Cabletron Systems TRFMIM-22, TRFMIM-26, TRFMIM-28 User Manual

TRFMIM-22, TRFMIM-26,
& TRFMIM-28
TOKEN RING FIBER
MEDIA INTERFACE MODULES
USER’S GUIDE
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505
NOTICE
NOTICE
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
© Copyright July 1993 by: Cabletron Systems, Inc. P.O. Box 5005 Rochester, NH 03867-0505
All Rights Reserved Printed in the United States of America
Order Number: 9030896 July 93
TRFMIM-22, TRFMIM-26, TRFMIM-28
trademarks of Cabletron Systems, Inc.
LANVIEW
Cabletron Systems, Inc.
IBM
is a registered trademark of International Business Machines
Corporation.
and
Remote LANVIEW
Printed on Recycled Paper
,
TRMM
are registered trademarks of
, and
MMAC
are
i
NOTICE
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING:
Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
DOC NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
ii
TABLE OF CONTENTS
TABLE OF CONTENTS
CHAPTER 1 INTRODUCTION
1.1 Using this Manual........................................................................ 1-1
1.2 The TRFMIM Concentrator Modules........................................ 1-2
1.3 Related Manuals........................................................................... 1-5
1.4 Recommended Reading .............................................................. 1-5
1.5 Getting Help ................................................................................. 1-5
CHAPTER 2 INSTALLATION REQUIREMENTS/
SPECIFICATIONS
2.1 Network Requirements............................................................... 2-1
2.2 Cable Specifications ..................................................................... 2-1
2.3 Operating Specifications ............................................................. 2-2
2.3.1 Ring Speed.......................................................................... 2-2
2.3.2 Ring Order .......................................................................... 2-3
2.3.3 LANVIEW LEDs................................................................ 2-3
2.3.4 General Specifications....................................................... 2-5
CHAPTER 3 INSTALLING THE CONCENTRATOR MODULE
3.1 Unpacking the Concentrator Module ....................................... 3-2
3.2 Configuring the Concentrator Module..................................... 3-3
3.3 Installing the Concentrator Module into the MMAC............. 3-3
3.4 Connecting Lobe Cabling............................................................ 3-4
3.5 Finishing the Installation ............................................................ 3-6
iii
TABLE OF CONTENTS
CHAPTER 4 TESTING AND TROUBLESHOOTING
4.1 Installation Checkout ...................................................................4-1
4.2 Using LANVIEW..........................................................................4-2
iv
CHAPTER 1
INTRODUCTION
INTRODUCTION
Welcome to the
Modules Installation Guide
TRFMIM Token Ring Fiber Media Interface
. This manual serves as a reference for installing and troubleshooting Cabletron Systems TRFMIM-22™, TRFMIM-26™, and TRFMIM-28™.
The TRFMIM is a fiber optic token ring concentrator module for use in the Cabletron MMACs. These concentrators are designed in compliance with the IEEE 802.5J token ring fiber optic standard. Available with six, twelve or eighteen ports, the TRFMIM provides connectivity over multimode fiber optic cable.
Note:
The term
Concentrator Module
is used throughout this manual when describing features and functions that are common to the TRFMIM-22, TRFMIM-26, and TRFMIM-28. The terms TRFMIM-22, TRFMIM-26, and TRFMIM-28 are used when it is necessary to describe features that are unique to any device.
1.1 USING THIS MANUAL
Prior to installing and operating your concentrator module, read through this manual completely to familiarize yourself with its contents and to gain an understanding of the features of the concentrator module.
A general working knowledge of Token Ring (IEEE 802.5) networks will be helpful when installing your concentrator module.
Chapter 1,
Introduction
, describes how to use this document, provides an overview of the features and capabilities of each concentrator module, and concludes with a list of related manuals.
Chapter 2,
Installation Requirements/Specifications
, lists the
network requirements that must be met before you begin installing
1-1
INTRODUCTION
your concentrator module. Detailed specifications for each of the concentrator modules is also provided.
Chapter 3,
Installing the Concentrator Module
, contains instructions for installing a concentrator module into the MMAC, and attaching token ring station cabling.
Chapter 4,
Testing and Troubleshooting
, describes checks that you can perform if you encounter problems after installing a concentrator module. Instructions for using LANVIEW®, Cabletron Systems built-in visual diagnostic and status monitoring system, are also included.
1.2 THE TRFMIM CONCENTRATOR MODULES
The TRFMIM-22, TRFMIM-26, and TRFMIM-28, shown in Figure 1-1, can be installed as a free-standing token ring network or to provide fiber optic connectivity to an existing token ring network. The concentrator modules are designed for installation into a Cabletron Systems MMAC. Since they do not have externally accessible Ring-In and Ring-Out ports, they are considered concentrator modules
. (A concentrator in token ring applications is defined as a device with multiple TCU ports bound by externally accessible Ring-In and Ring-Out ports.)
All concentrator modules are designed for installation into a Cabletron Systems MMAC, where they can be used to create an independent 6, 12, or 18 port ring or to expand an existing token ring network. When any concentrator module is used within an MMAC, the concentrator module is connected via the Flexible Network Bus (FNB) to other token ring MIMs, repeaters, or bridges.
1-2
INTRODUCTION
TRFMIM-26
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TRFMIM-22
FLNK
FLNK
FLNK
FLNK
FLNK
ERR
16 MBMGMT
FLNK
INS
1
7
FLNK
INS
2
8
FLNK
INS
3
9
FLNK
INS
4
10
FLNK
INS
5
11
ERR
16 MBMGMT
FLNK
INS
1
INS
TX
RX
FLNK
INS
2
INS
TX
RX
FLNK
INS
3
INS
TX
RX
FLNK
INS
4
INS
TX
RX
FLNK
INS
5
INS
TX
RX
TRFMIM-28
FLNK
INS
TX
13
RX
FLNK
INS
TX
14
RX
FLNK
INS
TX
15
RX
FLNK
INS
TX
16
RX
FLNK
INS
TX
17
RX
INS
INS
INS
INS
INS
MGMT 16 MB
FLNK
INS
7
FLNK
INS
8
FLNK
INS
9
FLNK
INS
10
FLNK
INS
11
ERR
FLNK
1
FLNK
2
FLNK
3
FLNK
4
FLNK
5
FLNK
FLNK
INS
INS
6
12
18
TX
RX
FLNK
TX
RX
FLNK
INS
INS
6
12
INS
TX
RX
FLNK
INS
6
FLNK
Figure 1-1 The TRFMIM Token Ring Concentrator Modules
1-3
Loading...
+ 17 hidden pages