2) Please keep this user manual in a safe place during the lifetime of the amplier. The user manual forms an integral part of the amplier. Reselling of the
amplier is only possible if the user manual is available. Any changes made to
the amplier have to be documentated in writing and passed on to the buyer
in the event of resale.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this amplier near water (for example, in damp rooms or near a
swimming pool).
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with the user
manual.
IMPORTANT SAFETY INSTRUCTIONS
8) Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus that produce heat.
9) Protect the power cord from being walked on, pinched or damaged in any
other way. Pay particular attention to plugs and the point where they exit from
the amplier.
10) The amplier may only be used in accordance with the information provided
in the user manual. Before and during the usage of the amplier please ensure
that all recommendations, especially the safety recommendations as detailed in
the user manual, are adhered to.
The TECTON-Amplier is designed for the amplication of pulsed audio signals
and the amplier should only be connected to speakers with an average
impedance that is not lower than the impedances specied in points 3.8.3, 3.8.4
and 3.8.5.
11) Do not place this amplier on an unstable cart, stand,
tripod, bracket, or table. The device may fall, causing
serious injury, and serious damage to the device itself.
12) The amplier can only be disconnected from the power supply by removing
the plug, which must be freely accessible at all times. Unplug this amplier
during lightning storms or when unused for long periods of time.
13) Refer all servicing to qualied service personnel.
Servicing is required when
the power-supply cord or plug has been damaged,
liquid has been spilled or objects have fallen into the amplier,
the amplier has been dropped or damaged in any other way,
the amplier has been exposed to rain or moisture,
when the amplier exhibits a distinct change from its normal function or
performance.
USER MANUAL
TECTON POWER AMP SERIES
P.2
Page 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION – HIGH VOLTAGE HAZARDS
EXIST WITHIN THIS PRODUCT.
REFER ALL SERVICING TO
AUTHORISED PERSONNEL.
1. Read the information for use (user manual)
When shipping the TECTON amplier, always use the original shipping carton
and packing materials. For maximum protection, repack the unit as it was originally packed at the factory.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL, IS INTENDED TO
ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS
VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE.
THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER
TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE
LITERATURE ACCOMPANYING THE AMPLIFIER.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALERTS
THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE SPEAKON
CONNECTORS THAT COULD POTENTIALLY BE LIFE THREATENING.
CAUTION – RISK OF ELECTRIC SHOCK – DO NOT OPEN.
WARNING – TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS
AMPLIFIER TO RAIN OR MOISTURE.
THE AMPLIFIER MAY ONLY BE CONNECTED
TO A SOCKET WITH A CONNECTION TO GROUND.
2. Environments
Use this amplier only in E1, E2, E3 or E4 environments according to EN55103-2
“Electro-magnetic compatibility – Product-family norm for audio, video and
audio-visual installations as well as for studio-and lighting-control installations
for professional applications – Part 2: Immunity“.
3. Ventilation
Slots and openings in the cabinet are provided for ventilation, to ensure reliable
operation of the amplier and to protect it from overheating. These openings
must not be blocked or covered. This amplier should not be operated unless
proper ventilation is provided or manufacturer’s instructions have been
adhered to.
4. Water And Moisture
Do not use this amplier near water (for example, in a wet basement or near a
swimming pool).
5. Cleaning
Unplug this amplier from the wall outlet before cleaning. Do not use liquid or
aerosol cleaners.
6. Power-cord Protection
Power-supply cords should be routed so that they are not likely to be walked on
or pinched by items placed upon them or against them, paying particular attention to cords and plugs, and the point where they exit from the amplier.
USER MANUAL
TECTON POWER AMP SERIES
EXPLANATION OF SYMBOLS / SAFETY
P.3
Page 5
7. Lightning
For added protection of this amplier during lightning storms, or when it is
left unattended and unused for long periods of time, unplug it from the wall
outlet. This will prevent damage to the amplier due to lightning and power-
SAFETY
line surges. Disconnection from the mains power supply can only be achieved
by removing the plug from the mains socket and by external disconnecting all
poles from the mains.
8. Interference of external objects and/or liquids with the appliance
Never push objects of any kind into this amplier through openings as they may
touch dangerous voltage points or short out parts that could result in a re or
electric shock. Never spill liquid of any kind on the amplier.
9. Accessories
Do not place this amplier on an unstable cart, stand, tripod, bracket, or table.
The amplier may fall, causing serious injury, and serious damage to the product.
Any mounting of the amplier should follow the manufacturers instructions,
and should use a mounting accessory recommended by the manufacturer.
10. Connecting
When you connect the amplier to other equipment, turn off the power and
unplug all of the equipment from the supply source. Failure to do so may cause
an electric shock and serious personal injury. Read the user manual of the other
equipment carefully and follow the instructions when making the connections.
11. Sound Volume
Reduce the volume to minimum before you turn on the amplier to prevent
sudden high levels of noise which may cause hearing or speaker damage. (See
also 4.1.1 Volume control)
12. Damages that require service
Unplug this amplier from the mains supply and refer to your dealer/distributor
or other authorised repair workshop if any of the following situations occur:
if liquid has been spilled, or objects have fallen into the amplier.
if the amplier does not operate normally as described in the user manual.
Operate the controls only as described in the user manual.
if the amplier has been dropped or damaged in any other way.
when the amplier exhibits a distinct change from its normal function or
performance.
13. Servicing
Do not attempt to service this amplier yourself. As opening or removing covers
may expose you to dangerous voltage or other hazards, the amplier may only
be opened by qualied personnel. Please refer to your dealer/distributor.
14. Servicing and Replacement Parts
All service and repair work must be carried out by a CAMCO authorised dealer.
When replacement parts are required, please ensure that the dealer/distributor
only uses replacement parts specied by the manufacturer. The use of unauthorized replacement parts may result in injury and/or damage through re
or electric shock or other electricity-related hazards.
15. Safety Check
Upon completion of any service or repairs to this product, ask the dealer/
distributor to perform safety checks to determine that the amplier is in proper
operating condition.
Recommendations on how to carry out the safety test can be found in DIN VDE
0701-1 “Maintenance, Modication and Test of Electronic Appliances“.
