Campbell Hausfeld FP209800, IN626701AV User Manual

Operating Instructions and Parts Manual FP209800
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Oilless Compressors
Description
Oilless compressors are designed for do-it-yourselfers with a variety of home and automotive jobs. These units operate without oil. Compressed air from this unit will contain moisture. Install a water filter or air dryer if application requires dry air.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates an
imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates a
potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a
potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Make sure to tighten fittings, bolts, etc., before putting unit into service. In case of questions, damaged or missing parts, please call 1-800-543-6400 for customer assistance.
DO NOT RETURN THE
STOP!
Record the Model No., Serial No. and date of purchase located on the base below the pump in the space below.
Model No. _______________________ Date Code _______________________ Date of purchase _________________
Retain these numbers for future reference.
Have the date code, model number, and parts list (with missing parts circled before calling.)
Do not operate unit
shipping, handling or use. Damage may result in bursting and cause injury or property damage.
PRODUCT TO THE RETAILER! CALL
1-800-543-6400
if damaged during
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
GENERAL SAFETY INFORMATION
Since the air compressor and other components used (filters, lubricators, hoses, etc.), make up a high pressure pumping system, the following safety precautions must be observed at all times:
Breathable Air Warning
This compressor/pump is not equipped and should not be used “as is” to supply breathing quality air. For any application of air for human consumption, the air compressor/ pump will need to be fitted with suitable in-line safety and alarm equipment. This additional equip­ment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breath­ing as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associa­tions (CSA).
DISCLAIMER OF WARRANTIES In the event the compressor is used
for the purpose of breathing air ap­plication and proper in-line safety and alarm equipment is not simul­taneously used, existing warranties shall be voided, and Campbell Haus­feld disclaims any liability whatso­ever for any loss, personal injury or damage.
1. Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.
2. Follow all local electrical and safety codes as well as in the US, National Electrical Codes (NEC) and Occupational Safety and Health Act (OSHA).
MANUAL
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2010 Campbell Hausfeld/Scott Fetzer
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
IN626701AV 3/10
Oilless Compressors
General Safety Information (Continued)
3. Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.
4. Keep visitors away and NEVER allow children in the work area.
5. Wear safety glasses and use hearing protection when operating the pump or unit.
6. Do not stand on or use the pump or unit as a handhold.
7. Before each use, inspect compressed air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.
8. Check all fasteners at frequent intervals for proper tightness.
Motors,
electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor. Never operate or repair in or near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor.
Compressor parts may be hot even if the unit is stopped.
9. Keep fingers away from a running
compressor; fast moving and hot parts will cause injury and/or burns.
10. If the equipment should start
to abnormally vibrate, STOP the engine/motor and check immediately for the cause. Vibration is generally a warning of trouble.
11. To reduce fire hazard, keep engine/
motor exterior free of oil, solvent, or excessive grease.
Never remove or
attempt to adjust safety valve. Keep safety valve free from paint and other accumulations.
Never
attempt to repair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn or damaged tanks.
Drain liquid from
tank daily.
13. Tanks rust from moisture build-up,
which weakens the tank. Make sure to drain tank daily and inspect periodically for unsafe conditions such as rust formation and corrosion.
14. Fast moving air will stir up dust
and debris which may be harmful. Release air slowly when draining moisture or depressurizing the compressor system.
15. Indoor use only.
16. To reduce the risk of electrical shock,
do not expose to rain. Store indoors.
SPRAYING PRECAUTIONS
Do not
spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit.
17. Do not smoke when spraying paint,
insecticides, or other flammable substances.
18. Use a face mask/
respirator when spraying and spray in a well ventilated area to prevent health and fire hazards.
19. Do not direct paint or other sprayed
material at the compressor. Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor.
20. When spraying or cleaning with
solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer.
Installation
LOCATION
It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.
A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.
Do not locate the
compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor.
GROUNDING INSTRUCTIONS
1. This product is for use on a nominal
120 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 1. Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Improper
use of grounding plug can result in a possible risk of electrical shock!
Do not use a
grounding adapter with this product!
RESET
TEST
Grounding Pin
Figure 1 - Grounding Method
Grounded Outlet
www.chpower.com
2
FP209800
Installation (Continued)
2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire.
Never connect
green (or green and
yellow) wire to a live terminal.
3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician.
Overheating, short
circuiting and fire damage will result from inadequate wiring, etc.
Operation
DEFINITION OF TERMS ON / OFF Switch ( I / O ) - Push
switch to the ON ( I ) position to turn compressor on. Push switch to the OFF ( O ) position to turn compressor off. This switch should be in the OFF ( O ) position when connecting / disconnecting power cord from electrical outlet or when changing tools.
