IMPORTANT SAFETY INSTRUCTIONS
1) Read the information for use (user manual).
2) Please keep this user manual in a safe place during the lifetime of the ampli­er. The user manual forms an integral part of the amplier. Reselling of the amplier is only possible if the user manual is available. Any changes made to the amplier have to be documentated in writing and passed on to the buyer in the event of resale.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this amplier near water (for example, in damp rooms or near a swimming pool).
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with the user manual.
IMPORTANT SAFETY INSTRUCTIONS
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
9) Protect the power cord from being walked on, pinched or damaged in any other way. Pay particular attention to plugs and the point where they exit from the amplier.
10) The amplier may only be used in accordance with the information provided in the user manual. Before and during the usage of the amplier please ensure that all recommendations, especially the safety recommendations as detailed in the user manual, are adhered to. The TECTON-Amplier is designed for the amplication of pulsed audio signals and the amplier should only be connected to speakers with an average impedance that is not lower than the impedances specied in points 3.8.3, 3.8.4 and 3.8.5.
11) Do not place this amplier on an unstable cart, stand, tripod, bracket, or table. The device may fall, causing serious injury, and serious damage to the device itself.
12) The amplier can only be disconnected from the power supply by removing the plug, which must be freely accessible at all times. Unplug this amplier during lightning storms or when unused for long periods of time.
13) Refer all servicing to qualied service personnel. Servicing is required when
the power-supply cord or plug has been damaged,
liquid has been spilled or objects have fallen into the amplier,
the amplier has been dropped or damaged in any other way,
the amplier has been exposed to rain or moisture,
when the amplier exhibits a distinct change from its normal function or
performance.
USER MANUAL
TECTON POWER AMP SERIES
P.2
Page 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION – HIGH VOLTAGE HAZARDS
EXIST WITHIN THIS PRODUCT.
REFER ALL SERVICING TO
AUTHORISED PERSONNEL.
1. Read the information for use (user manual)
When shipping the TECTON amplier, always use the original shipping carton and packing materials. For maximum protection, repack the unit as it was origi­nally packed at the factory.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL, IS INTENDED TO
ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS
VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE.
THE EXCLAMATION MARK IS INTENDED TO ALERT THE USER
TO IMPORTANT INSTRUCTIONS ALSO FOR MAINTENANCE IN THE
LITERATURE ACCOMPANYING THE AMPLIFIER.
THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALERTS
THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE SPEAKON
CONNECTORS THAT COULD POTENTIALLY BE LIFE THREATENING.
CAUTION – RISK OF ELECTRIC SHOCK – DO NOT OPEN.
WARNING – TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS
AMPLIFIER TO RAIN OR MOISTURE.
THE AMPLIFIER MAY ONLY BE CONNECTED
TO A SOCKET WITH A CONNECTION TO GROUND.
2. Environments
Use this amplier only in E1, E2, E3 or E4 environments according to EN55103-2 “Electro-magnetic compatibility – Product-family norm for audio, video and audio-visual installations as well as for studio-and lighting-control installations for professional applications – Part 2: Immunity“.
3. Ventilation
Slots and openings in the cabinet are provided for ventilation, to ensure reliable operation of the amplier and to protect it from overheating. These openings must not be blocked or covered. This amplier should not be operated unless proper ventilation is provided or manufacturer’s instructions have been adhered to.
4. Water And Moisture
Do not use this amplier near water (for example, in a wet basement or near a swimming pool).
5. Cleaning
Unplug this amplier from the wall outlet before cleaning. Do not use liquid or aerosol cleaners.
6. Power-cord Protection
Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon them or against them, paying particular atten­tion to cords and plugs, and the point where they exit from the amplier.
USER MANUAL
TECTON POWER AMP SERIES
EXPLANATION OF SYMBOLS / SAFETY
P.3
Page 5
7. Lightning
For added protection of this amplier during lightning storms, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the amplier due to lightning and power-
SAFETY
line surges. Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket and by external disconnecting all poles from the mains.
8. Interference of external objects and/or liquids with the appliance
Never push objects of any kind into this amplier through openings as they may touch dangerous voltage points or short out parts that could result in a re or electric shock. Never spill liquid of any kind on the amplier.
9. Accessories
Do not place this amplier on an unstable cart, stand, tripod, bracket, or table. The amplier may fall, causing serious injury, and serious damage to the product. Any mounting of the amplier should follow the manufacturers instructions, and should use a mounting accessory recommended by the manufacturer.
10. Connecting
When you connect the amplier to other equipment, turn off the power and unplug all of the equipment from the supply source. Failure to do so may cause an electric shock and serious personal injury. Read the user manual of the other equipment carefully and follow the instructions when making the connections.
11. Sound Volume
Reduce the volume to minimum before you turn on the amplier to prevent sudden high levels of noise which may cause hearing or speaker damage. (See
also 4.1.1 Volume control)
12. Damages that require service
Unplug this amplier from the mains supply and refer to your dealer/distributor or other authorised repair workshop if any of the following situations occur:
if liquid has been spilled, or objects have fallen into the amplier.
if the amplier does not operate normally as described in the user manual.
Operate the controls only as described in the user manual.
if the amplier has been dropped or damaged in any other way.
when the amplier exhibits a distinct change from its normal function or
performance.
13. Servicing
Do not attempt to service this amplier yourself. As opening or removing covers may expose you to dangerous voltage or other hazards, the amplier may only be opened by qualied personnel. Please refer to your dealer/distributor.
14. Servicing and Replacement Parts
All service and repair work must be carried out by a CAMCO authorised dealer. When replacement parts are required, please ensure that the dealer/distributor only uses replacement parts specied by the manufacturer. The use of un­authorized replacement parts may result in injury and/or damage through re or electric shock or other electricity-related hazards.
15. Safety Check
Upon completion of any service or repairs to this product, ask the dealer/ distributor to perform safety checks to determine that the amplier is in proper operating condition. Recommendations on how to carry out the safety test can be found in DIN VDE 0701-1 “Maintenance, Modication and Test of Electronic Appliances“.