USER MANUAL
TECTON POWER AMP SERIES
P.4
Page 6
EC Declaration of Conformity in accordance to EC Directives:
electro-magnetic compatibility (Council Directive 89/336/EEC,
as amended by Directives 92/31/EEC and 93/68/EEC);
low-voltage electrical equipment (Council Directive 73/23/EEC )
Manufacturers Name:
CAMCO Produktions- und Vertriebs- GmbH
für Beschallungs- und Beleuchtungsanlagen
Manufacturers Address:
Fischpicke 5, 57482 Wenden – Germany
Declares that the product with the model name:
CAMCO Power amplier TECTON-38.4, 32.4, 24.4, 28.2, 22.2 and 14.2
Conforms to the following standards:
EN60065 Security
EN55103-1 Emission
EN55103-2 Immunity
The operating conditions and application environments presupposed in the
information for use (user manual) are to be kept accordingly.
Please Note: The following formulations have been chosen: TECTON-38.4, TECTON-32.4, TECTON-24.4, TECTON-28.2, TECTON-22.2 and TECTON-14.2
for the type plate and the EC Declaration of Conformity. TECTON 38.4, TECTON
32.4, TECTON 24.4, TECTON 28.2, TECTON 22.2 and TECTON 14.2 for the front
face of the appliance and for the text in the user manual.
Wenden, 09.12.2004
Joachim Stöcker
USER MANUAL
TECTON POWER AMP SERIES
EC DECLARATION OF CONFORMITY
P.5
Page 7
CONTENTS
USER MANUAL
TECTON POWER AMP SERIES
P.6
P.2
IMPORTANT SAFETY INSTRUCTIONS
P.3
EXPLANATION OF SYMBOLS / SAFETY
P.5
EC DECLARATION OF CONFORMITY
P.6
CONTENTS
P.7
1 WELCOME
1.1 Welcome to CAMCO
1.2 Unpacking
P.8
1.3 The Amplier
P.9
2 FACILITIES
2.1 TECTON – The Front
2.2 TECTON – The Rear
P.10
2.3 Factory Settings
P.11
3 INSTALLATION
3.1 Mains Supply
P.12
3.2 On/Off Switch
3.3 Mounting
P.13
3.4 Cooling
3.5 Ground Lift
3.6 Mode Indicators
P.14
3.7 Mode Selector
3.8 Wiring
3.8.1 E.U.I.2 and XLR Connection
P.15
3.8.2 Stereo Operation
3.8.3 Parallel-Mono Operation
3.8.4 Mono-Bridge Operation
P.16
3.8.5 SPEAKON Connection
P.17
4 OPERATION
4.1 Controls
4.1.1 Volume Control
4.1.2 Gain Selector
4.1.3 Gain and Input Sensitivity
4.1.4 Limiter Switch
4.1.5 HPF-Filter
P.18
4.2 Indicators
4.2.1 Output Current LEDs
4.2.2 Signal LEDs
4.2.3 Clip LEDs
P.19
4.3 Power Amp Protection Systems
4.3.1 Clip Limiter
4.3.2 SOA Protection
4.3.3 DC Protection
4.3.4 DC Servo
4.3.5 Over Current Protection
4.3.6 Thermal Protection
4.4 Mains Protections
P.20
4.4.1 Inrush Current Limitation
4.4.2 Mains Over Voltage Detection
4.4.3 Mains Failure Detection
4.4.4 Fuse Protection
4.5 Main SMPS Protections
4.5.1 Over Current Protection
4.6 Fans
5 OPTIONS
P.21
5.1 E.U.I.2 (Extended User Interface)
5.1.1 What Are The Possibilities
Using the E.U.I.2
6 TROUBLESHOOTING
P.22
6.1 Problem: No Sound
6.2 Problem: No Channel Separation
6.3 Problem: Distorted Sound
6.4 Problem: Hiss
6.5 Problem: Squeals and Feedback
7 SPECIFICATION
P.23
8 MEASUREMENTS
P.26
P.31
9WARRANTY INFORMATION
9.1 Summary Of Warranty
9.2 Items Excluded From This Warranty
9.3 What CAMCO Will Do
9.4 How To Obtain Warranty Service
9.5 CAMCO’s Product Improvement
P.32
10 SERVICE INFORMATION
P.33
11 MAINTENANCE INFORMATION
12 DECOMISSIONING
P.34
COMPANY INFORMATION
Page 8
1.1 Welcome to CAMCO
Established in 1983, CAMCO has gained worldwide experience with professional
sound reinforcement technology. Within the audio market, CAMCO specialises
in the production and marketing of high quality power ampliers and sound
systems for use both on tour and in static installations.
The success of the LA, DL, DX and VORTEX series of power amps has made the
CAMCO name synonymous with professional quality, high performance and
utterly reliable power amps.
1.2 Unpacking
Please unpack and inspect your new amplier for any damage that may have
occurred during transit. If damage is found, notify the transportation company
immediately. Only you, the consignee, may initiate a claim for shipping damage.
CAMCO will be happy to cooperate fully as needed. Please save the shipping
carton as evidence of damage for the shipper’s inspection.
Even if the amplier has arrived in perfect condition, save all packing materials
so you will have them if you ever need to transport the unit.
1 WELCOME
CAMCO’s commitment to research and development, seen not just in the area
of materials and technology but also most importantly in its highly skilled and
motivated workforce, is one of the keys to its ongoing success.
Welcome to the new world of professional power ampliers –
WELCOME TO CAMCO!
NEVER SHIP THE AMPLIFIER WITHOUT THE ORIGINAL
PACKING MATERIALS.
When shipping the TECTON amplier, always use the original shipping carton
and packing materials. For maximum protection, repack the unit as it was originally packed at the factory.
