The amplifier may only be used in accordance with the information pro­vided in the user manual. Before and during the usage of the amplifier please ensure that all recommendations, especially the safety recommen­dations as detailed in the user manual, are adhered to.
The iD4 amplifier is designed for the amplification of pulsed audio sig­nals. The amplifier should only be connected to speakers with an average impedance as indicated.
2. User Manual
Read the information for use (user manual) and heed all warnings. Keep this user manual in a safe place during the lifetime of the amplifier. The user manual forms an integral part of the amplifier. Reselling the amplifier is only possible if the user manual is available. In case of reselling the amplifier, the reseller has to document any changes made to the amplifier in writing and pass the documentation on to the buyer.
3. Environments
Use this amplifier only in E1, E2, E3, or E4 environments according to EN55103-2 “Electromagnetic compatibility – Product family standard for audio, video, and audio-visual and entertainment lighting control appara­tus for professional use – Part 2: Immunity”.
4. Mounting / Placement
Do not place this amplifier on an unstable cart, stand,
IMPORTANT SAFETY INSTRUCTIONS
tripod, bracket, or table. The amplifier may fall caus­ing serious injury and serious damage to the prod­uct. Any mounting of the amplifier should follow the manufacturer´s instructions. Only mounting acces­sory shall be used which is recommended by the manufacturer.
i-SERIES
advancEd amplIfIERS
5. Power Cord Protection
Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon them or against them, paying particular attention to cords and plugs and the point where they exit from the amplifier. The disconnection device from mains (mains plug or external all-pole circuit breaker) shall remain readily operable and freely accessible at all times.
6. Heat
Do not use this amplifier near any heat sources such as radiators, heat registers, stoves, or other apparatuses that produce heat.
7. Water and Moisture
Do not expose this device to rain or moisture. Do not use this amplifier near water (for example swimming pools and fountains). Do not place any objects containing liquids, such as bottles or glasses, on the top of the unit. Do not splash liquids on the unit. IP-20 equipment. There is no protec­tion against splashing water.
8. Ventilation
Slots and openings in the cabinet are provided for ventilation to ensure reliable operation of the amplifier and to protect it from overheating. These openings must not be blocked or covered. This amplifier should not be installed unless proper ventilation is provided or manufacturer’s instruc­tions have been adhered to.
9. Interference of External Objects and/or Liquids with the Appliance
Never push objects of any kind into this amplifier through openings as they may touch dangerous voltage points or short-out parts that could result in fire or electric shock. Never spill liquid of any kind on the amplifier.
P. 2
USER MANUAL
i- SERIES
Page 3
i-SERIES
advancEd amplIfIERS
10. Connections
When you connect the amplifier to other equipment, turn off the power and unplug all of the equipment from the supply source. Failure to do so may cause an electric shock and serious personal injury. Read the user manual of the other equipment carefully and follow the instructions when making the connections.
11. Lightning
For additional protection of this amplifier during lightning storms or when it is left unattended and/or unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the amplifier due to lightning and power line surges. Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket and by external disconnecting all poles from the mains.
12. Damages that require service
Unplug this amplifier from the mains supply and refer to your dealer / dis­tributor or other authorized repair workshop if any of the following situa­tions occur:
if liquid has been spilled or objects have fallen into the amplifier if the amplifier has been exposed to rain or moisture if the amplifier has been dropped or damaged in any other way if the power supply cord or plug has been damaged when the amplifier exhibits a distinct change from its normal function
or performance
IMPORTANT SAFETY INSTRUCTIONS
in case the amplifier has been used in a dusty environment for quite
a period of time
13. Servicing
All service and repair work must be carried out by a dealer / distributor authorized by CAMCO. Do not attempt to service this amplifier yourself. As opening or removing covers may expose you to dangerous voltage or other hazards, the amplifier may only be opened by qualified personnel. Please refer to your dealer / distributor.
14. Spare parts
When spare parts are required, please ensure that the dealer / distribu­tor only uses spare parts specified by the manufacturer. The use of un authorized spare parts may result in injury and / or damage through fire or electric shock or other electricity-related hazards.
15. Safety check
Upon completion of any service or repairs to this product, ask the dealer / distributor to perform safety checks to determine that the amplifier works properly. Recommendations on how to carry out the safety test can be found in DIN VDE 0701-1 “Maintenance, Modification and Test of Electronic Appli­ances“.
16. Cleaning
Unplug this amplifier from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Clean only with dry cloth.
17. Packaging and shipping
When shipping the iD4 amplifier, always use the original shipping carton and packing materials. For maximum protection repack the unit as it was originally packed at the factory.
18. Altitude (for China only)
The amplifier shall only be operated at altitudes below or equal 2000 m.
19. Non-tropics (for China only)
The amplifier shall only be operated in non tropic areas.
P.3
USER MANUAL
i- SERIES
Page 4
EXPLANATION OF SYMBOLS
i-SERIES
advancEd amplIfIERS
EXPLANATION OF SYMBOLS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL IS INTENDED TO
ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS
CONNECTORS! THAT COULD POTENTIALLY BE LIFE THREATENING.
WARNING – TO PREVENT FIRE OR SHOCK HAZARD, DO NOT
VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE.
THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER
TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE
LITERATURE ACCOMPANYING THE AMPLIFIER.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALERTS
THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE OUTPUT
CAUTION – RISK OF ELECTRIC SHOCK – DO NOT OPEN.
EXPOSE THIS AMPLIFIER TO RAIN OR MOISTURE.
THE AMPLIFIER MAY ONLY BE CONNECTED
TO A SOCKET WITH A PROTECTIVE EARTH CONDUCTOR.
CAUTION – HIGH VOLTAGE HAZARDS
EXIST WITHIN THIS PRODUCT.
REFER ALL SERVICING TO
AUTHORIZED PERSONNEL.
