Cabletron Systems 9E531-24 User Manual

SmartSwitch 9000
9E531-24
24 Port 10BASE-FL Ethernet Module
User’s Guide
9033274
Notice
NOTICE
The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR
CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Cabletron Systems, Inc. 35 Industrial Way Rochester, NH 03867
1999 by Cabletron Systems, Inc.
All Rights Reserved Printed in the United States of America
Order Number: 9033274
Cabletron Systems, SPECTRUM, LANVIEW, and MicroMMAC are re gis tered t rademar ks and SmartSwitch is a trademark of Cabletron Systems, Inc.
All other product name s me nt ioned in this manual may be trademarks or registered trademarks of their respective compan ies.
FCC NOTICE
This device complies with Part 15 of the FCC ru le s . Operation is subject to the following two conditions: (1) this device may not cause harmful interference , and (2) this device must accept any interfe rence received, including interf erence that may cause unde sired ope ration.
NOTE: This equipment has been tested and found to comply with the lim it s for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent. This equipm ent uses, generates, and can radiate radio frequency energy and if not installed in acco rdance with the
operator’s manual, may cause harmful interference to radio communication s. Ope r a ti on of this equipment in a resi de ntial area is likely to cause interference in whi ch case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparat us set out i n the Ra dio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlem ent sur le brouillage radioé le ctrique édicté par le min ist ère des Communications du Ca nada.
VCCI NOTICE
This is a Class A product based on th e sta n dard of the Voluntary Control Council for Interference by Informa ti on Technology Equ ipment (VCCI). If this equipment is used in a domestic environment, radi o disturbance may arise. Wh e n such trouble occurs, the user m ay be required to take corrective actions.
i
Notice
CABLETRON SYSTEMS, INC.
PROGRAM LICENSE AGREEMENT
IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS:
CANADA MEXICO CENTRAL AMERICA SOUTH AMERICA
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT.
This document is an agre em ent (“Agreement”) between You, the end user, and Cabletron Systems, Inc. (“Cabletron”) that set s forth your rights and obligations with respect to the Cable tron software program (“Progr am ” ) in th e package. The Program m ay be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INC LUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO CABLETRON OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT CABLETRON SYSTEMS +1-603-332-9400. Attn: Legal Department.
1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions
of this License Agreement. You may not copy, reproduce or transmit any part of the Progr am except as permitted by the Copyright Act of the United States or as
authorized in writing by Cabletron.
2. OTHER RESTRICTIONS. You may not reverse engineer, decom pil e , or di sasse m ble the Program.
3. APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of
New Hampshire. You accept the perso nal jurisdiction and venue of th e New Hampshire courts.
4. EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S.
Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain tec hnical products to certain countries, unless a license to export the product is obt ain e d from the U.S. Government or an exc eption from obtaining suc h li cense may be relied upon by the export ing party.
If the Program is exported fro m the United States pursuant to th e License Exception CIV under the U.S. Export Administ ration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes.
If the Program is exported fro m the United States pursuant to th e License Exception TSR under the U.S. Export Admini s tration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, Y ou agree not to (i) reexport or release the Program, the source code for t he Program or technology to a na ti onal of a country in Country Groups D: 1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China, Romania, R ussia , R wanda , Tajikistan, Turkmenistan, Ukraine, Uzbe kist an, Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produce d direct product is subject to nat io n al sec urity controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a com plete plant o r any major compo nent of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a ma jor component thereof , if such foreign produced direct pro duc t is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was devel oped solely at private expense;
(ii) contains “restr ic ted computer software” subm i tt ed with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Cabletron and/or its suppliers. For Department of Defense units, th e Product is considered commercial computer softwar e in accordance with DFARS section 227.7202-3 and its succe ssors, and use, dupl ic ation, or disclosure by the Govern m ent is subj ec t to restrictions set forth herein.
ii
Notice
6. EXCLUSION OF WARRANTY. Except as may be spec ifically provided by Cabletron in writing, Cable tron makes no warranty,
expressed or implied, conce rni ng t he Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PR OGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
7. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE
FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU.
CABLETRON SYSTEMS SALES AND SERVICE, INC.
PROGRAM LICENSE AGREEMENT
IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY
This document is an agre em ent (“Agreement”) between You, the end user, and Cabletron Systems Sales and Service, Inc. (“Cabletron”) that sets forth your rights and obl iga ti ons with respect to the Cabletron software program (“Program”) in the package. The Program may be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO CABLETRON OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT CABLETRON SYSTEMS +1-603-332-9400. Attn: Legal Department.
UNITED STATES OF AMERICA GOVERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE
AGREEMENT.
1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions
