Welcome to the Q-POWER 14 User Manual 4
Important Safety Instructions 5
Explanation of Symbols 7
EC Declaration of Conformity 8
1. Welcome to CAMCO 9
1.1 Unpacking 9
2. The Amplifier 10
2.1 The Q-POWER 14 Front 11
2.2 The Q-POWER 14 Rear 11
3. Mains 12
3.1 Mains Supply 12
3.2 Mains Plugs and Cables 12
3.3 On / Off Switch 12
3.4 Mains Voltage Range 13
3.5 Inrush Current Limitation 13
3.6 Mains Power Consumption and Current Draw 14
3.7 FuseProtect™ Limiter - Mains Circuit Breaker selection 15
4. Mounting 16
4.1 Mounting Dimensions Q-POWER 14 16
4.2 Cooling 16
4.3 Fans 16
5. Input and Output Connectors 17
5.1 Analogue Input Connectors 17
5.2 SPEAKON® Loudspeaker Output Connectors 18
6. Operation 19
6.1 Indicators 19
6.1.1 ON LEDs 19
6.1.2 SIGNAL/Protect LEDs (multifunctional) 19
6.1.3 I-OUT Output Current LEDs 19
6.1.4 CLIP LEDs (multifunctional) 19
6.2 Controls 19
6.2.1 Volume Control 19
6.2.2 Gain Selector 19
6.2.3 Clip Limiter Switch 19
6.3 CAMCO USB MCB Updater 20
7. Protections 21
7.1 Power Amp Protection Systems 21
7.1.1 Clip Limiter 21
7.1.2 SOA Protection 21
7.1.3 DC Protection 21
7.1.4 DC Servo 21
7.1.5 Output Current Limiter 21
7.1.6 Underimpedance Limiter 21
7.1.7 Output Short Circuit Protection 21
7.1.8 Thermal Limitation and Protection 21
7.1.9 High Frequency Protection 22
7.2 Mains and Power Supply Protections 22
7.2.1 Inrush Current Limitation 22
7.2.2 Mains Overvoltage Detection 22
7.2.3 Mains Surge Overvoltage Protection 22
7.2.4 Mains Failure Detection 22
7.2.5 Mains Overcurrent Limiter 22
7.2.6 Over Current Protection 22
7.2.7 Fuse / MCB Protection (FuseProtect™ Limiter) 22
7.2.8 Thermal Protection 22
8. Filter Cleaning 23
8.1 Removing the Filter System and Cleaning 23
9. Volume Control Security Cover 24
9.1 Mounting the Volume Control Security Cover 24
10. Troubleshooting 25
10.1 No reaction when switching the amplifier on 25
10.2 All four signal LEDs are red, the green On-LEDs are off 25
10.3 All green On-LEDs are on, but there is no sound 25
10.4 Sound is distorted 25
10.5 Sound is distorted although Clip Limiter is On 25
10.6 Signal and Clip LED of one or more channels are red
intermittently 26
10.7 Output power lower than usual 26
10.8 The amplifier gets hot very quickly 26
10.9 The CAMCO USB MCB Updater application does not
connect to the amplifier 26
11. Specifications 27
12. Typical Performance Diagrams 30
12.1 Gain vs. frequency, 120 W output power 30
12.2 Phase vs. frequency 30
12.3 THD @ 1 kHz vs. input level 30
12.4 THD vs. frequency, 120 W output power 30
12.5 Channel separation vs. frequency @ 3 × 120 W / 4 Ω 31
12.6 DIM100 vs. input level @ 4 Ω load 31
12.7 Common mode rejection ratio vs. frequency 31
12.8 FFT of noise level vs. frequency 31
12.9 Output impedance vs. frequency 32
12.10 Damping factor vs. frequency 32
13. Unit Conversion Equations and Lookup Table 33
13.1 Unit Conversion Equations 33
13.2 Lookup Table 33
14. Warranty Information 34
14.1 Summary of Warranty 34
14.2 Items Excluded from This Warranty 34
14.3 What CAMCO Will Do 34
14.4 How to Obtain Warranty Service 34
14.5 CAMCO Product Improvement 34
15. Service Information 35
16. Maintenance Information 36
17. Decommissioning 36
Company information 37
Changes Made to The Amplifier / Notices 38
Hole template for Volume Control Security Cover 40
Page 4
4 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
INFORMATION FOR USE
Welcome to the Q-POWER 14 User Manual
Please visit our website www.camcoaudio.com for the latest version of this user manual. Please note that the leading version of CAMCO manuals is always the English one.
© Copyright 2015 by CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen
TDA282USERENC
Revision C, 2015-04-14
Page 5
5 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
IMPORTANT SAFETY INSTRUCTIONS
Important Safety Instructions
1. General
The amplifier may only be used in accordance with the information provided in the user manual. Before and during the usage of the amplifier please ensure that all recommendations, especially the safety recommendations as detailed in the user manual, are adhered to.
The Q-POWER 14 amplifier is designed for the amplification of pulsed audio signals. The amplifier should only be connected to speakers with an average impedance as indicated.
2. User Manual
Read the information for use (user manual) and heed all warnings. Keep this user manual in a safe place during the lifetime of the amplifier. The user manual forms an integral part of the amplifier. Reselling the amplifier is only possible if the user manual is available. In case of reselling the amplifier, the reseller has to docu­ment any changes made to the amplifier in writing and pass the documentation on to the buyer.
3. Environments
Use this amplifier only in E1, E2, E3, or E4 environments according to EN55103-2 “Electromagnetic compatibility – Product family standard for audio, video, and audio-visual and entertainment lighting control apparatus for profes­sional use – Part 2: Immunity”.
4. Mounting / Placement
Do not place this amplifier on an unstable cart, stand, tripod, bracket, or table. The amplifier may fall causing serious injury and serious damage to the product. Any mounting of the amplifier should follow the manufacturer´s instructions. Only mounting accessory shall be used which is recommended by the manufacturer.
5. Mains Connection
The amplifier may only be connected to a socket with a protective earth con­nector.
6. Power Cord Protection
Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon them or against them, paying particular attention to cords and plugs and the point where they exit from the amplifier. The disconnection device from mains (mains plug or external all-pole circuit breaker) shall remain readily operable and freely accessible at all times.
7. Heat
Do not use this amplifier near any heat sources such as radiators, heat registers, stoves, or other apparatuses that produce heat.
8. Water and Moisture
Do not expose this device to rain, moisture, dripping or splashing water. Do not use this amplifier near water (for example swimming pools and fountains). Do not place any objects containing liquids, such as bottles or glasses, on the top of the unit. Do not splash liquids on the unit. IP-20 equipment. There is no protec­tion against splashing water.
9. Ventilation
Slots and openings in the cabinet are provided for ventilation to ensure reliable operation of the amplifier and to protect it from overheating. These openings must not be blocked or covered. This amplifier should not be installed unless proper ventilation is provided or manufacturer’s instructions have been adhered to.
10. Interference of External Objects and/or Liquids with the Appliance
Never push objects of any kind into this amplifier through openings as they may touch dangerous voltage points or short-out parts that could result in fire or electric shock. Never spill liquid of any kind on the amplifier.
Page 6
6 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
IMPORTANT SAFETY INSTRUCTIONS
11. Connections
When you connect the amplifier to other equipment, turn off the power and unplug all of the equipment from the supply source. Failure to do so may cause an electric shock and serious personal injury. Read the user manual of the other equipment carefully and follow the instructions when making the connections.
