Cabletron Systems reser ves the ri ght to make changes in specifications and other information conta ined in this document with out prior
notice. The reader shoul d in all cases consult Cabletron Systems to determine whe th er a ny such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR
CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR
RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN
ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Cabletron Systems, Inc.
35 Industrial Way
Rochester, NH 03867
1999 by Cabletron Systems, Inc.
All Rights Reserved
Printed in the United States of America
Order Number: 9033274
Cabletron Systems, SPECTRUM, LANVIEW, and MicroMMAC are re gis tered t rademar ks and SmartSwitch is a trademark of Cabletron
Systems, Inc.
All other product name s me nt ioned in this manual may be trademarks or registered trademarks of their respective compan ies.
FCC NOTICE
This device complies with Part 15 of the FCC ru le s . Operation is subject to the following two conditions: (1) this device may not cause
harmful interference , and (2) this device must accept any interfe rence received, including interf erence that may cause unde sired ope ration.
NOTE: This equipment has been tested and found to comply with the lim it s for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environm ent. This equipm ent uses, generates, and can radiate radio frequency energy and if not installed in acco rdance with the
operator’s manual, may cause harmful interference to radio communication s. Ope r a ti on of this equipment in a resi de ntial area is likely to
cause interference in whi ch case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparat us set out i n the Ra dio Interference
Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A
prescrites dans le Règlem ent sur le brouillage radioé le ctrique édicté par le min ist ère des Communications du Ca nada.
VCCI NOTICE
This is a Class A product based on th e sta n dard of the Voluntary Control Council for Interference by Informa ti on Technology Equ ipment
(VCCI). If this equipment is used in a domestic environment, radi o disturbance may arise. Wh e n such trouble occurs, the user m ay be
required to take corrective actions.
i
Notice
CABLETRON SYSTEMS, INC.
PROGRAM LICENSE AGREEMENT
IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS:
CANADA
MEXICO
CENTRAL AMERICA
SOUTH AMERICA
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE
AGREEMENT.
This document is an agre em ent (“Agreement”) between You, the end user, and Cabletron Systems, Inc. (“Cabletron”) that set s forth
your rights and obligations with respect to the Cable tron software program (“Progr am ” ) in th e package. The Program m ay be contained in
firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE
TERMS OF THIS AGREEMENT, WHICH INC LUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER
OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO
CABLETRON OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL
REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT CABLETRON SYSTEMS +1-603-332-9400. Attn: Legal
Department.
1.LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions
of this License Agreement.
You may not copy, reproduce or transmit any part of the Progr am except as permitted by the Copyright Act of the United States or as
authorized in writing by Cabletron.
2.OTHER RESTRICTIONS. You may not reverse engineer, decom pil e , or di sasse m ble the Program.
3.APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of
New Hampshire. You accept the perso nal jurisdiction and venue of th e New Hampshire courts.
4.EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S.
Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain tec hnical products to certain
countries, unless a license to export the product is obt ain e d from the U.S. Government or an exc eption from obtaining suc h li cense may be
relied upon by the export ing party.
If the Program is exported fro m the United States pursuant to th e License Exception CIV under the U.S. Export Administ ration
Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for
military purposes.
If the Program is exported fro m the United States pursuant to th e License Exception TSR under the U.S. Export Admini s tration
Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, Y ou agree not to (i) reexport or release the
Program, the source code for t he Program or technology to a na ti onal of a country in Country Groups D: 1 or E:2 (Albania, Armenia,
Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova,
North Korea, the People’s Republic of China, Romania, R ussia , R wanda , Tajikistan, Turkmenistan, Ukraine, Uzbe kist an, Vietnam, or such
other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the
direct product of the Program or the technology, if such foreign produce d direct product is subject to nat io n al sec urity controls as identified
on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a com plete plant o r any major compo nent of a plant,
export to Country Groups D:1 or E:2 the direct product of the plant or a ma jor component thereof , if such foreign produced direct pro duc t is
subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S.
Munitions List.
5.UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was devel oped solely at private expense;
(ii) contains “restr ic ted computer software” subm i tt ed with restricted rights in accordance with section 52.227-19 (a) through (d) of the
Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Cabletron
and/or its suppliers. For Department of Defense units, th e Product is considered commercial computer softwar e in accordance with DFARS
section 227.7202-3 and its succe ssors, and use, dupl ic ation, or disclosure by the Govern m ent is subj ec t to restrictions set forth herein.
ii
Notice
6.EXCLUSION OF WARRANTY. Except as may be spec ifically provided by Cabletron in writing, Cable tron makes no warranty,
expressed or implied, conce rni ng t he Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING,
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PR OGRAM, THE ACCOMPANYING WRITTEN MATERIALS,
AND ANY ACCOMPANYING HARDWARE.
