Cabletron Systems CXRMIM, FORMIM-22, TPRMIM-20, TPRMIM-22, TPRMIM-33 Installation Manual

...
REPEATER MEDIA INTERFACE MODULES
(TPRMIM/FORMIM/CXRMIM)
INSTALLATION GUIDE
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03866-5005
NOTICE
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
© Copyright 1994 by: Cabletron Systems, Inc. P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved Printed in the United States of America
Order number: 9030679-02 October 94
Remote LANVIEW, LANVIEW, Multi Media Access Center
trademarks of Cabletron Systems, Inc.
EMME, EMM-E6, RMIM, CXRMIM, TPRMIM, FORMIM, EPIM-A, EPIM-X, EPIM-F, EPIM-T, MMAC-3FNB, MMAC-5FNB, MMAC-8FNB, MMAC-M8FNB, IRM, IRM2, IRM3, and IRBM
Windows CompuServe UNIX
are trademarks of Cabletron Systems, Inc.
is a registered trademark of Microsoft Corporation.
is a registered trademark of CompuServe, Inc.
is a registered trademark of UNIX System Laboratories, Inc.
Printed On
Recycled Paper
and
SPECTRUM
are registered
Installation Guide
i
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
DOC NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
CABLETRON SYSTEMS, INC.
PROGRAM LICENSE AGREEMENT
IMPORTANT: Before utilizing this product, carefully read this License Agreement.
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
ii
Repeater MIM
CABLETRON SOFTWARE PROGRAM LICENSE
1. LICENSE. package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron.
2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program.
3. APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
You have the right to use only the one (1) copy of the Program provided in this
EXCLUSION OF WARRANTY
AND DISCLAIMER OF LIABILITY
1. EXCLUSION OF WARRANTY. writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including Its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABLITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
Except as may be specifically provided by Cabletron in
2. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR ON THE DURATION OR LIMITATION OF IMPLIED WARRANTEES IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.
Installation Guide
iii
UNITED STATES GOVERNMENT
RESTRICTED RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at 252.227-
7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867.
SAFETY
It is the responsibility of the person who sells the system to which
WARNING
the TPRMIM, FORMIM, CXRMIM or EPIMs will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions.
Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC, TUV, VDE Class A. Meets FCC Part 15, Class A limits.
iv
Repeater MIM
CONTENTS
CHAPTER 1 Introduction
1.1 Using this Manual........................................................................1-2
1.2 Getting Help.................................................................................1-2
1.3 RMIM Overview...........................................................................1-3
1.4 RMIM Features............................................................................1-4
1.5 The Multimedia Access Centers with FNB..................................1-6
1.6 The EMME...................................................................................1-6
1.7 The EMM-E6 ...............................................................................1-8
1.8 Related Manuals..........................................................................1-9
CHAPTER 2 Installation Requirements and Specifications
2.1 Network Cable Requirements......................................................2-1
2.1.1 10BASE-2 Thin-Net Network Requirements .................2-1
2.1.2 10BASE-T Twisted Pair Network Requirements ...........2-2
2.1.3 FOIRL/10BASE-FL Multimode Fiber Optic
Network Requirements for the FORMIM .......................2-4
2.1.4 FOIRL/10BASE-FL Single Mode Fiber Optic
Network Requirements for the FORMIM .......................2-5
2.1.5 Transceiver/AUI Requirements for the
TPRMIM-36 ...................................................................2-6
2.2 RMIM Network Port Specifications..............................................2-7
2.2.1 TPRMIM-20/22 RJ45 Connector Specifications ............2-7
2.2.2 TPRMIM-33/36 Champ Connector Specifications .........2-7
2.2.3 CXRMIM Coaxial Connector Specifications ..................2-9