P. 4
USER MANUAL
i- SERIES
Page 5
EC DECLARATION OF COMFORMITY
EC Declaration of Conformity in accordance to EC Directives:
Electromagnetic compatibility (Council Directive 2004/108/EC); low-voltage electrical equipment (Council Directive 2006/95/EC)
Manufacturer´s Name:
CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen
Manufacturer´s Address:
Fischpicke 5, D-57482 Wenden, Germany
Declares that the product with the model name:
CAMCO Power amplifier iD4
Conforms to the following standards:
EN60065 Safety EN55103-1 Emission EN55103-2 Immunity
The operating conditions and application environments presupposed in the information for use (user manual) are to be kept accordingly.
Wenden, 17.06.2013
EC DECLARATION OF CONFORMITY
i-SERIES
advancEd amplIfIERS
P.5
Joachim Stöcker
USER MANUAL
i- SERIES
Page 6
i-SERIES
advancEd amplIfIERS
Important Safety Instructions P. 2 Explanation of Symbols P. 4 EC Declaration of Comformity P.5
1. Welcome to CAMCO P.7
1.1 Unpacking P.7
2. The Amplifier P.8
2.1 iD4 – The Front P.9
2.2 iD4 – The Rear P.9
3. Installation P.10
CONTENTS
3.1 Mains Supply P. 10
3.2 On / Off Switch P.10
3.3 Mounting P.11
3.4 Cooling P.11
3.5 Signal Inputs P.12
3.5.1 Analog Input P.12
3.5.2 AES Input P.12
3.6 Remote Control / Network Input P.12
3.7 Power Outputs P.12
3.7.1 SPEAKON® Connection P.12
3.7.2 Dual Channel Operation P. 13
3.7.3 Mono Bridge Operation P. 13
4. Operation P.14
4.1 User Interface Elements P. 14
4.1.1 Signal- / Protect-LEDs (multifunctional) P.14
4.1.2 Clip-LEDs (multifunctional) P.14
4.1.3 CHANNEL Buttons P.14
4.1.4 ITEM Buttons P.14
4.1.5 MENU Buttons P. 15
4.1.6 Rotary Encoder with Push Button P.15
4.2 Hot Key Functions – Standby P.15
4.3 Standby Function P.15
4.4 Power Amp Protection Systems P.16
4.4.1 Clip Limiter / Underimpedance Limiter P.16
4.4.2 SOA Protection P.16
4.4.3 DC Protection P.16
4.4.4 Over Current Protection P.16
4.4.5 Thermal Protection P.16
4.5 Mains Protections P.16
4.5.1 Inrush Current Limitation P.16
4.5.2 Mains Over Voltage Detection P.16
4.5.3 Mains Surge Overvoltage Protection P.16
4.5.4 Mains Failure Detection P.16
4.5.5 Fuse Protection P.17
4.6 Main SMPS Protections P. 17
4.6.1 Over Current Protection P. 17
4.7 Fans P.17
4.8 Filter Cleaning P.18
5. Troubleshooting P.1 9
5.1 Problem: No reaction when switching the amplifier on P. 19
5.2 Problem: No sound P. 19
5.3 Problem: Error message: “Error – amp switched off” P. 1 9
6. Specification P.20
7. Typical Performance Diagrams P.23
8. Unit Conversion Equations and Lookup Table P.26
8.1 Unit Conversion Equations P.26
8.2 Lookup Table P.26
9. Warranty Information P.27
9.1 Summary of Warranty P.27
9.2 Items Excluded from This Warranty P.27
9.3 What CAMCO Will Do P. 2 7
9.4 How to Obtain Warranty Service P.27
9.5 CAMCO Product Improvement P. 27
10. Service Information P.28
11. Maintenance Information P. 29
12. Decommissioning P. 29
13. Company Information P.3 0
14. Changes Made to The Amplifier / Notices P.3 1
P.6
USER MANUAL
i- SERIES
Page 7
i-SERIES
advancEd amplIfIERS
1. Welcome to CAMCO
Thank you for choosing CAMCO products. You are now the proud owner of a very advanced CAMCO Amplifier. The technologies used in your amplifier are of the latest generation and designs delivering a far reaching set of results across all functions.
The amplifier has been designed to be incorporated into a professional speaker system and is suitable for use across all applications from Touring Live Sound to Fixed Installations.
1 WELCOME
Your speaker systems will benefit from the renowned CAMCO sonic qual­ity as well as the many operating functions and features detailed within this manual which are incorporated within the design to maximise results.
The CAMCO peace of mind long term manufactures warranty is our com­mitment to you that every CAMCO amplifier is ready to give you many years of faultless service.
WELCOME TO CAMCO!
1.1 Unpacking
Please unpack and inspect your new amplifier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately. Only you the consignee may initiate a claim for shipping damage. CAMCO will be happy to cooperate fully as needed. Please save the shipping carton as evidence of damage for the shipper’s inspection.
Even if the amplifier has arrived in perfect condition, save all packing mate­rials so you will have them if you ever need to transport the unit.
l NOTE
Never ship the amplifier without the original packing materials.
When shipping the iD4 amplifier, always use the original shipping carton and packing materials. For maximum protection, repack the unit as it was originally packed at the factory.
P.7
USER MANUAL
i- SERIES
Page 8
2. The Amplifier
The iD4 is a Class-H power amplifier with a power output of:
Power output Operating mode
4 500 W monobridge@ 8Ωpeak
3 800 W monobridge@ 8Ω
3 000 W monobridge@ 4Ω
iD4
2 THE AMPLIFIER
2 250 W dualchannel@ 4Ωpeak
2 000 W dualchannel@2,7Ωpeak
1 900 W dualchannel@ 4Ω
1 500 W dualchannel@ 2Ω
i-SERIES
advancEd amplIfIERS
iD4 amplifiers are fitted with Switched Mode Power Supplies (SMPS), which significantly reduces the weight and size (only 2U) of the amplifier. Using SMPS, the 2 symmetrical supply voltages of the power amplifier are more stable than the power supplies used in conventional amplifiers.