ON Position OFF Position
Figure 3
Pressure Switch (located internally)-
When the compressor is turned ON, this switch will shut compressor off automatically when tank pressure reaches maximum shut-off / cut-out pressure. If compressor remains on and air is depleted from tank, this switch will allow compressor to automatically restart at the restart / cut-in pressure.
Regulator - The regulator controls the amount of air pressure released at the hose outlet. Turning the regulator knob clockwise (to the right) will increase air pressure at the outlet. Turning the knob
Pressure Gauge
Regulator Knob
Air Outlet
Drain Valve
Figure 2 - Unit Identification
counter-clockwise (to the left) will lower air pressure to the outlet. Turning knob fully counter-clockwise will shut off flow of air completely.
Pressure Gauges - There are two gauges located next to the regulator. These gauges read air pressure in pounds per square inch (psi) The larger gauge shows pressure at the outlet. Make sure this gauge reads ZERO (by adjusting the regulator) BEFORE changing air tools or disconnecting hose from outlet. The small gauge shows pressure in the tank indicating compressor is building pressure properly.
ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
Handle - Designed to move the compressor.
Motor Reset - (not shown, located inside motor). Designed to keep the motor from overheating. The motor has an auto reset protector. To reset once the motor has cooled, turn the switch to the OFF position, then to the ON
position. Drain Valve - This valve is located on
the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.
Figure 4
Handle
ON/OFF Switch
Safety Valve
LUBRICATION
This is an oilless product and DOES NOT require lubrication to operate.
BEFORE FIRST START-UP BREAK-IN PROCEDURE
(Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise (to the right) to open air flow.
2. Do not attach a hose or any other fitting to the compressor.
3. Turn on/off switch to OFF position.
4. Plug in power cord.
5. Turn on/off switch to ON position. Allow compressor to run for 5 minutes.
6. Turn on/off switch to OFF position.
7. Unplug power cord.
BEFORE EACH START-UP OPERATING PROCEDURE
1. Turn switch to OFF ( O ) position and plug in power cord.
2. Turn regulator knob counterclockwise to close air flow.
3. Turn switch to ON ( I ) position.
4. Compressor will build to maximum pressure and shut off.
5. With hose attached to outlet of compressor, attach tire chuck or
other tool to open end of hose.
www.chpower.com
3
Oilless Compressors
Operation (Continued)
6. Adjust regulator to proper pressure for tool or tire. Operate tool per instructions.
As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically.
7. Turn switch to OFF ( O ) position, unplug power cord and drain tank of air when finished using compressor.
Maintenance
Disconnect power source then release all pressure from the system before attempting to install, service, relocate or perform any maintenance.
The compressor should be checked often for any visible problems and the following maintenance procedures should be performed each time the compressor is used.
ASME SAFETY VALVE
Do not remove or
attempt to adjust
the safety valve!
Figure 5
Check the safety valve by performing the following steps:
1. Plug the compressor in and run until shut off pressure is reached (see Operating Procedure).
2. Wearing safety glasses, pull the ring on the safety valve to release pressure from compressor tank. Use your other hand to deflect fast­moving air from being directed toward your face.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture.
3. The safety valve should automatically close at approximately 40-50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced.
DRAIN TANK
With compressor shut off and pressure released, drain moisture from tank by opening drain valve underneath tank.
If the thermal
overload protector is actuated, the motor must be allowed to cool down before start-up is possible.
LUBRICATION
1. Turn ON / OFF switch to the OFF
position.
2. Unplug power cord from wall outlet
and wrap around handle area to prevent damage when not in use.
3. Wearing safety glasses drain tank of
air by pulling the ring on the safety valve. Use other hand to deflect
Figure 6
fast moving air from being directed toward your face.
CLEANING
Turn power OFF and clean dust and dirt from pump cover, tank, and air lines.
IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent over-spray from clogging air filter.
4. Drain tank of condensation by
opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank.
5. Air hose should be disconnected
from compressor and hung open ends down to allow any moisture to drain.
LUBRICATION
This is an oilless type compressor
6. Compressor and hose should be
stored in a cool, dry place.
requiring no lubrication.
THERMAL OVERLOAD PROTECTOR
This compressor
is equipped with a thermal overload protector which will shut off motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently look for the following causes:
1. Low voltage
2. Lack of proper ventilation
www.chpower.com
4
Notes
FP209800
www.chpower.com
5
Oilless Compressors
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Compressor will not run 1. Switch in OFF position
2. No electrical power at wall outlet
3. Compressor has reached automatic shut­off pressure
4. Motor overheated
5. Loose electrical connection
6. ON / OFF switch bad
7. Pressure switch bad
8. Defective motor
Thermal overload protector cuts out repeatedly
Tank pressure drops when compressor shuts off
Compressor runs continuously / air output lower than normal
1. Lack of proper ventilation/room temperature too high
2. Excessive air usage, compressor too small
1. Open tank drain valve
2. Loose connections (fittings, tubing, air hose, any connections, etc.)
3. Tank leaks
1. Excessive air usage, compressor too small
2. Open tank drain valve
3. Loose connections (fittings, tubing, air hose, any connections, etc.)
4. Pump wore out
1. Make sure compressor is plugged in and switch is ON
2. Check circuit breaker or fuse at electrical panel.
3. Release air from tank until compressor restarts automatically
4. Allow compressor to cool for approximately 30 minutes so thermal overload switch will reset. Make sure compressor is run in a clean, well-ventilated area where temperature will not exceed 100°F.