12. Lightning
For additional protection of this amplifier during lightning storms or when it is left unattended and/or unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the amplifier due to lightning and power line surges. Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket or by external disconnecting all poles from the mains.
13. Damages that require service
Unplug this amplifier from the mains supply and refer to your dealer / distributor or other authorized repair workshop if any of the following situations occur:
> if liquid has been spilled or objects have fallen into the amplifier > if the amplifier has been exposed to rain or moisture > if the amplifier has been dropped or damaged in any other way > if the power supply cord or plug has been damaged > when the amplifier exhibits a distinct change from its normal function or
performance
> in case the amplifier has been used in a dusty environment for quite a
period of time
14. Servicing
All service and repair work must be carried out by a dealer / distributor author­ized by CAMCO. Do not attempt to service this amplifier yourself. As opening or removing covers may expose you to dangerous voltage or other hazards, the amplifier may only be opened by qualified personnel. Please refer to your dealer / distributor.
15. Spare parts
When spare parts are required, please ensure that the dealer / distributor only uses spare parts specified by the manufacturer. The use of un authorized spare parts may result in injury and / or damage through fire or electric shock or other electricity-related hazards.
16. Safety check
Upon completion of any service or repairs to this product, ask the dealer / dis­tributor to perform safety checks to determine that the amplifier works properly. Recommendations on how to carry out the safety test can be found in DIN VDE 0701-1 “Maintenance, Modification and Test of Electronic Appliances“.
17. Cleaning
Unplug this amplifier from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Clean only with dry cloth.
18. Packaging and shipping
When shipping the Q-POWER 14 amplifier, always use the original shipping carton and packing materials. For maximum protection repack the unit as it was originally packed at the factory.
19. Altitude (for China)
The amplifier shall only be operated at altitudes below or equal 2000 m.
Page 7
7 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
EXPLANATION OF SYSMBOLS
Explanation of Symbols
CAUTION – RISK OF ELECTRIC SHOCK – DO NOT OPEN.
WARNING – TO PREVENT FIRE OR SHOCK HAZARD, DO NOT
EXPOSE THIS AMPLIFIER TO RAIN OR MOISTURE.
CAUTION – HIGH VOLTAGE HAZARDS
EXIST WITHIN THIS PRODUCT.
REFER ALL SERVICING TO
AUTHORIZED PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALERTS
THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE OUTPUT
CONNECTORS! THAT COULD POTENTIALLY BE LIFE THREATENING.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL IS INTENDED TO
ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS
VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE.
THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER
TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE
LITERATURE ACCOMPANYING THE AMPLIFIER.
THE AMPLIFIER MAY ONLY BE CONNECTED
TO A SOCKET WITH A PROTECTIVE EARTH CONDUCTOR.
Page 8
8 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
EC DECLARATION OF CONFIRMITY
EC Declaration of Conformity
EC Declaration of Conformity in accordance to EC Directives:
Electromagnetic compatibility (Council Directive 2004/108/EC) Low-voltage electrical equipment (Council Directive 2006/95/EC)
Manufacturer´s Name:
CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen
Manufacturer´s Address:
Fischpicke 5, D-57482 Wenden, Germany
Declares that the product with the model name:
CAMCO Power amplifier Q-POWER 14
Conforms to the following standards:
> IEC / EN / UL / CSA 60065 > EN55103-1 Emission > EN55103-2 Immunity
The operating conditions and application environments presupposed in the information for use (user manual) are to be kept accordingly.
Wenden, 31.10.2014
Joachim Stöcker
Page 9
9 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
1
WELCOME!
1. Welcome to CAMCO
Thank you for choosing CAMCO products. You are now the proud owner of a very advanced CAMCO Amplifier. The technologies used in your amplifier are of the latest generation and designs delivering a far reaching set of results across all functions.
The amplifier has been designed to be incorporated into a professional speaker system and is suitable for use across all applications from Touring Live Sound to Fixed Installations.
Your speaker systems will benefit from the renowned CAMCO sonic quality as well as the many operating functions and features detailed within this manual which are incorporated within the design to maximise results.
The CAMCO peace of mind long term manufactures warranty is our commit­ment to you that every CAMCO amplifier is ready to give you many years of faultless service.
WELCOME TO CAMCO!
1.1 Unpacking
Please unpack and inspect your new amplifier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately. Only you the consignee may initiate a claim for shipping damage. CAMCO will be happy to cooperate fully as needed. Please save the shipping carton as evidence of damage for the shipper’s inspection.
Even if the amplifier has arrived in perfect condition, save all packing materials so you will have them if you ever need to transport the unit.
l
NOTE
Never ship the amplier without the original packing materials.
When shipping the Q-POWER 14 amplifier, always use the original shipping carton and packing materials. For maximum protection, repack the unit as it was originally packed at the factory.
Page 10
10 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
2
THE AMPLIFIER
2. The Amplifier
World’s first DSP controlled Power Supply in Professional Audio.
The all new Q-POWER 14 with DSP controlled PFC power supply is the flagship of the series, offering up to 14 000 W of undistorted power in an very compact and lightweight package.
The development of a DSP controlled, active PFC (Power Factor Correction) enables the Q-POWER 14 to use the mains power supply much more efficiently than conventional designs. The PFC provides solid supply voltage to the ampli­fier output stages, regardless of fluctuating or dropping mains voltages. The power supply can be configured to different mains circuit breaker char­acteristics and tripping currents through the USB connector on the rear. The Q-POWER 14 power supply’s DSP automatically choses the best regulating algorithms for highest power performance for any mains voltage range (100 V, 120 V and 230 V). Furthermore the Q-POWER 14 introduces the improved class D amplifier tech­nology already known from the Q-POWER 10, offering smooth and responsive handling with massive output power while maintaining CAMCO’s famous sonic integrity.
In addition to an improved signal to noise-ratio offering outstanding 118,5 dB (A-weighted), the impedance headroom has also been increased, meaning that the Q-POWER 14 is able to drive any kind of loudspeaker system even down to the lowest impedances. With the introduction of the Q-POWER SERIES CAMCO aim to deliver simple, pure and reliable power for applications where cost and ease of use are para­mount.
Power output @ operating mode
Q-POWER 14
3 520 W @ 3,2 Ω peak
3 250 W @ 2,7 Ω
3 030 W @ 3,2 Ω
2 900 W @ 2 Ω
2 520 W @ 4 Ω
1 380 W @ 8 Ω
715 W @ 16 Ω
Page 11
11 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
2
THE AMPLIFIER
2.1 The Q-POWER 14 Front
Clip-LEDs I-Out-LEDs Signal-LEDs On-LEDs Volume controls channel A to D Removable air filter system Cooling air inlet vents On/Off switch Optional volume control security cover
2.2 The Q-POWER 14 Rear
Rating plate (placed on the inside of the flap) AC power socket Cooling air outlet vents SPEAKON® output connectors channel A to D USB type B socket (for update and MCB programming only) Service socket (for factory use only) Gain selector Clip limiter switch for channel A/B and C/D XLR input connectors channel A to D Euroblock input connectors channel A to D
Page 12
12 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
3
MAINS SUPPLY
3. Mains
3.1 Mains Supply
The Q-POWER 14’s power supply is a true wide-range SMPS with active power factor correction (PFC). This means that it can be operated anywhere in the world without the need of any manual voltage range setting.
When mounting or connecting the amp always disconnect it from mains. Only connect the Q-POWER 14 amplifier to an appropriate AC circuit, according to the requirements indicated in the second line on the rating plate.