The iD4 has been designed as a powerful two channel amplifier with on­board 64 bit DSP processing. Both amplifier settings and DSP settings can be user adjusted to match a speaker systems specifications. With up to 100 onboard speaker pre-set storage capability, fine tuning of a system or differing systems is fast, easy and strait forward; the user interface is designed to be intuitive allow for quick familiarisation. The combination of both power amplifier and on-board DSP technologies used in the iD4, provide the level of control and audio quality expected in any professional applications. The iD4, a very powerful and complete speaker management system, with optimum flexibility and maximum con­trol and security.
Since some of the externally mounted controls have multiple functions, it is important that users should familiarise themselves thoroughly with the entire range of controls.
P.8
USER MANUAL
i- SERIES
Page 9
   
2 THE AMPLIFIER
2.1 iD4 – The Front
Signal-LEDs Clip-LEDs Character LCD Channel buttons Item buttons Menu buttons Rotary encoder with push button Removable air filter system Cooling air inlet vents On/Off switch
i-SERIES
advancEd amplIfIERS
2.2 iD4 – The Rear
XLR – line input 1 XLR – line input 2 AES input Ethernet network input Cooling air outlet vents SPEAKON® output 2 SPEAKON® output 1 Rating plate AC power cable
P.9
USER MANUAL
i- SERIES
MODEL:
OUTPUT PWR P E R CH/IMP:
SER . NO.:
iD 4
220 V ~ 50 / 60 Hz 11,3 A 1220 W
xxxxx
1900 W / 4 Ohm
MADE IN GER MANY
Page 10
i-SERIES
advancEd amplIfIERS
3. Installation
3.1 Mains Supply
When mounting or connecting the amp always disconnect it from mains. Only connect the iD4 amplifier to an appropriate AC circuit and outlet, according to the requirements indicated in the second line on the rating plate.

   
 
3 INSTALLATION

   
 
120 V ~ 50/60 Hz 22,6 A 1220 W
230 V ~ 50/60 Hz 11,3 A 1220 W
iD4
1900 W / 4 Ohm
  
iD4
1900 W / 4 Ohm
  

220 V ~ 50/60 Hz 11,3 A 1220 W
   
 
iD4
Exemplary rating plates for the three available amplifier variants.
Power supply data of all available variants:
Operating condition
Mains
current
(4Ω/2Ω)
Power
consumption
(4Ω/2Ω)
Amplifier standby (power off) < 0,5 A 8 W 0 W
Idle (amplifier powered on) 1,3 A 70 W 0 W
iD4
250 W per channel 8,5 / 10 A 1 220 / 1 500 W 500 W
Measured with pink noise with crest factor of 12 dB to represent typical music signal.
Mains current draw and power consumption @ 230 V, 50 Hz
For 120 V mains operation, the current values can be multiplied by 2.
1900 W / 4 Ohm
  
Output
power
3.2 On / Off Switch
The On / Off Switch is a rocker-type switch. It is located on the right side of the front panel. To turn the amplifier on, press on the upper part of the switch. During power up the Clip- and Signal-LEDs from both channels will light up in red for a few seconds. To turn the amplifier off, press on the lower part of the switch.
Amplifier is switched on Amplifier is switched off
l NOTE
This switch does NOT disconnect the amplifier from mains. Discon-
necting the amplifier from the main power supply can only be achieved by disconnecting the mains plug or by an external all-pole disconnection (e.g. a mains / circuit breaker). The mains plug or circuit breaker therefore has to be freely accessible at all times. Disconnect the mains plug from the mains during a lightning storm or when the amplifier remains unused or unsupervised for a prolonged period of time.
The switch initiates start-up by activating the inrush current limiter. As soon as the power amplifier is connected to the mains power supply, a vol tage is supplied to both the line-filter and the fused input of the controllable rectifier. If a power cut occurs while the amplifier is switched on, it will restart auto­mati cally once the power supply has been restored. All amplifier settings prior to the loss of power will be maintained.
P.10
USER MANUAL
i- SERIES
Page 11
i-SERIES
88,10 mm
7,50 mm
advancEd amplIfIERS
3.3 Mounting
Use four screws and washers when mounting the amplifier to the front rack rails. For mobile use, the amplifier should also be secured using the 19” mounting elements on the rear panel.
10,50 mm
3 INSTALLATION
76,20 mm
465,0 mm
442,00 mm
418,60 mm
483,00 mm
431,00 mm
409,60 mm
3.4 Cooling
The air is taken in from the front and out through the back. It is essential that while the amplifier is running the air is able to circulate around it freely. The efficiency of the cooling will depend on the immediate environment (e.g. an enclosed rack, direct sunlight). If the amp is installed in a case, the open area at the back of the case must be at least 140 cm². This area should be in line with the amplifier.
If this cannot be achieved a forced ventilation system has to be used.
Note that continous high power draw at low load impedance (equal or
lessthanapprox.2,7Ω)candrivethe amplifierintothermallimitation.So
please check the amplifier temperatures on the display or in the DSP con­trol application and reduce the onput levels if necessary.
P.11
USER MANUAL
i- SERIES
Page 12
i-SERIES
advancEd amplIfIERS
3.5 Signal Inputs
3.5.1 Analog Input
XLR: Pin 1 = Ground Pin 2 = Hot (inphase) Pin 3 = Cold (out of phase)
Always use symmetrical (balanced) shielded cable to connect the amplifier.
3.5.2 AES Input
The digital AES XLR input accepts any AES / EBU signals (pro or consumer format) in 16 to 24 bit resolution and 44,1, 48, 88,2, or 96 kHz samplig fre-
3 INSTALLATION
quency. This wide input frequency range of is guaranteed by an integrated sample rate converter (SRC) chip.
3.6 Remote Control / Network Input
The Ethernet Link network connector allows you to access the iD4 from a host computer for remote control, firmware update and downloading DSP presets. The iD4 is configured by default to use DHCP for automatic IP address assignment in the network. If not desired, this feature can be set through the DSP Control application.
