Important Safety Instructions
are included in this manual.
46577
MADE IN CHINA
REV 46577-20140214
MODEL NUMBER
Champion Power Equipment
Santa Fe Springs CA 90670
www.championpowerequipment.com
Sidney, NE 69160
1-800-237-4444
www.cabelas.com
12039 Smith Ave.
USA / 1-877-338-0999
Cabela’s
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your
product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this
range before operation. In any event, the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and other vents.
Have questions or need assistance?
Do not return this product to the store!
WE ARE HERE TO HELP!
Visit our website:
www.championpowerequipment.com
for more info:
• Product Info & Updates
• Frequently Asked Questions
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
• Tech Bulletins
• Product Registration
WARNING:
The Engine Exhaust from this product contains chemicals known to the State of California
to cause cancer, birth defects or other reproductive harm.
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
Congratulations on your purchase of a Cabela’s
Outdoorsmen 4000 series generator, powered by
Champion Power Equipment. CPE designs and builds
generators to strict specifications. With proper use and
maintenance, this generator will bring years of satisfying
service.
Portable Power Generator
This unit is a gasoline engine driven, alternating current
(AC) generator. It is designed to supply electrical power
for lighting, appliances, tools and similar equipment.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this
information available when ordering parts and when making technical or warranty inquiries.
Accessories
Champion Power Equipment manufactures accessories
designed to help you get the most from your purchase.
To find out more about accessories, please visit either
web site:
www.championpowerequipment.com
www.cabelas.com
This Booklet
Every effort has been made to ensure the accuracy and
completeness of the information in this manual. We reserve
the right to change, alter and/or improve the product and
this document at any time without prior notice.
Champion Power Equipment Support
1-877-338-0999
Model Number
46577
Serial Number
Date of Purchase
Purchase Location
For O il Typ e see ‘Add Engine Oil‘ section. For Fuel Typ e see ‘Add Fuel‘ section.
1REV 46577-20140214
46577 ENGLISH
MANUAL CONVENTIONS
This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol
is used with a key word to alert you to potential hazards in operating and owning power equipment.
Follow all safety messages to avoid or reduce the risk of serious injury or death.
DANGER
DANGER indicates an imminently hazardous
situation which, if not avoided, will result in death
or serious injury.
WARNING
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in minor
or moderate injury.
CAUTION
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
NOTE
If you have questions regarding your generator, we can
help. Please call our help line at 1-877-338-0999.
REV 46577-20140214 2
SAFETY RULES
ENGLISH46577
WARNING
Read this manual thoroughly before operating your
generator. Failure to follow instructions could result
in serious injury or death.
WARNING
The engine exhaust from this product contains
chemicals known to the state of California to cause
cancer, birth defects, or other reproductive harm.
DANGER
Generator exhaust contains carbon monoxide, a
colorless, odorless, poison gas. Breathing carbon
monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh
air immediately.
Operate generator outdoors only in a well ventilated
area.
DO NOT operate the generator inside any building,
including garages, basements, crawlspaces and
sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined
area through windows, doors, vents or other
openings.
DANGER CARBON MONOXIDE: using a generator
indoors CAN KILL YOU IN MINUTES.
DANGER
Rotating parts can entangle hands, feet, hair,
clothing and/or accessories.
Traumatic amputation or severe laceration can result.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged
or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp
areas and areas containing conductive material such
as metal decking.
Use approved transfer equipment to isolate generator
from your electric utility and notify your utility
company before connecting your generator to your
power system.
WARNING
Sparks can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it
cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can
occur on contact.
Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all
sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from
combustible materials.
WARNING
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling
drawstrings or items that could become caught.
3REV 46577-20140214
Medical and Life Support Uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support
devices or life support appliances.
NEVER use this product to power medical devices
or medical appliances.
Inform your electricity provider immediately if you
or anyone in your household depends on electrical
equipment to live.
Inform your electrical provider immediately if a
loss of power would cause you or anyone in your
household to experience a medical emergency.
46577 ENGLISH
SAFETY RULES
DANGER
Fuel and fuel vapors are highly flammable and
extremely explosive.
Fire or explosion can cause severe burns or death.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
When adding or removing fuel:
Turn the generator off and let it cool for at least two
minutes before removing the fuel cap. Loosen the
cap slowly to relieve pressure in the tank.