of this License Agreement. You may not copy, reproduce or transmit any part of the Progr am except as permitted by the Copyright Act of the United States or as
authorized in writing by Cabletron.
2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Prog ra m.
3. APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of
New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
4. EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S.
Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain tec hnical products to certain countries, unless a license to export the product is obt ain e d from the U.S. Government or an exc ep ti on from obtaining such license may be relied upon by the exporting party.
If the Program is exported fro m the United States pursuant to th e License Exception CIV under the U.S. Export Administ rat io n Regulations, You agree that Y ou are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes.
If the Program is exported from th e United States pursuant to the Li ce nse Exc eption TSR under the U.S. Ex port Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, Y ou agree not to (i) reexport or release the Program, the source code for t he Program or technology to a na ti onal of a country in Country Groups D: 1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China, Rom ania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Progr am or the technology, if such foreign produce d direct product is subject to national security controls as identified on the U.S. Commerce Cont rol Li st, or (iii) if the direct product of the technology is a complete pla nt o r any major component of a plant,
iii
Notice
export to Country Groups D:1 or E:2 the direct product of the plant or a ma jor component thereof , if such foreign produced direct pro duc t is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was devel oped solely at private expense;
(ii) contains “restr ic ted computer software” subm i tt ed with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Cabletron and/or its suppliers. For Department of Defense units, th e Product is considered commercial computer softwar e in accordance with DFARS section 227.7202-3 and its succe ssors, and use, dupl ic ation, or disclosure by the Govern m ent is subj ec t to restrictions set forth herein.
6. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty,
expressed or implied, conce rni ng t he Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING,
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRAN TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PR OGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
7. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE
FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU.
CABLETRON SYSTEMS LIMITED
PROGRAM LICENSE AGREEMENT
IMPORTANT: THIS LICENSE APPLIES FOR THE USE OF THE PRODUCT IN THE FOLLOWING GEOGRAPHICAL
REGIONS:
EUROPE MIDDLE EAST AFRICA ASIA AUSTRALIA PACIFIC RIM
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT.
This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems Limited (“Cabletron”) that sets forth
your rights and obligations with respect to the Cable tron software program (“Progr am ” ) in th e package. The Program m ay be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INC LUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO CABLETRON OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT CABLETRON SYSTEMS +1-603-332-9400. Attn: Legal Department.
1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions
of this License Agreement. You may not copy, reproduce or transmit any part of the Progr am except as permitted by the Copyright Act of the United States or as
authorized in writing by Cabletron.
2. OTHER RESTRICTIONS. You may not reverse engineer, decom pil e , or di sasse m ble the Program.
3. APPLICABLE LAW. This License Agreement shall be governed in accordance with English law. The English courts shall have
exclusive jurisdict ion in the event of any disput es.
iv
Notice
4. EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S.
Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain tec hnical products to certain countries, unless a license to export the product is obt ain e d from the U.S. Government or an exc ep ti on from obtaining such license may be relied upon by the exporting party.
If the Program is exported fro m the United States pursuant to th e License Exception CIV under the U.S. Export Administ rat io n Regulations, You agree that Y ou are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes.
If the Program is exported from th e United States pursuant to the Li ce nse Exc eption TSR under the U.S. Ex port Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, Y ou agree not to (i) reexport or release the Program, the source code for t he Program or technology to a na ti onal of a country in Country Groups D: 1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova,
North Korea, the People’s Republic of China, Rom ania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Progr am or the technology, if such foreign produce d direct product is subject to national security controls as identified on the U.S. Commerce Cont rol Li st, or (iii) if the direct product of the technology is a complete pla nt o r any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was devel oped solely at private expense;
(ii) contains “restr ic ted computer software” subm i tt ed with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Cabletron and/or its suppliers. For Department of Defense units, th e Product is considered commercial computer softwar e in accordance with DFARS section 227.7202-3 and its succe ssors, and use, dupl ic ation, or disclosure by the Government is subject to restrictions set fo r th herein.
6. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty,
expressed or implied, conce rni ng t he Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PR OGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
7. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE
FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU.
v
Notice
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
THE 9H539-24 MODULE USES CLASS 1 LASER TRANSCEIVERS.
