hr
Energy output 5.98 kW / 21.45 MJ/hr
Energy star rating 4.05 stars
Heater type Gas space heater approved
to AS 4553:2008
Operating pressure (at burner high setting)
Natural gas 0.75 kPa Propane gas 2.65 kPa
Gas regulator Integral part of controller
Min. inlet pressure 1.13 kPa (NG)
2.75 kPa (Propane)
Fan 3 speed
Ignition Electronic direct spark
Power requirement 240 VAC 10 Amp
Power consumption 90 VA maximum
Minimum cavity dimensions
Height 605 mm* Width 700 mm* Depth 405 mm*
Optional accessories •Glassfront
•Remotethermostat
•Spacerkit
•3sidedsurround
•4sidedsurround
•Consolekit
Overall dimensions Refer to FIG 3
*For installation into a non-combustible fireplace, ie: masonry or brick
Please Note:
•Wheninstallingintoamockreplaceamock fireplace installation kit must be used.
•Thedatalabelislocatedinthefanchamber.Access
by removing fascia.
Cannon Fitzroy Inbuilt
FIG 3 Front View and Side View
808 mm 50 mm 347 mm 8 mm
651 mm
600 mm
Loading...
+ 14 hidden pages