3.2 Mains Plugs and Cables
Only use mains cables with original Neutrik® powerCON® 32 A connectors for safety reasons.
l
NOTE
Please never unplug the powerCON® cable from the amplier while it is still carrying live voltage. Even if the amplier is switched off!
Unplugging must always be done on the other end of the mains cable (i.e. with the wall outlet plug*, or by the installation circuit breaker(s)). The reason ist that the powerCON® connector is not designed for disconnecting live voltages, as this might deteriorate it’s contact performance over time.
* provided the connector is suited as a disconnect device, as for example the “Schuko”
plug used in Europe or the Twist-Lock plugs used in North America
l
NOTE
Please make sure to always use appropriate mains cables and wall outlet plugs offering sufcient current rating.
à
See also chapter 3.7 for more details on current rating and circuit breaker selection.
And of course do never remove the protective earth conductor, under any cir­cumstances. The Q-POWER 14 must always be connected to a socket with a protective earth connector.
! WARNING
DO NEVER REMOVE OR DISCONNECT THE MAINS GROUND/EARTH CONNECTION. IT IS ILLEGAL AND DANGEROUS!
3.3 On / Off Switch
The On / Off Switch is a rocker-type switch. It is located on the right side of the front panel. To turn the amplifier on, press on the upper part of the switch. During power up the Clip- and Signal-LEDs of all channels will light up in red for a few seconds. To turn the amplifier off, press on the lower part of the switch.
Amplifier is switched on Amplifier is switched off
l
NOTE
This switch does NOT disconnect the amplier from mains.
Disconnecting the amplifier from the mains can only be achieved by disconnect­ing the mains plug or by the installation circuit breaker(s). The mains plug or circuit breaker(s) therefore have to be freely accessible at all times. Disconnect the mains plug from the mains during a thunderstorm or when the amplifier remains unused or unsupervised for a prolonged period of time.
While switched off and still connected to mains, the Q-POWER 14 will have an average power consumtion of less than 2 W.

   
  
 
Q-POWER 14
100 - 240 V ~ 50/60 Hz 2200 W
3000 W / 2,7 Ohm
Page 13
13 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
3
MAINS SUPPLY
3.4 Mains Voltage Range
To guarantee the best amplifier performance all over the world the power supply internally works with three mains voltage “grids” or “ranges”. These are:
> 100 VAC (Japan) > 110-127 VAC (North and parts of South America) > 200-240 VAC (Europe and the “Rest of the World”)
For each grid there is a set of highly optimised control parameters to get the maximum power performance achievable. The appropriate grid is automatically selected each time the amplifier is powered up. The grid selection is done solely inside the power supply’s DSP software, there are no electrical or electrome­chanical switches (e.g. relays) inside the power supply.
The selection of the three grids is based on the analysis of the mains voltage for approx. 1 second, and done on following thresholds:
Japan
(100 VAC)
America
(110 – 127 VAC)
ROW (Rest of the World)
(200 – 240 VAC)
ß 80 V 107 V à ß 107 V 140 V à ß 140 V 265 V à
l
NOTE
The power supply will not start below approx. 80 V and above approx. 265 V. Once running, it can handle mains voltages from 50 to 280 V.
Once the Q-POWER 14 is powered up the range will be kept even if the mains voltage varies in large borders, according to these thresholds:
Range Nominal voltage Operating range
Japan 100 V
AC
50 V – 180 V
America 110 – 127 V
AC
50 V – 180 V
ROW (Rest of the World) 200 – 240 V
AC
50 V – 280 V
This means that if the mains voltage rises higher than 180 V in either the Japan or the America range, the power supply will switch off shortly and restart in the ROW range (provided the mains voltage is stable and higher than 140 V).
On the other hand, if the Q-POWER 14 is once running in ROW range, the range is never changed anymore, until power loss or manual switch-off.
3.5 Inrush Current Limitation
The Q-POWER 14 has a special algorithm dedicated to limit the mains inrush current. This limiter will take action anytime the main SMPS is powered up. It will confine the mains current to a value smaller than 15 A
RMS
*.
* maximum rms value of inrush current over one half-cycle of the mains voltage according
to DIN EN 55103-1.
l
NOTE
When demanding very high output powers the mains current can reach levels up to 75 A (ROW range) or 106 A (America and Japan range) for very short periods of time. This could cause lamps to icker if connected to the same mains as the amplier.
Page 14
14 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
3
MAINS SUPPLY
3.6 Mains Power Consumption and Current Draw
Operating condition
Voltage Mains
current
Mains power consumption
Continuous
output power
2) 3)
Power
factor
Thermal dissipation
BTU/h Overall Efficiency
4)
Q-POWER 14
Amplifier standby (power off)
230 V 0,6 A
< 2 W 0 W ~ 0,00 < 2 W 6,8 n/a120 V 0,4 A
100 V 0,3 A
Idle (amplifier powered on)
230 V 0,9 A
130 W 0 W
0,61
130 W 443 n/a120 V 1,2 A 0,92
100 V 1,3 A 0,96
1/8th output power
1)
230 V
9,5 A 2 100 W
1 500 W
0,95 600 W 2 047 71 %
120 V
18,0 A 2 150 W 0,97 650 W 2 218 69 %
100 V
21,5 A 2 200 W 0,97 700 W 2 388 68 %
1/4th output power
2)
230 V
17,5 A 3 950 W
3 000 W
0,97 950 W 3 242 76 %
120 V
34,0 A 4 050 W 0,99 1 050 W 3 583 74 %
100 V
41,0 A 4 100 W 0,99 1 100 W 3 753 73 %
Full output power
3)
230 V
max. 75 A max. 15 400 W 13 000 W 0,99 2 300 W 7 848 85 %
120 V
max. 106 A max. 12 220 W 10 000 W 0,99 2 200 W 7 507 82 %
100 V
max. 106 A max. 10 100 W 8 000 W 0,99 2 100 W 7 165 79 %
1) Measured with pink noise @ 4 x 375 W / 2,7 Ω load (with crest factor of 12 dB to represent typical music signal).
2) Measured with 1 kHz continuous sine-wave @ 4 x 750 W / 2,7 Ω load. Duration limited by FuseProtect™ / MCB limiter and amplifier heating (thermal limiter).
3) Measured with 1 kHz sine-wave burst signal, @ 4 x 2,7 Ω load, THD <= 1%, min. 500 ms burst duration.
4) The overall efficiency is the ratio of the delivered output power to the mains power consumption. It indicates how much of the consumed mains input power is effectively delivered to the loudspeakers.
l
NOTE on mains current
The values given here are typical values only, measured on a standard outlet. The actual instantaneous mains current draw can vary depending on the music signal and the mains characteristics (especially the mains imped­ance) of any specic installation. But it will never be larger than the maxi­mum values at full output power indicated in the table.
Page 15
15 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
3
MAINS SUPPLY
3.7 FuseProtect™ Limiter - Mains Circuit Breaker selection
The integrated FuseProtect™ feature will at all times limit the mains current draw to the maximum current handling capabilities of the specific programmed MCB for each mains voltage range.
When shipped, the Q-POWER 14 is programmed with default MCBs for each mains voltage range. These are:
> 16 A C-type for the ROW range > 30 A for the America range > 30 A for the Japan range
The appropriate MCB is automatically loaded each time the Q-POWER 14 is powered up.