2.2.4 FORMIM-22, ST Connector Specifications ...................2-9
2.3 Operating Specifications............................................................2-11
CHAPTER 3 Installing the RMIM
3.1 Unpacking the RMIM...................................................................3-1
3.2 Setting the RMIM Jumpers for the CXRMIM,
FORMIM and TPRMIM................................................................3-2
3.2.1 Setting the Ethernet Jumpers ........................................3-3
3.2.2 Setting the Unmanaged Module Group Jumper ............3-3
3.3 Installing the RMIM into the MMAC.............................................3-5
3.3.1 Installing an EPIM ..........................................................3-7
3.4 Connecting the RMIM/EPIM to the Network................................3-9
3.4.1 Attaching Thin-Net Segments to the CXRMIM ..............3-9
3.4.2 Connecting a Thin-Net Segment to an EPIM-C ...........3-10
Installation Guide
v
Contents
3.4.3 Attaching a Twisted Pair Segment to the
TPRMIM-20/22 .............................................................3-12
3.4.4 Attaching a Twisted Pair Segment to the
TPRMIM-33/36 .............................................................3-13
3.4.5 Connecting a Twisted Pair Segment to an
EPIM-T .........................................................................3-14
3.4.6 Connecting a Fiber Optic Link Segment to a
FORMIM, EPIM-F1, EPIM-F2, or EPIM-F3 ..................3-16
3.4.7 Connecting an AUI Cable to an EPIM-A
or EPIM-X .....................................................................3-19
CHAPTER 4 Testing the RMIMs
4.1 Pre-Installation Test.....................................................................4-1
4.2 Installation Check-Out..................................................................4-2
APPENDIX A Twisted Pair Wiring Tables
APPENDIX B EPIM Specifications
INDEX
vi
Repeater MIM
CHAPTER 1
INTRODUCTION
Welcome to the Cabletron Systems’
(RMIM™) Installation Guide
Repeater Media Interface Module
. This manual is a reference guide for Cabletron’ s family of RMIMs. These modules incorporate the Repeater Interface Controller (RIC). The RIC is a multi-port repeater that enables the RMIMs to autonomously repeat packets without channeling them to a repeater module. The following RMIMs incorporate RIC technology:
TPRMIM-20™ & TPRMIM-22™ –
The TPRMIM-20 provides nine 10BASE-T RJ45 Unshielded Twisted Pair (UTP) ports and one slot for a Cabletron Systems Ethernet Port Interface Module (EPIM). The TPRMIM­22 provides twenty-one 10BASE-T RJ45 UTP ports and one EPIM slot.
TPRMIM-33™ & TPRMIM-36™
– The TPRMIM-33 has one 50-pin champ connector providing twelve 10BASE-T twisted pair ports and one EPIM slot. The TPRMIM-36 has two 50-pin champ connectors providing twenty-four 10BASE-T twisted pair ports, one AUI connector , and one EPIM slot.
CXRMIM™
– The CXRMIM is equipped with twelve 10BASE-2 coaxial
connectors and one EPIM slot.
FORMIM-22™ –
The FORMIM-22 is equipped with twelve
FOIRL/10BASE-FL ports with ST type connectors.
This manual uses the term RMIM when describing features and
NOTE
functions that are common to the TPRMIM-20, TPRMIM-22, TPRMIM-33, TPRMIM-36, CXRMIM, and FORMIM-22.
Installation Guide
1-1
Chapter 1:
INTRODUCTION
1.1 USING THIS MANUAL
Read this manual to gain a full understanding of the features and capabilities of the Cabletron Systems RMIMs. You should have a general w orking knowledge of Ethernet or IEEE 802.3 type data communications networks and their physical layer components before installing the RMIMs.
Chapter 1,
Introduction
, discusses the contents of this manual, briefly describes capabilities and special features of the RMIMs, and concludes with a list of related manuals.
Chapter 2,
Installation Requirements/Specifications
, describes installation requirements, network guidelines, and operating specifications for the RMIMs and EPIMs.
Chapter 3,
Installing the RMIM
, contains instructions for setting the RMIM jumpers and installing the RMIMs into the MMAC/FNB. This chapter also explains how to connect network segments to the RMIMs and EPIMs.
Chapter 4,
Testing the RMIMs,
provides procedures for testing and troubleshooting the installation of the RMIMs. It also explains how to use Cabletron Systems’ LANVIEW diagnostic and monitoring system.