3.7 Power Outputs
3.7.1 SPEAKON® Connection
Both SPEAKON outputs. The pin configuration of the SPEAKON connectors is as follows:
SPEAKON (View at the back) Pin 1 – Channel 1 ground Pin 2 + Channel 2 signal Pin 2 – Channel 2 ground
SPEAKON® left: Pin 1 + Channel 2 signal (View at the back) Pin 1 – Channel 2 ground Pin 2 + Channel 1 signal Pin 2 – Channel 1 ground
! WARNING!
SPEAKON® connectors marked with the lightning flash indicate high vol tages that are potentially life threatening.
Wiring to these terminals requires installation by an instructed person or the use of ready-made leads or cords. Custom wiring should only be made by qualified personnel. To prevent electric shock, do not operate the amplifier with any of the con­ductor portion of the speaker wire exposed.
l NOTE
For reasons of safety and performance, use only high-quality fully in su lated speaker cables of stranded copper wire. Use the largest
wire size that is economically and physically practical, and make sure the cables are no longer than necessary.
l NOTE
When connecting speaker cabinets in parallel, always use all the con­tacts in both SPEAKON
damage to the connectors and considerably reduce performance.
®
connectors are connected to channel 1 and channel 2
®
right: Pin 1 + Channel 1 signal
®
connectors. If not, this may cause permanent
P.12
USER MANUAL
i- SERIES
Page 13
i-SERIES
iD4
iD4
advancEd amplIfIERS
3.7.2 Dual Channel Operation
Two fully independent amplifier channels (“Stereo” – normal operating mode).
In 1
In 2
Z
=2ΩforDualChanneloperation
min
3 INSTALLATION
3.7.3 Mono Bridge Operation
One-channel mono bridged operation.
In 1
180°180°
In 2
=4ΩforMonoBridgeoperation
Z
min
In this mode the channel 2 amplifier stage processes the identical input signal than channel 1, but with reversed phase. The channel 2 input signal is not used / ignored. The loudspeaker load must then be connected between the two posi­tive channel outputs (pin 1+ and pin 2+) using a specially configured SPEAKON
®
connector / cable. This effectively doubles the maximum out­put voltage. But please note that this also doubles the minimum allowed loudspeaker impedance Z
.
min
! WARNING!
In Mono Bridge Operation RMS output voltages can be as high as 200 VAC.
Wiring to the speaker loads must conform to NEC class 3 safety stand­ards or its equivalent that meets all national and local electric codes. All customer specific cables may only be manufactured by qualified suppli­ers / personnel. All cabling or rewiring work must be carried out by quali­fied personnel.
P. 13
USER MANUAL
i- SERIES
Page 14
i-SERIES
advancEd amplIfIERS
P.14
4. Operation
4.1 User Interface Elements
l NOTE
This chapter only describes the basic user interface operation and functions. Please refer to the separate DSP Control manual for an expla-
nation of the extensive Digital Signal Processing (DSP) options and advanced features offered by the remote application.
4 OPERATION
4.1.1 Signal- / Protect-LEDs (multifunctional)
The Signal-LEDs are illuminated in green when the voltage level at the
outputreachesapprox.4V;thiscorrespondstoapowerof4Wintoa4Ω
load. The channel Signal-LEDs are illuminated red when the amplifier is in Protect Mode (Mute), for example because of persistent DC-voltage at the outputs or overheating. When switching the amplifier on, the Signal-LEDs will also light red for a few seconds while the DSP is starting up (along with the Clip-LEDs). In case the FuseProtect limiter is activated, it is possible that the (green) Signal-LED’s will glow in orange or red colour for short periods of time while the amplifier is playing music.
4.1.2 Clip-LEDs (multifunctional)
The colour of the bi-coloured LED changes between orange and red, depending on the clip intensity. Orange indicates light clipping, red indi-
USER MANUAL
i- SERIES
à
See also chapter 4.5.5 Fuse Protection
cates heavy clipping. These LED’s exclusively indicate hardware clipping of the power amplifier stage. Possible internal DSP limitation and compres­sion is not indicated here.
4.1.3 CHANNEL Buttons
The CHANNEL buttons allow to select the channels to make adjustments on. Selectable items are In 1 to In 4 and Out 1 and Out 2 (depending on user and access rights). Note that if channels are linked the settings will always affect both linked channels. In this case the channel selection will display In 12, In 34 or Out 12.
4.1.4 ITEM Buttons
The ITEM buttons allow you to navigate trough all parameters which can be set from the front panel. Note that currently only a small choice of parameters can be set from the amplifier user interface. For full access on all settings and parameters please use the DSP Control remote control application. The parameters are:
Gain à Gain settings in 0,25 dB steps Source à Selects the source of the chosen input channel:
Delay à Signal delay settings Link à Selects if Input 1 & 2, Input 3 & 4 or Output 1 & 2 shall be
Analog AES Channel 1 AES Channel 2 AES Mono Sum AES Stereo
linked
*
Smaller steps (0,01 dB) can be set via the DSP Control remote application.
*
Page 15
i-SERIES
advancEd amplIfIERS
All settings and selections are done through the rotary encoder. Changes will take effect immediately.
4.1.5 MENU Buttons
The left (3) MENU button will always act as an ESCAPE / EXIT button. The right (4) MENU button offers following sub-menus, accessible through repeated pressing on the right MENU button:
Load preset Save preset
4 OPERATION
Access Level control Auxilliary information:
à
Version Info Serial Number (SN)
à
Version Info FW Version (SW)
à
Version Info Hardware Version (HW)
à
IP Address
à
MAC Address
à
Temperature of both amplifier stages
Inside the Auxilliary information menu you can navigate through the sub menus with the encoder wheel. Note that in this menu the encoder will only work in a round-robin fashion, regardless of the rotation direction.
l NOTE
The left (3) MENU button always acts as an ESCAPE / EXIT button in all menus.