READ THE FOLLOWING SAFETY INFORMATION BEFORE
INSTALLING OR OPERATING THESE MODULES.
The Class 1 laser transceivers use an optic al feedback loop to mai ntain Class 1 operation limit s . This control loop elimina te s the need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers comply with the following safety standard s:
• 21 CFR 1040.10 and 1040.11 U. S. Department of Health and Human S erv ic es (FDA).
• IEC Publication 825 (International Electrotechnical Commission).
• CENELEC EN 60825 (European Committee for El ec tro technical Standardiz ation). When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit of all three
standards. Class 1 levels of laser radiation are not considered hazardous.
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
LASER RADIATION AND CONNECTORS
When the connector is in place, all la s er radiation remains w it h in the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10
Removing the optical connector from the transc eiver allows laser radiation to emit directly from the optical port. The maximum ra di ance from the optical po rt (under worst case condit ions) is
0.8 W cm
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.
-2
or 8 x 103 W m2 sr-1.
-6
watts.
vi
DECLARATION OF CONFORMITY
Application of Cou ncil Directive(s): 89/336/EEC
73/23/EEC
Manufacturer’s Name: Cabletron Systems, Inc.
Manufacturer’s Address: 35 Industrial Way
PO Box 5005 Rochester, NH 03867
European Representative Name: Mr. J. Solari
European Representative Address: Cabletron Systems Limited
Nexus House, New bury Business Park London Road, Newbury Berkshire RG14 2PZ, England
Conformance to Directive(s)/Product Stan dards: EC Directive 89/336/EEC
EC Directive 73/23/EEC EN 55022 EN 50082-1 EN 60950
Equipment Type/Environment: Networking Equipment, for use in a Commercial or Light Industrial
Environment.
Notice
W e the undersigne d, hereby declare, under our sole re sponsibility, that the equipment pac kaged with this no ti ce conforms to the above directives.
Manufactur er Legal Representative in Eur op e Mr. Ronald Fotino Mr. J. Solari
___________________________________ ___________________________________
Full Name Full Name Compliance Enginee ri ng Manager Managing Direct or - E. M .E.A.
___________________ ________________ ___________________________________
Title Title Rochester, NH, USA Newbury, Berkshire, England
___________________________________ ___________________________________
Location Location
vii
Notice
viii
Chapter 1 Introduction
Features .......................................................................................................................... 1-1
Related Manuals............................................................................................................1-7
Getting Help .............................. ...... ....................................... ...... .................................1-8
Chapter 2 Installing the SmartSwitch 9000 Module
Unpacking the Module ................................................................................................2-1
User Accessible Components...................................................................................... 2-1
Using DIP Switch 6................................................................................................2-4
Installing the Module into the SmartSwitch 9000 Chassis......................................2-4
The Reset Switch ...........................................................................................................2-6
Cabling Requirements..................................................................................................2-6
10BASE-FL Network............................................................................................. 2-6
Chapter 3 Technical Overview
Contents
SmartSwitch Architecture............................................................................................ 3-1
System Management Buses......................................................................................... 3-2
SMB-1 Bus....................................................... ...... ...... ....................................... .....3-3
SMB-10 Bus.............................................................................................................3-3
System Diagnostic Controller......................................................................................3-3
DC/DC Converter........................................................................................................3-3
INB Interface..................................................................................................................3-4
i960 Core.........................................................................................................................3-4
Chapter 4 LANVIEW LEDs
Chapter 5 Specifications
Technical Specifications ........................................................................................ 5-1
CPUs.................................................................................................................5-1
Memory............................................................................................................ 5-1
Network Interface........................................................................................... 5-1
Performance ....................................................................................................5-1
Regulatory Compliance ................................................. ...... ..... ...... ...... ................5-2
Service.......................................................................... ..... ...... .................................5-2
Physical ...................................................................................................................5 -2
ix
Contents
Dimensions......................................................................................................5-2
Weight...............................................................................................................5-2
Environment....................................................................................................5-2
x