USER MANUAL
TECTON POWER AMP SERIES
P.7
Page 9
1.3 The Amplier
The TECTON is a Class-H power amplier with a power output of:
TECTON 38.4 1900 W per channel @ 4 Ω
TECTON 32.4 1600 W per channel @ 4 Ω
1 WELCOME
TECTON 24.4 1200 W per channel @ 4 Ω
TECTON 28.2 1420 W per channel @ 2 Ω
TECTON 22.2 1140 W per channel @ 2 Ω
TECTON 14.2 730 W per channel @ 2 Ω
3800 W in Mono-Bridge @ 8 Ω
3800 W in Parallel-Mono @ 2 Ω
3200 W in Mono-Bridge @ 8 Ω
3200 W in Parallel-Mono @ 2 Ω
2400 W in Mono-Bridge @ 8 Ω
2400 W in Parallel-Mono @ 2 Ω
2840 W in Mono-Bridge @ 4 Ω
2840 W in Parallel-Mono @ 1 Ω
2280 W in Mono-Bridge @ 4 Ω
2280 W in Parallel-Mono @ 1 Ω
1460 W in Mono-Bridge @ 4 Ω
1460 W in Parallel-Mono @ 1 Ω
TECTON ampliers are tted with Switched Mode Power Supplies (SMPS), which
signicantly reduces the weight and size (only 2U) of the amplier. Using SMPS,
the 2 symmetrical supply voltages (1 symmetrical supply voltage for TECTON
22.2 and TECTON 14.2) of the power amplier are more stable than the power
supplies used in conventional ampliers.
The TECTON has been designed as an intelligent and powerful product for
performing specialised tasks within a complex audio system. Users can adapt
the power amp to meet their specic audio requirements before use. Controls
mounted on the front and the rear of the TECTON allow access to the functionality.
Since some of the externally mounted controls have multiple functions, it is
important that users should familiarise themselves thoroughly with the entire
range of controls.
If you have any questions regarding features and/or functions of your TECTON, CAMCO will be pleased to provide you with further information. Alternatively,
contact your dealer or distributor.
USER MANUAL
TECTON POWER AMP SERIES
P.8
Page 10
5 76
2 FACILITIES
2.1 TECTON – The Front
1 On/Off Switch
2 Volume Control – Channel A
3 Volume Control – Channel B
4 Operating Mode LEDs (multifunctional)
5 Clip LEDs
6 Output Current LEDs
7 Signal LEDs (multifunctional)
1415121110
19201718
16
2.2 TECTON – The Rear
8 AC Power Cable
9 Cooling Air Outlet Vents
10 Input Ground Lift Switch
11 High Pass Filter B
12 Mode Selector
13 Clip Limiter Switch
13
14 High Pass Filter A
15 Gain Selector
16 Extended User Interface
(E.U.I. 2)
17 XLR – Line Input B
18 XLR – Line Input A
2221
OUTPUT BOUTPUT A
19 XLR – Line Link B
20 XLR – Line Link A
21 SPEAKON Outlet B
22 SPEAKON Outlet A
23 Rating Plate
23
89
1324
USER MANUAL
TECTON POWER AMP SERIES
P.9
Page 11
2.3 Factory Settings
TECTON ampliers are delivered with the following factory settings
2 FACILITIES
Front panel:
On/Off Switch Off Amplier is switched off
10
11
12
15
14
13
16
18
17
20
19
Rear panel:
10 Input Ground Lift Grounded
11 High Pass Filter channel B Off
12 Mode Selector Stereo
13 Limiter Off
14 High Pass Filter channel A Off
15 Gain Selector 26 dB
Make sure that the switches are set to the conguration needed for each particular application. For more detailed information, see sections 3.5, 3.7 and 4.1.
P.10
USER MANUAL
TECTON POWER AMP SERIES
Page 12
TECTON-22.2
230 V ~ 50/60 Hz 10,6 A 1120 W
1100 W / 2 Ohm
xxxxxxx
TECTON-24.4
230 V ~ 50/60 Hz 10,5 A 1060 W
1600 W / 2,7 Ohm
xxxxxxx
TECTON-28.2
230 V ~ 50/60 Hz 9,5 A 1002 W
1400 W / 2 Ohm
xxxxxxx
TECTON-32.4
230 V ~ 50/60 Hz 9,8 A 1010 W
1600 W / 4 Ohm
xxxxxxx
TECTON-14.2
230 V ~ 50/60 Hz 7,4 A 712 W
700 W / 2 Ohm
xxxxxxx
TECTON-38.4
230 V ~ 50/60 Hz 11,3 A 1220 W
1900 W / 4 Ohm
xxxxxxx
3.1 Mains Supply
When mounting or connecting the amp always disconnect it from mains.
Only connect the TECTON amplier to a appropriate AC circuit and outlet,
according to the requirements indicated in the second line on the rating
plate.
Exemplary rating plates for a mains supply of 230 V AC 50/60 Hz.
Power supply data:
Voltage Mains Frequency Current Power Consumtion
TECTON-38.4 120 V50/60 Hz22,6 A1220 W
TECTON-38.4 220 V60 Hz11,3 A1220 W
TECTON-32.4 120 V50/60 Hz19,6 A1010 W
TECTON-32.4 220 V60 Hz9,8 A1010 W
TECTON-28.2 120 V50/60 Hz19 A1002 W
TECTON-28.2 220 V60 Hz9,5 A1002W
TECTON-24.4 120 V50/60 Hz21 A1060 W
TECTON-24.4 220 V60 Hz10,5 A1060 W
TECTON-22.2 120 V50/60 Hz21 A1120W
TECTON-22.2 220 V60 Hz10,6 A1120 W
TECTON-14.2 120 V50/60 Hz14,8 A712 W
TECTON-14.2 220 V60 Hz7,4 A712 W
NOTE: Even under normal conditions the mains current can reach levels
up to 60 A (230 V) and 120 A (120 V), respectively; this could cause lamps
to icker if connected to the same mains as the amp. The impedance of
the AC circuit should be less than 0,157 Ohms to avoid icker according
to EN61000-3-11 “Electromagnetic compatibility – Part 3-11: Limits
– Limitation of voltage changes, voltage uctuations and icker in the
public low-voltage supply systems – Equipment with rated current more
than 75 A and subject to conditional connection”. If in any doubt, consult
your local power provider. Never attempt to measure this impedance level
with your ohmmeter. This may damage your meter and expose you to the
risk of electric shock!
3 INSTALLATION
USER MANUAL
TECTON POWER AMP SERIES
P.11
Page 13
3.2. On/Off Switch
The On/Off Switch is a rocker-type switch. It is located on the right side of the
front panel.
To turn the amplier on, push in on the upper part of the switch. This initiates
start-up by activating the inrush current limiter.
During power up the Clip and Signal LEDs from both channels will light up in
red for a few seconds.