USER MANUAL
TECTON POWER AMP SERIES
P.4
Page 6
EC Declaration of Conformity in accordance to EC Directives:
electro-magnetic compatibility (Council Directive 89/336/EEC, as amended by Directives 92/31/EEC and 93/68/EEC); low-voltage electrical equipment (Council Directive 73/23/EEC )
Manufacturers Name:
CAMCO Produktions- und Vertriebs- GmbH für Beschallungs- und Beleuchtungsanlagen
Manufacturers Address:
Fischpicke 5, 57482 Wenden – Germany
Declares that the product with the model name:
CAMCO Power amplier TECTON-38.4, 32.4, 24.4, 28.2, 22.2 and 14.2
Conforms to the following standards:
EN60065 Security
EN55103-1 Emission
EN55103-2 Immunity
The operating conditions and application environments presupposed in the information for use (user manual) are to be kept accordingly. Please Note: The following formulations have been chosen: TECTON-38.4, TECTON-32.4, TECTON-24.4, TECTON-28.2, TECTON-22.2 and TECTON-14.2 for the type plate and the EC Declaration of Conformity. TECTON 38.4, TECTON
32.4, TECTON 24.4, TECTON 28.2, TECTON 22.2 and TECTON 14.2 for the front face of the appliance and for the text in the user manual.
Wenden, 09.12.2004
Joachim Stöcker
USER MANUAL
TECTON POWER AMP SERIES
EC DECLARATION OF CONFORMITY
P.5
Page 7
CONTENTS
USER MANUAL
TECTON POWER AMP SERIES
P.6
P.2
IMPORTANT SAFETY INSTRUCTIONS
P.3
EXPLANATION OF SYMBOLS / SAFETY
P.5
EC DECLARATION OF CONFORMITY
P.6
CONTENTS
P.7
1 WELCOME
1.1 Welcome to CAMCO
1.2 Unpacking
P.8
1.3 The Amplier
P.9
2 FACILITIES
2.1 TECTON – The Front
2.2 TECTON – The Rear
P.10
2.3 Factory Settings
P.11
3 INSTALLATION
3.1 Mains Supply
P.12
3.2 On/Off Switch
3.3 Mounting
P.13
3.4 Cooling
3.5 Ground Lift
3.6 Mode Indicators
P.14
3.7 Mode Selector
3.8 Wiring
3.8.1 E.U.I.2 and XLR Connection
P.15
3.8.2 Stereo Operation
3.8.3 Parallel-Mono Operation
3.8.4 Mono-Bridge Operation
P.16
3.8.5 SPEAKON Connection
P.17
4 OPERATION
4.1 Controls
4.1.1 Volume Control
4.1.2 Gain Selector
4.1.3 Gain and Input Sensitivity
4.1.4 Limiter Switch
4.1.5 HPF-Filter
P.18
4.2 Indicators
4.2.1 Output Current LEDs
4.2.2 Signal LEDs
4.2.3 Clip LEDs
P.19
4.3 Power Amp Protection Systems
4.3.1 Clip Limiter
4.3.2 SOA Protection
4.3.3 DC Protection
4.3.4 DC Servo
4.3.5 Over Current Protection
4.3.6 Thermal Protection
4.4 Mains Protections
P.20
4.4.1 Inrush Current Limitation
4.4.2 Mains Over Voltage Detection
4.4.3 Mains Failure Detection
4.4.4 Fuse Protection
4.5 Main SMPS Protections
4.5.1 Over Current Protection
4.6 Fans
5 OPTIONS
P.21
5.1 E.U.I.2 (Extended User Interface)
5.1.1 What Are The Possibilities Using the E.U.I.2
6 TROUBLESHOOTING
P.22
6.1 Problem: No Sound
6.2 Problem: No Channel Separation
6.3 Problem: Distorted Sound
6.4 Problem: Hiss
6.5 Problem: Squeals and Feedback
7 SPECIFICATION
P.23
8 MEASUREMENTS
P.26
P.31
9 WARRANTY INFORMATION
9.1 Summary Of Warranty
9.2 Items Excluded From This Warranty
9.3 What CAMCO Will Do
9.4 How To Obtain Warranty Service
9.5 CAMCO’s Product Improvement
P.32
10 SERVICE INFORMATION
P.33
11 MAINTENANCE INFORMATION 12 DECOMISSIONING
P.34
COMPANY INFORMATION
Page 8
1.1 Welcome to CAMCO
Established in 1983, CAMCO has gained worldwide experience with professional sound reinforcement technology. Within the audio market, CAMCO specialises in the production and marketing of high quality power ampliers and sound systems for use both on tour and in static installations.
The success of the LA, DL, DX and VORTEX series of power amps has made the CAMCO name synonymous with professional quality, high performance and utterly reliable power amps.
1.2 Unpacking
Please unpack and inspect your new amplier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately. Only you, the consignee, may initiate a claim for shipping damage. CAMCO will be happy to cooperate fully as needed. Please save the shipping carton as evidence of damage for the shipper’s inspection.
Even if the amplier has arrived in perfect condition, save all packing materials so you will have them if you ever need to transport the unit.
1 WELCOME
CAMCO’s commitment to research and development, seen not just in the area of materials and technology but also most importantly in its highly skilled and motivated workforce, is one of the keys to its ongoing success.
Welcome to the new world of professional power ampliers –
WELCOME TO CAMCO!
NEVER SHIP THE AMPLIFIER WITHOUT THE ORIGINAL PACKING MATERIALS.
When shipping the TECTON amplier, always use the original shipping carton and packing materials. For maximum protection, repack the unit as it was origi­nally packed at the factory.
USER MANUAL
TECTON POWER AMP SERIES
P.7
Page 9
1.3 The Amplier
The TECTON is a Class-H power amplier with a power output of:
TECTON 38.4 1900 W per channel @ 4
TECTON 32.4 1600 W per channel @ 4
1 WELCOME
TECTON 24.4 1200 W per channel @ 4
TECTON 28.2 1420 W per channel @ 2
TECTON 22.2 1140 W per channel @ 2
TECTON 14.2 730 W per channel @ 2
3800 W in Mono-Bridge @ 8 3800 W in Parallel-Mono @ 2
3200 W in Mono-Bridge @ 8 3200 W in Parallel-Mono @ 2
2400 W in Mono-Bridge @ 8 2400 W in Parallel-Mono @ 2
2840 W in Mono-Bridge @ 4 2840 W in Parallel-Mono @ 1
2280 W in Mono-Bridge @ 4 2280 W in Parallel-Mono @ 1
1460 W in Mono-Bridge @ 4 1460 W in Parallel-Mono @ 1
TECTON ampliers are tted with Switched Mode Power Supplies (SMPS), which signicantly reduces the weight and size (only 2U) of the amplier. Using SMPS, the 2 symmetrical supply voltages (1 symmetrical supply voltage for TECTON
22.2 and TECTON 14.2) of the power amplier are more stable than the power supplies used in conventional ampliers.