Introduction

The 9E531-24 shown in Figure 1-1, is a 10BASE-FL Ethernet switching module for Cabletron Systems SmartSwitch 9000 chassis, providing 24 MT-RJ MMF ports.
The 9E531-24 can be used to connect individual 10 BASE-FL user devices and servers.

Features

Connectivity
The 9H532-24 connects to Ethernet networks or workstations through the 24 MTRJ ports on the front panel. These ports are IEEE 802.1D and 802.3 10BASE-FL compliant. The ports support Multimode fiber cables with attenuation of less than or equal to 3.75 dB/Km, when measured at a wavelength of 850 nm.
Chapter 1
1-1
Introduction
ETHERNET
9E531-24
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1-2
Figure 1-1. The 9E531-24
Introduction
Duplex Mode
Through Local Management, each port on the 9E531-24 can be configured to support either full or half duplex mode of operation.
Runtime IP Address Discovery
This feature enables the modules to automatically accept an IP address from a Boot Strap Protocol (BootP) server on the network into NVRAM without requiring a user to enter an IP address through Local Management.
When the modules are connected to the network and powered up, Runtime IP Address Discovery (RAD) checks the modules for an IP addr ess. If one has not yet been assigned (module and SmartSwitch 9000 chassis IP address set to 0.0.0.0), RAD checks to see if any of the module interfaces have a link. If so, RAD sends out Reverse Address Resolution Protocol (RARP) and BootP requests to obtain an IP address from a RARP or BootP server on the network.
The RAD requests start at an interval of one per second. The interval then doubles after every transmission until an interval of 300 seconds is reached. At this point, the interval remains at 300 seconds. The RAD requests continue until an IP address is rec eived fr om a RARP or BootP server, or an IP address is enter ed using Local Management.
SmartTrunk
SmartTrunk, also referred to as SmartTrunking, is Cabletron Systems’ terminology for load balancing or load sharing. SmartTrunk technology provides an easy-to-implement mechanism to group, or aggregate, multiple links of any technology together to scale the backbone bandwidth beyond the limitations of a single link. All links are user-configurable so administrators can scale the backbone bandwidth by adding SmartTrunk links. The benefits of SmartTrunking include the following:
All purchased bandwidth is used.
Distributed, resilient links increase reliability and performance.
Multiple technologies are supported within a single trunk for maximum flexibility.
For information on SmartTrunk configuration, refer to the
NOTE
SmartTrunk User’s Guide.
1-3
Introduction
Management
Management of the 9E531-24 module and SmartSwitch chassis and any optional equipment is accomplished using the Local Management application or remote SNMP management stations. Local Management is accessible through the RS232 COM port on the Environmental Module using a local VT100 terminal, or a remote VT100 terminal via a modem connection, and in-band via a Telnet connection. In-band remote management is possible through Webview or any SNMP compliant Network Management Software.
Local Management provides the ability to manage the 9E531-24. Local Management information for non-Eth ernet HSIMs or VHSIMs is incl uded in t heir
respective user’s guide. For details on how to get manuals, refer to the Related Manuals section in the Introduction.
WebView
The 9E531-24 modules can be managed by Cabletron WebView, a browser-based utility. There is no software to install as this management capability is b uilt into each module.
Remote Monitoring (RMON)
The 9E531-24 supports all nine Ethernet RMON groups. The Statistics, Alarms, Events and History groups are enabled on all ports by default.
Cabletron Systems RMON Actions is a vendor-specific extension of RMON and provides the ability to s et an “Action ” on any SNMP MIB variabl e. The Action can be triggered by setting an RMON Event and/or Alarm. An example of an Action would be to turn off a MIB-2 interface if a broadcast threshold is crossed.
Broadcast Suppression
Broadcast Suppression enables a user to set a desired limit of receive broadcast frames per port/per second to be forwarded out the other ports on the module up to the set limit. Any broadcast frames above this specified limit are dropped. In the event that broadcast frames are being suppressed, multicast and unicast frames continue to be switched.
Port Redirect Function
The Port Redirect function, also referred to as “Port Mirroring,” is a troubleshooting tool used to map traff ic from a single source port to a destination port within the chassis. This feature allows all packets, including those with errors, to be copied and sent to an analyzer or RMON probe. The analyzer or RMON probe will see the data as i f it is directly connected to the LAN segment of the source port.
Flow Control
Flow Control is a method of managing the flow of frames between two devices. It ensures that a transmitting device does not overwhelm a receiving device with data. This enables the receiving device to communicate with the transmitting
1-4
Introduction
device, and to have it pause its transmission while the receiving device processes the frames already receive d. Flow contro l can be e nabled or disabl ed on a port-by­port basis. Both devices must support the IEEE 802.3x standard for flow control to work.
The 9E531-24 supports the following two types of flow control:
frame based 802.3x
back pressure
Frame based 802.3x flow control is supported on all Ethernet ports operating in the full duplex mode.
Back pressure flow control is supported on all Ethernet ports operating in the standard mode of operation.
802.1p Port Priority
The IEEE 802.1p standard is used to assign a default priority to the frames received without priority information in their tag header, and to map prioritized frames to the appropriate transmit queues.
The default priority-to-queue mappings are shown in Table 1-1. This configuration can be changed by the admi nistrator.
Table 1-1. Priority Queuing Configuration
Priority Indicator Transmit Queue
73 63 52 42 31 20 10 01
Switching Options
The 9E531-24 provides IEEE Standard-based 802.1 switching or SecureFast Switching Virtual Network Services. In the 802.1 mode (the default mode of operation), the switch functions as an 802.1D switch. When VLANs are configured, it operates as an 802.1Q switch.
1-5
Introduction
Standards Compatibility
The 9E531-24 is fully compliant with the IEEE 802.3, 802.3x, 802.1Q, and 802.1p standards. The 9E531-24 provides IEEE 802.1D Spanning Tree Algorithm (STA) support to enhance the overall reliability of the network and protect against
“loop” conditions. The 9E531-24 supports a wide variety of industry standard MIBs including RFC 1573 (MIB II), RFC 1271 (RMON), RFC 1493 (Bridge MIB), RFC 1354 (FIB MIB), and RFC 1190 (Path MTU Discovery). A full suite of Cabletron Systems Enterprise MIBs pr ovide a wide array of st atistical i nformation to enhance troubleshooting.
For information about how to extract and compile individual MIBs, contact Cabletron Systems.
GARP Switch Operation
Some or all ports on the switch may be activated to operate under the Generic Attribute Registration Protocol (GARP) applications, GARP VLAN Registration Protocol (GVRP) and/or GARP Multicast Registration Protocol (GMRP).
GARP is a protocol, or set of rules, that outlines a mechanism for propagating the port state and/or user information throughout a bridged LAN to keep track of users and VLANs on the network fabric. MAC bridges and end users alike can take part in the registration and d e-r egistration of GARP attributes such as VLAN and multicast group membership.
LANVIEW Diagnostic LEDs
LANVIEW diagnostic LEDs serve as an important troubleshooting aid by providing an easy way to observe the status of individual ports and overall network operations.
Year 2000 Compliance
The 9E531-24 module and the SmartSwitch 9000 chassis have an internal clock that can maintain the time and date beyond the year 1999.
1-6