If needed for a specific installation, the user has the option to customise the MCB for each voltage range with the help of the
CAMCO USB MCB Updater
application. This application also allows to update the power supply’s firmware. Please check our website for latest updates.
à
See also chapter 6.3.
! WARNING!
For safety reasons, do never operate the Q-POWER 14 directly on larger breakers than 32 A. The powerCON® mains plug, the mains cable and the Q-POWER 14’s internal hardware is not designed for use on larger breakers (because of theoretically to small current carrying capacity in comparison to the installed MCB in case of an installation short-circuit). So do never “share” one large breaker (e.g. 50 A or 64 A) for two or more Q-POWER 14 ampliers.
Only in case the Q-POWER 14 is programmed with a MCB smaller or equal 16 A it is allowed to share a 32 A MCB for two or more amplifiers. But still we suggest to always use one breaker for each amplifier, as this also increases system robustness and selectivity in case of an installation problem.
If desired, the user has the option to select a MCB as high as 32 A even for the “ROW” mains voltage range, effectively doubling the long term input current capacity (compared to the default 16 A MCB).
l
NOTE
Please make sure to always use appropriate mains cables and plugs offer­ing sufcient current rating for the selected MCB. For instance it is not allowed to use the european 16 A “Schuko” plug when selecting larger breakers than 16 A. In this case the plug would be operated above it’s current specication and could get extremely hot, potentially creating iso­lation or re hazards.
Using larger MCBs in the ROW range will drastically raise the long-term output power capacity of the Q-POWER 14, especially when driving small loudspeaker impedances on all channels. This is because the FuseProtect™ limiter will only take action much later than with the default 16 A MCB, effectively offering higher output powers over a longer period of time (up to minutes or hours). But note that the max. achievable peak power is not affected by selecting a larger MCB. On the other hand, higher long-term output power will result in increased heating of the amplifier stages. So be aware that the amplifier module’s thermal limitation might occur more easily when running the Q-POWER 14 with continuous mains currents larger than approx. 20 A over longer periods of time. Thermal limitiation will result in reduced output level, possibly slight audio quality loss or even (in extreme situations) in short term amplifier module switch-off.
Please note that all MCBs always allow for much higher peak currents than their rated values before tripping. For example a 16 A breaker with C-type tripping characteristic will tolerate peak currents up to 80 A. The Q-POWER 14 FusePro­tect™ limiter will exaclty calculate the MCBs workload and always limit the actual mains current to values just below the tripping zone of the installed breaker. This offers maximum output power headroom for your show while at the same time protecting your electrical installation from being stressed beyond it’s limits.
Page 16
16 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
4
INSTALLATION
4. Mounting
Use four screws and washers when mounting the amplifier to the front rack rails. For mobile and touring use, the amplifier should also be secured using the 19” mounting elements on the rear panel.
4.1 Mounting Dimensions Q-POWER 14
4.2 Cooling
The air is taken in from the front and streams out through the back. It is essential that while the amplifier is running the air is able to circulate around it freely. The efficiency of the cooling will depend on the immediate environment (e.g. an enclosed rack, direct sunlight). If the amp is installed in a case or rack, please make sure the air outlet vents are not obstructed in any way, so that the hot air is able to stream out freely.
4.3 Fans
The fans mounted in the Q-POWER 14 operate permanently, but as long as the temperature remains below 40 °C they run at their slowest speed and can hardly be heard. The highest detected temperature from either the amplifier stages or the power supply controls the speed of the fans: above 40 °C the speed is increased until it reaches its maximum value.
Page 17
17 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
5
CONNECTORS
5. Input and Output Connectors
5.1 Analogue Input Connectors
XLR Pin 1 ground
Pin 2 hot (in phase, +)
Pin 3 cold (out phase, –)
Euroblock Pin 1 hot (in phase, +)
Pin 2 ground
Pin 3 cold (out phase, –)
Make sure to always use high-quality symmetrical (balanced) shielded cable to ensure maximum audio quality.
Please do not simultaneously attach two independent signal sources to the XLR and Euroblock input connectors of the same channel. This could lead to volume and audio quality loss and could damage the connected signal sources.
Input B Input A
In C In A
231231 231231
In BIn D
Input CInput D
+-
+-+-+-
Input B Input A
In C In A
1 321 32 1 321 32
In BIn D
Input CInput D
+ - + - + - + -
Page 18
18 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
5
CONNECTORS
5.2 SPEAKON® Loudspeaker Output Connectors
The four SPEAKON® connectors are connected to the channel A to D power amplifier outputs. The pin configuration of the connectors is:
SPEAKON® output 2 (View from the back)
SPEAKON® output 1 (View from the back)
Pin 1 + Channel C Output + Pin 1 + Channel A Output +
Pin 1 – Channel C Output – Pin 1 – Channel A Output –
Pin 2 + Channel D Output + Pin 2 + Channel B Output +
Pin 2 – Channel D Output – Pin 2 – Channel B Output –
SPEAKON® output 4 (View from the back)
SPEAKON® output 3 (View from the back)
Pin 1 + Channel D Output + Pin 1 + Channel B Output +
Pin 1 – Channel D Output – Pin 1 – Channel B Output –
Pin 2 + Channel C Output + Pin 2 + Channel A Output +
Pin 2 – Channel C Output – Pin 2 – Channel A Output –
l
NOTE / IMPORTANT
The Q-POWER 14 uses a bridged power amplier output stage. This implies that the “Output –” loudspeaker outputs are not (and must never be) directly connected to the electrical ground (earth) or chassis of the amplier! Please make sure to always attach the loudspeakers between the “Output +” and the “Output –” outputs of the same channel.
! WARNING!
SPEAKON® connectors marked with the lightning ash indicate high vol­tages that are potentially life threatening.
Wiring to these terminals requires installation by an instructed person or the use of ready-made leads or cords. Custom wiring must only be made by qualified personnel.
To prevent electric shock, do not operate the amplifier with damaged loud­speaker cables (i.e. if the isolations are damaged or if the internal wires are exposed).
Wiring to the output connectors must conform to NEC Class 2 safety standards or its equivalent that meets all national and local electric codes.
l
NOTE
For reasons of safety and performance, use only high-quality fully in su­lated speaker cables of stranded copper wire.
Use the largest wire size that is economically and physically practical, and make sure the cables are no longer than necessary.
The Q-POWER 14 amplifiers can handle any loudspeaker impedance down to 2 Ω. Lower impedances are still safe, but will result in less efficiency, increased heat­ing of the amplifier stages and possibly noticeable loss in audio quality. Imped­ances lower than approximately 0,6 Ω (ideal resistive load) can lead to short term shutdown of the corresponding amplifier module. Once the underimpedance situation is gone, the amplifier module will resume normal operation.
Page 19
19 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
6
OPERATION
6. Operation
6.1 Indicators
6.1.1 ON LEDs
Under normal operation, after the amp has started, all four green ON LEDs are permanently lit.
6.1.2 SIGNAL/Protect LEDs (multifunctional)
The green Signal LEDs are illuminated when the voltage level at the output reaches approx. 4 V; this corresponds to a power of approx. 4 W into a 4Ω load. The channel signal LEDs are illuminated red when the amplifier is in Protect Mode (Mute), for example because of persistent DC-voltage at the outputs or overheating.
6.1.3 I-OUT Output Current LEDs
The brightness is proportional to the output current in the corresponding chan­nel.
6.1.4 CLIP LEDs (multifunctional)
The colour of the bi-coloured LED changes between orange and red, depending on the clip intensity. Orange indicates light clipping, red indicates heavy clipping.