Appendix A,
T wisted Pair Wiring Tables
, contains wiring pinouts for
Punchdown Block applications.
Appendix B,
EPIM Specifications
, provides specifications and switch settings
for the Ethernet Port Interface Modules (EPIMs).
1.2 GETTING HELP
If you need additional support related to the Cabletron Systems RMIMs, or if you have any questions, comments, or suggestions concerning this manual, contact Cabletron Systems Technical Support:
By phone ..............................(603) 332-9400
Monday-Friday; 8am - 8pm EST
By CompuServe®.................GO CTRON from any ! prompt
By Internet mail ...................support@ctron.com
1-2
Repeater MIM
RMIM OVERVIEW
1.3 RMIM OVERVIEW
Cabletron Systems Repeater Media Interface Modules provide connections to 10BASE-T, 10BASE-2, and FOIRL/10BASE-FL based Ethernet networks. Figure 1-1 shows each module.
RMIMs repeat, retime, and regenerate each packet ensuring data integrity and maximum data path distance. RMIMs also have a Fault Isolation feature that automatically segments problem ports from the network. When the problem port receives a good packet, the RMIM automatically reconnects the port to the network.
FORMIM-22
SN
ETHERNET
RCV LNK
TX
7
RX
RCV LNK
TX
8
RX
RCV LNK
TX
9
RX
RCV LNK
TX
10
RX
RCV LNK
TX
11
RX
RCV LNK
TX
12
RX
FOIRL/10BASE-FL
ETHERNET
B C
RCV LNK
RCV LNK
RCV LNK
RCV LNK
RCV LNK
RCV LNK
CLN POK
1
2
3
4
5
6
7
TPRMIM-33
SN
ETHERNET
1
2 3 4 5 6 7 8
9 10 11 12 13
10BASE-T ETHERNET
RCV POK
CXRMIM
SN
ETHERNET
8
9
10
11
12
13
RCV
POKRCV POKRCV
10BASE-2 ETHERNET
B C
CLN
1
2
3
4
5
6
B C
CLN
L
R
N
C
K
V
SN
14
15 16 17 18 19 20 21 22 23 24 25 26
14
1
13
26
15
2
TPRMIM-36
ETHERNET
CLN
1
RCV POK
2 3 4 5 6 7 8 9 10 11 12 13
L
R
N
C
K
V
10BASE-T ETHERNET
B C
RCV POK
R C V
CLN
L N K
TPRMIM-20
1
SN
13
2
ETHERNET
6 7 8 9
10
10BASE-T ETHERNET
TPRMIM-22
B C
LNK
CLN
RCV
POK
LNK
LNK RCV
11
RCV
12
1
13
2
14
3
15
4
16
5
17 18 19 20 21 22
E P
I
M
2 X
3 X
4 X
SN
5 X
6 X
7 X
8 X
9 X
1 0 X
ETHERNET
CLN
6 7 8 9
10
11 X
12
X
13
X
14
X
15
X
16
X
17
X
18
X
19
X
20
X
21
X
22
X
10BASE-T ETHERNET
B C
CLN
LNK
LNK
POK
RCV
RCV
1 2 3 4 5
E P
I
M
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X
10
X
Figure 1-1. Repeater Media Interface Modules
The RMIMs are designed, when managed by Cabletron’s Ethernet Management Module for Ethernet (EMME or EMM-E6), to provide you with the capability to add two additional Ethernet networks (B or C) to your existing Multi Media Access Center® (MMAC) over the Flexible Network Bus (FNB). Sections 1.5,
1.6 and 1.7 of this chapter describe features of the MMAC, the EMME and the EMM-E6.
Installation Guide
1-3
Chapter 1:
INTRODUCTION
1.4 RMIM FEATURES
Repeater Functionality
The RMIM IEEE 802.3 compliant repeater provides the MMAC with the ability to achieve maximum length data paths on each Ethernet network. To attain these maximum length data paths, the RMIM retimes data packets and regenerates the preamble of each data packet that enters the MMAC.