The TECTON has been designed as an intelligent and powerful product for performing specialised tasks within a complex audio system. Users can adapt the power amp to meet their specic audio requirements before use. Controls mounted on the front and the rear of the TECTON allow access to the functio­nality. Since some of the externally mounted controls have multiple functions, it is important that users should familiarise themselves thoroughly with the entire range of controls.
If you have any questions regarding features and/or functions of your TECTON, CAMCO will be pleased to provide you with further information. Alternatively, contact your dealer or distributor.
USER MANUAL
TECTON POWER AMP SERIES
P.8
Page 10
5 76
2 FACILITIES
2.1 TECTON – The Front
1 On/Off Switch 2 Volume Control – Channel A 3 Volume Control – Channel B 4 Operating Mode LEDs (multifunctional) 5 Clip LEDs 6 Output Current LEDs 7 Signal LEDs (multifunctional)
1415121110
19 2017 18
16
2.2 TECTON – The Rear
8 AC Power Cable 9 Cooling Air Outlet Vents 10 Input Ground Lift Switch 11 High Pass Filter B 12 Mode Selector 13 Clip Limiter Switch
13
14 High Pass Filter A 15 Gain Selector 16 Extended User Interface
(E.U.I. 2) 17 XLR – Line Input B 18 XLR – Line Input A
2221
OUTPUT B OUTPUT A
19 XLR – Line Link B 20 XLR – Line Link A 21 SPEAKON Outlet B 22 SPEAKON Outlet A 23 Rating Plate
23
89
1324
USER MANUAL
TECTON POWER AMP SERIES
P.9
Page 11
2.3 Factory Settings
TECTON ampliers are delivered with the following factory settings
2 FACILITIES
Front panel:
On/Off Switch Off Amplier is switched off
10
11
12
15
14
13
16
18
17
20
19
Rear panel:
10 Input Ground Lift Grounded 11 High Pass Filter channel B Off 12 Mode Selector Stereo 13 Limiter Off 14 High Pass Filter channel A Off 15 Gain Selector 26 dB
Make sure that the switches are set to the conguration needed for each par­ticular application. For more detailed information, see sections 3.5, 3.7 and 4.1.
P.10
USER MANUAL
TECTON POWER AMP SERIES
Page 12
TECTON-22.2
230 V ~ 50/60 Hz 10,6 A 1120 W
1100 W / 2 Ohm
xxxxxxx
TECTON-24.4
230 V ~ 50/60 Hz 10,5 A 1060 W
1600 W / 2,7 Ohm
xxxxxxx
TECTON-28.2
230 V ~ 50/60 Hz 9,5 A 1002 W
1400 W / 2 Ohm
xxxxxxx
TECTON-32.4
230 V ~ 50/60 Hz 9,8 A 1010 W
1600 W / 4 Ohm
xxxxxxx
TECTON-14.2
230 V ~ 50/60 Hz 7,4 A 712 W
700 W / 2 Ohm
xxxxxxx
TECTON-38.4
230 V ~ 50/60 Hz 11,3 A 1220 W
1900 W / 4 Ohm
xxxxxxx
3.1 Mains Supply
When mounting or connecting the amp always disconnect it from mains. Only connect the TECTON amplier to a appropriate AC circuit and outlet, according to the requirements indicated in the second line on the rating plate.
Exemplary rating plates for a mains supply of 230 V AC 50/60 Hz.
Power supply data:
Voltage Mains Frequency Current Power Consumtion TECTON-38.4 120 V 50/60 Hz 22,6 A 1220 W TECTON-38.4 220 V 60 Hz 11,3 A 1220 W TECTON-32.4 120 V 50/60 Hz 19,6 A 1010 W TECTON-32.4 220 V 60 Hz 9,8 A 1010 W TECTON-28.2 120 V 50/60 Hz 19 A 1002 W TECTON-28.2 220 V 60 Hz 9,5 A 1002W TECTON-24.4 120 V 50/60 Hz 21 A 1060 W TECTON-24.4 220 V 60 Hz 10,5 A 1060 W TECTON-22.2 120 V 50/60 Hz 21 A 1120W TECTON-22.2 220 V 60 Hz 10,6 A 1120 W TECTON-14.2 120 V 50/60 Hz 14,8 A 712 W TECTON-14.2 220 V 60 Hz 7,4 A 712 W
NOTE: Even under normal conditions the mains current can reach levels up to 60 A (230 V) and 120 A (120 V), respectively; this could cause lamps to icker if connected to the same mains as the amp. The impedance of the AC circuit should be less than 0,157 Ohms to avoid icker according to EN61000-3-11 “Electromagnetic compatibility – Part 3-11: Limits – Limitation of voltage changes, voltage uctuations and icker in the public low-voltage supply systems – Equipment with rated current more than 75 A and subject to conditional connection”. If in any doubt, consult your local power provider. Never attempt to measure this impedance level with your ohmmeter. This may damage your meter and expose you to the risk of electric shock!
3 INSTALLATION
USER MANUAL
TECTON POWER AMP SERIES
P.11
Page 13
3.2. On/Off Switch
The On/Off Switch is a rocker-type switch. It is located on the right side of the front panel. To turn the amplier on, push in on the upper part of the switch. This initiates start-up by activating the inrush current limiter. During power up the Clip and Signal LEDs from both channels will light up in red for a few seconds. To turn the amplier off, push in on the lower part of the switch.
3 INSTALLATION
Amplier is switched on Amplier is switched off
NOTE: This switch does NOT disconnect the amplier from mains. Make sure the mains power socket or an alternative disconnect device is near by and easily accessible.
3.3 Mounting
Use four screws and washers when mounting the amplier to the front rack rails. For mobile use, the amplier should also be secured using the 19” mounting elements on the rear panel.
