Califone PA-IRSYS User Manual

CAUTION
RISK OF ELECTRIC SHOCK - DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER OR BACK.
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QAULIFIED PERSONNEL.
!
Infrared Classroom Audio System
The lightening ash with arrowhead within a triangle is intended to tell the user that parts inside the product are a risk of electric shock to persons.
This product is not designed to function normally in strong electro­magnetic elds. Consequently, the
product is exposed to strong electromagnetic elds. Normal audio quality operation will be recovered when the strong electromagnetic eld is no longer present.
audio quality may degrade while the
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION: ALL SAFETY AND OPERATING INSTRUCTIONS SHOULD BE READ BEFORE OPERATING APPLIANCE. ALL OPERATING AND USE INSTRUCTIONS SHOULD BE FOLLOW­ED WHEN OPERATING THE APPLIANCE. HEED AND ADHERE TO ALL WARNINGS ON THE APPLIANCE AND IN THE OPERATING INSTRUCTIONS. RETAIN ALL SAFETY AND OPERATING INSTRUCTIONS FOR FUTURE REFERENCE.
WATER & MOISTURE - DO NOT USE THE APPLIANCE NEAR WATER; IE. BATHTUB, WASHBOWL, KITCHEN SINK, LAUNDRY TUB, WET BASEMENT OR SWIMMING POOL.
VENTILATION - DO NOT SITUATE THE APPLIANCE SO THAT ITS LOCATION OR POSITION INTERFERES WITH ITS PROPER VENTILATION. FOR EXAMPLE, THE APPLIANCE SHOULD NOT BE SITUATED ON A BED, SOFA, RUG OR SIMILAR SURFACE THAT MAY BLOCK THE VENTILATION OPENINGS. THE APPLIANCE SHOULD NOT BE PLACED IN A BUILT-IN INSTALLATION, SUCH AS A BOOKCASE OR CABINET, THAT MAY IMPEDE THE FLOW OF AIR THROUGH THE VENTILATION OPENINGS.
HEAT - SITUATE THE APPLIANCE AWAY FROM HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTERS, STOVES OR OTHER APPLIANCES (INCLUDING AMPLIFIERS) THAT PRODUCE HEAT.
POWER SOURCES - CONNECT THE APPLIANCE ONLY TO A POWER SUPPLY TYPE DESCRIBED IN THE OPERATING INSTR-UCTIONS OR MARKED ON THE APPLIANCE.
GROUNDING OR POLARIZATION - PRECAUTIONS SHOULD BE TAKEN SO THAT THE GROUNDING OR POLARIZATION MEANS OF THE APPLIANCE ARE NOT DEFEATED.
!
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, SO NOT EXPOSE THIS APPLIANCE
TO RAIN OR MOISTURE.
POWER CORD PROTECTION - POWER SUPPLY CORDS SHOULD BE ROUTED SO THAT THEY ARE NOT LIKELY TO BE WALKED ON OR PINCHED BY ITEMS PLACED UPON OR AGAINST THEM, PAYING PARTICULAR ATTENTION TO CORDS AT PLUGS, CONVENIENCE RECEPTACLES, AND THE POINT WHERE THEY EXIT FROM THE APPLIANCE.
CLEANING - THE APPLIANCE SHOULD BE CLEANED ONLY AS RECOMMENDED BY THE MANUFACTURER.
NON USE PERIODS - UNPLUG THE APPLIANCE POWER CORD FROM THE OUTLET WHEN LEFT UNUSED FOR A LONG PERIOD OF TIME.
OBJECT & LIQUID ENTRY - CARE SHOULD BE TAKEN SO THAT OBJECTS DO NOT FALL AND LIQUIDS ARE NOT SPILLED INTO THE ENCLOSURE THROUGH OPENINGS.
DAMAGE REQUIRING SERVICE - THE APPLIANCE SHOULD BE SERVICED BY QUALIFIED SERVICE PERSONNEL WHEN: (A) THE POWER SUPPLY CORD OR THE PLUG HAS BEEN DAMAGED (B) OBJECTS HAVE FALLEN OR LIQUID HAS BEEN SPILLED INTO THE APPLIANCE (C) THE APPLIANCE HAS BEEN EXPOSED TO RAIN (D) THE APPLIANCE DOES NOT APPEAR TO BE OPERATING NORMALLY OR EXHIBITS A MARKED CHANGE IN PERFORMANCE (E) THE APPLIANCE HAS BEEN DROPPED OR THE ENCLOSURE DAMAGED.
SERVICING - THE USER SHOULD NOT ATTEMPT TO SERVICE THE APPLIANCE BEYOND THAT DESCRIBED IN THE OPERATING INSTRUCTIONS. ALL OTHER SERVICING REFER TO A QUALIFIED SERVICE PERSONNEL.
The exclamation point within a triangle is intended to tell the user that important operating and servicing instructions are in the papers with the appliance.