5. Check all electrical connections
6. Replace ON / OFF switch
7. Replace pressure switch
8. Replace pump / motor assembly
1. Move compressor to a clean,well ventilated area where temperature will not exceed 100°F.
2. Decrease usage or purchase unit with higher air delivery (SCFM)
1. Close tank drain valve
2. Check all connections with soap and water solution. If a leak is detected, tighten. Or remove fitting and apply pipe
tape to threads and reassemble.
Do not disassemble
tank first.
3. Check entire tank for leaks with soap and water solution
1. Decrease usage or purchase unit with higher air delivery (SCFM)
2. Close tank drain valve
3. Check all connections with soap and water solution. If a leak is detected, tighten. Or remove fitting and apply pipe tape to threads and reassemble.
4. Replace pump / motor assembly
check valve. With air in tank, bleed
Excessive moisture in discharge air
Safety valve pops open 1. Defective pressure switch
www.chpower.com
1. Excessive water in tank
2. High humidity
2. Defective safety valve
1. Drain tank, tilt tank to remove moisture
2. Move to area of less humidity; use air line filter
1. Replace pressure switch
2. Replace safety valve with genuine replacement part
6
For Replacement Parts or Technical Assistance,
2
FP209800
Call 1-800-543-6400
13
21
20
29
32
10
30
22
19
12b
9
12a
7
16
1
19a
26
18
31
14
28
25
11
Please provide following information:
- Model number
- Serial number (if any)
- Part description and number as shown in parts list
Address parts correspondence to:
Campbell Hausfeld Attn: Customer Service 100 Production Drive
23
Harrison, OH 45030 U.S.A.
Replacement Parts List
Ref. No. Description
1 Shroud assembly FP209536AV 1 2 On/off switch FP204824AV 1
3 Screw 4 Manifold Cover 5 Regulator 6 1-1/2 in. dia. left gauge FP209528AV 1
24
12b
3
4
5
8
6
7 1-1/2 in. dia. right gauge FP209821AV 1 8 Safety valve V-215104AV 1
9 Motor isolator 10 Pressure switch FP209538AV 1 11 Check valve FP209532AV 1 12 Power cord FP209534AV 1
12a Ground screw * 1 12b Strain relief 1
13 Housing screw 14 Nut 15 Drain valve D-1403 1 16 Rubber foot 17 Foot bolt 18 Wire (pressure switch to power
switch)
19 Pump/motor assembly FP209039AV 1
19a Exhaust tube assembly FP202839AV 1
20 Wire clip FP202823AV 1 21 Screw * 1 22 Motor cover 23 5 piece accessory kit FP204008AV 1 24 25 ft. recoil house MP268100AV 1 25 Plastic base 26 Pressure switch tube assembly FP209535AV 1 27 Tank assembly 1 28 Platic caps 4 29 Washered head screw 30 Motor housing Screw 31 Base screw 32 Pressure switch bracket 1
REPLACEMENT PARTS KITS
s
Manifold assembly FP209820AV
n
27
Isolator kit (includes 4) FP209037AV
l
Feet kit FP209522AV
u
Fastener kit FP209041AV
t
Plastic base & motor cover FP209038AV
* Standard hardware item
Not available
Part No. Qty.
s s s
n
u u
l l
FP209523AV 1
t
t
u u u
4 1 1
2
4 4
4 4
1
1
2 4 4
17
18
www.chpower.com
7
Oilless Compressors
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400.
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions noted below.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM
THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT,
FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with
instructions provided in the owner’s manual(s) supplied with compressor. D. Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment. E. Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc. F. Additional items not covered under this warranty:
1. Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or damaged by contact with tools or surroundings.
2. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
3. Cosmetic defects that do not interfere with compressor functionality.
4. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
5. Drain cocks.
6. Damage due to incorrect voltage or improper wiring.
7. Other items not listed but considered general wear parts.
8. Pressure switches, air governors and safety valves modified from factory settings.
9. Belts.
10. Ring wear or valve damage from inadequate filter maintenance.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Replace, at Warrantor’s option, compressor or component which is defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the
purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PROVIDE REPLACEMENT UNDER THIS WARRANTY: Replacement will be scheduled according to the availability of replacement compressor or parts.
This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from State to State or country to country.
www.chpower.com