7.NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE
FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS,
BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE
DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF
CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE
DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS
MAY NOT APPLY TO YOU.
CABLETRON SYSTEMS SALES AND SERVICE, INC.
PROGRAM LICENSE AGREEMENT
IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY
This document is an agre em ent (“Agreement”) between You, the end user, and Cabletron Systems Sales and Service, Inc. (“Cabletron”) that
sets forth your rights and obl iga ti ons with respect to the Cabletron software program (“Program”) in the package. The Program may be
contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND
BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND
DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED
PRODUCT TO CABLETRON OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A
FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT CABLETRON SYSTEMS +1-603-332-9400. Attn: Legal
Department.
UNITED STATES OF AMERICA GOVERNMENT END USERS.
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE
AGREEMENT.
1.LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions
of this License Agreement.
You may not copy, reproduce or transmit any part of the Progr am except as permitted by the Copyright Act of the United States or as
authorized in writing by Cabletron.
2.OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Prog ra m.
3.APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of
New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
4.EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S.
Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain tec hnical products to certain
countries, unless a license to export the product is obt ain e d from the U.S. Government or an exc ep ti on from obtaining such license may be
relied upon by the exporting party.
If the Program is exported fro m the United States pursuant to th e License Exception CIV under the U.S. Export Administ rat io n
Regulations, You agree that Y ou are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for
military purposes.
If the Program is exported from th e United States pursuant to the Li ce nse Exc eption TSR under the U.S. Ex port Administration
Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, Y ou agree not to (i) reexport or release the
Program, the source code for t he Program or technology to a na ti onal of a country in Country Groups D: 1 or E:2 (Albania, Armenia,
Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova,
North Korea, the People’s Republic of China, Rom ania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such
other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the
direct product of the Progr am or the technology, if such foreign produce d direct product is subject to national security controls as identified
on the U.S. Commerce Cont rol Li st, or (iii) if the direct product of the technology is a complete pla nt o r any major component of a plant,
iii
Notice
export to Country Groups D:1 or E:2 the direct product of the plant or a ma jor component thereof , if such foreign produced direct pro duc t is
subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S.
Munitions List.
5.UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was devel oped solely at private expense;
(ii) contains “restr ic ted computer software” subm i tt ed with restricted rights in accordance with section 52.227-19 (a) through (d) of the
Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Cabletron
and/or its suppliers. For Department of Defense units, th e Product is considered commercial computer softwar e in accordance with DFARS
section 227.7202-3 and its succe ssors, and use, dupl ic ation, or disclosure by the Govern m ent is subj ec t to restrictions set forth herein.
6.EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty,
expressed or implied, conce rni ng t he Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING,
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRAN TIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PR OGRAM, THE ACCOMPANYING WRITTEN MATERIALS,
AND ANY ACCOMPANYING HARDWARE.
7.NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE
FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS,
BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE
DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF
CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE
DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS
MAY NOT APPLY TO YOU.
CABLETRON SYSTEMS LIMITED
PROGRAM LICENSE AGREEMENT
IMPORTANT: THIS LICENSE APPLIES FOR THE USE OF THE PRODUCT IN THE FOLLOWING GEOGRAPHICAL
REGIONS:
EUROPE
MIDDLE EAST
AFRICA
ASIA
AUSTRALIA
PACIFIC RIM
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE
AGREEMENT.
This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems Limited (“Cabletron”) that sets forth
your rights and obligations with respect to the Cable tron software program (“Progr am ” ) in th e package. The Program m ay be contained in
firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE
TERMS OF THIS AGREEMENT, WHICH INC LUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER
OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO
CABLETRON OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL
REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT CABLETRON SYSTEMS +1-603-332-9400. Attn: Legal
Department.
1.LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions
of this License Agreement.
You may not copy, reproduce or transmit any part of the Progr am except as permitted by the Copyright Act of the United States or as
authorized in writing by Cabletron.
2.OTHER RESTRICTIONS. You may not reverse engineer, decom pil e , or di sasse m ble the Program.