Only fill or drain fuel outdoors in a well-ventilated area.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT overfill the fuel tank.
Always keep fuel away from sparks, open flames,
pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gas cap, air filter, spark plug,
fuel lines and exhaust system are properly in place.
Allow spilled fuel to evaporate fully before
attempting to start the engine.
Make certain that the generator is resting firmly on
level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off
position and the fuel tank is empty.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights,
heat and other sources of ignition.
WARNING
Operation of this equipment may create sparks that
can start fires around dry vegetation.
A spark arrestor may be required. The operator
should contact local fire agencies for laws or
regulations relating to fire prevention requirements.
WARNING
Rapid retraction of the starter cord will pull hand and
arm towards the engine faster than you can let go.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the starter cord slowly
until resistance is felt and then pull rapidly to avoid
kickback.
DO NOT start or stop the engine with electrical
devices plugged in.
CAUTION
Exceeding the generator’s running capacity can
damage the generator and/or electrical devices
connected to it.
DO NOT overload the generator.
Start the generator and allow the engine to stabilize
before connecting electrical loads.
Connect electrical equipment in the off position,
and then turn them on for operation.
Turn electrical equipment off and disconnect before
stopping the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Improper treatment or use of the generator can
damage it, shorten its life and void your warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture,
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and
disconnect them from the generator.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
REV 46577-20140214 4
ENGLISH 46577
CONTROLS AND FEATURES
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the
controls and features. Save this manual for future reference.
(3) Fuel Valve – Used to turn fuel supply on and off to
engine.
(4) Air Filter – Protects the engine by filtering dust
and debris from the intake air.
(5) Recoil Starter – Used to manually start the engine.
8
7
6
(6) Never Flat Tires
(7) Oil Filler Cap – Check and fill engine oil level.
(8) Power Panel – See “Power Panel” section.
(9) Power Cord Clips – Used to hold power cord when
not in use.
(10) Handle
5REV 46577-20140214
46577 ENGLISH
Power Panel
CONTROLS AND FEATURES
61453782
(1) Engine Switch – Used to start or stop the
generator.
(2) Circuit Breakers – Protects the generator against
electrical overloads.
(3) Voltmeter – Used to display generator output
voltage.
(4) 120/240 Volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L14-30R) – May be used to supply
electrical power for the operation of 120/240 Volt
AC, single phase 60 Hz electrical loads.
(5) Voltage Switch – Choose between 120 Volts or
240 Volts opportation
(6) 120 Volt AC, 30 Amp Receptacle
(NEMA TT-30R) – May be used to supply electrical
power for the operation of 120 Volt AC, single
phase 60 Hz electrical loads.
(7) 120 Volt AC, 20 Amp Receptacle(NEMA 5-20R)
– May be used to supply electrical power for the
operation of 120 Volt AC, single phase 60 Hz
electrical loads.
(8) Ground Terminal – Consult an electrician for local
grounding regulations.
REV 46577-20140214 6
CONTROLS AND FEATURES
Parts Included
Your 46577 gasoline powered generator ships with the
following parts:
Wheel Kit
– 8 in. Wheel ...........................2
– Flange Bolt (M10x105 for Wheel) ............2
– Bushing ..............................2
– Flat Washer Ø10 ........................2
– Lock Nut (M10) ........................2
– Support Leg (w/vibration mounts) ............1
– Flange Bolt (M8x16 for Support Leg) ..........2
– Handle ..............................1
– Flange Bolt (M8x45 for Handle) .............2
– Flange Nut (M8) ........................4
Other
– 19 in. Generator Cable ....................1
– Oil Funnel ............................1
– Spark Plug Socket.......................1
ENGLISH46577
7REV 46577-20140214
46577 ENGLISH
ASSEMBLY
Your generator requires some assembly. This unit ships
from our factory without oil. It must be properly serviced
with fuel and oil before operation.
If you have any questions regarding the assembly of your
generator, call our help line at 1-877-338-0999. Please
have your serial number and model number available.
Remove the Generator from the Shipping Carton
1. Set the shipping carton on a solid, flat surface.
2. Remove everything from the carton except the
generator.
