CX-1000/77 Maximinder
Instructions
FEATURES
Dip switch programmable
Adjustable delay from 1 second to 4 hours
LED status indicator shows when relay is energized
ELECTRICAL SPECIFICATIONS
Operating voltage: 12 or 24 VDC (Cut Jumper)
Relay: DPDT 4 amps at 24 VDC
Current consumption: Idle 12mA, operating 60mA
Note: Trigger requires ground input to
activate
DIP SWITCH SETTINGS
S1 - Changes the state of the relay. In the off
position the relay is as shown.
On position the relay mode is reversed
OFF position N/C = N/C, ON position N/C = N/O
S2 - Determines the switch type for the trigger input
OFF requires N/O, ON requires N/C
S3 - Determines if the time selected is in seconds or minĀutes
ON = Minutes, OFF = Seconds
S4 - Determines if the cycle is repeated
ON =Cycle repeated OFF =Cycle not repeated
S5 - 1 second or minute S9 - 16 seconds or minutes
S6 - 2 seconds or minutes S10 - 32 seconds or minute
S7 - 4 seconds or minutes S11- 64 seconds or minutes
S8 - 8 seconds or minutes S12- 128 seconds or minutes
Example: 10 seconds
Set Dip switch S3 OFF (for seconds)
Set Dip switch S6 ON
Set Dip switch S8 ON
2 + 8 =10 seconds