Related Manuals

The Cabletron Systems manuals listed below should be used to supplement the procedures and technical data contained in this manual.
SmartSwitch 9000 Installation Guide
SmartSwitch 9000 9C300-1 Environmental Module User’s Guide SmartSwitch 9000 9C214-1 AC Power Supply User’s Guide SmartSwitch 9000 9X5XX Series Local Management User’s Guide Cabling Guide Ethernet Technology Guide Network Troubleshooting Guide WebView User’s Guide SmartTrunk User’s Guide
Introduction
1-7
Introduction

Getting Help

For additional support related to this device or document, contact Cabletron Systems using one of the following methods:
World Wide Web http://www.cabletron.com/ Phone (603) 332-9400 Internet mail support@cabletron.com FTP ftp://ftp.cabletron.com/
Login Password
To send comments or suggestions concerning this document, contact the Cabletron Systems Technical Writing Department via the following email address: TechWriting@cabletron.com
Make sure to include the document Part Number in the email message.
Before calling Cabletron Systems, have the following information ready:
Your Cabletron Systems service contract number
anonymous your email address
A description of the failure
A description of any action(s) already taken to resolve the problem (e.g., changing mode switches, rebooting the unit, etc.)
The serial and revision numbers of all involved Cablet ron Systems pr oducts in the network
A description of your network environment (layout, cable type, etc.)
Network load and frame size at the time of trouble (if known)
The device history (i.e., have you r eturned the device befor e, is this a r ecurring problem, etc.)
Any previous Return Material Authorization (RMA) numbers
1-8
Chapter 2

Installing the SmartSwitch 9000 Module

Only qualified personnel should perform installation procedures.

Unpacking the Module

1. Carefully remove the module from the shipping box. (Save the box and
packing materials in the event the module must be reshipped.)
2. Remove the module from the plastic bag. Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
3. Carefully examine the module, checking for damage. If any damage exists,
DO NOT install the module. Contact Cabletron Systems immediately.