10 mm
7 mm
7 mm
76,2 mm
88,9 mm
76,2 mm
466 mm
442 mm
10 mm
P.12
The switch initiates start-up by activating the current limiting function. As soon as the power amplier is connected to the mains power supply, a vol­tage is supplied to both the line-lter and the fused input of the controllable rectier. Disconnecting the amplier from the main power supply can only be achieved by physically separating the amplier from the mains by pulling the mains plug. The mains plug therefore has to be freely accessible. Disconnect the mains plug from the mains during a lightning storm or when the amplier remains unused or unsupervised for a prolonged period of time. Alternatively, you can disconnect the amplier via an external all-pole disconnection from the mains. If a power cut occurs while the amplier is switched on, it will restart automati­cally once the power supply has been restored. All settings operation prior to the loss of power will be maintained.
USER MANUAL
TECTON POWER AMP SERIES
330,7 mm
356,2 mm
347,2 mm
Page 14
3.4 Cooling
Under normal operation of the power amp, overheating should never be a problem. The air is taken in from the front and out through the back, it is of course essential that while the power amp is running air is able to circulate around it freely. The efciency of the cooling will depend on the immediate environment (e.g. an enclosed rack, direct sunlight). If the amp is installed in a case, the open area at the back of the case must be at least 140 cm². This area should be in line with the amp. If this can not be achieved a forced ventilation system has to be used.
3.5 Ground Lift
The input signal ground (pin 1 for all 4 XLRs) is connected to the ground of the mains supply. In order to avoid ground loops, this connection can be separated via a resistor. The ground potential of the power amp and the ground of the loudspeaker always remain connected to the ground of the mains supply regardless of the setting of this switch.
3.6 Mode Indicators
On the front panel there are two yellow LEDs to indicate the mode that is set. In stereo mode (2-channel) none of them will be lit. In Parallel-Mono the (PM) LED will be lit and in Mono-Bridge, the (MB) LED will be lit.
3 INSTALLATION
Amplier in Parallel-Mono mode Amplier in Mono-Bridge mode
Lift Position
to Pin 1 of the XLRs
Removing or taping the mains connector ground is illegal and dangerous.
Ground Position
DO NOT REMOVE MAINS CONNECTOR GROUND
IT IS ILLEGAL AND DANGEROUS
USER MANUAL
TECTON POWER AMP SERIES
P.13
Page 15
3.7 Mode Selector
The switch on the rear panel changes the operating mode. Switch the power switch to the Off position to make changes on the Mode Selector. When the amplier is switched on again, the selected mode will operate.
3.8 Wiring
3.8.1 E.U.I. and XLR Connection
XLR: Pin 1 = Ground (or lifted via 15 resistor) (See 3.5 Ground Lift) Pin 2 = Hot (inphase) Pin 3 = Cold (out of phase) Always use symmetrical (balanced) shielded cable to connect the amplier.
3 INSTALLATION
P.14
USER MANUAL
TECTON POWER AMP SERIES
Channel B
To
Channel B
Input
Channel A
12
3
2
To
Channel A
Input
Ground
Lift
1
3
LINK BInput
1
2 2
3
Input Ground Lift in position: grounded
LINK A
1
3
Page 16
3.8.2 Stereo Operation, 2 Channel Operation
Two fully independent amplier channels (normal operating mode).
3.8.3 Mono-Bridge Operation
One-channel mono bridged operation.
TECTON
A (L)
Z *Z
min
B (R)
Z *Z
min
3.8.3 Parallel-Mono Operation
Parallel operation of the two channels together.
TECTON
A
Z
res
0.5 *Z
min
The output terminals of the two channels are congured in parallel using an in­ternal relay. The (single) load is connected either to the output of channel A or to that of channel B (as if in stereo). While the total output of the amplier remains the same and the output voltage level is also the same as in stereo operation, the minimum impedance that can be connected is reduced by half due to the fact that current capability is doubled. Only channel A-Input is active. The chan­nel B-Input is inactive – turn the volume of channel B down to zero. This mode is useful when, for example, 3 identical loudspeakers are to be operated with the same power.
TECTON
A
Z 2 *Z
min
The second channel processes the same input signal, but with reversed phase. The (single) load is connected between the two positive channel outputs using a suitable connected SPEAKON connector. While the total output of the ampli­er remains the same, both the available output voltage and the minimum impedance that can be connected are doubled, as compared with stereo ope­ration. Only channel A-Input is active. A signal feeding channel B will have no effect on the output. Turn the volume of channel B down to zero.
WARNING ! In Mono-Bridge mode RMS output voltages are as high as 230 V. Wiring to the speaker loads must conform to NEC Class 3 safety standards or its aquivalent that meets all national and local electric codes. All customer specic cables may only be manufactured by qualied suppliers/personnel. All cabling or rewiring work must be carried out by qualied personnel.
* Z
= 2 for TECTON 28.2, 22.2 and 14.2
min
* Z
= 4 for TECTON 38.4, 32.4 and 24.4
min
USER MANUAL
TECTON POWER AMP SERIES
3 INSTALLATION
P.15
Page 17
3.8.5 SPEAKON Connection
Both SPEAKON connectors are connected to channel A and channel B outputs. The pin conguration of the SPEAKON connectors is as follows:
Output A: Pin 1+ Channel A signal
(View at the back) Pin 1- Channel A ground
Pin 2+ Channel B signal Pin 2- Channel B ground
4 OPERATION
Output B: Pin 1+ Channel B signal
(View at the back) Pin 1- Channel B ground
Pin 2+ Channel A signal Pin 2- Channel A ground
WARNING ! SPEAKON connectors marked with the lightning ash indicate high vol­tages that are potentially life threatening.
Wiring to these terminals requires installation by an instructed person or the use of ready-made leads or cords.
Custom wiring should only be made by qualied personnel.
To prevent electric shock, do not operate the amplier with any of the con­ductor portion of the speaker wire exposed.
P.16
Input Channel A
Input Channel B
USER MANUAL
TECTON POWER AMP SERIES
Output A
Output B
NOTE: For reasons of safety and performance, use only high-quality fully insu­lated speaker cables of stranded copper wire. Use the largest wire size that is economically and physically practical, and make sure the cables are no longer than necessary.
IMPORTANT: When connecting speaker cabinets in parallel, always use all the contacts in both SPEAKON connectors. If not, this may cause permanent damage to the connectors and considerably reduce performance.
Page 18
4.1 Controls
4.1.1 Volume Control
A volume control with 41 notched settings controls the audio signal. These settings have been selected to correspond to human hearing characteristics (logarithmically) and therefore guarantee an optimal range of settings for prac­tical applications. Each channel can be set individually except when operating in mono modes whereby only channel A is active.
