Camden Door Controls CX-91M-06, CX-91M-06TLS User Manual

CX-91M-06
5502 Timberlea Blvd. Mississauga, Ontario L4W 2T7 905-366-3377 Toll Free: 877-226-3369 www.camdencontrols.com
Installation Instructions
Model Description Features Current Draw
CX-91M-06 Single Basic 480mA @ 12V
CX-91M-06TDS Single adj. timer, door position
switch & bond sensor
SHOCK HAZARD. Care must be taken to keep the power supply and wiring isolated from ground (earth). Use of an ohmmeter to test for shorts is recommended prior to service.
A. 12V DC Input:
B. 24V DC Input:
Unit is delivered from Factory with single jumper ON for 24V operation. Connect the ground (-) lead from a 24V DC power source to terminal 2. Connect the positive (+) lead from a 24V DC power source to terminal.
240mA @ 24V
C. Contacts:
Reed switch dry contacts are rated 0.5 Amp@30V DC/AC. For safe operation, do not exceed this rating. If you normally require a normally open contact, connect to the black and green wire of the PCB. If you normally require a normally closed contact, connect to the black and red wire of the PCB.
Reed Switch
(Sensor)
Green
Black
Red
Printed Circuit Board
Schematic
NC
C
NO
(shown with all options)
IC 1
Timer
VR
Magnet
Power Sele ctor
Jump er
12V DC
24V DC
WhiteBlue Power Supply
Important
Power switch should always be wired as shown below in order to minimize the eect of residual magnetism. Contact Camden for other wiring considerations.
110 V AC
Switch or Solid State
Switching Device
CORRECT
12 or 24
VDC
110 V AC
Switch or Solid State
Switching Device
INCORRECT
12
or
24
VDC