To turn the amplier off, push in on the lower part of the switch.
3 INSTALLATION
Amplier is switched on Amplier is switched off
NOTE: This switch does NOT disconnect the amplier from mains.
Make sure the mains power socket or an alternative disconnect device is
near by and easily accessible.
3.3 Mounting
Use four screws and washers when mounting the amplier to the front rack rails.
For mobile use, the amplier should also be secured using the 19” mounting
elements on the rear panel.
10 mm
7 mm
7 mm
76,2 mm
88,9 mm
76,2 mm
466 mm
442 mm
10 mm
P.12
The switch initiates start-up by activating the current limiting function.
As soon as the power amplier is connected to the mains power supply, a voltage is supplied to both the line-lter and the fused input of the controllable
rectier. Disconnecting the amplier from the main power supply can only be
achieved by physically separating the amplier from the mains by pulling the
mains plug. The mains plug therefore has to be freely accessible. Disconnect
the mains plug from the mains during a lightning storm or when the amplier
remains unused or unsupervised for a prolonged period of time. Alternatively,
you can disconnect the amplier via an external all-pole disconnection from
the mains.
If a power cut occurs while the amplier is switched on, it will restart automatically once the power supply has been restored. All settings operation prior to
the loss of power will be maintained.
USER MANUAL
TECTON POWER AMP SERIES
330,7 mm
356,2 mm
347,2 mm
Page 14
3.4 Cooling
Under normal operation of the power amp, overheating should never be a
problem. The air is taken in from the front and out through the back, it is of
course essential that while the power amp is running air is able to circulate
around it freely.
The efciency of the cooling will depend on the immediate environment (e.g.
an enclosed rack, direct sunlight). If the amp is installed in a case, the open area
at the back of the case must be at least 140 cm². This area should be in line with
the amp.
If this can not be achieved a forced ventilation system has to be used.
3.5 Ground Lift
The input signal ground (pin 1 for all 4 XLRs) is connected to the ground of the
mains supply. In order to avoid ground loops, this connection can be separated
via a resistor. The ground potential of the power amp and the ground of the
loudspeaker always remain connected to the ground of the mains supply
regardless of the setting of this switch.
3.6 Mode Indicators
On the front panel there are two yellow LEDs to indicate the mode that is set. In
stereo mode (2-channel) none of them will be lit. In Parallel-Mono the (PM) LED
will be lit and in Mono-Bridge, the (MB) LED will be lit.
3 INSTALLATION
Amplier in Parallel-Mono mode Amplier in Mono-Bridge mode
Lift Position
to Pin 1
of the XLRs
Removing or taping the mains connector ground is illegal and dangerous.
Ground Position
DO NOT REMOVE MAINS CONNECTOR GROUND
IT IS ILLEGAL AND DANGEROUS
USER MANUAL
TECTON POWER AMP SERIES
P.13
Page 15
3.7 Mode Selector
The switch on the rear panel changes the operating mode. Switch the power
switch to the Off position to make changes on the Mode Selector. When the
amplier is switched on again, the selected mode will operate.
3.8 Wiring
3.8.1 E.U.I. and XLR Connection
XLR: Pin 1 = Ground (or lifted via 15 Ω resistor) (See 3.5 Ground Lift)Pin 2 = Hot (inphase)
Pin 3 = Cold (out of phase)
Always use symmetrical (balanced) shielded cable to connect the amplier.
3 INSTALLATION
P.14
USER MANUAL
TECTON POWER AMP SERIES
Channel B
To
Channel B
Input
Channel A
12
3
2
To
Channel A
Input
Ground
Lift
1
3
LINK BInput
1
22
3
Input Ground Lift in position:
grounded
LINK A
1
3
Page 16
3.8.2 Stereo Operation, 2 Channel Operation
Two fully independent amplier channels (normal operating mode).
3.8.3 Mono-Bridge Operation
One-channel mono bridged operation.
TECTON
A (L)
Z ≥ *Z
min
B (R)
Z ≥ *Z
min
3.8.3 Parallel-Mono Operation
Parallel operation of the two channels together.
TECTON
A
Z
res
≥ 0.5 *Z
min
The output terminals of the two channels are congured in parallel using an internal relay. The (single) load is connected either to the output of channel A or to
that of channel B (as if in stereo). While the total output of the amplier remains
the same and the output voltage level is also the same as in stereo operation,
the minimum impedance that can be connected is reduced by half due to the
fact that current capability is doubled. Only channel A-Input is active. The channel B-Input is inactive – turn the volume of channel B down to zero.
This mode is useful when, for example, 3 identical loudspeakers are to be
operated with the same power.
TECTON
A
Z ≥ 2 *Z
min
The second channel processes the same input signal, but with reversed phase.
The (single) load is connected between the two positive channel outputs using
a suitable connected SPEAKON connector. While the total output of the amplier remains the same, both the available output voltage and the minimum
impedance that can be connected are doubled, as compared with stereo operation. Only channel A-Input is active. A signal feeding channel B will have no
effect on the output. Turn the volume of channel B down to zero.
WARNING !
In Mono-Bridge mode RMS output voltages are as high as 230 V. Wiring
to the speaker loads must conform to NEC Class 3 safety standards or its
aquivalent that meets all national and local electric codes.
All customer specic cables may only be manufactured by qualied
suppliers/personnel. All cabling or rewiring work must be carried out by
qualied personnel.
* Z
= 2 Ω for TECTON 28.2, 22.2 and 14.2
min
* Z
= 4 Ω for TECTON 38.4, 32.4 and 24.4
min
USER MANUAL
TECTON POWER AMP SERIES
3 INSTALLATION
P.15
Page 17
3.8.5 SPEAKON Connection
Both SPEAKON connectors are connected to channel A and channel B outputs.
The pin conguration of the SPEAKON connectors is as follows:
Output A: Pin 1+ Channel A signal
(View at the back)Pin 1- Channel A ground
Pin 2+ Channel B signal
Pin 2- Channel B ground
4 OPERATION
Output B: Pin 1+ Channel B signal
(View at the back)Pin 1- Channel B ground
Pin 2+ Channel A signal
Pin 2- Channel A ground
WARNING !
SPEAKON connectors marked with the lightning ash indicate high voltages that are potentially life threatening.