Set the volume to zero before turning on the amplier to prevent the occur­rence of sudden high volume levels which may cause damage to your hearing and/or the speakers.
4.1.2 Gain Selector
A switch on the rear of the TECTON allows the maximum amplication attain­able to be set directly in the input stage.
The TECTON amplier has a 26 dB and 32 dB voltage gain setting along with a 1,4 V sensitivity setting.
4.1.3 Gain and Input Sensitivity
The table shows input sensitivity per channel for a given gain and load. It also shows the gain for the 1,4 V input sensitivty.
Model 26 dB 32 dB 1,4 V
38.4
32.4
24.4
28.2
22.2
14.2
4.1.4 Limiter Switch
This switch is located at the rear of TECTON. It allows you to set the mode of the limiter. There are three modes. (See 4.3.1 Clip Limiter)
Right position: Middle position: Left position:
Clip Limiter: Fast Clip Limiter: Slow Clip Limiter: Off Attack fast Attack slow
4 @1900 W 8 @ 1100 W 4 @ 1600 W
8 @ 915 W
4 @ 1200 W
8 @ 700 W
2 @ 1420 W
4 @ 920 W
2 @ 1140 W
4 @ 660 W 2 @ 730 W 4 @ 420 W
4,37 V 4,70 V 4,01 V 4,29 V 3,47 V 3,75 V 2,67 V 3,04 V 2,39 V 2,58 V 1,92 V 2,05 V
2,19 V 2,36 V 36,52 dB 2,01 V 2,15 V 35,72 dB 1,74 V 1,88 V 34,56 dB 1,34 V 1,52 V 32,74 dB 1,20 V 1,29 V 31,29 dB 0,96 V 1,03 V 29,33 dB
4 OPERATION
USER MANUAL
TECTON POWER AMP SERIES
P.17
Page 19
4.1.5 HPF Filter
(Channel A as example)
Left position: Middle position: Right position:
4 OPERATION
HPF: Off HPF: 30 Hz HPF: 50 Hz
HPF OFF
HPF 30 Hz
4.2 Indicators
4.2.1 Output Current LEDs
The brightness is proportional to the output current in the channel. Output current of approx. 1 A lights up the LED at its lowest brightness level, while full brightness corresponds to the maximum rated current.
P.18
USER MANUAL
TECTON POWER AMP SERIES
HPF 50 Hz
Low frequency response curves
4.2.2 Signal LEDs (multifunctional)
The channels Signal LED is illuminated green when the voltage level at the output reaches approx. 4 V; this corresponds to a power of approx. 4 W at an impedance of 4 Ohms. The channels Signal LED is illuminated red while the Amp is in Protect Mode (Mute).
Page 20
4.2.3 Clip LEDs
If the power level is overloaded, the Clip LED will light up.
4.3.3 DC Protection
Each output of the power amp is constantly monitored for persistent DC voltage levels. If the 3 V thresholds are exceeded at any of the outputs, the correspond­ing channel will be muted. If DC was only applied for a short moment, the ampli­er will realase mute and work as normal. If DC is applied for longer periodes or several short times the amplier will switch to stand by mode. Switch off the amplier, wait until the power LED stops ashing and switch the amplier on again.
4.3.4 DC Servo
To prevent DC Offset at the speaker output the TECTON is tted with a DC Servo.
4 OPERATION
4.3 Power Amp Protection Systems
4.3.1 Clip Limiter
If the power amp is overdriven, the clip detection triggers the Attack-Release­Circuit (ARC). The ARC delivers the control voltage for the gain reduction. Two different attack modes (fast and slow) could be chosen with the Clip Limiter switch (see 4.1.4 Limter Switch).
4.3.2 SOA Protection
Whenever the power transistors leave their Safe Operation Area (SOA), the SOA-protection in stereo mode switches back the current rail of the respective channel. In mono modes the rails of both channels are switched back.
4.3.5 Over Current Protection
Over current is permanently controlled in the output stage. There are two limit­ing levels of over current depending on output voltage. These limits will be set automatically. This improves reliability without degrading sound quality when driving complex loads.
4.3.6 Thermal Protection
There are several sensors in the amp in order to ascertain temperature data. If a temperature of more than 85 °C is detected at the heat sinks, the input signal on that channel is reduced. If the temperature exceeds 100 °C, the main SMPS is switched off.
USER MANUAL
TECTON POWER AMP SERIES
P.19
Page 21
4.4 Mains Protections
4.4.1 Inrush Current Limitation
Within 2 seconds of the amplier being switched on, the inrush current limiter will increase mains current from nearly zero to nominal value. This value depends on program material, output level and speaker loads.
4.4.2 Mains Over Voltage Detection
Mains over voltage detection is always operative. When the mains voltage
4 OPERATION
exceeds approx. 267 V (230 V operation) or 134 V (120 V operation), the ampli­er will be switched off. The system will try to start in intervalls and will return with a soft start when the regular mains voltage returns.
4.4.3 Mains Failure Detection
Mains failure detection is always operative. When the mains supply is inter­rupted for about 2 mains cycles, the amplier will be switched off. When the mains voltage returns to a normal value, a soft start occurs.
4.4.4 Fuse Protection
The average mains current can peak temporarily, depending on the load im­pedance and type of signal, at values signicant higher than the nominal value allowed by the fuse protection. Continuous monitoring of the fuse protection status allows the conditions that would trigger the fuse protection to be predicted. In order to avoid shut-down of the amplier due to current overload, the amplitude of the input signals will be limited and by hard overloads the amp will be muted for the time.
4.5 Main SMPS Protections
4.5.1 Over Current Protection
Main SMPS (Switched Mode Power Supply) transformer current is continuously monitored. If over current occurs, the main SMPS immediately stops working. Should there be an internal failure, this feature prevents other parts being damaged.
4.6 Fan
The fan mounted in the TECTON operates permanently, but as long as the temperature remains below 40 °C it runs at its slowest speed and can hardly be heard. The highest detected temperature from either channel controls the speed of the fan: above 40 °C the speed is increased until it reaches its maximum value.
P.20
USER MANUAL
TECTON POWER AMP SERIES
Page 22
5.1 E.U.I.2 (Extended User Interface)
CAUTION! Always switch off and unplug the TECTON from mains, before making alterations to the E.U.I. card.