Ce produit n’est pas conçu pour un fonctionnement dans de forts champs électromagnétiques. Par conséquent, la qualité sonore peut
un fort champ életromagnétique. La qualité sonore redeviendra normale après affaib-lissement du champ électromagnétique.
diminuer si ce produit est exposé à
October 2008
Califone® International Inc. • 1145 Arroyo Avenue, # A • San Fernando, CA 91340 USA Toll Free 800.722.0500 | Toll Free Fax 877.402.2248 International Customers call 818.407.2400 or Fax 818.407.2405 califone.com
PA-IRSYS Operating Instructions
PA-IRSYS Infrared Classroom Audio System
A. Front Side View ( Open door )
(20)
(26)
(28)
(21)
(24)
(29)
(27)
(22)
(23)
(25)
(30) (31)
(32)
Control Panel Descriptions
Thank you for purchasing the Califone® PA-IRSYS Infrared Classroom Audio System.
We encourage you to visit our website www.califone.com to register your product for its warranty coverage, to sign up to receive our newsletter, download our catalog, and learn more about the complete line of Califone® audio visual products, including portable and installed wireless PA systems, multimedia players and recorders, headphones and headsets, computer peripheral equipment, visual presentation
products and language learning materials.
Unpacking the Unit
Inspect the unit once the packaging has been opened for any damage occurred during shipping & contact us immediately. Please keep the packing material for further use.
Warranty Registration
Califone warrants the Infrared Classroom Audio System to be free from defective material and workmanship for one year from the purchase date (six years for the speakers). Our “Project Intercept” Customer Satisfaction program will replace defective parts and repair malfunctioning equipment under this warranty when the defect occurs under normal use.
All Damage Claims Must Be Made With The Freight Carrier
Notify the freight carrier immediately if you observe any damage to the shipping carton or product. Repack the unit in the carton and await inspection by the carrier’s claim agent. Notify your dealer of the pending freight claim.
Returning Your Unit for Service or Repairs
Should your unit require service, contact our Customer Service Department online at califone.com/techsupport or via email warranty@califone.com or by phone at 800- 722-0500 / 818-407-2400 to rst obtain an RA number before returning it back to Califone. The unit must be returned to our factory via prepaid transportation only after the
factory issues an RA (Return Authorization) number which must be clearly written on the outside of the box.
Operating Instructions
PA-IRSYS Contents
Control Panel
Two Control Panel keys
AC Power cord
User Manual
• Two infrared ceiling sensors (PI30-SENSOR), each with an integrated 32’ connecting cable
• HBM-316 microphone used with beltpack transmitter
• Teacher Beltpack transmitter (PI30-BP)
• Beltpack lanyard with neck strap
• Student handheld microphone (PI30-HH)
• Four 1.2V AA Rechargeable NiMH batteries (for use with handheld and beltpack microphones)
• Two non-powered PI30-SP
PA-IRSYSB
• PA-IRSYS with two additional powered (PI30-PS) array speakers
Front View, Front Facing Panel
(For Sound Adjustments)
(3) (4)
(7) (8)
(11) (15)
(14)
(2)
(1)
(16) (17)
Front View, Inside Facing Panel
(For System Connections)
(30) (31)
(20)
(21)
(24)
(22 )
(26 )
(25)
(28)
(29)
(33)
Top View
(38)
Bottom View
(38 )
Vi si t u s on li n e at c al if o ne .c om
(34)
(23)
(27)
(32)
(35)
(36) (37 )
Front View Forward Facing Panel
(19)(5)(6) (9) (10)(1 3) (12)(18)
(1) Power Switch (2) Main Power Fuse (3.15A) (3) IR Teacher Mic Volume Control (4) IR Student Mic Volume Control (5) IR Signal Indicator (Teacher Mic) (6) IR Signal Indicator (Student Mic) (7) Mic 1 Volume Control (8) Mic 2 Volume Control (9) Aux 1 Volume Control (10) Aux 2 Volume Control (11) Treble Level Control (12) Bass Level Control (13) Master Volume Control (14) Beltpack Transmitter Recharging Station (15) Beltpack Transmitter Recharge Status Indicator (16) Power Adapter (17) Handheld Microphone Recharging Station & Status Indicator (18) Handheld Mic Holder (19) Door Lock
Front View Inside Panel
(20) Mic 1 Input (Balanced XLR) (21) Mic 2 Input (Unbalanced 1/4”) (22) Aux Input 1 (3.5mm) (23) Line Output (Mono 1/4”) (24) Aux Input 2 (Stereo RCA) (25) Mic Pre-out (Mono RCA) (26) DC 18V In (27) DC Out (28) Speaker Output (+ terminal) (29) Speaker Output (- terminal) (30) Infrared Ceiling Sensor Input (B) (31) Infrared Ceiling Sensor Input (A) (32) Cable Holder (33) Paging Input Volume Control (34) Paging Input Jack (35) 25V / 70V Paging Input Sensitivity Switch
Top and Bottom Views
(36) Panel Door (37) AC Input (38) Knockouts to feed wires through
1 2
Loading...
+ 4 hidden pages