3. Carefully cut each corner of the box from top to
bottom. Fold each side flat on the ground to provide a
surface area to install the wheel kit and support leg.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
You will need the following tools to install the wheels:
• 17 mm wrench OR adjustable wrench (not included)
• Socket wrench with a 16 mm socket (not included)
• Pliers (not included)
1. Before adding fuel and oil, tip the generator on it’s side.
2. Slide the M10x105 wheel bolt through the washer,
sleeve and wheel.
3. Slide the bolt through the mount point on the frame.
4. Fasten securely with the M10 nut.
5. Repeat steps 2-4 to attach the second wheel.
Install the Support Leg
1. Attach the support leg to the generator frame with
cap screws (M8x16) and nuts (M8).
2. Tip the generator slowly so that it rests on the
wheels and support leg.
Install the Handle
1. Place the handle over the mounting channel on the
frame.
2. Secure the handle to the frame using the two handle
bolts (M8x45).
3. Place a lock nut (M8) on the end of each bolt and
fasten securely. DO NOT over tighten the lock nuts.
REV 46577-20140214 8
ASSEMBLY
ENGLISH46577
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine before
it has been properly filled with the recommended
type and amount of oil. Damage to the generator as
a result of failure to follow these instructions will
void your warranty.
NOTE
The recommended oil type is 10W-30 automotive
oil.
1. Place the generator on a flat, level surface.
Add Engine Oil Cont’d.
CAUTION
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
NOTE
Check oil often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
NOTE
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for
the life of the bearing.
2. Remove oil fill cap/dipstick to add oil.
3. Add up to 0.6 qt. (0.6 L) of oil and replace oil fill
cap/dipstick. DO NOT OVERFILL.
4. Check engine oil level daily and add as needed.
9REV 46577-20140214
46577 ENGLISH
ASSEMBLY
Add Fuel
1. Use clean, fresh, regular unleaded fuel with a minimum
octane rating of 85 and an ethanol content up to 10%
by volume.
2. DO NOT mix oil with fuel.
3. Clean the area around the fuel cap.
4. Remove the fuel cap.
5. Slowly add fuel to the tank. DO NOT OVERFILL. Fuel
can expand after filling. A minimum of ¼ in. (6.4 mm)
of space left in the tank is required for fuel expansion,
more than ¼ in. (6.4 mm) is recommended. Fuel can
be forced out of the tank as a result of expansion if it is
overfilled, and can affect the stable running condition of
the product. When filling the tank, it is recommended
to leave enough space for the fuel to expand.
Add Fuel Cont’d.
NOTE
Our engines work well with 10% or less ethanol
blend fuels. When using blended fuels there are
some issues worth noting:
– Ethanol-gasoline blends can absorb more water
than gasoline alone.
– These blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and
carbureto r.
– With gravity-fed fuel supplies, this compromised
fuel can be drawn into the carburetor and cause
damage to the engine and/or potential hazards.
– There are only a few suppliers of fuel stabilizer
that are formulated to work with ethanol blend
fuels.
– Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufacture’s warranty.
It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
when the equipment is not in use for more than 30
days.
6. Screw on the fuel cap and wipe away any spilled fuel.
CAUTION
Use regular unleaded gasoline with a minimum
octane rating of 85.
Do not mix oil and gasoline.
Fill tank to approximately ¼ in. (6.4 mm) below the
top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT fill fuel tank indoors.
DO NOT fill fuel tank when the engine is running or hot.
DO NOT overfill the fuel tank.
DO NOT light cigarettes or smoke when filling the
fuel tank.
WARNING
Grounding
Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result
in electric shock.
A ground terminal connected to the frame of the generator
has been provided on the power panel. For remote
grounding, connect of a length of heavy gauge
(12 AWG minimum) copper wire between the generator
ground terminal and a copper rod driven into the ground.
We strongly recommend that you consult with a qualified
electrician to ensure compliance with local electrical codes.
Pouring fuel too fast through the fuel screen may
result in blow back of fuel at the operator while filling.
REV 46577-20140214 10
OPERATION
ENGLISH46577
Generator Location
NEVER operate the generator inside any building,
including garages, basements, crawlspaces and sheds,
enclosure or compartment, including the generator
compartment of a recreational vehicle. Please consult
your local authority. In some areas, generators must
be registered with the local utility. Generators used at
construction sites may be subject to additional rules and
regulations. Generators should be on a flat, level surface
at all times. (Even while not in operation) Generators
must have at least 5 ft. (1.5 m) of clearance from all
combustible material. In addition to clearance from
all combustible material, generators must also have
at least 3 ft. (91.4 cm) of clearance on all sides to
allow for adequate cooling, maintenance and servicing.