User Accessible Components

Figure 2-1 shows the various components that are accessible to the user. These consist of an eight-position DIP switch, replaceable PROMs and soc kets for RAM. These components will be used for future upgrades. Instr uctions for installi ng the components will be supplied with the upgrade kit.
2-1
Installing the SmartSwitch 9000 Module
SMB-1
PROM
i960 Processor
32 MB DRAM
Flash SIMM
Socket
1 2 3 4 5 6 7 8
DIP Switch
Figure 2-1. User-Accessible Components
Boot PROM
2-2
Installing the SmartSwitch 9000 Module
An eight-position DIP switch is located on the module card as shown in Figure 2-1. The function of the switches are listed in Table 2-1.
See the Cautions at the end of this table.
Table 2-1. Function of DIP Switch
Switch Function Description
When toggled, this switch clears user-entered
8
7
Clear
Password
Clear
NVRAM
passwords stored in NVRAM, and restores the
1
default passwords. Once reset you can use the defaults or enter new passwords.
The module uses NVRAM to store user­entered parameters such as IP addresses, device name, etc. To reset these parameters to the factory defaults, toggle this switch. Once
2
reset, you can use the defaults or enter new parameters, which are stored in NVRAM when the module is powered down, and remain there until the switch is toggled again.
!
CAUTION
Toggling this switch after pul ling the board out of the SmartSwitch 9000, clears download information from NVRAM and forces image
6
5 Reserved For Factory Use Only
4 Reserved For Factory Use Only
3 Reserved For Factory Use Only
2 Reserved For Factory Use Only
1 Reserved For Factory Use Only
Force BootP
Download
files to be downloaded from the station connected to the EPIM on the Environmental
Module configured to act as that modules’
ootP server. (See section titled Using DIP
B Switch 6 on page 2-4.)
1. Caution: Do not toggle Switch 8 unless you intend to reset the user-
configured passwords to their factory default settings.
2. Caution: Do not t oggle Switch 7 unless you intend to reset the user
parameters to the factory default settings.
2-3
Installing the SmartSwitch 9000 Module

Using DIP Switch 6

The purpose of DIP switch 6 is to force a Flash download from a BootP server through the EM-EPIM. The first step in this process is to configure the BootP server. Configurations of BootP servers can differ from platform to platform and
from one operating system to another. Read the user’s manual on BootP and TFTP serving for the correct files to edit and the correct files to execute for the server. After configuration of the BootP server the module can then have the switch state changed on dip switch 6 to initiate BootP and TFTP requests.
When the state of dip switch 6 is changed, the module begins requesting a BootP server in an attempt to receive a Flash ima ge download. The modules boot PROM initiates a BootP sequence. During this sequence, the module requests an IP address and a filename from the BootP server. The module then requests a TFTP of the file and receives the download of the image. The module will not function until the Flash image is downloaded from the BootP and TFTP server.
If a BootP and TFTP are not intended at this time, this process may be stopped by resetting the module. Resetting is done by pushing the reset button on the module, power cycling the chassis, or removing the module from the chassis and re-inserting. (See section titled module again looks for a BootP server, but will time-out after about f our min utes. After the time-out, the module boots from Flash memory. The next time the power is cycled, the module will boot from Flash memory and not request the BootP server.
The Reset Switch on page 2-6.) After resetting, the

Installing the Module into the SmartSwitch 9000 Chassis

To install the SmartSwitch 9000 module, follow the steps below:
NOTE
1. Remove the blank panel covering the two slots in which the module is being
2. Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000
2-4
The INB Terminator Modules must be installed on the rear of the fourteen slot chassis before powering up this module. The INB Terminator Modules are not required on the six slot chassis. Refer to the INB Terminator Modules Installation Guide for information and installation procedure.
installed. All other slots must be covered, if other modules are not being installed, to ensure proper airflow and cooling.
chassis to your wrist. Plug the other end into the ESD Wrist Strap Grounding receptacle in the lower right corner of the SmartSwitch 9000 chassis shown in Figure 2-2.
Installing the SmartSwitch 9000 Module
3. Grasp the module and slide it into the slots. Make sure that the module’s
circuit card is bet ween the card guides, as shown in Figure 2-2. Check both the upper and lower tracks of the car d. Take care that the module slides in straight and engages the backplane connectors properly.
4. Lock down the top and bottom plastic tabs, as shown in Figure 2-2.
7
FLNK
8
FLNK
FLNK
10
RX
FLNK
INS
TX
11
RX
FLNK
INS
TX
12
RX
Metal Back- Panel
Circuit Card
Card Guides
Warning:
Ensure that the circuit card is between the card guides.
Lock down the top and bottom plastic tabs
at the same time, applying even pressure
Figure 2-2. Installing the 9E531-24 Module
Jack for ESD wrist strap
.
2-5
Installing the SmartSwitch 9000 Module