6.2 Controls
6.2.1 Volume Control
A volume control with 41 notched settings controls the audio signal. These settings have been selected to correspond to human hearing characteristics (logarithmically) and therefore guarantee an optimal range of settings for practical applications. Each channel can be set individually.
Set the volume to zero before turning the amplifier on to prevent the occurrence of sudden high volume levels which may cause damage to your hearing and the speakers.
6.2.2 Gain Selector
A switch on the rear of the Q-POWER 14 amplifier allows to select the overall amplifier gain.
The Q-POWER 14 amplifier has a 26 dB and 32 dB voltage gain setting along with a 1,4 V sensitivity setting.
6.2.3 Clip Limiter Switch
This switch is located at the rear of the Q-POWER 14 amplifier. It allows you to activate the clip limiter function on the channels A/B and C/D respectively.
Page 20
20 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
6
OPERATION
6.3 CAMCO USB MCB Updater
The
CAMCO USB MCB Updater
offers a set of different commonly used mains breakers, and allows to permanently store it inside the amplifier. The stored MCBs will be maintained even after power loss. The application also can display a graph showing in detail each MCBs tripping characteristic.
In case you do not find the appropriate (or any similar) breaker in the list of cur­rently supported MCBs, please contact CAMCO for adding those MCBs to the set. For adding, we would need the brand name, type name or number and, if available, a datasheet showing the tripping characteristic graph.
But note that the highest continuous current of any MCB will always be limited 32 A max., even in the two lower mains voltage ranges. No larger MCB can be selected and will be offered in the future, due to internal hardware limitations.
l
NOTE
When connecting the Q-POWER 14 to your host computer with the USB cable, the amplier will shut down completely and all LEDs will be switched off. This behaviour is normal. The amplier will restart automatically once the USB cable is removed.
Page 21
21 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
7
PROTECTIONS
7. Protections
7.1 Power Amp Protection Systems
7.1.1 Clip Limiter
If the maximum output level is higher than the amplifier can deliver, the Clip Lim­iter (if active) will reduce the output signal in order to limit distortion. The Clip Limiter works on each channel independently, but can only be activated for the channel pairs A/B or C/D respectively. The Clip LED sensitivity on the display is designed to be very responsive and accurate. This means that you will still see the Clip LEDs light up, even if the clip limiter is working correctly. This allowes the user still to assess if there is real clip, even if the clip limiter does prohibit audible distortion. The remaining (and indicated) clip is then very small and usually low enough to be audibly perceive as “clean” or undistorted signal, compared to a disabled clip limiter.
7.1.2 SOA Protection
Whenever the power transistors leave their Safe Operation Area (SOA), the SOA-protection will limit the maximum output current in an extremely fast way, to effectively protect the semiconductors from any damage. This protection will usually only take place at loudspeaker impedances equal or lower 2 Ω. Audio quality might be deteriorated when this limiter takes action.
7.1.3 DC Protection
Each output of the power amp is constantly monitored for persistent DC voltage levels. If the approx. 5 V thresholds are exceeded at any of the outputs, the cor­responding channel will be muted. If DC was only detected for a short moment, the amplifier will release mute and resume operation. If DC is detected for longer periods or repeatedly, the amplifier will switch to standby mode and disable the main power supply.
7.1.4 DC Servo
To prevent DC offset at the speaker output the Q-POWER 14 amplifier is fitted with a DC Servo (hence there are no capacitors in the signal path!).
7.1.5 Output Current Limiter
The output current to the loudspeakers is permanently controlled in the output stage. In case of exessive loading the maximum output current of the amplifiers is automatically limited. This improves reliability without degrading sound quality when driving complex loads.
7.1.6 Underimpedance Limiter
In case the SOA protection is triggered repeatedly, each amplifier module will clip it’s maximum output level until SOA protection is not reached anymore. This usually only takes place at loudspeaker impedances equal or lower approx. 2 Ω. This limitation is done through pure clipping of the output voltage, so it will result in audible distortion in case the Clip Limiter is not activated.
7.1.7 Output Short Circuit Protection
In case the attached loudspeaker impedance gets lower than approx. 0,6 Ω (e.g. in case of any short-circuit inside the loudspeaker or the cabling) each amplifier module will switch off completely for 3 seconds to protect internal elec­tronics. After 3 seconds, the module will try to resume operation (... and possibly again trigger the circuit protection in case the short circuit is still present).
l
Note
This protection only works for mid to high output levels. Low output levels will not be enough to trigger the short circuit protection, even if the short is well below 0,6 Ω. At low output levels, the amplier will only carry out SOA, output current, underimpedance and possibly thermal limitation but will continue to deliver music.
7.1.8 Thermal Limitation and Protection
There are sensors in each amplifier heatsink in order to ascertain it’s tempera­ture. If a temperature of more than 85 °C is detected at the heatsinks, the input signal on that channel is reduced proportionally to prevent further heating of the amplifier. If the temperature exceeds approximately 95 °C, the corresponding channel is muted completely.
Page 22
22 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
7
PROTECTIONS
7.1.9 High Frequency Protection
All outputs are permanently monitored for high-frequency high output signals. Continous output of 22 kHz sine-wave signals at full scale is permissible, but higher frequencies at very high output levels might trigger this protection. If detected, the corresponding amplifier module will be switched off for a few seconds and restarted again.
7.2 Mains and Power Supply Protections
7.2.1 Inrush Current Limitation
Within 7 seconds of the amplifier being switched on, the inrush current limiter will increase mains current from nearly zero to nominal value. This value depends on program material, output level and speaker loads.
7.2.2 Mains Overvoltage Detection
Mains over voltage detection is always operative. When the mains voltage exceeds approx. 280 V (ROW range) or 180 V (America and Japan range), the amplifier will be switched off. The system will try to restart in intervals and will return with a soft start when the regular mains voltage returns.
7.2.3 Mains Surge Overvoltage Protection
The Q-POWER 14 is fitted with a varistor unit, protecting the SMPS from sporadic surge overvoltages coming from the mains distribution.
7.2.4 Mains Failure Detection
Mains failure detection is always operative. When the mains supply is interrupted for more than 5 mains cycles, the amplifier will be switched off. Shorter or equal dropouts will be ignored and the amplifier will continue to deliver music out of the amplifier’s internal capacitors (acting as enrergy reservoir). With this feature it’s possible to continue to deliver music at 1/8th output power during mains dropouts as long as 100 ms! In case the amplifier has been switched off it will return with a soft start when the regular mains voltage returns.
7.2.5 Mains Overcurrent Limiter
The mains input current is continously monitored and will be limied to maximum values of 75 A
RMS
/ 106 A
Peak
(in ROW range) or 106 A
RMS
/ 150 A
Peak
(in America
and Japan range).
7.2.6 Over Current Protection
All internal SMPS currents are continuously monitored. If an overcurrent situation occurs, the main SMPS immediately stops working. Should there be an internal failure, this feature prevents other parts from being damaged.
7.2.7 Fuse / MCB Protection (FuseProtect™ Limiter)
When driving the Q-POWER 14 at very high output levels over a longer period of time (i.e. several seconds and minutes) the average mains current draw can become very high. In such situations, the FuseProtect™ limiter will reduce the output signal in order to prevent the external mains breaker from tripping. On the other hand, this limiter will not affect the output level for dynamic music signals, thus still guaranteeing the full available peak output power. Please note that the FuseProtect™ limiter only controls the average mains input current, not the short term peak input current. This means that with very dynamic music signals the (short term) input current can still reach very high levels, which can be very demanding for a mains distribution.