Generators should never be started or operated in the
back of a SUV, camper, trailer, in the bed of a truck
(regular, flat or otherwise), under staircases/stairwells,
next to walls or buildings, or in any other location that
will not allow for adequate cooling of the generator
and/or the muffler. DO NOT contain generators during
operation. Allow generators to properly cool before
transport or storage.
Place the generator in a well-ventilated area. DO NOT
place the generator near vents or intakes where exhaust
fumes could be drawn into occupied or confined
spaces. Carefully consider wind and air currents when
positioning generator.
Failure to follow proper safety precautions may void
manufacturer’s warranty.
Grounding
The generator system ground connects the frame to the
ground terminals on the power panel.
– The generator (stator winding) is isolated from the
frame and from the AC receptacle ground pin.
– Electrical devices that require a grounded receptacle
pin connection will not function if the receptacle
ground pin is not functional.
Surge Protection
CAUTION
Voltage fluctuation may impair the proper
functioning of sensitive electronic equipment.
Electronic devices, including computers and many
programmable appliances use components that are
designed to operate within a narrow voltage range and
may be affected by momentary voltage fluctuations.
While there is no way to prevent voltage fluctuations, you
can take steps to protect sensitive electronic equipment.
Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually
all short-duration voltage fluctuations.
WARNING
Do not operate or store the generator in rain, snow,
or wet weather.
Using a generator or electrical appliance in wet
conditions, such as rain or snow, or near a pool or
sprinkler system, or when your hands are wet, could
result in electrocution.
WARNING
During operation the muffler and exhaust fumes
produced will become hot. If adequate cooling and
breathing space are not supplied, or if the generator
is blocked or contained, temperatures can become
extremely heated and may lead to fire.
11REV 46577-20140214
46577 ENGLISH
OPERATION
Recoil Start
1. Make certain the generator is on a flat, level surface.
2. Turn off all electrical loads connected to the
generator. Never start or stop the generator with
electrical devices plugged in and turned on.
3. Turn the Fuel Valve to the “ON” position.
4. Press the Engine Switch to “ON”.
5. Move the choke lever to the “CHOKE” position.
6. Pull the starter cord slowly until resistance is felt and
then pull rapidly.
7. Do not over-choke. As as soon as engine starts, move
the choke lever to the “RUN” position.
NOTE
Keep choke lever in “Choke” position for only 1
pull of the recoil starter. After first pull, move choke
lever to the “Run” position for up to the next 3
pulls of the recoil starter. Too much choke leads to
spark plug fouling/engine flooding due to the lack of
incoming air. This will cause the engine not to start.
NOTE
If the engine starts but does not continue to run
make certain that the generator is on a flat, level
surface. The engine is equipped with a low oil
sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
Connecting Electrical Loads
1. Let the engine stabilize and warm up for a few
minutes after starting
2. Plug in and turn on the desired 120 or 240 Volt AC
single phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT connect 50 Hz loads to the generator.
– DO NOT overload the generator.
Connecting Electrical Loads Cont’d.
NOTE
Connecting a generator to your electric utility
company’s power lines or to another power source
may be against the law. In addition this action,
if done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
notify your electric utility company immediately
and remember to plug your appliances directly
into the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your
generator’s electricity does not feed back into the
electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility company
or a qualified electrician. Connections must isolate
generator power from utility power and must comply
with all applicable laws and codes.
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start
or stop the generator with electrical devices plugged
in or turned on.
2. Let the generator run at no-load for several minutes
to stabilize internal temperatures of the engine and
generator.
3. Turn the Fuel Valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped
the engine. This usually takes a few minutes.
5. Press the ignition switch to the “OFF” position.
Important: Always ensure that the Fuel Valve and the
Engine Switch are in the “OFF” position when the engine
is not in use.
NOTE
If the engine will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine
and fuel storage.
REV 46577-20140214 12
OPERATION
ENGLISH46577
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and
starting watts necessary for your purposes.
1. Select the electrical devices you plan on running at
the same time.
2. Total the running watts of these items. This is
the amount of power you need to keep your items
running.