4.1.6 Rotary Encoder with Push Button
The rotary encoder allows to make swift adjustments of parameters (like for example the Gain settings) by simply turning it in the desired direction. In some menus the push-function of the encoder will act as an ENTER button, for example when selecting / loading presets.
4.2 Hot Key Functions – Standby
To set the iD4 to standby mode simply press both (34) MENU buttons simultaneously for more than three seconds. You will then be asked if you want to switch to Standy Mode. Pressing the encoder knob (without rotat­ing it) will then power down the main power supply of the iD4. The standby function can of course also be controlled by the DSP Control remote application.
4.3 Standby Function
The iD4 offers the possibility to set the amplifier into standby mode either from the user interface or by the DSP Control remote application. In standby mode the iD4 will power down it’s main SMPS, thus saving energy while at the same time staying accessible via network connection.
From the amplifier’s user interface this function is accessible through a Hot Key function as described above. Inside the DSP Control remote application you can access this function through the Hardware menu.
An additional feature is the automatic standby function which will set the iD4 in standby mode if no input signal (analogue and / or AES) is applied for a certain period of time. This delay time can be set individually (or switched off) inside the DSP Control remote application through the Hardware à Configure à Standby Delay menu.
l NOTE
If the amplifier has been set into standby through the auto-standby function, automatic wakeup will only work if digital AES input signal is applied again.
Applying analogue signal again will not wakeup the amplifier. When unsing analogue input signal, exiting the automatic standby mode must be done manually through the user interface or the DSP Control remote application. So please consider this carefully before using this function with analogue input signal.
P.15
USER MANUAL
i- SERIES
Page 16
i-SERIES
advancEd amplIfIERS
4.4 Power Amp Protection Systems
4.4.1 Clip Limiter / Underimpedance Limiter
The DSP section of the iD4 offers various limiter and compressor settings, both on the signal inputs and on the signal outputs. Those limiters and compressors can be adjusted and even switched off completely if desired. Disabling the limters is done by setting the thresholds to their highest values.
But in case the amplifier is driven into hardware clip (i. e. when the Clip-
4 OPERATION
LED is glowing orange or red) for longer periods of time, the threshold setting of the output limiter will automatically be reduced temporarily. Note that this is automatically done inside the amplifier and cannot be seen in the DSP control application. This automatic threshold reduction will especially take place at low output
impedances(smaller 4Ω)andhigh outputpowersand shallprevent the
amplifier from being operated in continuous hard amplifier cliping.
4.4.2 SOA Protection
Whenever the power transistors leave their Safe Operation Area (SOA), the SOA-protection switches back the rail of the respective channel.
4.4.3 DC Protection
Each output of the power amp is constantly monitored for persis­tent DC voltage levels. If the 3 V thresholds are exceeded at any of the outputs, the corresponding channel will be muted. If DC was only detected for a short moment, the amplifier will release mute and work as normal. If DC is detected for longer periods or repeatedly, the amplifier will switch to standby mode and disable the main power supply. If this happens the display will indicate “Error – amp switched off”. In this case, switch off the amplifier for at least 4 minutes and switch the amplifier on again.
4.4.4 Over Current Protection
Over current is permanently controlled in the output stage. There are two limit ing levels of over current depending on output voltage. These limits will be set automatically. This improves reliability without degrading sound quality when driving complex loads.
4.4.5 Thermal Protection
There are several sensors inside the amplifier in order to ascertain tem­perature data. If a temperature of more than 85 °C is detected at the heat sinks, the input signal on that channel is reduced.
4.5 Mains Protections
4.5.1 Inrush Current Limitation
Within 2 seconds of the amplifier being switched on, the inrush current limiter will increase mains current from nearly zero to nominal value. This value depends on program material, output level and speaker loads.
4.5.2 Mains Over Voltage Detection
Mains over voltage detection is always operative. When the mains voltage exceeds approx. 263 V (220 / 230 V operation) or 134 V (110 / 120 V opera­tion), the amplifier will be switched off. The system will try to restart in inter­vals and will return with a soft start when the regular mains voltage returns.
4.5.3 Mains Surge Overvoltage Protection
The iD4 is fitted with a varistor unit, protecting the SMPS from sporadic surge overvoltages coming from the mains distribution.
4.5.4 Mains Failure Detection
Mains failure detection is always operative. When the mains supply is inter­rupted for about 2 mains cycles, the amplifier will be switched off. When the mains voltage returns to a normal value, a soft start occurs.
P.16
USER MANUAL
i- SERIES
Page 17
i-SERIES
advancEd amplIfIERS
4.5.5 Fuse Protection
When driving the iD4 at very high output levels over a longer period of time (i.e. several seconds and minutes) the average mains current draw can become very high. In such situations, the FuseProtect limiter will reduce the output signal in order to prevent the external mains breaker from trip­ping. But this limiter in turn will not affect the output signal on dynamic music signal and short current peaks, thus guaranteeing the full available peak output power. Please note that the FuseProtect limiter only controls the average mains input current, not the short term peak input current. This means that with
4 OPERATION
very dynamic music signals the (short term) input current can still reach very high levels, which can be very demanding for a mains distribution. If active, the operation of the FuseProtect limiter can be seen by short orange or red glowing of the Signal-LED’s.
4.6 Main SMPS Protections
4.6.1 Over Current Protection
Main SMPS (Switched Mode Power Supply) transformer current is continu­ously monitored. If over current occurs, the main SMPS immediately stops working. Should there be an internal failure, this feature prevents other parts being damaged.
4.7 Fans
The fans mounted in the iD4 operate permanently, but as long as the tem­perature remains below 40 °C they run at their slowest speed and can hardly be heard. The highest detected temperature from either channel controls the speed of the fans: above 40 °C the speed is increased until it reaches its maximum value.