The E.U.I. card contains the Rear XLR Panel as standard. Other input cards are available (See 5.1.1 What Are The Possibilities Using The E.U.I.2?). To remove the E.U.I.2 unscrew the two Phillips head screws at the left and right end of the XLR-Panel and carefully slide out the E.U.I.2. To ret the E.U.I.2, carefully insert it. Pay attention that the cable is not clamped.
ATTENTION! Don’t forget to tighten the screws!
5.1.1 What Are The Possibilities Using The E.U.I.2?
The E.U.I.2 is a very powerful interface, which allows access to most of the system parameters, such as volume, input signal, mute, output current, clip signal, temperature and more. You can use the E.U.I.2 as a lter, remote control, signal processing device and more… Please contact your dealer/distributor or CAMCO to customise the E.U.I.2 according to your wishes.
5 OPTIONS
USER MANUAL
TECTON POWER AMP SERIES
P.21
Page 23
6.1 Problem: No Sound
Indication:
Indication:
6 TROUBLESHOOTING
Indication:
Indication:
6.2 Problem: No Channel Separation
Signal LEDs not lit Clip LEDs not lit
Check AC plug.
Conrm that AC outlet works by plugging in another device.
Output Current LEDs are lit Signal LEDs not lit
Make sure the signal source is operating and try another cable.
Check position of volume pots.
Output Current LEDs are lit Signal LEDs responding to signal level
Check the speaker wiring for breaks.
Try another speaker and cable.
Signal LEDs show red (Protect Mode)
Overheating will cause protective muting. Check for proper ventilation.
If the fan isn’t running the amplier requires servicing.
Check the mode indicators on the front panel and make sure the mode
selector on the rear panel is in the stereo-position.
Make sure other equipment in the signal path such as mixers and preamps
are set for stereo, not mono.
6.3 Problem: Distorted Sound
Indication:
Output Current LEDs are lit Signal LEDs responding to signal level Clip LEDs not lit
A faulty speaker or a loose connection could cause this. Check the wiring
and try another speaker.
The signal source might be clipping. Keep the TECTON volume pots at
least halfway up so that the source does not have to be overdriven.
Keep the TECTON volume pots at least halfway up and try changing input
sensitivity from 1,4 V to 32 dB or 26 dB with the gain selector on the rear.
6.4 Problem: Hiss
Unplug the amplier input to conrm that the hiss is coming from the
source or from a device upstream. Erratic or popping noises indicate an electronic fault in the offending unit.
To keep the noise oor low, operate the primary signal source at full level,
without clipping.
Avoid boosting the signal further between the source and the amplier.
6.5 Problem: Squeals and Feedback
Microphone feedback should be eliminated with mixer controls. If noise
continues to build up with no microphone gain, there is a serious fault in the signal processors or cables. Working in succession from the signal source towards the amplier and check each device in the signal path by reducing its gain or by unplugging it.
P.22
USER MANUAL
TECTON POWER AMP SERIES
Page 24
Output Power
TECTON 38.4
1 kHz, THD 1 %, in mono-bridge mode
1 x 3800 W @ 8
1 x 2200 W @ 16
1 kHz, THD 1 %, both channels driven
Duration limited by fuse / thermal protection for RL < 8
in stereo mode or RL < 16 in mono-bridge mode.
2 x 1900 W @ 4 2 x 1100 W @ 8
1 kHz, THD < 0,1 %, both channels driven
2 x 1800 W @ 4 2 x 1070 W @ 8
Circuitry Bipolar, Class H 2-step
high efciency circuit
Signal to Noise-Ratio
20 Hz - 20 kHz, 8 load, unweighted
A-weighted
Power Consumption @ 230 V
(both channels driven)
>112 dB
>116 dB
Typical1)Max
Idle 1,4 A
2)
60 W
4,8 A
16
410 W
7,3 A
8
700 W
11,3 A
4
1220 W
Multiply currents by 2 for 120 V
2)
1)
1/8 of max Output Power with pink noise to represent typical music signal max. rated Output Power (see above)
14,8 A
1600 W
25 A
3000 W
40 A
5230 W
TECTON 32.4
1 x 3200 W @ 8
1 x 1800 W @ 16
2 x 1600 W @ 4
2 x 915 W @ 8
2 x 1500 W @ 4
2 x 860 W @ 8
Bipolar, Class H 2-step high efciency circuit
>111 dB >115 dB
Typical1)Max
Idle 1,3 A
55 W
3,9 A
16
330 W
6,2 A
8
580 W
9,8 A
4
1010 W
12,2 A
1280 W
21 A
2410 W
34 A
4300 W
1 x 2400 W @ 8
1 x 1400 W @ 16
2 x 1600 W @ 2,7
2 x 1200 W @ 4
2 x 1135 W @ 4
Bipolar, Class H 2-step
high efciency circuit
2)
Idle 1,2 A
16
8
4
2,7
TECTON 24.4
2 x 700 W @ 8
2 x 655 W @ 8
>110 dB >115 dB
Typical1)Max
50 W
3,9 A
250 W
5,2 A
460 W
7,9 A
790 W
10,5 A
1060 W
7 SPECIFICATION
2)
9,9 A
1000 W
16,5 A
1840 W
27 A
3230 W
36 A
4600 W
USER MANUAL
TECTON POWER AMP SERIES
P.23
Page 25
Output Power
TECTON 28.2
1 kHz, THD 1 %, in mono-bridge mode
1 x 2800 W @ 4 1 x 1820 W @ 8
1 kHz, THD 1 %, both channels driven
Duration limited by fuse / thermal protection for RL < 8
in stereo mode or RL < 16 in mono-bridge mode.