3. Identify the highest starting wattage of all devices
identified in step 1. Add this number to the number
calculated in step 2. Surge wattage is the extra
burst of power needed to start some electric driven
equipment. Following the steps listed under “Power
Management” will guarantee that only one device will
be starting at a time.
Power Management
Use the following formula to convert voltage and
amperage to watts:
Volts x Amps = Watts
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach
the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
NOTE
Never exceed the specified capacity when adding
loads to the generator.
Operation at High Altitude
The density of air at high altitude is lower than at sea
level. Engine power is reduced as the air mass and airfuel ratio decrease. Engine power and generator output
will be reduced approximately 3½% for every 1000
feet of elevation above sea level. This is a natural trend
and cannot be changed by adjusting the engine. At high
altitudes increased exhaust emissions can also result
due to the increased enrichment of the air fuel ratio.
Other high altitude issues can include hard starting,
increased fuel consumption and spark plug fouling.
To alleviate high altitude issues other than the natural
power loss, Champion Power Equipment can provide a
high altitude carburetor main jet. The alternative main
jet and installation instructions can be obtained by
contacting Customer Support. Installation instructions
are also available in the Technical Bulletin area of the
Champion Power Equipment internet site.
The part number and recommended minimum altitude
for the application of the high altitude carburetor main
jet is listed in the table below.
In order to select the correct high altitude main jet
it is necessary to identify the carburetor model. For
this purpose, a code is stamped on the side of the
carburetor. Select the correct main jet part number
corresponding to the carburetor code found on your
particular carburetor.
Carburetor
Code
P19-2-R
P19-2-Z
P19-2-H
Main JetPart NumberAltitude
Standard26. 131017.20. R
Altitude26.131017.20 .01.R
Standard26. 131017.20. Z
Altitude26.131017.20 .01.Z
Standard26. 131017.20. H
Altitude26.131017.20 .01.H
3500 Feet
(1067 Meters)
WARNING
13REV 46577-20140214
Operation using the alternative main jet at elevations
lower than the recommended minimum altitude can
damage the engine. For operation at lower elevations, the
standard main jet must be used. Operating the engine
with the wrong engine configuration at a given altitude
may increase its emissions and decrease fuel efficiency
and performance.
46577 ENGLISH
MAINTENANCE AND STORAGE
The owner/operator is responsible for all periodic
maintenance.
WARNING
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set governor will void
your warranty.
WARNING
Improper maintenance will void your warranty.
NOTE
Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
Oil Cont’d.
NOTE
Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.
Spark Plugs
1. Remove the spark plug cable from the spark plug.
2. Use a 13/16 in. or 21 mm socket to remove the plug.
3. Inspect the electrode on the plug. It must be clean and
not worn to produce the spark required for ignition.
4. Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
NOTE
For service or parts assistance, contact our help
line at 1-877-338-0999
Engine Maintenance
To prevent accidental starting, remove and ground spark
plug wire before performing any service.
Oil
Change oil when the engine is warm. Refer to the oil
specification to select the proper grade of oil for your
operating environment.
1. Remove the oil drain plug with a 12 mm socket and
extension.
2. Allow the oil to drain completely.
3. Replace the drain plug.
4. Remove oil fill cap/dipstick to add oil.
5. Add up to 0.6 qt. (0.6 L) of oil and replace oil fill
cap /dipstick. DO NOT OVERFILL.
6. Dispose of used oil at an approved waste
management facility.
0.7 - 0.8 mm
0.028 - 0.031 in.
5. Refer to the spark plug recommendation chart when
replacing the plug.
6. Carefully thread the plug into the engine.
7. Use the spark plug tool to firmly install the plug.
8. Attach the spark plug wire to the plug.
Air Filter
1. Remove the snap-on cover holding the air filter to
the assembly.
2. Remove the foam element.
3. Wash in liquid detergent and water. Squeeze
thoroughly dry in a clean cloth.
4. Saturate in clean engine oil.
5. Squeeze in a clean, absorbent cloth to remove all
excess oil.
6. Place the filter in the assembly.
7. Reattach the air filter cover and snap in place.
REV 46577-20140214 14
MAINTENANCE AND STORAGE
ENGLISH46577
Spark Arrester
1. Allow the engine to cool completely before servicing
the spark arrester.