3.APPLICABLE LAW. This License Agreement shall be governed in accordance with English law. The English courts shall have
exclusive jurisdict ion in the event of any disput es.
iv
Notice
4.EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S.
Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain tec hnical products to certain
countries, unless a license to export the product is obt ain e d from the U.S. Government or an exc ep ti on from obtaining such license may be
relied upon by the exporting party.
If the Program is exported fro m the United States pursuant to th e License Exception CIV under the U.S. Export Administ rat io n
Regulations, You agree that Y ou are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for
military purposes.
If the Program is exported from th e United States pursuant to the Li ce nse Exc eption TSR under the U.S. Ex port Administration
Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, Y ou agree not to (i) reexport or release the
Program, the source code for t he Program or technology to a na ti onal of a country in Country Groups D: 1 or E:2 (Albania, Armenia,
Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova,
North Korea, the People’s Republic of China, Rom ania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such
other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the
direct product of the Progr am or the technology, if such foreign produce d direct product is subject to national security controls as identified
on the U.S. Commerce Cont rol Li st, or (iii) if the direct product of the technology is a complete pla nt o r any major component of a plant,
export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is
subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S.
Munitions List.
5.UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was devel oped solely at private expense;
(ii) contains “restr ic ted computer software” subm i tt ed with restricted rights in accordance with section 52.227-19 (a) through (d) of the
Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Cabletron
and/or its suppliers. For Department of Defense units, th e Product is considered commercial computer softwar e in accordance with DFARS
section 227.7202-3 and its succe ssors, and use, dupl ic ation, or disclosure by the Government is subject to restrictions set fo r th herein.
6.EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty,
expressed or implied, conce rni ng t he Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING,
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PR OGRAM, THE ACCOMPANYING WRITTEN MATERIALS,
AND ANY ACCOMPANYING HARDWARE.
7.NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE
FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS,
BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE
DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF
CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE
DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS
MAY NOT APPLY TO YOU.
v
Notice
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
THE 9H539-24 MODULE USES CLASS 1 LASER TRANSCEIVERS.
READ THE FOLLOWING SAFETY INFORMATION BEFORE
INSTALLING OR OPERATING THESE MODULES.
The Class 1 laser transceivers use an optic al feedback loop to mai ntain Class 1 operation limit s . This control loop elimina te s the need for
maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers comply with
the following safety standard s:
• 21 CFR 1040.10 and 1040.11 U. S. Department of Health and Human S erv ic es (FDA).
• IEC Publication 825 (International Electrotechnical Commission).
• CENELEC EN 60825 (European Committee for El ec tro technical Standardiz ation).
When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit of all three
standards. Class 1 levels of laser radiation are not considered hazardous.
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
LASER RADIATION AND CONNECTORS
When the connector is in place, all la s er radiation remains w it h in the fiber. The maximum amount of radiant power exiting the fiber (under
normal conditions) is -12.6 dBm or 55 x 10
Removing the optical connector from the transc eiver allows laser radiation to emit directly from the optical port. The maximum ra di ance
from the optical po rt (under worst case condit ions) is
0.8 W cm
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard.
When viewing the output optical port, power must be removed from the network adapter.
-2
or 8 x 103 W m2 sr-1.
-6
watts.
vi
DECLARATION OF CONFORMITY
Application of Cou ncil Directive(s): 89/336/EEC
73/23/EEC
Manufacturer’s Name: Cabletron Systems, Inc.
Manufacturer’s Address: 35 Industrial Way
PO Box 5005
Rochester, NH 03867
European Representative Name: Mr. J. Solari
European Representative Address: Cabletron Systems Limited
Nexus House, New bury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England
Conformance to Directive(s)/Product Stan dards: EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 50082-1
EN 60950
Equipment Type/Environment: Networking Equipment, for use in a Commercial or Light Industrial
Environment.
Notice
W e the undersigne d, hereby declare, under our sole re sponsibility, that the equipment pac kaged with this no ti ce conforms to the
above directives.
Manufactur erLegal Representative in Eur op e
Mr. Ronald FotinoMr. J. Solari
The 9E531-24 shown in Figure 1-1, is a 10BASE-FL Ethernet switching module for
Cabletron Systems SmartSwitch 9000 chassis, providing 24 MT-RJ MMF ports.
The 9E531-24 can be used to connect individual 10 BASE-FL user devices and
servers.