Wiring to these terminals requires installation by an instructed person or
the use of ready-made leads or cords.
Custom wiring should only be made by qualied personnel.
To prevent electric shock, do not operate the amplier with any of the conductor portion of the speaker wire exposed.
P.16
Input
Channel A
Input
Channel B
USER MANUAL
TECTON POWER AMP SERIES
Output A
Output B
NOTE:
For reasons of safety and performance, use only high-quality fully insulated speaker cables of stranded copper wire. Use the largest wire size that
is economically and physically practical, and make sure the cables are no
longer than necessary.
IMPORTANT:
When connecting speaker cabinets in parallel, always use all the contacts
in both SPEAKON connectors. If not, this may cause permanent damage to
the connectors and considerably reduce performance.
Page 18
4.1 Controls
4.1.1 Volume Control
A volume control with 41 notched settings controls the audio signal. These
settings have been selected to correspond to human hearing characteristics
(logarithmically) and therefore guarantee an optimal range of settings for practical applications. Each channel can be set individually except when operating
in mono modes whereby only channel A is active.
Set the volume to zero before turning on the amplier to prevent the occurrence of sudden high volume levels which may cause damage to your hearing
and/or the speakers.
4.1.2 Gain Selector
A switch on the rear of the TECTON allows the maximum amplication attainable to be set directly in the input stage.
The TECTON amplier has a 26 dB and 32 dB
voltage gain setting along with a 1,4 V sensitivity
setting.
4.1.3 Gain and Input Sensitivity
The table shows input sensitivity per channel for a given gain and load. It also
shows the gain for the 1,4 V input sensitivty.
Model26 dB32 dB 1,4 V
38.4
32.4
24.4
28.2
22.2
14.2
4.1.4 Limiter Switch
This switch is located at the rear of TECTON. It allows you to set the mode of the
limiter. There are three modes. (See 4.3.1 Clip Limiter)
Right position: Middle position: Left position:
Clip Limiter: Fast Clip Limiter: Slow Clip Limiter: Off
Attack fast Attack slow
4 Ω @1900 W
8 Ω @ 1100 W
4 Ω @ 1600 W
8 Ω @ 915 W
4 Ω @ 1200 W
8 Ω @ 700 W
2 Ω @ 1420 W
4 Ω @ 920 W
2 Ω @ 1140 W
4 Ω @ 660 W
2 Ω @ 730 W
4 Ω @ 420 W
4,37 V
4,70 V
4,01 V
4,29 V
3,47 V
3,75 V
2,67 V
3,04 V
2,39 V
2,58 V
1,92 V
2,05 V
2,19 V
2,36 V36,52 dB
2,01 V
2,15 V35,72 dB
1,74 V
1,88 V34,56 dB
1,34 V
1,52 V32,74 dB
1,20 V
1,29 V31,29 dB
0,96 V
1,03 V29,33 dB
4 OPERATION
USER MANUAL
TECTON POWER AMP SERIES
P.17
Page 19
4.1.5 HPF Filter
(Channel A as example)
Left position: Middle position: Right position:
4 OPERATION
HPF: Off HPF: 30 Hz HPF: 50 Hz
HPF OFF
HPF 30 Hz
4.2 Indicators
4.2.1 Output Current LEDs
The brightness is proportional to the output current in the channel. Output
current of approx. 1 A lights up the LED at its lowest brightness level, while full
brightness corresponds to the maximum rated current.
P.18
USER MANUAL
TECTON POWER AMP SERIES
HPF 50 Hz
Low frequency response curves
4.2.2 Signal LEDs (multifunctional)
The channels Signal LED is illuminated green when the voltage level at the
output reaches approx. 4 V; this corresponds to a power of approx. 4 W at an
impedance of 4 Ohms. The channels Signal LED is illuminated red while the Amp
is in Protect Mode (Mute).
Page 20
4.2.3 Clip LEDs
If the power level is overloaded, the Clip LED will light up.
4.3.3 DC Protection
Each output of the power amp is constantly monitored for persistent DC voltage
levels. If the 3 V thresholds are exceeded at any of the outputs, the corresponding channel will be muted. If DC was only applied for a short moment, the amplier will realase mute and work as normal. If DC is applied for longer periodes or
several short times the amplier will switch to stand by mode.
Switch off the amplier, wait until the power LED stops ashing and switch the
amplier on again.
4.3.4 DC Servo
To prevent DC Offset at the speaker output the TECTON is tted with a DC
Servo.
4 OPERATION
4.3 Power Amp Protection Systems
4.3.1 Clip Limiter
If the power amp is overdriven, the clip detection triggers the Attack-ReleaseCircuit (ARC). The ARC delivers the control voltage for the gain reduction. Two
different attack modes (fast and slow) could be chosen with the Clip Limiter
switch (see4.1.4 Limter Switch).
4.3.2 SOA Protection
Whenever the power transistors leave their Safe Operation Area (SOA), the
SOA-protection in stereo mode switches back the current rail of the respective
channel. In mono modes the rails of both channels are switched back.
4.3.5 Over Current Protection
Over current is permanently controlled in the output stage. There are two limiting levels of over current depending on output voltage. These limits will be set
automatically. This improves reliability without degrading sound quality when
driving complex loads.
4.3.6 Thermal Protection
There are several sensors in the amp in order to ascertain temperature data. If
a temperature of more than 85 °C is detected at the heat sinks, the input signal
on that channel is reduced. If the temperature exceeds 100 °C, the main SMPS
is switched off.
USER MANUAL
TECTON POWER AMP SERIES
P.19
Page 21
4.4 Mains Protections
4.4.1 Inrush Current Limitation
Within 2 seconds of the amplier being switched on, the inrush current limiter
will increase mains current from nearly zero to nominal value. This value depends
on program material, output level and speaker loads.
4.4.2 Mains Over Voltage Detection
Mains over voltage detection is always operative. When the mains voltage
4 OPERATION
exceeds approx. 267 V (230 V operation) or 134 V (120 V operation), the amplier will be switched off. The system will try to start in intervalls and will return
with a soft start when the regular mains voltage returns.
4.4.3 Mains Failure Detection
Mains failure detection is always operative. When the mains supply is interrupted for about 2 mains cycles, the amplier will be switched off. When the
mains voltage returns to a normal value, a soft start occurs.