Additionally, the RMIM repeater functionality ensures that problem segments connected to any port on the MMAC/FNB will not affect any other segments connected to the MMAC/FNB. If 32 consecutive collisions are detected on any segment, or if a collision detector is on for more than 110 µs, the RMIM will automatically partition that segment from the MMAC/FNB. The segment will automatically be reconnected to the MMAC/FNB when a packet is recei v ed from the segment (or transmitted onto the segment, if using coaxial cable) without causing a collision.
RIC technology provides an inter-RIC bus that allows for communication between the RMIMs, allowing multiple RICs to be cascaded. The multiple RICs communicating over the RIC bus act as a single logical repeater. This is a significant advantage, since in the past, Ethernet networks were limited to four serially linked repeaters. W ith cascading RIC repeaters, each of which support 13 cable segments, you can build a much larger network than you could with stand­alone repeaters.
Unmanaged Grouped Module (Subnet) Capability
You can set Jumpers on the MMAC-installed RMIM to create an “unmanaged module group” of boards using the B or C channel. The RMIM and all boards to its left in the MMAC chassis no longer communicate across the FNB backplane to the EMME, EMM-E6 or any modules to the right of the unmanaged module group. This provides two additional “unmanaged” Ethernet networks. The networks cannot be seen or managed from the EMME or EMM-E6 installed in the MMAC. Section 3.2 describes how to set the RMIM jumpers.
Stand-alone Capability
You can also use the MMAC-installed RMIM as an “unmanaged” stand-alone repeater.
1-4
Repeater MIM
RMIM FEATURES
Remote Network Management Capabilities
You can manage the RMIMs remotely by any SNMP network management system. Cabletron Systems offers the following remote management packages:
Cabletron Systems SPECTRUM
®
Cabletron Systems Remote LANVIEW®/Windows™
SPECTRUM Portable Management Applications
Ethernet Port Interface Modules
Cabletron Systems’ Ethernet Port Interface Modules (EPIMs) provide additional connection to the Ethernet network. Table 1-1 describes each EPIM.
Table 1-1. EPIMs
EPIM MEDIA TYPE CONNECTOR
EPIM-A AUI DB15 (Female) EPIM-C 10BASE-2 Thin Coaxial BNC EPIM-T 10BASE-T Unshielded Twisted Pair RJ45 EPIM-X Standard Transcei v er DB15 (Male) EPIM-F1 Multimode Fiber SMA EPIM-F2 Multimode Fiber ST EPIM-F3 Single Mode Fiber ST
LANVIEW LEDs
The RMIMs incorporate LANVIEW, Cabletron Systems’ built-in diagnostic and status monitoring LED system. LANVIEW LEDs help you rapidly diagnose device, port, and link problems. You can also view Ethernet status LEDs to determine if the RMIM is running on Ethernet B, Ethernet C, or stand-alone mode. Chapter 4 describes each LED.
Installation Guide
1-5
Chapter 1:
INTRODUCTION
1.5 THE MULTI MEDIA ACCESS CENTERS WITH FNB
Cabletron Systems Multi Media Access Center with Flexible Network Bus (MMAC/FNB) provides three separately repeated Ethernet segments: Ethernets A, B, and C. The Cabletron Systems non-repeating Media Interface Modules (MIMs) operate on Ethernet A, while the RMIMs are designed to operate on Ethernet segments B and C. See Figure 1-2.
Power & Management Bus
Ethernet A Bus
Flexible Network Bus
Ethernet B Bus
Ethernet C Bus
Figure 1-2. MMAC with FNB
The modular design of the MMAC allows the RMIMs to co-exist with other MIMs to provide a variety of different media connections at one point. This means that the RMIM can be used by itself or in conjunction with any combination of other MIMs accommodating Twisted Pair, Fiber Optic Cable, Thick or Thin Ethernet Coaxial Cabling, or AUI Cabling. Figure 1-3 shows a sample configuration.
1.6 THE EMME
The Ethernet Management Module for Ethernet (EMME) provides management, bridging, and routing (optional feature) for four Ethernet channels; channels A, B, and C on the MMAC backplane and channel D from the EMME AUI port. The four EMME channels access the same shared memory so that packets received on one channel can be forwarded to any or all of the other channels.