Features
Connectivity
The 9H532-24 connects to Ethernet networks or workstations through the 24
MTRJ ports on the front panel. These ports are IEEE 802.1D and 802.3 10BASE-FL
compliant. The ports support Multimode fiber cables with attenuation of less than
or equal to 3.75 dB/Km, when measured at a wavelength of 850 nm.
Chapter 1
1-1
Introduction
ETHERNET
9E531-24
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1-2
Figure 1-1. The 9E531-24
Introduction
Duplex Mode
Through Local Management, each port on the 9E531-24 can be configured to
support either full or half duplex mode of operation.
Runtime IP Address Discovery
This feature enables the modules to automatically accept an IP address from a
Boot Strap Protocol (BootP) server on the network into NVRAM without
requiring a user to enter an IP address through Local Management.
When the modules are connected to the network and powered up, Runtime IP
Address Discovery (RAD) checks the modules for an IP addr ess. If one has not yet
been assigned (module and SmartSwitch 9000 chassis IP address set to 0.0.0.0),
RAD checks to see if any of the module interfaces have a link. If so, RAD sends
out Reverse Address Resolution Protocol (RARP) and BootP requests to obtain an
IP address from a RARP or BootP server on the network.
The RAD requests start at an interval of one per second. The interval then doubles
after every transmission until an interval of 300 seconds is reached. At this point,
the interval remains at 300 seconds. The RAD requests continue until an IP
address is rec eived fr om a RARP or BootP server, or an IP address is enter ed using
Local Management.
SmartTrunk
SmartTrunk, also referred to as SmartTrunking, is Cabletron Systems’
terminology for load balancing or load sharing. SmartTrunk technology provides
an easy-to-implement mechanism to group, or aggregate, multiple links of any
technology together to scale the backbone bandwidth beyond the limitations of a
single link. All links are user-configurable so administrators can scale the
backbone bandwidth by adding SmartTrunk links. The benefits of SmartTrunking
include the following:
•All purchased bandwidth is used.
•Distributed, resilient links increase reliability and performance.
•Multiple technologies are supported within a single trunk for maximum
flexibility.
For information on SmartTrunk configuration, refer to the
NOTE
SmartTrunk User’s Guide.
1-3
Introduction
Management
Management of the 9E531-24 module and SmartSwitch chassis and any optional
equipment is accomplished using the Local Management application or remote
SNMP management stations. Local Management is accessible through the RS232
COM port on the Environmental Module using a local VT100 terminal, or a
remote VT100 terminal via a modem connection, and in-band via a Telnet
connection. In-band remote management is possible through Webview or any
SNMP compliant Network Management Software.
Local Management provides the ability to manage the 9E531-24. Local
Management information for non-Eth ernet HSIMs or VHSIMs is incl uded in t heir
respective user’s guide. For details on how to get manuals, refer to the Related
Manuals section in the Introduction.
WebView
The 9E531-24 modules can be managed by Cabletron WebView, a browser-based
utility. There is no software to install as this management capability is b uilt into
each module.
Remote Monitoring (RMON)
The 9E531-24 supports all nine Ethernet RMON groups. The Statistics, Alarms,
Events and History groups are enabled on all ports by default.
Cabletron Systems RMON Actions is a vendor-specific extension of RMON and
provides the ability to s et an “Action ” on any SNMP MIB variabl e. The Action can
be triggered by setting an RMON Event and/or Alarm. An example of an Action
would be to turn off a MIB-2 interface if a broadcast threshold is crossed.
Broadcast Suppression
Broadcast Suppression enables a user to set a desired limit of receive broadcast
frames per port/per second to be forwarded out the other ports on the module up
to the set limit. Any broadcast frames above this specified limit are dropped. In
the event that broadcast frames are being suppressed, multicast and unicast
frames continue to be switched.
Port Redirect Function
The Port Redirect function, also referred to as “Port Mirroring,” is a
troubleshooting tool used to map traff ic from a single source port to a destination
port within the chassis. This feature allows all packets, including those with
errors, to be copied and sent to an analyzer or RMON probe. The analyzer or
RMON probe will see the data as i f it is directly connected to the LAN segment of
the source port.
Flow Control
Flow Control is a method of managing the flow of frames between two devices. It
ensures that a transmitting device does not overwhelm a receiving device with
data. This enables the receiving device to communicate with the transmitting
1-4
Introduction
device, and to have it pause its transmission while the receiving device processes
the frames already receive d. Flow contro l can be e nabled or disabl ed on a port-byport basis. Both devices must support the IEEE 802.3x standard for flow control to
work.