P. 17
USER MANUAL
i- SERIES
Page 18
i-SERIES
advancEd amplIfIERS
4.8 Filter Cleaning
The air intake on the front of your iD4 amplifier is fitted with a removable filter system. If the filter becomes clogged, the unit will not cool as effi­ciently as it should and may result in reduced output levels.
iD4 Filter Assembly
Foam filter Front frame Screw
4 OPERATION
! WARNING!
Turn off and disconnect the amplifier from the mains before removing the front frame.
To clean or replace the filter just slightly unscrew the fixing screw with the help of a 3 mm allen key. The screw will be held back by a small plastic spacer on the back of the frame to avoid losing it. Then shift the front frame slightly to the right. Then you should be able to remove the frame from the amplifier completely (pull gently to avoid any bending of the front frame).
P.18
USER MANUAL
i- SERIES
Page 19
5. Troubleshooting
5.1 Problem: No reaction when switching the amplifier on
If nothing happens when switching the amplifier on (i.e. the display stays totally dark, no message inside the display), please check following points:
Check mains cable and plug Confirm that the AC outlet works by plugging in any other device
5.2 Problem: No sound
If no sound can be heard on the outputs please check following DSP set­tings (through the DSP control application):
Input source selection Input and output gain settings Input and output limiter settings If digital (AES) input signal is used, please check AES signal source
(samplig frequency, bit resolution and signal quality (long cables))
5 TROUBLESHOOTING
5.3 Problem: Error message: “Error – amp switched off”
This error message indicates an internal error which forced the main power supply (SMPS) to be switched off. This can be caused by:
Detection of permanent DC on the outputs Detection of amplifier stage malfunction (protect) Detection of main SMPS error
You can try to power-cycle the amplifier to reset all amplifier stage detec­tion circuits. This might help in case the DC or amplifier fault was caused by an invalid input signal (e.g. an extremely high frequent or extremely distorted input signal). For this please switch off the amplifier for at least 4 minutes and switch the amplifier on again. If the message still appears after this procedure the fault is permanent and the amplifier requires servicing.
i-SERIES
advancEd amplIfIERS
P. 19
USER MANUAL
i- SERIES
Page 20
6. Specification
6 SPECIFICATION
1 kHz, THD 1%, in dual channel operation
durationlimitedbyfuse/thermalprotectionforRL≤8Ω
typical values @ 230 V / 50 Hz
Peak output power
Output power
1 kHz, single sine wave in dual channel operation
typical values @ 230 V / 50 Hz, may be subjected to component tolerances
Mono bridge operation output power
1 kHz, THD ≤1%,inmonobridgeoperation
durationlimitedbyfuse/thermalprotectionforRL≤16Ω
1 kHz, single sine wave in mono bridge operation
typical values @ 230 V / 50 Hz, may be subjected to component tolerances
typical values @ 230 V / 50 Hz
70 / 100 V line operation output power
* only possible in mono bridge operation (single channel)
1 kHz, THD ≤1%
Circuitry Bipolar, Class H 2 step high efficiency circuit
Signal to noise-ratio
10 Hz – 20 kHz, 8 Ωload
* both channels driven at 250 W output power (approx. of max. THD limited output power
in dual channel operation; typical values, may be subjected to component tolerances
Power consumption @ 230 V
with pink noise to represent typical music signal)
Maximum output voltage
in dual channel operation; typical values @ 230 V / 50 Hz
Maximum output current
advancEd amplIfIERS
2 × 600 W @ 16 Ω 2 × 1 100 W @ 8 Ω 2 × 1 900 W @ 4Ω 2 × 1 950 W @ 2,7Ω 2 × 1 500 W @ 2Ω
2 × 630 W @ 16Ω 2 × 1 240 W @ 8Ω 2 × 2 250 W @ 4Ω 2 × 2 000 W @ 2,7Ω 2 × 1 500 W @ 2Ω
1 × 2 200 W @ 16 Ω 1 × 3 800 W @ 8 Ω 1 × 3 000 W @ 4 Ω
1 × 2 480 W @ 16 Ωpeak 1 × 4 500 W @ 8 Ωpeak 1 × 3 000 W @ 4 Ωpeak
2 × 1 800 W @ 70 V line 1 × 2 500 W* @ 100 V line
> 102 dB (unweighted) > 105 dB (A-weighted)
Amplifier standby (power off): 8 W
Idle (Amp powered on): 70 W
4Ω:1 220W 2Ω:1 500W
± 142 V peak
± 39 A peak
We reserve the right to make technical alterations without prior notice.
*
*
i-SERIES
*
*
*
P.20
USER MANUAL
i- SERIES
Page 21
i-SERIES
advancEd amplIfIERS
6 SPECIFICATION
Frequency response
@ 4 Ω load with 120 W ouptut power
THD+N over frequency
@ 4 Ω load with 120 W output power
Damping factor
8 Ω load, 1 kHz and below
10 Hz – 20 kHz: ± 0,175 dB
20 Hz – 10 kHz: < 0,02 %
> 400
Input impedance 29 kΩ balanced
Amplifier gain 32 dB default (adjustable through DSP)
Maximum analogue differential input level +22,2 dBu / 10 V
Level attenuation Done through DSP in 0,25-dB-steps
Minimum loudspeaker load impedance
Lower values are safe, but out of specification. No performance guarantees
can be given when driving lower impedances than specified.
Z
= 2 Ωfor Dual-Channel operation
min
Z
= 4 Ωfor Mono Bridge operation
min
Protection circuits Inrush-current limitation, mains surge overvoltage protection, temperature monitoring of heatsinks,
output DC protection, temperature dependent SOA protection, mains fuse protection, output cur­rent limitation, thermal limitation
Analogue limiters (HW) Clip / Underimpendance Limiter, FuseProtect Limiter
Cooling Two temperature dependent speed-controlled axial fans
LED indicators LEDs for signal / protect and clip
Input connectors Two 3-pin XLR female analogue input connectors, pin 2 = hot (inphase)
Two 3-pin XLR male passive loop through connectors One 3-pin XLR female AES (digital) input connector One Ethernet connector RJ45
Power output connectors One 4-pole SPEAKON
Modes of operation Dual channel (Stereo), mono bridge
Input sources Analogue, AES
A/D – D/A converters 24 bit / 96 kHz
/ 14,2 V
RMS
Peak
®
connector for each output channel (bi-amping possilbe)
We reserve the right to make technical alterations without prior notice.
