HPR1XX
SERIES DC/DC CONVERTER |
|
POWER ELECTRONICS DIVISION |
||||||
|
|
|
|
|||||
|
|
|
|
|
Product Site: www.cdpowerelectronics.com |
|||
|
|
POWER: 0.75 Watt |
|
|
||||
|
|
|
|
|||||
|
|
|
|
Corporate Site: www.cdtechno.com |
||||
|
|
OUTPUT: Single Output |
|
|
|
|
|
|
|
|
SIZE: Multiple Package Styles |
|
|
|
|
|
|
|
PRODUCT DATA SHEET |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FEATURES |
|
|
|
|
||||
|
|
|
|
|||||
Low Cost |
High Output Power Density: |
|||||||
Multiple Package Styles |
10 Watts/Inch3 |
|||||||
|
|
|
|
Internal Input and Output |
Extended Temperature Range: |
|
-25°C to +85°C |
||
Filtering |
||
Efficiencies to 79% |
||
Non-Conductive Case |
||
|
The HPR1XX Series uses advanced circuit design and packaging technology to deliver superior reliability and performance. A 170kHz push-pull oscillator is used in the input stage. Beatfrequency oscillation problems are reduced when using the HPR1XX Series with high frequency isolation amplifiers.
Reduced parts count and high efficiency add to the reliability of the HPR1XX Series. The high efficiency of the HPR1XX Series means less internal power dissipation, as low as 190mW. With reduced heat dissipation the HPR1XX Series can operate at higher temperatures with no degradation. In addition, the high
efficiency of the HPR1XX Series means the series is able to offer greater than 10 W/inch3 of output power density. Operation down to no load will not impact the reliability of the series, although a >1mA minimum load is needed to realize published specifications.
The HPR1XX Series provides the user a low cost converter without sacrificing reliability. The use of surface mounted devices and advanced manufacturing technologies make it possible to offer premium performance and low cost.
Absolute Maximum Ratings
..........................................Internal Power Dissipation |
450mW |
ShortCircuitDuration .................................................. |
Momentary |
Lead Temperature (soldering, 10 seconds max ........... |
.+300°C * |
|
|
* NOTE: Refer to Reflow Profile for SMD Models.
Ordering Information
HPR 1XX V/W
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected from Table of Electrical Characteristics
Package Option
There is "no" package designator for the SIP package
V = DIP Package
W = SMD Package
C&D Technologies (Power Electronics) Ltd. |
Power Electronics Division, United States |
C&D Technologies, (NCL) |
|
Shannon, Co. Clare, Ireland |
3400 E Britannia Drive, Tucson, Arizona 85706 |
Milton Keynes |
MK14 5BU UK |
Tel: +353.61.474.133 Fax:+353.61.474.141 |
Tel: 800.547.2537 Fax: 520.770.9369 |
Tel: +44 (0)1908 615232 |
Fax: +44 (0)1908 617545 |
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
HPR1XX REV K 8/01 |
Page 1 |
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
|
NOMINAL |
RATED |
RATED |
INPUT CURRENT |
|
REFLECTED |
|
|
|
INPUT |
OUTPUT |
OUTPUT |
|
|
|
RIPPLE |
|
|
|
|
|
|
||||
|
VOLTAGE |
VOLTAGE |
CURRENT |
NO LOAD |
RATED LOAD |
|
CURRENT |
EFFICIENCY |
MODEL |
(VDC) |
(VDC) |
(mA) |
(mA) |
(mA) |
|
(mAp-p) |
(%) |
|
|
|
|
|
|
|
|
|
HPR100 |
5 |
5 |
150 |
