ELECTRIFIED LOCKS,
RELAYS & TIMERS
RELAYS & TIMERS
CX-1000/75
MINIMINDER
FEATURES
CX-1000/75
• ADJUSTABLE DELAY FROM
1-15 SECONDS
• ULTRA COMPACT DESIGN
• 12/24 V DC
• SPDT CONTACTS RATED AT
2 AMPS @ 30V DC
• ACCEPTS N/O DRY INPUTS
• MOUNTING: SUPPLIED WITH DOUBLE-
SIDED FOAM TAPE
• TURN POTENTIOMETER CLOCK-WISE TO
INCREASE TIME; COUNTER CLOCK-WISE
TO DECREASE TIME
DESCRIPTION
Camden Door Controls CX-1000/75 MiniMinder Is a basic easy-to-operate delay on
release timer. The delay is adjustable from 1 to 15 seconds, and is accessed by a
potentiometer on the board. The Form C relay output is rated at 2 amps @ 30V DC.
The input must be a momentary dry contact such as a push or exit switch.
APPLICATION
The MiniMinder is ideal for (de) energizing an electric strike or electromagnet for
an adjustable time period. It is also suitable for automatic door operators that do
not have built in time delays.
The compact design makes the relay ideal for installations where space is at a
premium, for example within the switch box itself.
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9)
Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
RESTROOM CONTROL KITS ANNUNCIATORS TRANSFORMERS POWER SUPPLIES RELAYS & TIMERS DOOR ALARMS MAGNETIC LOCKS ELECTRIC STRIKES

MINIMINDER
TYPICAL APPLICATION
RADIO
REC EIVE R
ELE CTRI C
LOCK
CX-1000/ 7 5
OR
PUSH
TO
EXI T
MiniMinder
12-24 V DC
POWER
SPECIFICATIONS
OPERATING
VOLTAGE: 12/24 V DC
ENCLOSURE: NONE
CURRENT DRAW: 10 MA IDLE, 40 MA OPERATING
RESPONSE TIME: 0.3 SECONDS
INPUT: N/O DRY CONTACT
RELAY OUTPUT: FORM ’C’ (SPDT)
CONTACT RATING: 2 A @ 30V DC
ELECTRICAL LIFE: 100,000 @ RATED CAPACITY
TIME DELAY: 1 - 120 SECONDS
DIMENSIONS: 1 5/8”H x 29/32W” W x 3/4” D
(41mm x 23mm x 19mm)
MOUNTING: DOUBLE SIDED FOAM TAPE
OR
DOO R
OPE RAT OR
0.8”
(20mm)
1/2”
(13mm)
2.7”
(69mm)
FRONT VIEW SIDE VIEW
5502 Timberlea Blvd. Mississauga, ON Canada L4W 2T7 • Toll Free: 1 877 226-3369 (CAMDEN9)
Tel: (905) 366-3377 • Fax: (905) 366-3378 • E-mail: info@camdencontrols.com • www.camdencontrols.com
MKTG-LIT-SP-MINI-R3