P. 21
USER MANUAL
i- SERIES
Page 22
6 SPECIFICATION
Latency Min. 0,58 ms
Digital inputs AES / EBU, 16 to 24 bit, 44,1, 48, 88,2, or 96 kHz
Amplifier output power performance will decrease with lower mains voltages than the rated 230 V / 220 V / 120 V and slightly
* Approximative mains voltage range where the amplifier can be used.
increase with higher mains voltages.
AC mains
Operating temperature +5 °C to +55 °C / +41 °F to +131 °F
Dimensions (W × H × D) 483 × 88,1 × 419 mm / 19 × 3,5 × 16,5 inches (19”, 2U)
Net weight 9,4 kg / 20,7 lbs
Shipping dimensions (W × H × D) 600 × 105 × 527 mm / 23,3 × 4,1 × 20,7 inches
Shipping weight 11 kg / 24,3 lbs
advancEd amplIfIERS
230 V AC, 50 / 60 Hz (for Europe), 190 – 263 V 220 V AC, 50 / 60 Hz (for China), 190 – 263 V 120 V AC, 50 / 60 Hz (for US), 95 – 134 V
We reserve the right to make technical alterations without prior notice.
*
i-SERIES
*
*
P.22
USER MANUAL
i- SERIES
Page 23
dBu
1
Hz
1
7. Typical Performance Diagrams
+1
+0,5
0
-0,5
-1
-1,5
dBr
-2
-2,5
-3
-3,5
-4
Hz
Figure 7.1
Gain vs. frequency, 120 W output power
(Measurement of a typical performance @ 2 Ω & 4 Ω)
i-SERIES
advancEd amplIfIERS
1
0,1
%
0,01
20k10k1k10010
0,001
-60 -50 -40 -30 -20 -10 0 4 dBu
Figure 7.3
THD@1kHzvs.inputlevel@2Ωload(32dBamplifiergain)
(Measurement of a typical performance of Ch 1 & Ch 2)
0,1
%
0,01
7 TYPICAL PERFORMANCE DIAGRAMS
0,001
-60 -50 -40 -30 -20 -10 0 10
Figure 7.2
THD@1kHzvs.inputlevel@4Ωload(32dBamplifiergain)
(Measurement of a typical performance of Ch 1 & Ch 2)
USER MANUAL
P. 23
i- SERIES
0,1
%
0,01
0,001
10020
1k
Figure 7.4
THD vs. frequency, 120 W output power
(Measurement of a typical performance @ 2 Ω & 4 Ω)
20k10k
Page 24
i-SERIES
dBu
10
Hz
100
advancEd amplIfIERS
0
-20
-40
-60
dBr
-80
-100
-120
Hz
20k10k1k10010
Figure 7.5
Channelseparationvs.frequency@120W/4Ω
(Measurement of a typical performance of Ch 1 à Ch 2 & Ch 2 à Ch 1)
1
0,1
%
7 TYPICAL PERFORMANCE DIAGRAMS
0,01
0,001
-60 -50 -40 -30 -20 -10 0 10
Figure 7.6
DIM100 vs. input level (32 dB amplifier gain)
(Measurement of a typical performance of Ch 1 & Ch 2)
0
-10
-20
-30
-40
dBr
-50
-60
-70
-80 1k 10k 20k10 100
Hz
Figure 7.7
Common mode rejection ratio vs. frequency
(Measurement of a typical performance of Ch 1 & Ch 2)
10
1
100 m
10 m
V
1 m
100 µ
10 µ
1 µ
20k10k1k10010
Figure 7.8
FFT of noise level (no input signal applied, analog input, 32 dB amplifier gain)
(Measurement of a typical performance of Ch 1 & Ch 2)
P. 2 4
USER MANUAL
i- SERIES
Page 25
i-SERIES
advancEd amplIfIERS
300 m
100 m
Ω
10 m
2 m
20 100 1k 10k 20k
Hz
Figure 7.9
Output impedance vs. frequency
@1AmpRMSinjectedcurrentequivalent11mΩ+2,1µH
(Measurement of a typical performance of Ch 1 & Ch 2)
7 TYPICAL PERFORMANCE DIAGRAMS
1000
800
600
400
damping factor
200
0
Hz
20k10k1k10010
Figure 7.10
Dampingfactorinto8Ω
(equation: damping factor = loaded impedance / amplifier output impedance)
(Measurement of a typical performance of Ch 1 & Ch 2)
P. 25
USER MANUAL
i- SERIES
Page 26
i-SERIES
advancEd amplIfIERS
8. Unit Conversion Equations and Lookup Table
8.1 Unit Conversion Equations
Unit conversion Equation
à dBu
V
RMS
V
à dBV
RMS
dBu à V
RMS
dBV à V
RMS
V
à V
RMS
Peak
8Ω4Ω2Ω
8 UNIT CONVERSION EQUATIONS
V
à Output power
RMS
8.2 Lookup Table
Output
V
RMS
V
Peak
dBu dBV
power
in W
(8Ω)
Output
power
in W
(4Ω)
Output
power
in W
(2Ω)
1 2,83 2,22 0,00 0,13 0,25 0,50
2 5,66 8,24 6,02 0,50 1,00 2,00
3 8,49 11,76 9,54 1,13 2,25 4,50
4 11,32 14,26 12,04 2,00 4,00 8,00
5 14,14 16,20 13,98 3,13 6,25 12,5
6 16,97 17,78 15,56 4,50 9,00 18,0
7 19,80 19,12 16,90 6,13 12,3 24,5
8 22,63 20,28 18,06 8,00 16,0 32,0
9 25,46 21,30 19,08 10,1 20,3 40,5
10 28,29 22,22 20,00 12,5 25,0 50,0
12 33,95 23,80 21,58 18,0 36,0 72,0
15 42,43 25,74 23,52 28,1 56,3 112,5
20 56,58 28,24 26,02 50,0 100,0 200,0
30 84,87 31,76 29,54 112,5 225,0 450,0
40 113,15 34,26 32,04 200,0 400,0 800,0
50 141,44 36,20 33,98 312,5 625,0 1250,0
60 169,73 37,78 35,56 450,0 900,0 1800,0
70 198,02 39,12 36,90 612,5 1225,0 2 450,0
80 226,31 40,28 38,06 800,0 1600,0 3 200,0
90 254,60 41,30 39,08 1012,5 2025,0 4 050,0
100 282,89 42,22 40,00 1250,0 2 500,0 5000,0
120 339,46 43,80 41,58 1800,0 3 600,0 7200,0
150 424,33 45,74 43,52 2812,5 5 625,0 11250,0
Values in grey are calculated only. The iD4 is not able to deliver these output powers.