20 |
216 |
10 |
69 |
|
HPR101 |
5 |
12 |
62 |
20 |
212 |
5 |
70 |
|
HPR102 |
5 |
15 |
50 |
20 |
212 |
5 |
71 |
|
HPR103 |
5 |
±5 |
±75 |
20 |
218 |
5 |
68 |
|
HPR104 |
5 |
±12 |
±30 |
20 |
212 |
5 |
68 |
|
HPR105 |
5 |
±15 |
±25 |
20 |
200 |
5 |
75 |
|
|
|
|
|
|
|
|
|
|
HPR106 |
12 |
5 |
150 |
10 |
90 |
5 |
69 |
|
HPR107 |
12 |
12 |
62 |
10 |
81 |
5 |
77 |
|
HPR108 |
12 |
15 |
50 |
10 |
81 |
5 |
77 |
|
HPR109 |
12 |
±5 |
±75 |
10 |
88 |
5 |
71 |
|
HPR110 |
12 |
±12 |
±30 |
10 |
81 |
5 |
74 |
|
HPR111 |
12 |
±15 |
±25 |
10 |
81 |
5 |
77 |
|
|
|
|
|
|
|
|
|
|
HPR112 |
15 |
5 |
150 |
8 |
72 |
5 |
69 |
|
HPR113 |
15 |
12 |
62 |
8 |
72 |
5 |
69 |
|
HPR114 |
15 |
15 |
50 |
8 |
72 |
5 |
69 |
|
HPR115 |
15 |
±5 |
±75 |
8 |
72 |
5 |
69 |
|
HPR116 |
15 |
±12 |
±30 |
8 |
63 |
5 |
76 |
|
HPR117 |
15 |
±15 |
±25 |
8 |
63 |
5 |
79 |
|
|
|
|
|
|
|
|
|
|
HPR118 |
24 |
5 |
150 |
8 |
48 |
15 |
65 |
|
HPR119 |
24 |
12 |
62 |
8 |
48 |
15 |
65 |
|
HPR120 |
24 |
15 |
50 |
8 |
45 |
15 |
69 |
|
HPR121 |
24 |
±5 |
±75 |
8 |
45 |
15 |
69 |
|
HPR122 |
24 |
±12 |
±30 |
8 |
45 |
15 |
67 |
|
HPR123 |
24 |
±15 |
±25 |
8 |
45 |
15 |
69 |
|
|
|
|
|
|
|
|
|
|
Note: Other input to output voltages may be available. Please contact factory.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER |
CONDITIONS |
MIN |
TYP |
|
MAX |
UNITS |
INPUT |
|
|
|
|
|
|
Voltage Range |
|
4.5 |
5 |
|
5.5 |
VDC |
|
|
10.8 |
12 |
|
13.2 |
VDC |
|
|
13.5 |
15 |
|
16.5 |
VDC |
|
|
21.6 |
24 |
|
26.4 |
VDC |
|
|
|
||||
Voltage Rise Time |
See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters" |
|||||
|
|
|
|
|
|
|
ISOLATION |
|
|
|
|
|
|
Rated Voltage |
|
750 |
|
|
|
VDC |
Test Voltage |
60 Hz, 10 Seconds |
750 |
|
|
|
Vrms (1060pk) |
Resistance |
|
|
10 |
|
|
GΩ |
Capacitance |
|
|
25 |
|
100 |
pF |
Leakage Current |
VISO= 240VAC, 60Hz |
|
2 |
|
8.5 |
µ Arms |
OUTPUT |
|
|
|
|
|
|
Rated Power |
|
|
750 |
|
|
mW |
Voltage Setpoint Accuracy |
Rated Load, Nominal VIN |
|
45 |
|
±5 |
% |
Ripple & Noise |
BW = DC to 10MHz |
|
|
|
mVp-p |
|
|
BW =10Hz to 2MHz |
|
30 |
|
|
mVrms |
HPR103 |
BW = DC to 10MHz |
|
90 |
|
|
mVp-p |
Voltage (Over Input Voltage Range) |
1mA Load, VOUT = 5V |
|
|
|
7 |
VDC |
|
1mA Load, VOUT = 12V |
|
|
|
15 |
VDC |
Temperature Coefficent |
1mA Load, VOUT = 15V |
|
.01 |
|
18 |
VDC |
|
|
|
|
%/°C |
||
|
|
|
|
|
|
|
REGULATION |
|
|
|
|
|
|
Line Regulation |
High Line to Low Line |
|
1 |
|
|
%/%Vin |
|
|
|
|
|
|
|
GENERAL |
|
|
|
|
|
|
Switching Frequency |
|
|
170 |
|
|
kHz |
Frequency Change |
Over Line and Load |
|
24 |
|
|
% |
Package Weight |
|
|
2 |
|
|
g |
MTTF per MIL-HDBK-217, Rev. E* |
Circuit Stress Method |
|
|
|
|
|
Ground Benign |
TA = +25°C |
|
7.9 |
|
|
MHr |
Fixed Ground |
TA = +35°C |
|
1.9 |
|
|
MHr |
Naval Sheltered |
TA = +35°C |
|
1.2 |
|
|
MHr |
Airborne Uninhabited Fighter |
TA = +35°C |
|
300 |
|
|
kHr |
|
|
|
|
|
|
|
TEMPERATURE |
|
|
|
|
|
|
Specification |
|
-25 |
+25 |
|
+85 |
°C |
Operation |
|
-40 |
|
|
+100 |
°C |
Storage |
|
-40 |
|
|
+110 |
°C |
|
|
|
|
|
|
|
*For demonstrated MTTF results reference Power Convertibles Reliability Report HPR105
Page 2 |
HPR1XX REV K 8/01 |