2. Remove the two screws holding the cover plate which
retains the end of the spark arrester to the muffler.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark
arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and attach
with the two screws.
CAUTION
Failure to clean the spark arrester will result in degraded
engine performance.
NOTE
Federal and local laws and administrative
requirements indicate when and where spark
arresters are required. When ordered, spark
arresters are required for operation of this generator
in National Forest lands. In California, this
generator must not be used on any forest- covered
land, brush-covered land, or grass- covered land
unless the engine is equipped with a spark arrester.
Cleaning
CAUTION
Adjustments
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. CPE
recommends that you contact our service line at
1-877-338-0999 for all other service and/or adjustment
needs.
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule.
Service your generator more frequently when operating
in adverse conditions.
Contact our helpline at 1-877-338-0999 to locate the
nearest Champion Power Equipment certified service
dealer for your generator or engine maintenance needs.
Every 8 hours or daily
Check oil level
Clean around air intake and muffler
First 5 Hours
Change oil
Every 50 hours or every season
Clean air filter
Change oil if operating under heavy load or in hot
environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance*
Clean spark arrester
Clean fuel tank and filter*
Every 250 hours
Clean combustion chamber*
Every 3 years
Replace fuel line
*To be performed by knowledgeable, experienced owners or
Champion Power Equipment certified dealers.
DO NOT spray engine with water.
Water can contaminate the fuel system.
Use a damp cloth to clean exterior surfaces of the engine.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the engine.
15REV 46577-20140214
46577 ENGLISH
MAINTENANCE AND STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored
properly. Only operate the unit on a flat, level surface in
a clean, dry operating environment. DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors.
CAUTION
DO NOT use a garden hose to clean the generator.
Water can enter the generator through the cooling
slots and damage the generator windings.
Use a damp cloth to clean exterior surfaces of the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.
Storage
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
longer term storage, please follow these guidelines.
Generator Storage
1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the
generator.
3. Run the generator for a few minutes so the treated
fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has
stopped the engine. This usually takes a few minutes.
6. The generator needs to cool completely before
cleaning and storage.
7. Clean the generator according to the maintenance section.
8. Change the oil.
9. Remove the spark plug and pour about 1⁄2 ounce
(14.8 mL) of oil into the cylinder. Crank the engine
slowly to distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct
sunlight.
Generator Storage Cont’d.
NOTE
Our engines work well with 10% or less ethanol
blend fuels. When using blended fuels there are
some issues worth noting:
– Ethanol-gasoline blends can absorb more water
than gasoline alone.
– These blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and
carbureto r.
– With gravity-fed fuel supplies, this compromised
fuel can be drawn into the carburetor and cause
damage to the engine and/or potential hazards.
– There are only a few suppliers of fuel stabilizer
that are formulated to work with ethanol blend
fuels.
– Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufacture’s warranty.
It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
when the equipment is not in use for more than 30
days.
DANGER
Generator exhaust contains odorless and colorless
carbon monoxide gas.
To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:
– When storing the generator for short or extended
periods of time make sure that the Engine
Switch and the Fuel Valve are set in the OFF
position.
Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
Maintenance Valve Clearance
– Intake: 0.13 – 0.17 mm (0.005 – 0.007 in.)
– Exhaust: 0.18 – 0.22 mm (0.007 – 0.009 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.
An Important Message About Temperature
Your product is designed and rated for continuous
operation at ambient temperatures up to 40°C (104°F).
When your product is needed your product may be
operated at temperatures ranging from -15°C (5°F)
to 50°C (122°F) for short periods. If the product is
exposed to temperatures outside this range during
storage, it should be brought back within this range
before operation. In any event, the product must always
be operated outdoors, in a
well-ventilated area and away from doors, windows and
other vents.