4.4.4 Fuse Protection
The average mains current can peak temporarily, depending on the load impedance and type of signal, at values signicant higher than the nominal value
allowed by the fuse protection.
Continuous monitoring of the fuse protection status allows the conditions that
would trigger the fuse protection to be predicted. In order to avoid shut-down
of the amplier due to current overload, the amplitude of the input signals will
be limited and by hard overloads the amp will be muted for the time.
4.5 Main SMPS Protections
4.5.1 Over Current Protection
Main SMPS (Switched Mode Power Supply) transformer current is continuously
monitored. If over current occurs, the main SMPS immediately stops working.
Should there be an internal failure, this feature prevents other parts being
damaged.
4.6 Fan
The fan mounted in the TECTON operates permanently, but as long as the
temperature remains below 40 °C it runs at its slowest speed and can hardly
be heard. The highest detected temperature from either channel controls the
speed of the fan: above 40 °C the speed is increased until it reaches its maximum
value.
P.20
USER MANUAL
TECTON POWER AMP SERIES
Page 22
5.1 E.U.I.2 (Extended User Interface)
CAUTION! Always switch off and unplug the TECTON from mains, before
making alterations to the E.U.I. card.
The E.U.I. card contains the Rear XLR Panel as standard. Other input cards are
available (See 5.1.1 What Are The Possibilities Using The E.U.I.2?).
To remove the E.U.I.2 unscrew the two Phillips head screws at the left and right
end of the XLR-Panel and carefully slide out the E.U.I.2.
To ret the E.U.I.2, carefully insert it. Pay attention that the cable is not clamped.
ATTENTION! Don’t forget to tighten the screws!
5.1.1 What Are The Possibilities Using The E.U.I.2?
The E.U.I.2 is a very powerful interface, which allows access to most of the
system parameters, such as volume, input signal, mute, output current, clip
signal, temperature and more. You can use the E.U.I.2 as a lter, remote control,
signal processing device and more… Please contact your dealer/distributor or
CAMCO to customise the E.U.I.2 according to your wishes.
5 OPTIONS
USER MANUAL
TECTON POWER AMP SERIES
P.21
Page 23
6.1 Problem: No Sound
Indication:
Indication:
6 TROUBLESHOOTING
Indication:
Indication:
6.2 Problem: No Channel Separation
Signal LEDs not lit
Clip LEDs not lit
Check AC plug.
Conrm that AC outlet works by plugging in another device.
Output Current LEDs are lit
Signal LEDs not lit
Make sure the signal source is operating and try another cable.
Check position of volume pots.
Output Current LEDs are lit
Signal LEDs responding to signal level
Check the speaker wiring for breaks.
Try another speaker and cable.
Signal LEDs show red (Protect Mode)
Overheating will cause protective muting. Check for proper ventilation.
If the fan isn’t running the amplier requires servicing.
Check the mode indicators on the front panel and make sure the mode
selector on the rear panel is in the stereo-position.
Make sure other equipment in the signal path such as mixers and preamps
are set for stereo, not mono.
6.3 Problem: Distorted Sound
Indication:
Output Current LEDs are lit
Signal LEDs responding to signal level
Clip LEDs not lit
A faulty speaker or a loose connection could cause this. Check the wiring
and try another speaker.
The signal source might be clipping. Keep the TECTON volume pots at
least halfway up so that the source does not have to be overdriven.
Keep the TECTON volume pots at least halfway up and try changing input
sensitivity from 1,4 V to 32 dB or 26 dB with the gain selector on the rear.
6.4 Problem: Hiss
Unplug the amplier input to conrm that the hiss is coming from the
source or from a device upstream. Erratic or popping noises indicate an
electronic fault in the offending unit.
To keep the noise oor low, operate the primary signal source at full level,
without clipping.
Avoid boosting the signal further between the source and the amplier.
6.5 Problem: Squeals and Feedback
Microphone feedback should be eliminated with mixer controls. If noise
continues to build up with no microphone gain, there is a serious fault
in the signal processors or cables. Working in succession from the signal
source towards the amplier and check each device in the signal path by
reducing its gain or by unplugging it.
P.22
USER MANUAL
TECTON POWER AMP SERIES
Page 24
Output Power
TECTON 38.4
1 kHz, THD ≤ 1 %, in mono-bridge mode
1 x 3800 W @ 8 Ω
1 x 2200 W @ 16 Ω
1 kHz, THD ≤ 1 %, both channels driven
Duration limited by fuse / thermal protection for RL < 8 Ω
in stereo mode or RL < 16 Ω in mono-bridge mode.
2 x 1900 W @ 4 Ω
2 x 1100 W @ 8 Ω
1 kHz, THD < 0,1 %, both channels driven
2 x 1800 W @ 4 Ω
2 x 1070 W @ 8 Ω
CircuitryBipolar, Class H 2-step
high efciency circuit
Signal to Noise-Ratio
20 Hz - 20 kHz, 8 Ω load, unweighted
A-weighted
Power Consumption @ 230 V
(both channels driven)
>112 dB
>116 dB
Typical1)Max
Idle1,4 A
2)
60 W
4,8 A
16 Ω
410 W
7,3 A
8 Ω
700 W
11,3 A
4 Ω
1220 W
Multiply currents by 2 for 120 V
2)
1)
1/8 of max Output Power with pink noise to represent typical music signal
max. rated Output Power (see above)
14,8 A
1600 W
25 A
3000 W
40 A
5230 W
TECTON 32.4
1 x 3200 W @ 8 Ω
1 x 1800 W @ 16 Ω
2 x 1600 W @ 4 Ω
2 x 915 W @ 8 Ω
2 x 1500 W @ 4 Ω
2 x 860 W @ 8 Ω
Bipolar, Class H 2-step
high efciency circuit
>111 dB
>115 dB
Typical1)Max
Idle1,3 A
55 W
3,9 A
16 Ω
330 W
6,2 A
8 Ω
580 W
9,8 A
4 Ω
1010 W
12,2 A
1280 W
21 A
2410 W
34 A
4300 W
1 x 2400 W @ 8 Ω
1 x 1400 W @ 16 Ω
2 x 1600 W @ 2,7 Ω
2 x 1200 W @ 4 Ω
2 x 1135 W @ 4 Ω
Bipolar, Class H 2-step
high efciency circuit
2)
Idle1,2 A
16 Ω
8 Ω
4 Ω
2,7 Ω
TECTON 24.4
2 x 700 W @ 8 Ω
2 x 655 W @ 8 Ω
>110 dB
>115 dB
Typical1)Max
50 W
3,9 A
250 W
5,2 A
460 W
7,9 A
790 W
10,5 A
1060 W
7 SPECIFICATION
2)
9,9 A
1000 W
16,5 A
1840 W
27 A
3230 W
36 A
4600 W
USER MANUAL
TECTON POWER AMP SERIES
P.23
Page 25
Output Power
TECTON 28.2
1 kHz, THD ≤ 1 %, in mono-bridge mode
1 x 2800 W @ 4 Ω
1 x 1820 W @ 8 Ω
1 kHz, THD ≤ 1 %, both channels driven
Duration limited by fuse / thermal protection for RL < 8 Ω
in stereo mode or RL < 16 Ω in mono-bridge mode.