The 9E531-24 supports the following two types of flow control:
•frame based 802.3x
•back pressure
Frame based 802.3x flow control is supported on all Ethernet ports operating in
the full duplex mode.
Back pressure flow control is supported on all Ethernet ports operating in the
standard mode of operation.
802.1p Port Priority
The IEEE 802.1p standard is used to assign a default priority to the frames
received without priority information in their tag header, and to map prioritized
frames to the appropriate transmit queues.
The default priority-to-queue mappings are shown in Table 1-1. This
configuration can be changed by the admi nistrator.
Table 1-1. Priority Queuing Configuration
Priority IndicatorTransmit Queue
73
63
52
42
31
20
10
01
Switching Options
The 9E531-24 provides IEEE Standard-based 802.1 switching or SecureFast
Switching Virtual Network Services. In the 802.1 mode (the default mode of
operation), the switch functions as an 802.1D switch. When VLANs are
configured, it operates as an 802.1Q switch.
1-5
Introduction
Standards Compatibility
The 9E531-24 is fully compliant with the IEEE 802.3, 802.3x, 802.1Q, and 802.1p
standards. The 9E531-24 provides IEEE 802.1D Spanning Tree Algorithm (STA)
support to enhance the overall reliability of the network and protect against
“loop” conditions. The 9E531-24 supports a wide variety of industry standard
MIBs including RFC 1573 (MIB II), RFC 1271 (RMON), RFC 1493 (Bridge MIB),
RFC 1354 (FIB MIB), and RFC 1190 (Path MTU Discovery). A full suite of
Cabletron Systems Enterprise MIBs pr ovide a wide array of st atistical i nformation
to enhance troubleshooting.
For information about how to extract and compile individual MIBs, contact
Cabletron Systems.
GARP Switch Operation
Some or all ports on the switch may be activated to operate under the Generic
Attribute Registration Protocol (GARP) applications, GARP VLAN Registration
Protocol (GVRP) and/or GARP Multicast Registration Protocol (GMRP).
GARP is a protocol, or set of rules, that outlines a mechanism for propagating the
port state and/or user information throughout a bridged LAN to keep track of
users and VLANs on the network fabric. MAC bridges and end users alike can
take part in the registration and d e-r egistration of GARP attributes such as VLAN
and multicast group membership.
LANVIEW Diagnostic LEDs
LANVIEW diagnostic LEDs serve as an important troubleshooting aid by
providing an easy way to observe the status of individual ports and overall
network operations.
Year 2000 Compliance
The 9E531-24 module and the SmartSwitch 9000 chassis have an internal clock
that can maintain the time and date beyond the year 1999.
1-6
Related Manuals
The Cabletron Systems manuals listed below should be used to supplement the
procedures and technical data contained in this manual.
SmartSwitch 9000 Installation Guide
SmartSwitch 9000 9C300-1 Environmental Module User’s Guide
SmartSwitch 9000 9C214-1 AC Power Supply User’s Guide
SmartSwitch 9000 9X5XX Series Local Management User’s Guide
Cabling Guide
Ethernet Technology Guide
Network Troubleshooting Guide
WebView User’s Guide
SmartTrunk User’s Guide
Introduction
1-7
Introduction
Getting Help
For additional support related to this device or document, contact Cabletron
Systems using one of the following methods:
World Wide Webhttp://www.cabletron.com/
Phone(603) 332-9400
Internet mailsupport@cabletron.com
FTPftp://ftp.cabletron.com/
Login
Password
To send comments or suggestions concerning this document, contact the
Cabletron Systems Technical Writing Department via the following
email address: TechWriting@cabletron.com
Make sure to include the document Part Number in the email message.
Before calling Cabletron Systems, have the following information ready:
•Your Cabletron Systems service contract number
anonymous
your email address
•A description of the failure
•A description of any action(s) already taken to resolve the problem (e.g.,
changing mode switches, rebooting the unit, etc.)
•The serial and revision numbers of all involved Cablet ron Systems pr oducts in
the network
•A description of your network environment (layout, cable type, etc.)
•Network load and frame size at the time of trouble (if known)
•The device history (i.e., have you r eturned the device befor e, is this a r ecurring
problem, etc.)
•Any previous Return Material Authorization (RMA) numbers
1-8
Chapter 2
Installing the SmartSwitch 9000
Module
Only qualified personnel should perform installation procedures.