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 0.6 qt. (0.6 L).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
17REV 46577-20140214
46577 ENGLISH
Wiring Diagram
SPECIFICATIONS
REV 46577-20140214 18
SPECIFICATIONS
Parts Diagram
ENGLISH46577
22
52
53
49
5051
48
47
46
45
13
57
44
56
55
43
54
42
41
40
39
38
37
34
32
35
33
36
27
31
30
29
28
16
25
26
27
3
2
1
23
24
22
14
13
12
11
10
9
8
7
6
5
4
93
95
102
19 2021
17
18
17
16
15
92
91
94
19REV 46577-20140214
58
59
60
56
61
62
63
64
65
66
27
717273
6768
69
70
56
101
100
99
22
98
97
96
74
75
76
81
77787980
8283
7387888990
86
85
84
46577 ENGLISH
Parts List
#Part NumberDescriptionQty
26.401.94Engine, Green1
1
122.190005.00Rubber, Fore-Cover, B1
2
122.190005.01Rubber, Fore-Cover, A
3
123 .191100.19
4
2.08.022Flange Bolt M8×242
5
1.96.08Washer Ø8
6
1.7244.08Spring Washer Ø8
7
123.191200.23
8
123 .191002.01Stator Cover
9
122.190002.00End Housing
10
2.08.065Flange Bolt M6×168
11
1.97.1.06Washer Ø6
12
1.93.06Spring Washer Ø6
13
122.190300.00Carbon Brush Assembly
14
122.190004.01Pinch, Carbon Brush
15
1.93.05Spring Washer Ø5
16
1.5783.0516Bolt M5 ×16
17
1.97.1.05Washer Ø5
18
122 .190200.03AVR (2KW CPE)
19
1.16674.0516Flange Bolt M5×16
20
122.190003.00.94Generator End Cover, Green
21
1.166 74. 0512 .2Flange Bolt M5×12
22
122.190400.00Terminal Block
23
122.190018.00Bracket I, Muffler
24
1.166 74. 0 820Flange Bolt M8×20
25
122.190018.01Bracket II, Muffler
26
1.5789.0612Flange Bolt M6×12
27
1.9074.4.0514
28
46 .101503.08Plate, Spark Arrester
29
46 .101300.08Spark Arrester Assembly
30
26.101000.00Muffler Assembly
31
23.102000.03.2Muffler Cover
32
1.6175. 08Nut M8
33
1.93.08Spring Washer Ø8
34
1.848.08Washer Ø8
35
26.100001.00Muffler Gasket
36
23.090006.21Holder, Air Cleaner
37
1.5789.06 08Flange Bolt M6×8
38
23.070011.04Pipe, Fuel (6.1 in.)
39
2.06.007Clamp (Ø8×b6)
40
122.070400.05Fuel Co ck
41
122.071000.05.94Fuel Tank, Green
42
122.070 015.01Mount Vibration, Fuel Tank
43
2.03.004Washer (Ø24ר6.5×1.5)
44
1.5789.0620.2Flange Bolt M6×20
45
23.070301.00Fuel Filter
46
24.070100.00Fuel Tank Cap
47
24.070014.05
48
24.070030.00Hole, Breather Tube
49
2.06.006Clamp ( Ø7ר1)
50
24.070800.00Reversal Valve
51
Rotor Assembly, Al,
120 mm, No DC
Stator Assembly, Al,
120 mm, No DC
Screw And Washer Assembly
M5 ×14
Pipe, Reversal Valve,
630 mm
#Part NumberDescriptionQty
1.819.0510Screw M5×10
52
122.072000.00Fuel Meter Assembly
53
152.200702.00Cover, Handle
1
1
1
1
1
1
1
1
4
4
8
1
1
3
3
2
1
2
1
7
1
1
3
1
7
2
1
1
1
1
2
2
2
1
1
1
1
2
1
1
4
4
4
1
1
1
1
1
1
54
122.200700.03.2Handle
55
1.6177.1.08Flange Lock Nut M8
56
1.5789.08 45Flange Bolt M8×45
57
6.2.263.318.2Frame
58
2.05.001Clamp (Ø8×6.5)
59
122.201200.05Motor Mount, II
60
122.201200.0 4Motor Mount, I
61
1.6182.10Lock Nut M10
62
122.201701.05.28 in. Wheel
63
122.20 0016.01Bushing (Ø16 × Ø10.5 ×58.5)
64
1.96.10Washer Ø10
65
1.57 82.10105Bol t M10 ×10 5
66
1.5789.0816Flange Bolt M8×16