à
See also chapter 3.7
7.2.8 Thermal Protection
The temperatures of all power supply heatsinks and main transformers are per­manently monitored. In case of excessive heating due to an internal failure the main SMPS will switch off immediately to avoid any further damage.
Page 23
23 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
8
FILTER CLEANING
8. Filter Cleaning
8.1 Removing the Filter System and Cleaning
The air intake on the front of your Q-POWER 14 amplifier is fitted with a removable filter system. If the filter becomes clogged, the unit will not cool as efficiently as it should and may lead to reduced output levels.
Q-POWER 14 Filter Assembly
Foam filter Front frame Screw
! WARNING!
Turn off and disconnect the amplier from the mains before removing the front frame.
To clean or replace the filter just slightly unscrew the fixing screw with the help of a 3 mm hex key. The screw will be held back by a small plastic spacer on the back of the frame to avoid losing it. Then shift the front frame slightly to the right. Then you should be able to remove the frame from the amplifier completely (pull gently to avoid any bending of the front frame).
Page 24
24 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
9
VOLUME CONTROL SECURITY COVER
9. Volume Control Security Cover
9.1 Mounting the Volume Control Security Cover
It is possible to install a solid protection over the volume controls to prevent intentional or unintentional changes of the amplifier volume settings.
! WARNING!
Disconnect the amplier from the mains before installing the cover.
In the original state the holes needed to fix the security cover on both sides of the volume knobs are hidden behind the plastic front label. In case you wish to install the cover please first pierce two holes in the front label to facilitate the screwing, as shown in the drawings.
To find the exact positions of the holes take the included jig you will find attached on the last page of this manual and place it on top of the volume knobs. The positions of the hidden screw holes are indicated on the template. Then firmly pierce and turn with a pointed tool (we recommend a Phillips PH1 recessed head screwdriver) through the jig and the label at these positions to obtain a clean hole. You now should see the metal of the threaded bush behind the label.
Then remove the jig and fix the cover with the two included M3 recessed threaded screws.
l
NOTE
Do not use any pointed tools (e.g. screwdriver) with a diameter of less than 3,5 mm (0,138 in), as they might be stucked too deeply inside the screw holes and damage internal components.
Page 25
25 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
10
TROUBLESHOOTING
10. Troubleshooting
Here are some tips and tricks which might be useful when encountering weird amplifier behaviour during use. If none of the advices work please contact CAMCO for further support.
10.1 No reaction when switching the amplier on
If nothing happens when switching the amplifier on (i.e. all LEDs stay totally dark), please check following points:
> Check the mains cable and plug. > Confirm that the AC outlet works by plugging in any other device. > Check if the amplifier is connected to a computer through USB cable.
In update or MCB edit mode all LEDs are off and the power supply is
powered down.
10.2 All four signal LEDs are red, the green On-LEDs are off
During startup you will see this LED pattern for approx. 5 seconds. This is com­pletely normal. But if this LED pattern persists, it can have different reasons:
a) Mains supply bad, lost or disconnected.
> Check the mains cable and plug. > Confirm that the AC outlet works by plugging in any other device.
b) One or more amplifer stages have switched to permanent protect mode, because of continuous DC on the loudspeaker outputs or extreme overtem­perature.
> Try to switch the amplifier off and on again.
> If this doesn’t help unplug the mains cable and wait for at least 2 minutes,
then replug the mains cable and switch the amplifier on.
> If the amplifier is very hot switch it off, let it cool down for several minutes
and then try to switch in on again.
10.3 All green On-LEDs are on, but there is no sound
If no sound can be heard on the outputs please check following points:
> Are the volume controls set to minimum? > Check if the sound source is delivering a signal. > Check the speaker cabling for bad or open contacts.
10.4 Sound is distorted
> Turn on the Clip Limiter. > Reduce the input level. > Check the attached loudspeaker impedance and cabling.
Impedances lower than 2 Ω will cause the underimpedance limiter to take action (depending on signal level and amplifier temperature). This limi­tation will be audible as distortion if the Clip Limiter is not activated.
10.5 Sound is distorted although Clip Limiter is On
> Check input signal level and attached loudspeaker impedance/cabling.
The internal limiter can only reduce the audio level up to approx. 12 dB. If the input signal is driving the amplifier even further into clip the Clip Limiter will not be able anymore to keep the output signal “clean” resulting in more audible distortion.
Example: With a 2 Ω load the amplifier stage would begin to clip at approx 7,8 dBu (1,90 V
RMS
) @ 32 dB amp gain in single channel operation. If the
input signal level now is higher than 19,8 dBu (7,57 V
RMS
), the internal limiter is saturated and will not be able to keep the output signal “clean” anymore. So please take care not to overdrive the amplifier’s inputs and to match the input signal level to the attached impedances.
Page 26
26 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
10
TROUBLESHOOTING
10.6 Signal and Clip LED of one or more channels are red intermittently
This LED pattern indicates that the corresponding amplifier channel has gone to short-term protect mode. This can have multiple reasons:
a) Short-circuit protection has been triggered (3 sec. protect duration).
> Check the loudspeakers and cables for possible short-circuits.
b) Overtemperature protection has been triggered (undefined protect duration, depending on temperature rise and fall).
> Reduce output volume and/or loudspeaker load.
c) DC protection has been triggered (0,5 sec. protect duration).
> Check the input signal quality and level. > Reduce the input signal’s very low frequency (subsonic) signal compo-
nents.
Very low frequency components with asymmetric shape (for example when heavily distorted) might trigger the amplifiers DC detection. Be aware that the amplifier is technically DC coupled (except for the DC servo), so it will try to amplify anything which is fed to it’s inputs, even if it is only a few Hz and regardless of it’s shape and distortion.
d) HF (High Frequency) protection has been triggered (2,5 sec. protect duration).
> Check input signal for HF components.
10.7 Output power lower than usual
> Check the selected/programmed MCB
The selected MCB can have noticeable influence on overall output power of the amplifier. Especially smaller MCBs < 16 A usually will also reduce the maximum output power of the amplifier.
> Check the mains distribution
Very weak mains distributions or generators may cause the mains volt-
age to drop considerably when heavily loaded by the amplifier. Although the amplifier continues to deliver music, the output power will be reduced to compensate for the lack of mains input power.
10.8 The amplier gets hot very quickly
> Check the attached loudspeaker impedance and cabling.
Low loudspeaker impedances < 2 Ω will cause faster heating of the
amplifier stages.
> Check if the selected/programmed MCB is larger than 20 A for the ROW
range.
If such a large breaker is selected for the ROW range, the amplifier will be able to deliver more continuous long-term output power (not peak). This in turn will also result in higher amplifier module temperature rise, as now the long-term output power will not anymore be limited intrinsically by the mains input current limitation. In this operation condition it is pos­sible to drive the amplifier stages into thermal limitation or even thermal shutdown. This behaviour is normal and must be taken into account when operating the amplifier with such large MCBs in the ROW range.
10.9 The CAMCO USB MCB Updater application does not connect to the amplier
> Check if the USB cable is properly connected and inserted. > Check if the amplifier is connected to mains. > Eventually try to reconnect in the “USB” à “Connect...” menu and chose
the USB device manually.
> Unplug and replug the USB cable and wait a few seconds for your oper-
ating system to detect the hardware, if necessary also close and restart the application.