1-6
Repeater MIM
THE EMME
The EMME uses Ethernet Channel A on the MMAC backplane to transmit and receive data from Cabletron Systems non-repeater MIMs (i.e., TPMIMs, FOMIMs, THN-MIMs). The EMME provides repeater functionality for these MIMs.
TPMIM-24
Channel A
CXRMIMFORMIM-22FORMIM-22TPMIM-24
Channel B Channel C
TPRMIM-33
TPRMIM-36
EMME
Channel D
Ethernet channels B and C transmit and receive packets over the Repeater Interface Controller (RIC) management bus on the FNB to Cabletron Systems RMIMs (TPRMIM, FORMIM, and CXRMIM). RMIMs can repeat packets autonomously without channeling them through the EMME.
Two redundant AUI ports on the EMME’s front panel let you access Ethernet channel D. The AUI ports allow you to connect the module to a variety of Ethernet transmission media including twisted pair, fiber optic, or thick or thin Ethernet coaxial cable.
Installation Guide
Figure 1-3. Ethernets A, B, and C
1-7
Chapter 1:
INTRODUCTION
When using the Cabletron Systems EMME along with the RMIMs, you have the network management capabilities that enable you to control the RMIM and its attached segments. For example, you can gather information on the number of good packets and collisions that pass through each port on the RMIM.
1.7 THE EMM-E6
The EMM-E6 (Ethernet Management Module) is a six port bridge/router module with four Ethernet bridge/router ports and two user selectable bridge/router ports. The EMM-E6 provides management, bridging, and routing for three Ethernet channels; channels A, B, and C on the MMAC backplane and a fourth external Ethernet segment (channel D) via an Ethernet Port Interface module (EPIM). Two Bridge/Router Interface Module (BRIM) ports can be configured to pro vide additional bridging or feeder node routing on Ethernet, Token Ring, FDDI, ATM or Wide Area Networks (WAN).
The EMM-E6 uses Ethernet Channel A on the MMAC backplane to transmit and receive data from Cabletron Systems non-repeater MIMs (i.e., TPMIMs, FOMIMs, THN-MIMs). The EMM-E6 provides repeater functionality for these MIMs.
Ethernet channels B and C transmit and receive packets over the Repeater Interface Controller (RIC) management bus on the FNB to Cabletron Systems RMIMs (TPRMIM, FORMIM, and CXRMIM). RMIMs can repeat packets autonomously without channeling them through the EMM-E6.
The EMM-E6 provides two slots for optional EPIMs on the front panel. The EPIMs provide an Ethernet D channel for various transmission media connections (twisted pair, fiber optic, and thick or thin Ethernet coaxial cable). Using two EPIMs provides redundancy for the external network connection but note that only one EPIM operates at any given time.
The two Bridge Router Interface Modules (BRIMs) perform the same bridging functions as EPIMs, however, unlike EPIMs, BRIMs bridge packets from one transmission type to another (e.g., Ethernet to FDDI, ATM to Wide Area, etc.).
1-8
Repeater MIM
RELATED MANUALS
1.8 RELATED MANUALS
The manuals listed below should be used to supplement the procedures and other technical data provided in this manual. The procedures in them will be referenced, where appropriate, but will not be repeated.
Cabletron Systems’
Multi Media Access Center (MMAC-M8FNB, MMAC-
5FNB, MMAC-M3FNB) Overview and Set Up Guide
Cabletron Systems’
Cabletron Systems’
Ethernet Management Module (EMME) User’s Guide
EMM-E6 Installation Guide
Installation Guide
1-9
Chapter 1:
INTRODUCTION
1-10
Repeater MIM
CHAPTER 2
INSTALLATION
REQUIREMENTS/SPECIFICATIONS
This Chapter describes cable requirements, network guidelines, and operating specifications for the RMIMs. Be sure that you read this chapter before you install the RMIMs. Your network must meet the requirements and conditions specified in this chapter to obtain satisfactory performance from this equipment. Failure to follow these guidelines could result in poor network performance.
2.1 NETWORK CABLE REQUIREMENTS
Take care in planning and preparing the cabling and connections for your network. The quality of the connections and the length of cables are critical factors in determining the reliability of your network. The following sections describe cable requirements for each media type.