P.26
USER MANUAL
i- SERIES
Page 27
i-SERIES
advancEd amplIfIERS
9. Warranty Information
9.1 Summary of Warranty
CAMCO guarantees the iD4 amplifier to be free from defective material and / or workmanship for a period of six (6) years from the date of sale. When a defect occurs under normal installation and use, CAMCO will repair the product under this warranty. In this event, please return the amplifier to your dealer / distributor together with a copy of your sales receipt as proof of purchase.
This warranty provides that examination of the returned product must indi­cate in our judgment a manufacturing defect.
9.2 Items Excluded from This Warranty
CAMCO is not liable for any damage caused by shipping accidents, misuse, abuse, operation with incorrect AC voltage, operation with faulty peripheral equipment, modification or alteration without prior factory approval, service by an unauthorised service center and normal wear and tear. Amplifiers on which the serial number has been removed or defaced are not eligible for warranty service.
9.3 What CAMCO Will Do
9 WARRANTY INFORMATION
CAMCO (or its appointed agent) undertakes to rectify any defect regard­less of the reason for failure (unless excluded from this warrenty), by repair, replacement or refund as it sees fit.
9.4 How to Obtain Warranty Service
You must notify your dealer / distributor of your need for warranty service. All components must be shipped in the original packaging.
9.5 CAMCO Product Improvement
CAMCO reserves the right to improve the technical standard of its prod­ucts without giving prior notice. If in any doubt, please consult your dealer / distri butor or contact CAMCO directly for clarification.
P. 27
USER MANUAL
i- SERIES
Page 28
P.28
10. Service Information
PLEASE ENCLOSE THIS COMPLETED FORM WITH THE AMPLIFIER
Owner’s Information
Company Name:
Contact:
Address:
Telephone:
Facsimile:
10 SERVICE INFORMATION
E-Mail Address:
Model:
Serial Number:
Purchase Date:
Expired Warranty
If the warranty has expired, payment will be:
Cash / Cheque VISA MasterCard
Shipping Address
To transport the amplifier, the original packing materials must be used. Please return the amplifier to the address on the right side or your nearest CAMCO appointed distributor.
USER MANUAL
i- SERIES
i-SERIES
advancEd amplIfIERS
DO NOT SEND SEPARATELY
Nature of problem occurred
Please describe the conditions that existed when the problem occured and what attempts were made to correct it:
Other equipment in your system:
Our web site: www.camcoaudio.com provides a complete list of CAMCO dealers / distributors.
CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen, Fischpicke 5, 57482 Wenden, Germany
Page 29
i-SERIES
advancEd amplIfIERS
12 DECOMISSIONING
11 MAINTENANCE INFORMATION /
11. Maintenance Information
Cleaning and servicing the inside of the amplifier must never be carried out by unqualified personnel. The amplifier must never be opened by unquali­fied personnel.
Cleaning and servicing work on the inside of the amplifier must only be carried out by qualified personnel.
Qualified personnel is defined as a person who has gained specialised relevant knowledge of electronic engineering through education, training, and experience, and who has sufficient knowledge of all relevant gov­ernmental work safety regulations to be in a position to judge the safe functioning of power amplifiers based on technical rules according to IEC 60065 (IEC 60065 (DIN EN 60065) “Safety Requirements for Audio, Video or simlar Electronic Appliances”).
In order to guarantee the safe functioning of the amplifier, it has to be checked regularly, depending on its application but at least once a year, by a properly qualified person. Advice on how to carry out these checks can be found in DIN VDE 0702-1 “Safety Checks for Electronic Appliances” .
An amplifier that is considered to be unsafe must be labelled accordingly and stored in a safe place to prevent this amplifier being used mistakenly.
12. Decommissioning
During the decommissioning process of the amplifier, all legally prescribed rules and procedures must be adhered to.
P. 29
USER MANUAL
i- SERIES
Page 30
13. Company Information
Mailing Address:
CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany
Telephone:
+49 (0) 27 62 / 408 - 0
Facsimile:
+49 (0) 27 62 / 408 - 10
Internet:
www.camcoaudio.com
E-Mail:
postmaster@camcoaudio.com
13 COMPANY INFORMATION
i-SERIES
advancEd amplIfIERS
P.3 0
USER MANUAL
i- SERIES
Page 31
14. Changes Made to The Amplifier / Notices
l NOTE / IMPORTANT:
Please consider that any changes made to the amplifier have to be docu­mentated in writing and passed on to the buyer in the event of resale!
NOTICES
i-SERIES
advancEd amplIfIERS
14 CHANGES MADE TO THE AMPLIFIER /
P.3 1
USER MANUAL
i- SERIES
Page 32
NOTICES
i-SERIES
advancEd amplIfIERS
14 CHANGES MADE TO THE AMPLIFIER /
P.3 2
USER MANUAL
i- SERIES
Loading...