Page 27
27 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
11
SPECIFICATIONS
11. Specifications
Q-POWER 14
Output power
1 kHz, THD ≤ 1%, all channels driven
duration limited by fuse and thermal protection
16 Ω
8 Ω
4 Ω 3,2 Ω 2,7 Ω
2 Ω
230 V (ROW)
4 × 715 W 4 × 1 380 W 4 × 2 520 W 4 × 3 030 W 4 × 3 250 W 4 × 2 900 W
120 V (America)
4 × 690 W 4 × 1 300 W 4 × 2 290 W 4 × 2 670 W 4 × 2 850 W 4 × 2 900 W
100 V (Japan)
4 × 680 W 4 × 1 260 W 4 × 2 170 W 4 × 2 490 W 4 × 2 630 W 4 × 2 720 W
Peak output power
1 kHz, single sine wave, all channels driven
16 Ω
8 Ω
4 Ω 3,2 Ω 2,7 Ω
2 Ω
All ranges (ROW, America and Japan)
4 × 770 W
4 × 1 530 W
4 × 2 990 W
4 × 3 520 W 4 × 3 270 W 4 × 2 900 W
70 / 100 V line operation output power
1 kHz, THD ≤ 1%, all channels driven
* limited by output current limitation
70 V
100 V
230 V (ROW) 4 × 2 670 W*
4 × 3 070 W
120 V (America)
4 × 2 670 W*
4 × 2 150 W
100 V (Japan)
4 × 2 670 W*
4 × 1 600 W
Circuitry MOSFET, Class D high effiency circuit
Signal to noise-ratio
20 Hz – 20 kHz, 8 Ω load, 26 dB amplifier gain
> 115 dB (unweighted)
> 118,5 dB (A-weighted)
Maximum output voltage ± 157 V
Peak
Maximum output current
may be subjected to component tolerances
± 52 A
Peak
All power data are typical values.
We reserve the right to make technical alterations without prior notice.
Page 28
28 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
11
SPECIFICATIONS
Q-POWER 14
Frequency response
@ 4 Ω load with 120 W ouptut power
10 Hz – 20 kHz: ± 0,1 dB
THD+N over frequency
@ 4 Ω load with 120 W output power
20 Hz – 8 kHz: < 0,1 %
Damping factor
8 Ω load, 1,7 kHz and below
400
Input impedance 15 kΩ balanced
Amplier gain Selectable: 26 dB, 32 dB, or 1,4 V input sensitivity
Maximum analogue differential input level +22 dBu / 9,75 V
RMS
/ 13,8 V
Peak
Level attenuation Individual volume control knobs for each channel
Minimum loudspeaker load impedance Zmin = 2 Ω
Lower values are safe, but out of specification. No performance guarantees
can be given when driving lower impedances than specified.
Protection circuits SMPS: Mains Overvoltage Detection, Mains Surge Overvoltage Protection, Mains Failure Detection,
Overcurrent Protection, Thermal Protection
Amplifier: Temperature Dependent SOA Protection, DC Protection, Thermal Protection, Short Circuit Protection,
High Frequency Protection
Limiters SMPS: Mains Inrush-Current Limitation, FuseProtect™ Limiter (with selectalbe MCB),
Mains Overcurrent Limitation
Amplifier: Clip Limiter (individually selectable for channels A+B and C+D),
Underimpedance Limiter, Output Current Limiter, Thermal Limiter
Cooling Three speed-controlled axial fans (temperature dependent)
LED indicators LEDs for ON, SIGNAL/Protect (multifunctional), I-OUT output current,
and CLIP (multifunctional) for each channel
Input connectors Four 3-pin XLR connectors,
Four 3-pin Euroblock connectors
Output connectors Four 4-pole SPEAKON® connectors for each output channel (bi-amping possible for channels A/B and C/D)
Update and Service connectors One USB Type B connector for firmware update and MCB selection/programming,
One 10-pole header connector (for service only)
We reserve the right to make technical alterations without prior notice.
Page 29
29 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
11
SPECIFICATIONS
Q-POWER 14
AC mains supply 100 - 240 VAC, 50/60 Hz
AC mains connector Neutrik® 32 A powerCON® connector
AC mains startup range
Mains voltage range for initial startup of power supply
80 V - 265 V
AC mains operating range
Maximum amplifier output power performance will decrease when operating the amplifier
at mains voltages smaller than -10 to -20 % of the rated voltage.
à
See also chapter 3.4
Japan: 50 V - 180 V America: 50 V - 180 V ROW: 50 V - 280 V
AC mains power consumption
* Measured with pink noise @ 4 x 375 W / 2,7 Ω load.
à
See also chapter 3.6
Amplifier standby (power off): < 2 W Idle (Amp powered on): 130 W 1/8th output power*: 2200 W
Operating temperature
Non-condensing
+5 °C to +55 °C / +41 °F to +131 °F
Dimensions (W × H × D) 483 × 88,1 × 452 mm /
19 × 3,5 × 17,8 inches
(19”, 2U)
Net weight 13,8 kg / 30,4 lbs
Shipping dimensions (W × H × D) 610 × 133 × 540 mm /
24 × 5,2 × 21,3 inches
Shipping weight 17 kg / 37,5 lbs
We reserve the right to make technical alterations without prior notice.