The Reset Switch

The Reset switch is located under the top plastic tab as shown in Figure 2-3.
Use the reset switch to reset the module’ s processor, shutdown (power down) the module, and/or restart the module.
To reset the module’s i960 processor, press the reset switch twice within three seconds.
To shut down the module, press and hold the reset switch for three or more seconds.
To restart the module, press the reset switch momentarily.
SNMP management may be used to disable this switch to enhance module security.
Reset Switch
Figure 2-3. The Reset Switch

Cabling Requirements

10BASE-FL Network

The 9E531-24 supports 10BASE-FL Ethernet specifications. When connecting a 10BASE-FL segment to any of the front panel ports, ensure that the network meets the optical performance requirements for the 10BASE-FL 802.3 standard.
The 9E531-24 supports multimode fiber cables at the 850nm wavelength, at lengths up to 2 km.
SMB
CPU
2-6

Technical Overview

SmartSwitch Architecture

The SmartSwitch Architecture of the 9E531-24 module, as shown in Figure 3-1, is configurable for one of two modes of operation: traditional IEEE 802.1 switching, or SecureFast switching. The module supports only one of these modes of operation at any one time.
When operating in traditional IEEE 802.1 switch mode, the 9E531-24 makes filtering/forwarding decisions based on Destination Addr ess (DA), with standard IEEE 802.1D learning. 802.1Q VLANs are also supported.
Spanning tree operation for the 9E531-24 is config urable to adher e to IEEE 802.1D , DEC, or none. The default Spanning Tree Algorithm is 802.1D.
Chapter 3
When operating in SecureFast switch mode, al l filtering/forwar ding decis ions are made on a DA-SA pair and its in and out port on a connection-orientated basis. SecureFast switching mode provides value-added network services including dynamic VLANs, Topology, Connectivity, IP Multicast, Control, Security, Application, Address Management, Dynamic Mapping, and Directory services. For example, Topology Services includes configurable options ranging from simple spanning tree implementations to fully-meshed active topologies. Other services and features supported in SecureFast switching mode are described in detail in the Cabletr on W hite Paper, IP Host Communication in Bridged, Routed and SecureFast Networks.
3-1
Technical Overview
Figure 3-1. Block Diagram

System Management Buses

There are two management channels within the SmartSwitch 9000 system: the SMB-1 and the SMB-10. These buses provide out-of-band management and inter-module management communication.
3-2

SMB-1 Bus

The SMB-1 is a 1 Mbps management bus located within the SmartSwitch 9000. This bus is utilized by all diagnostic controllers in the system including connectivity modules, power supply modules and the environmental module. The SMB-1 transports inter-chassis information between system components, such as power and environmental information, as well as diagnostic messages. Periodic loop-back tests are performed by all modules that share this bus to ensure the validity of SMB-1. In the event a failure is detected on SMB-1, the SMB-10 may be used as an alternate communication channel.

SMB-10 Bus

The SMB-10 is a 10 Mbps management bus located within the SmartSwitch 9000, which is also used for inter-chassis communication of modules as well as serving as an out-of-band management ch annel i nto the SmartSwitc h 9000 . The SMB-10 is externalized from the chassis via an optional Ethernet Port Interface Module (EPIM) located on the front of the Environ mental Module. Through an EPIM connection, full SNMP management of the SmartSwitch 9000 is available out-of­band from user data. Modules which share the SMB-10 bus periodically send out loop-back packets to ensure the validit y of SMB-10. In t he event a fault is detected on the SMB-10, the SMB-1 can be used as an alternate communication chan nel by the modules.
Technical Overview

System Diagnostic Controller

This diagnostic controller is composed of a Z-80 microprocessor and its supporting logic. The diagnostic controller is designed to control the power-up sequencing of modules, monitor the 9E531-24 input and output power parameters, keep watch over the main host processor, as well as monitor the temperature and control the SMB LANVIEW diagnostic LED. Although the diagnostic controller and the main host processor can operate independent of
each other if needed, they exchange information about each other’s status and overall module condition. The information gathered by the diagnostic controller is available to the network manager via local/remote management and the LCD located on the Environmental Module. Th e 9E531- 24 has been designed so that in the event of a diagnostic controller fault, the 9E531-24 will continue to function.