1 kHz, THD < 0,1 %, both channels driven
2 x 1400 W @ 2
2 x 910 W @ 4
2 x 1310 W @ 2
2 x 860 W @ 4
7 SPECIFICATION
Circuitry Bipolar, Class H 2-step
high efciency circuit
Signal to Noise-Ratio
20 Hz - 20 kHz, 8 load, unweighted
A-weighted
Power Consumption @ 230 V
(both channels driven)
>108 dB
>113 dB
Typical1)Max
Idle 1,2 A
8
360 W
4
611 W
2
1002 W
Multiply currents by 2 for 120 V
2)
1)
1/8 of max Output Power with pink noise to represent typical music signal max. rated Output Power (see above)
45 W
4,2 A
6,5 A
9,5 A
13,1 A
1380 W
21 A
2490 W
33 A
4220 W
1 x 2200 W @ 4 1 x 1320 W @ 8
2 x 1100 W @ 2
2 x 660 W @ 4
2 x 1040 W @ 2
2 x 620 W @ 4
Bipolar, Class AB
high efciency circuit
2)
Idle 1,4 A
8
4
2
TECTON 22.2
>105 dB >111 dB
Typical1)Max
60 W
4,3 A
370 W
6,8 A
640 W
10,6 A
1120 W
10,1 A
1020 W
16,8 A
1870 W
27 A
3320 W
high efciency circuit
2)
Idle 1,2 A
8
4
2
TECTON 14.2
1 x 1340 W @ 4
1 x 800 W @ 8
2 x 670 W @ 2 2 x 400W @ 4
2 x 610 W @ 2 2 x 380 W @ 4
Bipolar, Class AB
>98 dB
>108 dB
Typical1)Max
50 W
3,3 A
250 W
4,7 A
420 W
1180 W
7,4 A
712 W
2130 W
2)
6,8 A
660 W
10,9 A
17,3 A
P.24
USER MANUAL
TECTON POWER AMP SERIES
Page 26
Frequency Response 20 Hz - 20 kHz ± 0,15 dB
Input Impedance 14 k balanced Voltage Gain selectable: 26 dB, 32 dB, or 1,4 V input sensitivity Protection Circuits inrush-current limitation, temperature monitoring of transformer and heat-sinks,
Limiter switchable clip limiter Fan temperature dependent speed-controlled axial fan Ground Lift input ground lift switch on back panel Indicators LEDs for Mode, Signal, Clip, Output Current and faults for example like DC Input Connectors 3-pin XLR, male and female per channel, pin 2 = inphase (hot) Output Connectors one 4-pole SPEAKON connector for each output channel (bi-amping possible) Modes of Operation Stereo, Mono-Bridge and Parallel-Mono Options Extended User Interface / E.U.I. 2 – modules for any kind of EQ THD+N (typical) < 0,01 %
20 Hz - 10 kHz, 8 load, 10 dB below rated power
SMPTE (typical) < 0,01 %
8 load, 10 dB below rated power
Damping Factor > 400
8 load, 1 kHz and below
Dimensions (WxHxD) 483 x 88,9 x 330 mm (19”, 2U) Net Weight 9,4 kg Shipping Dimensions (WxHxD) 540 x 135 x 540 mm (0,04 m3) Shipping Weight 11 kg
8 load, 10 dB below rated power
output DC protection, power transistor SOA protection, output over current protection, mains fuses protection
Subject to technical alterations without prior notice
7 SPECIFICATION
USER MANUAL
TECTON POWER AMP SERIES
P.25
Page 27
8 MEASUREMENTS
P.26
+27
+26.5
+26
+25.5
+25
+24.5
+24
dBr
+23.5
+23
+22.5
+22
+21.5
+21
10 100k20 50 100 200 500 1k 2k 5k 10k 20k 50k
+26
+24
+22
+20
+18
+16
dBr
+14
+12
+10
+8
+6
+4
+2
-0 10 20k20 50 100 200 500 1k 2k 5k 10k
Gain vs. frequency / Different positons of HPF-Switch (Ch1, Ch2)
USER MANUAL
TECTON POWER AMP SERIES
Hz
Figure 8.1
Gain vs. frequency (Ch1, Ch2)
(Measurements of a typical performance)
Hz
Figure 8.2
(Measurements of a typical performance)
+180
+135
+90
+45
+0
deg
-45
-90
-135
-180 10 100k20 50 100 200 500 1k 2k 5k 10k 20k 50k
Hz
Figure 8.3
Phase vs. frequency (Ch1, Ch2)
(Measurements of a typical performance)
+180
+135
+90
+45
deg
+0
-45
-90
-135
-180 10 20k20 50 100 200 500 1k 2k 5k 10k
Hz
Figure 8.4
Phase vs. frequency / Different positons of HPF-Switch (Ch1, Ch2)
(Measurements of a typical performance)
Page 28
300m
200m
100m
50m
Ohm
20m
10m
5m
2m
20 20k50 100 200 500 1k 2k 5k 10k
Figure 8.5 Output impedance vs. frequency
Hz
@ 1 Amp RMS injected current (Ch1, Ch2) equivalent 11 m + 2,1 µH
(Measurements of a typical performance of TECTON 32.4)
-20
-30
-40
-50
-60
dB
-70
-80
-90
-100
-110
-120 100u 5200u 500u 1m 2m 5m 10 m 20m 50m 100m200m 500m 1 2
Vrms
Figure 8.6
THD+N @ 1 kHz, 8 load vs. input voltage (Ch1, Ch2)
(Measurements of a typical performance of TECTON 32.4)
1000
800
r o
600
t c a f
g n
i p
m
400
a d
200
0
20 20k50 100 200 500 1k 2k 5k 10k
Hz
Figure 8.7 Damping factor into 8 (Ch1, Ch2)
equation: damping factor = loaded impedance / amplier output impedance
(Measurements of a typical performance of TECTON 32.4)
-20
-30
-40
-50
-60
-70
dB
-80
-90
-100
-110
-120 20 10k50 100 200 500 1k 2k 5k
Hz
Figure 8.8
THD+N vs. frequency (BW 22 kHz), 10 dB below clip, 8 (Ch1, Ch2)
(Measurements of a typical performance of TECTON 32.4)
USER MANUAL
TECTON POWER AMP SERIES
8 MEASUREMENTS
P.27
Page 29
8 MEASUREMENTS
P.28
-20
-30
-40
-50
-60
dB
-70
-80
-90
-100
-110
-120 100u 5200u 500u 1m 2m 5m 10m 20m 50m 100m200m 500m 1 2
Vrms
Figure 8.9
CCIF difference frequency method (10,5 kHz and 11,5 kHz) vs. input level
@ 8 (Ch1, Ch2) (Measurements of a typical performance of TECTON 32.4)
-20
-30
-40
-50
-60
dB
-70
-80
-90
-100 100u 4200u 500u 1m 2m 5m 10m 20m 50m 100m 200m 500m 1 2
Vrms
Figure 8.10
SMPTE intermodulation distortion (60 Hz and 7 kHz) @ 8 vs. input level
(Ch1, Ch2) (Measurements of a typical performance of TECTON 32.4)
USER MANUAL
TECTON POWER AMP SERIES
-20
-30
-40
-50
dBr
-60
-70
-80
-90
-100 20 20k50 100 200 500 1k 2k 5k 10k
Hz
Figure 8.11
Common mode rejection ratio (Ch1, Ch2)
(Measurements of a typical performance of TECTON 32.4)
-10
-20
-30
-40
-50
dB
-60
-70
-80
-90
-100
-110
20 20k50 100 200 500 1k 2k 5k 10k
Hz
Figure 8.12
Channel separation vs. frequency @ 10 W / 8 (Ch1 => Ch2, Ch2 => Ch1)
(Measurements of a typical performance of TECTON 32.4)
Page 30
Watts
Watts
2500
2000
1500
2000
1500
1000
2275
1900
1225
1122
1000
500
0
4
Impedance/
8
Figure 8.13
TECTON 38.4 (Measurements of a typical performance)
1800
1600
960
915
500
0
4
Impedance/
8
Figure 8.14
TECTON 32.4 (Measurements of a typical performance)
16
483
16
608
630
Distortion limited
output power (1 % THD)
500
Distortion limited
output power (1 % THD)
Peak power
Peak power
Watts
Watts
1500
1000
1500
1000