Unpacking the Module
1. Carefully remove the module from the shipping box. (Save the box and
packing materials in the event the module must be reshipped.)
2. Remove the module from the plastic bag. Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
3. Carefully examine the module, checking for damage. If any damage exists,
DO NOT install the module. Contact Cabletron Systems immediately.
User Accessible Components
Figure 2-1 shows the various components that are accessible to the user. These
consist of an eight-position DIP switch, replaceable PROMs and soc kets for RAM.
These components will be used for future upgrades. Instr uctions for installi ng the
components will be supplied with the upgrade kit.
2-1
Installing the SmartSwitch 9000 Module
SMB-1
PROM
i960
Processor
32 MB
DRAM
Flash
SIMM
Socket
1
2
3
4
5
6
7
8
DIP Switch
Figure 2-1. User-Accessible Components
Boot
PROM
2-2
Installing the SmartSwitch 9000 Module
An eight-position DIP switch is located on the module card as shown in
Figure 2-1. The function of the switches are listed in Table 2-1.
See the Cautions at the end of this table.
Table 2-1. Function of DIP Switch
SwitchFunctionDescription
When toggled, this switch clears user-entered
8
7
Clear
Password
Clear
NVRAM
passwords stored in NVRAM, and restores the
1
default passwords. Once reset you can use the
defaults or enter new passwords.
The module uses NVRAM to store userentered parameters such as IP addresses,
device name, etc. To reset these parameters to
the factory defaults, toggle this switch. Once
2
reset, you can use the defaults or enter new
parameters, which are stored in NVRAM
when the module is powered down, and
remain there until the switch is toggled again.
!
CAUTION
Toggling this switch after pul ling the board
out of the SmartSwitch 9000, clears download
information from NVRAM and forces image
6
5ReservedFor Factory Use Only
4ReservedFor Factory Use Only
3ReservedFor Factory Use Only
2ReservedFor Factory Use Only
1ReservedFor Factory Use Only
Force BootP
Download
files to be downloaded from the station
connected to the EPIM on the Environmental
Module configured to act as that modules’
ootP server. (See section titled Using DIP
B
Switch 6 on page 2-4.)
1. Caution: Do not toggle Switch 8 unless you intend to reset the user-
configured passwords to their factory default settings.
2. Caution: Do not t oggle Switch 7 unless you intend to reset the user
parameters to the factory default settings.
2-3
Installing the SmartSwitch 9000 Module
Using DIP Switch 6
The purpose of DIP switch 6 is to force a Flash download from a BootP server
through the EM-EPIM. The first step in this process is to configure the BootP
server. Configurations of BootP servers can differ from platform to platform and
from one operating system to another. Read the user’s manual on BootP and
TFTP serving for the correct files to edit and the correct files to execute for the
server. After configuration of the BootP server the module can then have the
switch state changed on dip switch 6 to initiate BootP and TFTP requests.
When the state of dip switch 6 is changed, the module begins requesting a BootP
server in an attempt to receive a Flash ima ge download. The modules boot PROM
initiates a BootP sequence. During this sequence, the module requests an IP
address and a filename from the BootP server. The module then requests a TFTP
of the file and receives the download of the image. The module will not function
until the Flash image is downloaded from the BootP and TFTP server.
If a BootP and TFTP are not intended at this time, this process may be stopped by
resetting the module. Resetting is done by pushing the reset button on the
module, power cycling the chassis, or removing the module from the chassis and
re-inserting. (See section titled
module again looks for a BootP server, but will time-out after about f our min utes.
After the time-out, the module boots from Flash memory. The next time the
power is cycled, the module will boot from Flash memory and not request the
BootP server.
The Reset Switch on page 2-6.) After resetting, the
Installing the Module into the SmartSwitch 9000
Chassis
To install the SmartSwitch 9000 module, follow the steps below:
NOTE
1. Remove the blank panel covering the two slots in which the module is being
2. Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000
2-4
The INB Terminator Modules must be installed on the rear of the fourteen slot
chassis before powering up this module. The INB Terminator Modules are not
required on the six slot chassis. Refer to the INB Terminator Modules Installation Guide for information and installation procedure.
installed. All other slots must be covered, if other modules are not being
installed, to ensure proper airflow and cooling.
chassis to your wrist. Plug the other end into the ESD Wrist Strap Grounding
receptacle in the lower right corner of the SmartSwitch 9000 chassis shown in
Figure 2-2.