DC/DC Converter

The DC/DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network se rvices module . The di agnostic controller monitors and controls the operation of the DC/DC converter.
3-3
Technical Overview

INB Interface

Each module attaches to both INB A and INB B and has two INB ASICs. The INB ASICs use 64-byte Ethernet frames for transmission onto the INBs at 66 MHz.
The 9X5XX modules are fully compatible with the the first generation 9X4XX modules. The first generation modules communicate only on INB B using a 56-byte canonical frame format, at 40 MHz. If the newer module detects a first generation module on the backplane, it automatically changes from the fast 66 MHz Ethernet frames, to the first generation compatible 40 MHz canonical frame on INB B only. INB A is used only by the 9X5XX modules and remains at the higher speed.

i960 Core

The i960 core provides modules host services, the SNMP protocol stacks, to support industry standard MIBs, as well as Cabletron enterprise extension MIBs for each media type. Management services, such as telnet , WebV ie w and network address to MAC address mapping, are also provided by the i960 core.
3-4

LANVIEW LEDs

The front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. Figure 4-1 shows the LANVIEW LEDs of the 9E531-24 module.
Chapter 4
ETHERNET
9E531-24
System Status
INB Receive
INB Transmit
24
23
22
21
20
19
18
17
Figure 4-1. The 9E531-24 LANVIEW LEDs
Ethernet Receive
Ethernet Transmit
4-1
LANVIEW LEDs
The functions of the two System Status LEDs, System Management Bus (SMB) and the CPU, are listed in Table 4-1.
Table 4-1. System Status (SMB and CPU) LEDs
LED Color State Description
Green Functional Fully operational Yellow Testing Power-up testing Yellow (Flashing) Crippled Not fully operational (e.g., one bad port) Yellow/Green Booting Blinks yellow and green while booting Red Reset Normal power-up reset Red (Flashing) Failed Fatal error has occurred Off Power off Module powered off
The functions of the INB transmit LED are listed in Table 4-2.
Table 4-2. INB Transmit LED
LED Color State
Green (Flashing) Data activity Ye llow (Flashing) Port in standby state Red (Flashing) Collision Red Fault Off No activity, Port disabled
The functions of the INB receive LED are listed in Table 4-3.
Table 4-3. INB Receive LED
LED Color State
Green (Flashing) Link, Port disabled
4-2
Green Link, Port enabled, No activity Yellow (Flashing) Link, Port enabled, Activity Red Fault Off No Link
LANVIEW LE Ds
The functions of the Ethernet Transmit and Ethernet Receive LEDs are listed in Table 4-4 and Table 4-5.
Table 4-4. Ethernet Transmit LEDs
Color State
Green (Flashing) Activity (Flashing rate indicates rate of activity) Ye llow (Flashing) Port in standby state Red Port disabled Red (Flashing) Collision Off No activity
Table 4-5. Ethernet Receive LEDs
LED Color State
Green Link, No activity Yellow (Flashing) Link, Activity (Flashing rate indicates rate of activity) Red Port disabled no link Red (Flashing) Port disabled with link Off No link, No activity
4-3
LANVIEW LEDs
4-4

Specifications

Technical Specifications

CPUs

PowerPC Intel i960 RISC based microprocessor

Memory

8 MB Flash Memory (expandable to 16 MB) 32 MB DRAM (local) 4 MB Memory (Shared)
Chapter 5

Network Interface

24 MT-RJ multimode fiber ports - 10BASE-FL

Performance

Module Switch Fabric bandwidth 3.3 Gbps Module Throughput 2.2 Mpps Source Address Table 16 K entries
5-1
Specifications

Regulatory Compliance

It is the respo nsibi lit y of the per son who sells th e syste m to whic h the modu le will
!
CAUTION
This equipment meets the following safety and electromagnetic compatibility (EMC) requirement s:
Safety UL 1950, CSA C22.2 No. 950,
be a part to ensure that the total system meets allowed limits of conducted and radiated emissions.
EN 60950, IEC 950, and 73/23/EEC

Service

Physical

Dimensions

Weight

Electromagnetic Compatibility (EMC)
MTBF (MHBK-217E) >200,000 hrs. MTTR <0.5 hr.
35.0 D x 44.0 H x 3.0 W centimeters
(13.8 D x 17.4 H x 1.2 W inches)
Unit: 4.5 kg (10 lb) Shipping: 5.4 kg (12 lb)
FCC Part 15, EN 55022, CSA C108.8, EN 50082-1, AS/NZS 3548, VCCI V-3, and 89/336/EEC

Environment

5-2
Operating Temperature 5 to 40° C (41° to 104°F) Storage Temperature -30 to 73° C (-22° to 164°F) Relative Humidity 5% to 90% non-condensing
Loading...