2.1.1 10BASE-2 Thin-Net Network Requirements
When connecting a 10BASE-2 thin-net coaxial segment to the CXRMIM or EPIM-C, your network must meet the following requirements:
Cable Type
50 ohm RG-58A/U type coaxial cable must be used when making up a thin-net cable segment.
Length
The thin-net segment must be no longer than 185 meters.
Terminators
A 50 ohm terminator must be connected to the far end of each thin-net segment.
Installation Guide
2-1
Chapter 2: INSTALLATION REQUIREMENTS/SPECIFICATIONS
Connectors
A maximum of 29 tee-connectors may be used throughout the length of cable segment for host connections. If an excessive number of barrel connectors are used within the cable segment, such as finished wall plates with BNC feed-throughs, then a reduced number of host connections may be required. For special network design, contact Cabletron Systems Technical Support.
Grounding
For safety, ground only one end of a thin-net segment. Do NOT connect EPIM or CXRMIM BNC ports to earth ground.
Connecting a thin-net segment to earth ground at more than one
WARNING
point could produce dangerous ground currents. The BNC ports of the CXRMIM are connected to earth ground, eliminating the need of grounding the segments connected to the BNC ports. The EPIM­C provides a switch to select either internal or external termination.
2.1.2 10BASE-T Twisted Pair Network Requirements
When connecting a 10BASE-T Twisted Pair Segment to a TPRMIM-20/22/33/36 or EPIM-T, your network must meet the following requirements:
Length
The IEEE 802.3 10BASE-T standard requires that 10BASE-T devices transmit over a 100 meter (328 foot) link using 22-24 AWG unshielded twisted pair wire. However, cable quality largely determines maximum link length. If you use high quality, low attenuation cable, you can achieve link lengths of up to 200 meters. Cable delay limits maximum link length to 200 meters, regardless of the cable type.
Insertion Loss
The maximum insertion loss allowed for a 10BASE-T link is 11.5 dB at all frequencies between 5.0 and 10 MHz. This includes the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the link segment.
Impedance
Cabletron Systems 10BASE-T Twisted Pair products will work on twisted pair cable with 75 to 165 ohms impedance. Unshielded twisted pair cables typically have an impedance of between 85 to 110 ohms.
2-2 Repeater MIM
NETWORK CABLE REQUIREMENTS
Shielded twisted pair cables, such as IBM Type 1 cable, can also be used. You should remember that the impedance of IBM Type 1 cable is typically 150 ohms. This increases the signal reflection caused by the cable, but since the cable is shielded, this signal reflection has little effect on the receiv ed signal’s quality due to the lack of crosstalk between the shielded cable pairs.
Jitter
Intersymbol interference and reflections can cause jitter in the bit cell timing, resulting in data errors. A 10BASE-T link must not generate more than 5.0 nsec of jitter. If your cable meets the impedance requirements for a 10BASE-T link, jitter should not be a concern.
Delay
The maximum propagation delay of a 10BASE-T link segment must not exceed 1000 nsec. This 1000 nsec maximum delay limits the maximum link segment length to no greater than 200 meters.
Crosstalk
Crosstalk is caused by signal coupling between the different cable pairs contained within a multi-pair cable bundle. 10B ASE-T transceivers are designed so that the user does not need to be concerned about cable crosstalk, provided the cable meets all other requirements.
Noise
Noise can be caused by either crosstalk or externally induced impulses. Impulse noise may cause data errors if the impulses occur at very specific times during data transmission. Generally, the user need not be concerned about noise. If noise-related data errors are suspected, it may be necessary to either reroute the cable or eliminate the source of the impulse noise.
Temperature
Multi-pair PVC 24 AWG telephone cables typically have an attenuation of approximately 8 to 10 dB/100m at 20°C (68°F). The attenuation of PVC insulated cable varies significantly with temperature. At temperatures greater than 40°C (104°F), we strongly recommend that you use plenum-rated cables to ensure that cable attenuation remains within specification.
