Function
Descripton (
negative
[ ]
default values
)
F-1 Total Stop. With button connected to terminals 1-2.
[ ] To deactivate it (this is obligatory when thereis no button); [ ] to activate it.
F-2 Input 2-CX setup. Choosing the function activated by the connected device.
[
] To deactivate it; [ ] for the reopening during closing phase function; [ ] for the obstruc-
tion wait function.
F-3 Setup input 2-CY. Choosing the function activated by the connected device.
[
] To deactivate it; [ ] for the closing phase reopening function; [ ] for the obstruction wait
function.
F-19 Automatic closing. The automatic closing timer activates when the leaf reaches the opening
limit-switch. The preset time is adjustable, and is in any case subject to the intervening of any
safety devices and it deactivates after a total safety "stop" or during power outages.
[
…… ] setting between 1 and 60 seconds.
F-21 Preflashing. After a closing command, the luminous LED band connected to the control board
flashes for a settable time before starting the maneuver.
[
] To deactivate it; [ …… ] setting from 1 to 5 seconds.
F-28 Opening speed. Setting the speed during the opening maneuvers, calculated as a percentage.
[
…… ] Setting from 40 to 100% of the motor speed.
F-29 Closing speed. Setting the speed during the closing maneuvers, calculated as a percentage.
[
…… ] Setting from 40 to 80% of the motor speed.
F-30 Opening slow-down. Setting the speed during opening slow-downs, calculated as a percent-
age.
[
…… ] Setting from 20 to 30% of the motor speed.
F-31 Closing slow-down. Setting the speed during closing slow-downs, calculated as a percentage.
[
…… ] Setting from 20 to 30% of the motor speed.
F-34 Travel sensitivity. Setting the obstruction detection sensitivity during maneuvers.
From maximum [
… ] to minimum [ … ] sensitivity.
F-35 Slow-down sensitivity. Setting the obstruction detection sensitivity during slow-downs.
From maximum [
… ] to minimum [ … ] sensitivity.
F-49 Gestione. Setting the turnstile operating modes.
[
] Stand Alone operation; [ ] paired connection operation; [ ] operation from RBM84 access
control; [ ] operation via CRP (Came Remote Protocol).
F-50
Saving data. Saving registered users and all settings in the
.
The function appears only with connected.
[
] To deactivate it; [ ] to activate it.
F-51
Data reading. Uploading all data from
.
The function appears only with connected.
[
] To deactivate it; [ ] to activate it.
F-52 Copy parameters from Master to Slave. See details in the “Paired connection” section.
[
] To deactivate it; [ ] to activate it.
F-53 Antipassback. To prevent a card from being used for two or more consecutive entries in the
same area.
[
] To deactivate it; [ ] to activate it.
Functions details