Installing the SmartSwitch 9000 Module
3. Grasp the module and slide it into the slots. Make sure that the module’s
circuit card is bet ween the card guides, as shown in Figure 2-2. Check both the
upper and lower tracks of the car d. Take care that the module slides in straight
and engages the backplane connectors properly.
4. Lock down the top and bottom plastic tabs, as shown in Figure 2-2.
7
FLNK
8
FLNK
FLNK
10
RX
FLNK
INS
TX
11
RX
FLNK
INS
TX
12
RX
Metal Back- Panel
Circuit Card
Card Guides
Warning:
Ensure that the circuit card is between the card guides.
Lock down the top and bottom plastic tabs
at the same time, applying even pressure
Figure 2-2. Installing the 9E531-24 Module
Jack for ESD
wrist strap
.
2-5
Installing the SmartSwitch 9000 Module
The Reset Switch
The Reset switch is located under the top plastic tab as shown in Figure 2-3.
Use the reset switch to reset the module’ s processor, shutdown (power down) the
module, and/or restart the module.
•To reset the module’s i960 processor, press the reset switch twice within three
seconds.
•To shut down the module, press and hold the reset switch for three or more
seconds.
•To restart the module, press the reset switch momentarily.
SNMP management may be used to disable this switch to enhance module
security.
Reset Switch
Figure 2-3. The Reset Switch
Cabling Requirements
10BASE-FL Network
The 9E531-24 supports 10BASE-FL Ethernet specifications. When connecting a
10BASE-FL segment to any of the front panel ports, ensure that the network meets
the optical performance requirements for the 10BASE-FL 802.3 standard.
The 9E531-24 supports multimode fiber cables at the 850nm wavelength, at
lengths up to 2 km.
SMB
CPU
2-6
Technical Overview
SmartSwitch Architecture
The SmartSwitch Architecture of the 9E531-24 module, as shown in Figure 3-1, is
configurable for one of two modes of operation: traditional IEEE 802.1 switching,
or SecureFast switching. The module supports only one of these modes of
operation at any one time.
When operating in traditional IEEE 802.1 switch mode, the 9E531-24 makes
filtering/forwarding decisions based on Destination Addr ess (DA), with standard
IEEE 802.1D learning. 802.1Q VLANs are also supported.
Spanning tree operation for the 9E531-24 is config urable to adher e to IEEE 802.1D ,
DEC, or none. The default Spanning Tree Algorithm is 802.1D.
Chapter 3
When operating in SecureFast switch mode, al l filtering/forwar ding decis ions are
made on a DA-SA pair and its in and out port on a connection-orientated basis.
SecureFast switching mode provides value-added network services including
dynamic VLANs, Topology, Connectivity, IP Multicast, Control, Security,
Application, Address Management, Dynamic Mapping, and Directory services.
For example, Topology Services includes configurable options ranging from
simple spanning tree implementations to fully-meshed active topologies. Other
services and features supported in SecureFast switching mode are described in
detail in the Cabletr on W hite Paper, IP Host Communication in Bridged, Routed and SecureFast Networks.
3-1
Technical Overview
Figure 3-1. Block Diagram
System Management Buses
There are two management channels within the SmartSwitch 9000 system: the
SMB-1 and the SMB-10. These buses provide out-of-band management and
inter-module management communication.
3-2
SMB-1 Bus
The SMB-1 is a 1 Mbps management bus located within the SmartSwitch 9000.
This bus is utilized by all diagnostic controllers in the system including
connectivity modules, power supply modules and the environmental module.
The SMB-1 transports inter-chassis information between system components,
such as power and environmental information, as well as diagnostic messages.
Periodic loop-back tests are performed by all modules that share this bus to
ensure the validity of SMB-1. In the event a failure is detected on SMB-1, the
SMB-10 may be used as an alternate communication channel.
SMB-10 Bus
The SMB-10 is a 10 Mbps management bus located within the SmartSwitch 9000,
which is also used for inter-chassis communication of modules as well as serving
as an out-of-band management ch annel i nto the SmartSwitc h 9000 . The SMB-10 is
externalized from the chassis via an optional Ethernet Port Interface Module
(EPIM) located on the front of the Environ mental Module. Through an EPIM
connection, full SNMP management of the SmartSwitch 9000 is available out-ofband from user data. Modules which share the SMB-10 bus periodically send out
loop-back packets to ensure the validit y of SMB-10. In t he event a fault is detected
on the SMB-10, the SMB-1 can be used as an alternate communication chan nel by
the modules.