Installation Guide 2-3
Chapter 2: INSTALLATION REQUIREMENTS/SPECIFICATIONS
2.1.3 FOIRL/10BASE-FL Multimode Fiber Optic Network Requirements for the FORMIM
When connecting a multimode fiber optic segment to a FORMIM-22, EPIM-F1, or EPIM-F2, your network must meet the following requirements:
Table 2-1. Multimode Fiber Optic Cable Specifications
Cable Type Attenuation Maximum Cable Length
50/125 µm 13.0 dB or less
The maximum allowable fiber
62.5/125 µm 16.0 dB or less
optic cable length is 2 km (2187.2 yards).
100/140 µm 19.0 dB or less
Attenuation
You must test the fiber optic cable with a fiber optic attenuation test set adjusted for an 850 nm wavelength. This test verifies that the signal loss in a cable is within an acceptable level. Table 2-1 shows the attenuation for each Multimode cable type.
Fiber Optic Budget and Propagation Delay
When determining the maximum fiber optic cable length, the fiber optic budget delay and total network propagation should be calculated and taken into consideration before fiber optic cable runs are incorporated in any network design.
Fiber optic budget is the combination of the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors.
Propagation delay is the amount of time it takes data to travel from the sending device to the receiving device. Total propagation delay allowed for the entire network is 25.6 µsec, if the total propagation delay between any two nodes on the network exceeds 25.6 µsec, then bridges should be used.
2-4 Repeater MIM
NETWORK CABLE REQUIREMENTS
2.1.4 FOIRL/10BASE-FL Single Mode Fiber Optic Network Requirements for the FORMIM
When connecting a single mode fiber optic segment to an EPIM-F3, your network must meet the following requirements:
Table 2-2. Single Mode Fiber Optic Cable Specifications
Cable Type Attenuation Maximum Cable Length
8/125-12/125 µm 10.0 dB or less The maximum allowable fiber
optic cable length is 5 km (3.1 miles) with bridges at each segment end. However, IEEE 802.3 FOIRL specifica­tions specify a maximum of 1 km (1093.6 yards).
Attenuation
You must test the fiber optic cable with a fiber optic attenuation test set adjusted for a 1300 nm wavelength. This test verifies that the signal loss in a cable is 10.0 dB or less for any given single mode fiber optic link.
Fiber Optic Budget and Propagation Delay
Fiber optic budget is the combination of the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors. When determining the maximum fiber optic cable length, the fiber optic budget (total loss of 10.0 dB or less between stations) and total network propagation delay should be calculated and considered before fiber optic cable runs are incorporated in any network design.
Propagation delay is the amount of time it takes data to travel from the sending device to the receiving device. Total propagation delay allowed for the entire network is 25.6 µsec, if the total propagation delay between any two nodes on the network exceeds 25.6 µsec, then bridges should be used.
Installation Guide 2-5
Chapter 2: INSTALLATION REQUIREMENTS/SPECIFICATIONS
2.1.5 Transceiver/AUI Requirements for the TPRMIM-36
To connect external network segments to the EPIM-A, EPIM-X, or the AUI port on the TPRMIM-36, you need an AUI cable. The TPRMIM-36 and EPIM-A require a transceiver to connect to the segment. The EPIM-X has built-in dual transceivers and can be connected directly to the segment. The EPIM-X is used primarily for connecting cascading devices.
When connecting an external network segment to a TPRMIM-36, EPIM-A, or EPIM-X, your network must meet the following requirements:
Transceiver/Ethernet Device (EPIM-A/TPRMIM-36)
The transceiver or Ethernet De vice to which the EPIM-A or TPRMIM-36 will be connected must meet IEEE 802.3 standards, and/or Ethernet Version 1.0 or Version 2.0 requirements.
AUI Cable
The A UI cable connecting the module to a device must be IEEE 802.3 type cable.
Length
The AUI Cable must not exceed 50 meters in length. If 28 AWG thin office drop AUI cable is used, then the maximum cable length is limited to 50 feet (15.24 meters).
Grounding
The connector shell of the EPIM-A and the EPIM-X are connected to earth ground.
2-6 Repeater MIM