Page 30
30 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
12
TYPICAL PERFOMANCE DIAGRAMS
12. Typical Performance Diagrams
12.1 Gain vs. frequency, 120 W output power
(Measurement of a typical performance; 8 Ω / 4 Ω / 2,7 Ω )
12.2 Phase vs. frequency
(Measurement of a typical performance)
12.3 THD @ 1 kHz vs. input level
32 dB amplifier gain (Measurement of a typical performance; 8 Ω / 4 Ω / 2,7 Ω )
12.4 THD vs. frequency, 120 W output power
(Measurement of a typical performance; 8 Ω / 4 Ω / 2,7 Ω )
10 100 1k 10k
1
0,5
0
− 0,5
− 1
− 1,5
− 2
− 2,5
− 3
− 3,5
− 4 50k
Hz
dBr
180
150
120
90
60
30
0
− 30
− 60
− 90
− 120
− 150
− 180
10 100 1k 10k 100k
Hz
deg (°)
1
0,1
0,01
0,001
− 60 − 50 − 40 − 30 − 20 − 10 0 10
dBu
%
1
0,1
0,01
0,001
20 100 1k 20k
Hz
%
10k
Page 31
31 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
12
TYPICAL PERFORMANCE DIAGRAMS
12.5 Channel separation vs. frequency @ 3 × 120 W / 4 Ω
Only the measured channel has no signal, all other channels are loaded (Measurement of a typical performance; Ch 1 / Ch 2 / Ch 3 / Ch 4 )
12.6 DIM100 vs. input level @ 4 Ω load
32 dB amplifier gain (Measurement of a typical performance)
12.7 Common mode rejection ratio vs. frequency
(Measurement of a typical performance)
12.8 FFT of noise level vs. frequency
No input signal applied, analog input, 32 dB amplifier gain (Measurement of a typical performance)
0
− 20
− 40
− 60
− 80
− 100
− 120
− 140 10 100 1k 10k
Hz
dBr
20k
10
1
0,1
0,01
0,001
− 60 − 50 − 40 − 30 − 20 − 10 0 10
dBu
%
0
− 10
− 20
− 30
− 40
− 50
− 60
− 70
− 80
− 90
− 100 10 100 1k 10k 20k
Hz
dBr
100
10
1
100 m
10 m
1 m
100 µ
10 µ
1 µ
10 100 1k 10k
Hz
V
50k
Page 32
32 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
12
TYPICAL PERFORMANCE DIAGRAMS
12.9 Output impedance vs. frequency
@ 1 A output current (Measurement of a typical performance)
12.10 Damping factor vs. frequency
Referenced to 8 Ω @ 1 A output current (Measurement of a typical performance)
1
0,1
0,01
10 100 1k 10k
Hz
Ω
20k
10 100 1k 10k
600
500
400
300
200
100
0
Hz
damping factor
20k
Page 33
33 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
13
UNIT CONVERTION EQUATIONS
13. Unit Conversion Equations and Lookup Table
13.1 Unit Conversion Equations
Unit conversion Equation
V
RMS
à dBu
V
RMS
à dBV
dBu à V
RMS
dBV à V
RMS
V
RMS
à V
Peak
V
RMS
à Output power
8 Ω4 Ω2,7 Ω2 Ω
13.2 Lookup Table
V
RMSVPeak
dBu dBV Output power
in W / 8 Ω in W / 4 Ω in W / 2,7 Ω in W / 2 Ω
1 1,41 2,22 0,00 0,13 0,25 0,37 0,50
2 2,83 8,24 6,02 0,50 1,00 1,48 2,00
3 4,24 11,76 9,54 1,13 2,25 3,33 4,50
4 5,66 14,26 12,04 2,00 4,00 5,93 8,00
5 7,07 16,20 13,98 3,13 6,25 9,26 13
6 8,49 17,78 15,56 4,50 9,00 13 18
7 9,90 19,12 16,90 6,13 12 18 25
8 11,31 20,28 18,06 8,00 16 24 32
9 12,73 21,30 19,08 10 20 30 41
10 14,14 22,22 20,00 13 25 37 50
12 16,97 23,80 21,58 18 36 53 72
15 21,21 25,74 23,52 28 56 83 113
20 28,28 28,24 26,02 50 100 148 200
30 42,43 31,76 29,54 113 225 333 450
40 56,57 34,26 32,04 200 400 593 800
50 70,71 36,20 33,98 313 625 926 1 250
60 84,85 37,78 35,56 450 900 1 333 1 800
70 98,99 39,12 36,90 613 1 225 1 815 2 450
80 113,14 40,28 38,06 800 1 600 2 370 3 200
90 127,28 41,30 39,08 1 013 2025 3 000 4 050
100 141,42 42,22 40,00 1250 2 500 3 704 5 000
125 176,78 44,16 41,94 1953 3 906 5 787 7 813
150 212,13 45,74 43,52 2813 5 625 8 333 11 250
175 247,49 47,08 44,86 3828 7 656 11 343 15 313
200 282,84 48,24 46,02 5000 10 000 14 815 20 000
Values in grey are calculated only. The
Q-POWER 14
is not able to deliver these output powers.
Page 34
34 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
14
WARRANTY
14. Warranty Information
14.1 Summary of Warranty
CAMCO guarantees the Q-POWER 14 amplifier to be free from defective mate- rial and / or workmanship for a period of six (6) years from the date of sale. When a defect occurs under normal installation and use, CAMCO will repair the product under this warranty. In this event, please return the amplifier to your dealer / distributor together with a copy of your sales receipt as proof of pur­chase.
This warranty provides that examination of the returned product must indicate in our judgment a manufacturing defect.
14.2 Items Excluded from This Warranty
CAMCO is not liable for any damage caused by shipping accidents, misuse, abuse, operation with incorrect AC voltage, operation with faulty peripheral equipment, modification or alteration without prior factory approval, service by an unauthorised service center and normal wear and tear. Amplifiers on which the serial number has been removed or defaced are not eligible for warranty service.
14.3 What CAMCO Will Do
CAMCO (or its appointed agent) undertakes to rectify any defect regardless of
the reason for failure (unless excluded from this warrenty), by repair, replacement or refund as it sees fit.
14.4 How to Obtain Warranty Service
You must notify your dealer / distributor of your need for warranty service. All components must be shipped in the original packaging.
14.5 CAMCO Product Improvement
CAMCO reserves the right to improve the technical standard of its products
without giving prior notice. If in any doubt, please consult your dealer / distri butor or contact CAMCO directly for clarification.
Page 35
35 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
15
SERVICE INFORMATION
15. Service Information
Owner’s Information
Company Name:
Contact:
Address:
Telephone:
Facsimile:
E-Mail Address:
Model:
Serial Number:
Purchase Date:
Expired Warranty
If the warranty has expired, payment will be:
Cash / Cheque VISA MasterCard
Shipping Address
To transport the amplifier, the original packing materials must be used. Please return the amplifier to the address on the right side or your nearest CAMCO appointed distributor.
Nature of problem occurred
Please describe the conditions that existed when the problem occured and what attempts were made to correct it:
Other equipment in your system:
Our web site: www.camcoaudio.com provides a complete list of CAMCO dealers / distributors.
CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen, Fischpicke 5, 57482 Wenden, Germany
PLEASE ENCLOSE THIS COMPLETED FORM WITH THE AMPLIFIER
DO NOT SEND SEPARATELY
Page 36
36 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
16 / 17
MAINTAINCE INFORMATION / DECOMMISSIONING
16. Maintenance Information
Cleaning and servicing the inside of the amplifier must never be carried out by unqualified personnel. The amplifier must never be opened by unqualified personnel.
Cleaning and servicing work on the inside of the amplifier must only be carried out by qualified personnel.
Qualified personnel is defined as a person who has gained specialised relevant knowledge of electronic engineering through education, training, and experi­ence, and who has sufficient knowledge of all relevant governmental work safety regulations to be in a position to judge the safe functioning of power amplifiers based on technical rules according to IEC 60065 (IEC 60065 (DIN EN 60065) “Safety Requirements for Audio, Video or simlar Electronic Appliances”).
In order to guarantee the safe functioning of the amplifier, it has to be checked regularly, depending on its application but at least once a year, by a properly qualified person. Advice on how to carry out these checks can be found in DIN VDE 0702-1 “Safety Checks for Electronic Appliances”.
An amplifier that is considered to be unsafe must be labelled accordingly and stored in a safe place to prevent this amplifier being used mistakenly.
17. Decommissioning
During the decommissioning process of the amplifier, all legally prescribed rules and procedures must be adhered to.
Page 37
37 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
COMPANY INFORMATION
Company information
Mailing address:
CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany
Telephone:
+49 (0) 27 62 / 4 08-0
Facsimile:
+49 (0) 27 62 / 4 08-10
Internet:
www.camcoaudio.com
E-Mail:
postmaster@camcoaudio.com
Page 38
38 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
CHANGES MADE TO THE AMPLIFIER / NOTICES
Changes Made to The Amplifier / Notices
l
NOTE / IMPORTANT
Please consider that any changes made to the amplifier have to be documen­tated in writing and passed on to the buyer in the event of resale!
Page 39
39 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
CHANGES MADE TO THE AMPLIFIER / NOTICES
Page 40
40 / 42
www.camcoaudio.com
Q-POWER 14 | POWER AMPLIFIER
SECURITY COVER TEMPLATE
Hole template for Volume Control Security Cover
Scale 1:1 for printing.
Page 41
Page 42
MADE IN GERMANY
www.camcoaudio.com
Q-POWER 14
POWER AMPLIFIER
Q
Loading...