1 kHz, THD < 0,1 %, both channels driven
2 x 1400 W @ 2 Ω
2 x 910 W @ 4 Ω
2 x 1310 W @ 2 Ω
2 x 860 W @ 4 Ω
7 SPECIFICATION
CircuitryBipolar, Class H 2-step
high efciency circuit
Signal to Noise-Ratio
20 Hz - 20 kHz, 8 Ω load, unweighted
A-weighted
Power Consumption @ 230 V
(both channels driven)
>108 dB
>113 dB
Typical1)Max
Idle1,2 A
8 Ω
360 W
4 Ω
611 W
2 Ω
1002 W
Multiply currents by 2 for 120 V
2)
1)
1/8 of max Output Power with pink noise to represent typical music signal
max. rated Output Power (see above)
45 W
4,2 A
6,5 A
9,5 A
13,1 A
1380 W
21 A
2490 W
33 A
4220 W
1 x 2200 W @ 4 Ω
1 x 1320 W @ 8 Ω
2 x 1100 W @ 2 Ω
2 x 660 W @ 4 Ω
2 x 1040 W @ 2 Ω
2 x 620 W @ 4 Ω
Bipolar, Class AB
high efciency circuit
2)
Idle1,4 A
8 Ω
4 Ω
2 Ω
TECTON 22.2
>105 dB
>111 dB
Typical1)Max
60 W
4,3 A
370 W
6,8 A
640 W
10,6 A
1120 W
10,1 A
1020 W
16,8 A
1870 W
27 A
3320 W
high efciency circuit
2)
Idle1,2 A
8 Ω
4 Ω
2 Ω
TECTON 14.2
1 x 1340 W @ 4 Ω
1 x 800 W @ 8 Ω
2 x 670 W @ 2 Ω
2 x 400W @ 4 Ω
2 x 610 W @ 2 Ω
2 x 380 W @ 4 Ω
Bipolar, Class AB
>98 dB
>108 dB
Typical1)Max
50 W
3,3 A
250 W
4,7 A
420 W
1180 W
7,4 A
712 W
2130 W
2)
6,8 A
660 W
10,9 A
17,3 A
P.24
USER MANUAL
TECTON POWER AMP SERIES
Page 26
Frequency Response 20 Hz - 20 kHz ± 0,15 dB
Input Impedance 14 kΩ balancedVoltage Gain selectable: 26 dB, 32 dB, or 1,4 V input sensitivityProtection Circuits inrush-current limitation, temperature monitoring of transformer and heat-sinks,
Limiter switchable clip limiterFan temperature dependent speed-controlled axial fanGround Lift input ground lift switch on back panelIndicators LEDs for Mode, Signal, Clip, Output Current and faults for example like DCInput Connectors 3-pin XLR, male and female per channel, pin 2 = inphase (hot)Output Connectors one 4-pole SPEAKON connector for each output channel (bi-amping possible) Modes of Operation Stereo, Mono-Bridge and Parallel-MonoOptions Extended User Interface / E.U.I. 2 – modules for any kind of EQTHD+N (typical) < 0,01 %
20 Hz - 10 kHz, 8 Ω load,
10 dB below rated power
SMPTE (typical) < 0,01 %
8 Ω load,
10 dB below rated power
Damping Factor > 400
8 Ω load, 1 kHz and below
Dimensions (WxHxD) 483 x 88,9 x 330 mm (19”, 2U)Net Weight 9,4 kgShipping Dimensions (WxHxD) 540 x 135 x 540 mm (0,04 m3)
Shipping Weight 11 kg
8 Ω load, 10 dB below rated power
output DC protection, power transistor SOA protection, output over current protection,
mains fuses protection
Subject to technical alterations without prior notice
7 SPECIFICATION
USER MANUAL
TECTON POWER AMP SERIES
P.25
Page 27
8 MEASUREMENTS
P.26
+27
+26.5
+26
+25.5
+25
+24.5
+24
dBr
+23.5
+23
+22.5
+22
+21.5
+21
10100k2050 100 200500 1k 2k5k 10k 20k50k
+26
+24
+22
+20
+18
+16
dBr
+14
+12
+10
+8
+6
+4
+2
-0
1020k2050100 200500 1k2k5k10k
Gain vs. frequency / Different positons of HPF-Switch (Ch1, Ch2)
USER MANUAL
TECTON POWER AMP SERIES
Hz
Figure 8.1
Gain vs. frequency (Ch1, Ch2)
(Measurements of a typical performance)
Hz
Figure 8.2
(Measurements of a typical performance)
+180
+135
+90
+45
+0
deg
-45
-90
-135
-180
10100k2050 100 200500 1k 2k5k 10k 20k50k
Hz
Figure 8.3
Phase vs. frequency (Ch1, Ch2)
(Measurements of a typical performance)
+180
+135
+90
+45
deg
+0
-45
-90
-135
-180
1020k2050100 2005001k2k5k10k
Hz
Figure 8.4
Phase vs. frequency / Different positons of HPF-Switch (Ch1, Ch2)
SMPTE intermodulation distortion (60 Hz and 7 kHz) @ 8 Ω vs. input level
(Ch1, Ch2) (Measurements of a typical performance of TECTON 32.4)
USER MANUAL
TECTON POWER AMP SERIES
-20
-30
-40
-50
dBr
-60
-70
-80
-90
-100
2020k501002005001k2k5k10k
Hz
Figure 8.11
Common mode rejection ratio (Ch1, Ch2)
(Measurements of a typical performance of TECTON 32.4)
-10
-20
-30
-40
-50
dB
-60
-70
-80
-90
-100
-110
2020k501002005001k2k5k10k
Hz
Figure 8.12
Channel separation vs. frequency @ 10 W / 8 Ω (Ch1 => Ch2, Ch2 => Ch1)
(Measurements of a typical performance of TECTON 32.4)
Page 30
Watts
Watts
2500
2000
1500
2000
1500
1000
2275
1900
1225
1122
1000
500
0
4
Impedance/ Ω
8
Figure 8.13
TECTON 38.4(Measurements of a typical performance)
1800
1600
960
915
500
0
4
Impedance/ Ω
8
Figure 8.14
TECTON 32.4(Measurements of a typical performance)
16
483
16
608
630
Distortion limited
output power (1 % THD)
500
Distortion limited
output power (1 % THD)
Peak power
Peak power
Watts
Watts
1500
1000
1500
1000
1365
1212
730
695
500
0
4
Impedance/ Ω
8
Figure 8.15
TECTON 24.4(Measurements of a typical performance)
1440
1420
1008
920
500
0
2
Impedance/ Ω
4
Figure 8.16
TECTON 28.2(Measurements of a typical performance)
16
370
8
515
378
Distortion limited
output power (1 % THD)
534
Distortion limited
output power (1 % THD)