1365
1212
730
695
500
0
4
Impedance/
8
Figure 8.15
TECTON 24.4 (Measurements of a typical performance)
1440
1420
1008
920
500
0
2
Impedance/
4
Figure 8.16
TECTON 28.2 (Measurements of a typical performance)
16
370
8
515
378
Distortion limited
output power (1 % THD)
534
Distortion limited
output power (1 % THD)
Peak power
Peak power
USER MANUAL
TECTON POWER AMP SERIES
8 MEASUREMENTS
P.29
Page 31
1500
1220
1133
1000
Watts
500
700
670
370
362
Peak power
8 MEASUREMENTS
0
2
Impedance/
4
8
Distortion limited
output power (1 % THD)
Figure 8.17
TECTON 22.2 (Measurements of a typical performance)
P.30
1000
750
Watts
500
250
0
TECTON 14.2 (Measurements of a typical performance)
USER MANUAL
TECTON POWER AMP SERIES
2
700
756
Impedance/
417
4
435
Figure 8.18
230
8
233
Distortion limited
Peak power
output power (1 % THD)
Page 32
9.1 Summary Of Warranty
CAMCO guarantees the TECTON amplier to be free from defective material and/or workmanship for a period of three (3) years from the date of sale. Pro­vided that the amplier is returned to your dealer/distributor in a factory pack with a copy of the proof of purchase, i.e., sales receipt, CAMCO will repair faulty products under this warranty when a defect occurs under normal installation and use.
This warranty provides that examination of the returned product must indicate, in our judgment, a manufacturing defect.
9.2 Items Excluded From This Warranty
CAMCO is not liable for any damage caused by shipping accidents, misuse, abuse, operation with incorrect AC voltage, operation with faulty periphal equipment, modication, or alteration without prior factory approval, service by an unauthorised service center, and normal wear and tear. Ampliers on which the Serial Number has been removed or defaced are not eligible for warranty service.
9.3 What CAMCO Will Do
CAMCO (or its appointed agent) undertakes to rectify any defect, regardless of the reason for failure (unless excluded from this warrenty), by repair, replace­ment, or refund, as it sees t.
9.4 How To Obtain Warranty Service
You must notify your dealer/distributor of your need for warranty service. All components must be shipped in the original packing.
9 WARRANTY INFORMATION
9.5 CAMCO’s Product Improvement
CAMCO reserves the right to improve the technical standard of its products without giving prior notice. If in any doubt, please consult your dealer/distri-
butor or contact CAMCO directly for clarication.
USER MANUAL
TECTON POWER AMP SERIES
P.31
Page 33
PLEASE ENCLOSE THIS COMPLETED FORM WITH THE AMPLIFIER
DO NOT SEND SEPARATELY
10 SERVICE INFORMATION
P.32
Owner’s Information
Company Name: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Contact: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Address: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Telephone: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Facsimile: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ eMail Address: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Model: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Serial Number: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Purchase Date: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Expired Warranty
If the warranty has expired, payment will be:
Cash/Cheque
VISA
MasterCard
Shipping Address
To transport the amplier, the original packing materials must be used. Please return the amplier to the following address or your nearest CAMCO appointed distributor.
CAMCO Produktions- und Vertriebs- GmbH für Beschallungs- und Beleuchtungsanlagen, Fischpicke 5, D-57482 Wenden, Germany
USER MANUAL
TECTON POWER AMP SERIES
Nature Of Problem
Please describe the conditions that existed when the problem occured and what attempts were made to correct it: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Other equipment in your system: _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _
Our web site: www.camcoaudio.com provides a complete list of CAMCO dealers/distributors.
Page 34
11 Maintenance Information
Cleaning and servicing the inside of the aplier must never carry out by unquali­ed personnel. The amplier must never be opened by unqualied personnel.
Cleaning and servicing work on the inside of the amplier must only be carried out by qualied personnel.
Qualied personnel is dened as a person who has gained specialised relevant knowledge of electronic engineering through education, training and experi­ence and who has sufcient knowledge of all relevant governmental work safety regulations to be in a position to judge the safe functioning of power ampliers based on technical rules according to IEC 60065. (IEC 60065 (DIN EN 60065) “Safety Requirements for Audio, Video or simlar Electronic Appliances”)
In order to guarantee the safe functioning of the amplier, it has to be checked at least once, depending on its application and usage, by a properly qualied person. Advice on how to carry out these checks can be found in DIN VDE 0702-1 “Safety Checks for Electronic Appliances”.
An amplier that is considered to be unsafe must be labelled accordingly and stored in a safe place to prevent this amplier being used mistakenly.
12 Decomissioning
During the decomissioning process of the amplier, all legally prescribed rules and procedures must be adhered to.
USER MANUAL
TECTON POWER AMP SERIES
11 MAINTENANCE INFORMATION/12 DECOMISSIONING
P.33
Page 35
Mailing Address:
CAMCO Produktions- und Vertriebs- GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 D-57482 Wenden Germany
Telephone:
+49 (0) 27 62/4 08- 0
Facsimile:
+49 (0) 27 62/4 08- 10
Internet:
www.camcoaudio.com
COMPANY INFORMATION
Email:
postmaster@camco.de
P.34
USER MANUAL
TECTON POWER AMP SERIES
Page 36
NOTICES
Page 37
Page 38
www.camcoaudio.com
Loading...