Technical Overview
System Diagnostic Controller
This diagnostic controller is composed of a Z-80 microprocessor and its
supporting logic. The diagnostic controller is designed to control the power-up
sequencing of modules, monitor the 9E531-24 input and output power
parameters, keep watch over the main host processor, as well as monitor the
temperature and control the SMB LANVIEW diagnostic LED. Although the
diagnostic controller and the main host processor can operate independent of
each other if needed, they exchange information about each other’s status and
overall module condition. The information gathered by the diagnostic controller
is available to the network manager via local/remote management and the LCD
located on the Environmental Module. Th e 9E531- 24 has been designed so that in
the event of a diagnostic controller fault, the 9E531-24 will continue to function.
DC/DC Converter
The DC/DC converter converts the 48 VDC on the system power bus to the
necessary operating voltages for its host network se rvices module . The di agnostic
controller monitors and controls the operation of the DC/DC converter.
3-3
Technical Overview
INB Interface
Each module attaches to both INB A and INB B and has two INB ASICs. The INB
ASICs use 64-byte Ethernet frames for transmission onto the INBs at 66 MHz.
The 9X5XX modules are fully compatible with the the first generation 9X4XX
modules. The first generation modules communicate only on INB B using a
56-byte canonical frame format, at 40 MHz. If the newer module detects a first
generation module on the backplane, it automatically changes from the fast
66 MHz Ethernet frames, to the first generation compatible 40 MHz canonical
frame on INB B only. INB A is used only by the 9X5XX modules and remains at
the higher speed.
i960 Core
The i960 core provides modules host services, the SNMP protocol stacks, to
support industry standard MIBs, as well as Cabletron enterprise extension MIBs
for each media type. Management services, such as telnet , WebV ie w and network
address to MAC address mapping, are also provided by the i960 core.
3-4
LANVIEW LEDs
The front panel LANVIEW LEDs indicate the status of the module and may be
used as an aid in troubleshooting. Figure 4-1 shows the LANVIEW LEDs of the
9E531-24 module.
Chapter 4
ETHERNET
9E531-24
System Status
INB Receive
INB Transmit
24
23
22
21
20
19
18
17
Figure 4-1. The 9E531-24 LANVIEW LEDs
Ethernet
Receive
Ethernet
Transmit
4-1
LANVIEW LEDs
The functions of the two System Status LEDs, System Management Bus (SMB)
and the CPU, are listed in Table 4-1.
Table 4-1. System Status (SMB and CPU) LEDs
LED ColorStateDescription
GreenFunctionalFully operational
YellowTestingPower-up testing
Yellow (Flashing)CrippledNot fully operational (e.g., one bad port)
Yellow/GreenBootingBlinks yellow and green while booting
RedResetNormal power-up reset
Red (Flashing)FailedFatal error has occurred
OffPower offModule powered off
The functions of the INB transmit LED are listed in Table 4-2.
Table 4-2. INB Transmit LED
LED ColorState
Green (Flashing)Data activity
Ye llow (Flashing)Port in standby state
Red (Flashing)Collision
RedFault
OffNo activity, Port disabled
The functions of the INB receive LED are listed in Table 4-3.
Table 4-3. INB Receive LED
LED ColorState
Green (Flashing)Link, Port disabled
4-2
GreenLink, Port enabled, No activity
Yellow (Flashing)Link, Port enabled, Activity
RedFault
OffNo Link
LANVIEW LE Ds
The functions of the Ethernet Transmit and Ethernet Receive LEDs are listed in
Table 4-4 and Table 4-5.
Table 4-4. Ethernet Transmit LEDs
ColorState
Green (Flashing)Activity (Flashing rate indicates rate of activity)
Ye llow (Flashing)Port in standby state
RedPort disabled
Red (Flashing)Collision
OffNo activity
Table 4-5. Ethernet Receive LEDs
LED ColorState
GreenLink, No activity
Yellow (Flashing)Link, Activity (Flashing rate indicates rate of activity)
RedPort disabled no link
Red (Flashing)Port disabled with link
OffNo link, No activity
4-3
LANVIEW LEDs
4-4
Specifications
Technical Specifications
CPUs
PowerPC
Intel i960 RISC based microprocessor
Memory
8 MB Flash Memory (expandable to 16 MB)
32 MB DRAM (local)
4 MB Memory (Shared)