Peak power
Peak power
USER MANUAL
TECTON POWER AMP SERIES
8 MEASUREMENTS
P.29
Page 31
1500
1220
1133
1000
Watts
500
700
670
370
362
Peak power
8 MEASUREMENTS
0
2
Impedance/ Ω
4
8
Distortion limited
output power (1 % THD)
Figure 8.17
TECTON 22.2(Measurements of a typical performance)
P.30
1000
750
Watts
500
250
0
TECTON 14.2 (Measurements of a typical performance)
USER MANUAL
TECTON POWER AMP SERIES
2
700
756
Impedance/ Ω
417
4
435
Figure 8.18
230
8
233
Distortion limited
Peak power
output power (1 % THD)
Page 32
9.1 Summary Of Warranty
CAMCO guarantees the TECTON amplier to be free from defective material
and/or workmanship for a period of three (3) years from the date of sale. Provided that the amplier is returned to your dealer/distributor in a factory pack
with a copy of the proof of purchase, i.e., sales receipt, CAMCO will repair faulty
products under this warranty when a defect occurs under normal installation
and use.
This warranty provides that examination of the returned product must indicate,
in our judgment, a manufacturing defect.
9.2 Items Excluded From This Warranty
CAMCO is not liable for any damage caused by shipping accidents, misuse,
abuse, operation with incorrect AC voltage, operation with faulty periphal
equipment, modication, or alteration without prior factory approval, service by
an unauthorised service center, and normal wear and tear. Ampliers on which
the Serial Number has been removed or defaced are not eligible for warranty
service.
9.3 What CAMCO Will Do
CAMCO (or its appointed agent) undertakes to rectify any defect, regardless of
the reason for failure (unless excluded from this warrenty), by repair, replacement, or refund, as it sees t.
9.4 How To Obtain Warranty Service
You must notify your dealer/distributor of your need for warranty service.
All components must be shipped in the original packing.
9 WARRANTY INFORMATION
9.5 CAMCO’s Product Improvement
CAMCO reserves the right to improve the technical standard of its products
without giving prior notice. If in any doubt, please consult your dealer/distri-
butor or contact CAMCO directly for clarication.
USER MANUAL
TECTON POWER AMP SERIES
P.31
Page 33
PLEASE ENCLOSE THIS COMPLETED FORM WITH THE AMPLIFIER
To transport the amplier, the original packing materials must be used. Please
return the amplier to the following address or your nearest CAMCO appointed
distributor.
CAMCO Produktions- und Vertriebs- GmbH für Beschallungs- und Beleuchtungsanlagen, Fischpicke 5, D-57482 Wenden, Germany
USER MANUAL
TECTON POWER AMP SERIES
Nature Of Problem
Please describe the conditions that existed when the problem occured and what
attempts were made to correct it: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Our web site: www.camcoaudio.com provides a complete list of CAMCO
dealers/distributors.
Page 34
11 Maintenance Information
Cleaning and servicing the inside of the aplier must never carry out by unqualied personnel. The amplier must never be opened by unqualied personnel.
Cleaning and servicing work on the inside of the amplier must only be carried
out by qualied personnel.
Qualied personnel is dened as a person who has gained specialised relevant
knowledge of electronic engineering through education, training and experience and who has sufcient knowledge of all relevant governmental work
safety regulations to be in a position to judge the safe functioning of power
ampliers based on technical rules according to IEC 60065.
(IEC 60065 (DIN EN 60065) “Safety Requirements for Audio, Video or simlar
Electronic Appliances”)
In order to guarantee the safe functioning of the amplier, it has to be checked
at least once, depending on its application and usage, by a properly qualied
person.
Advice on how to carry out these checks can be found in DIN VDE 0702-1 “Safety
Checks for Electronic Appliances”.
An amplier that is considered to be unsafe must be labelled accordingly and
stored in a safe place to prevent this amplier being used mistakenly.
12 Decomissioning
During the decomissioning process of the amplier, all legally prescribed rules
and procedures must be adhered to.
USER MANUAL
TECTON POWER AMP SERIES
11 MAINTENANCE INFORMATION/12 DECOMISSIONING
P.33
Page 35
Mailing Address:
CAMCO Produktions- und Vertriebs- GmbH
für Beschallungs- und Beleuchtungsanlagen
Fischpicke 5
D-57482 Wenden
Germany
Telephone:
+49 (0) 27 62/4 08- 0
Facsimile:
+49 (0) 27 62/4 08- 10
Internet:
www.camcoaudio.com
COMPANY INFORMATION
Email:
postmaster@camco.de
P.34
USER MANUAL
TECTON POWER AMP SERIES
Page 36
NOTICES
Page 37
Page 38
www.camcoaudio.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.