67
152.200002.00.2Support Leg
68
152.201400.00Rubber, Support
69
1.5789.0825Flange Bolt M8×25
70
1.6177.1.06Flange Lock Nut M6
71
5.19 00.0 26Grounding Line 150 mm
72
1.862.06Lock Washer Ø6
73
2.08.068.2Flange Bolt M5×13
74
122.01.110 .2Control Panel
75
5.1000.004.3Ignition Switch
76
5.1400.003Voltage Meter
77
1.848.03.2Washer Ø3
78
1.859.03.2Spring Washer Ø3
79
1.6175. 03 .2Nut M3
80
5.1120 .0 0 9Receptacle L14-30R
81
1.9074.4.0414.1
82
1.6177.1.04 .1Flange Lock Nut M4, Black
83
5.1020.002
84
5.1120 .0 3 4Receptacle TT-30R
85
5.1120 .0 30Receptacle 5-20R
86
1.5783.0622.3Bolt M6×22, Green
87
1.6175. 06 .3Nut M6, Green
88
1.97.1.06.3Washer Ø6, Green
89
1.93.06.3Spring Washer Ø6, Green
90
122.210003.01Plug, Control Box
91
5.13 30 .0 01Sheath, Wire
92
122.210003.03Plug, End Cover
93
5.1810.0 01Over Voltage Protector
94
1.8 23 .0514Screw M5×14
95
5.1210.920
96
5.12 00.215
97
1.6177.1.05Flange Lock Nut M5
98
254.200015.00.2Clamp, Wand
99
122.210002.02Control Box
100
1.9074.1.0538.2
101
122.210003.00Grommet
102
Screw And Washer Assembly
M4 ×14, Bl ac k
120/240V Change-over
Switch
AC 20A Breaker, Push
Button, CSA
AC 15A Breaker, Push
Button, CSA
Screw And Washer Assembly
M5×38
2
1
1
1
14
2
1
2
2
2
2
2
2
2
2
2
1
2
2
1
1
2
4
1
1
1
4
4
4
1
6
6
1
1
1
1
2
2
2
1
1
1
1
1
1
2
4
2
1
3
1
REV 46577-20140214 20
SPECIFICATIONS
Engine Parts Diagram
96
ENGLISH 46577
95
94
93
90
88
87
86
85
84
51
14
91
11
81
83
82
80
79
78
77
19
28
16
97
92
1
75
74
76
33
34
31
56
55
73
72
71
70
69
39
36
12
59
57
58
68
67
66
63
62
61
60
64
25
47
46
65
44
43
42
41
40
12
38
48
53
52
51
50
49
101
100
99
18
19
89
45
54
24
23
22
21
20
37
35
98
32
30
29
27
26
25
15
2
13
12
10
9
8
7
6
5
4
3
17
21REV 46577-20140214
1
46577 ENGLISH
#Part NumberDescriptionQty
1.5789.06 08Flange Bolt M6×85
1
22.061100.00.2Recoil Starter Cover, Black1
2
21.061005.00Recoil Star ter Spring
3
2.10. 003Rope (Ø5×15 50 )
4
21.061001.01Recoil Starter Reel
5
45.060003.00Spring, Ratchet
6
45.060002.00Starter Ratchet (Iron)
7
45.060009.00Spring, Ratchet Guide
8
45.060007.00Ratchet Guide
9
45.060008.00Screw, Ratchet Guide
10
24.040004.00Guide Plate Push Rod
11
1.5789.0612Flange Bolt M6×12
12
24.080100.01.94Fan Cover, Green
13
24.0 9110 0.21Base, Air Cleaner
14
21.061300.00Recoil Handle
15
24.130004.20Gasket, Air Cleaner
16
22.061000.00Recoil Assembly
17
24.091000.21Air Cleaner Assembly
18
26.131000.20Carburetor
19
2.03.016
20
2.02.006Nu t ( M14×1.5)
21
21.060 001. 01Pulley, Starter
22
23.080001.00Cooling Fan
23
24.12010 0.06Flywheel
24
2.11.0 01Oil Seal (Ø25ר41.3×6)
25
2.03.020.1
26
21.110100 .0 0Governor Gear
27
23.13010 0. 20Choke Lever
28
21.110013.00Shaft, Governor Gear
29
21.110011.0 0Clip, Governor Gear
30
22.130003.00Gasket, Carburetor
31
21.110012.01Bushing, Governor Gear (Iron)
32
24.130002.00Gasket, Insulator
33
23.130001.00Insulator, Carburetor
34
23.080600.00Air Guide, Right Side
35
2.01.003Stud Bolt M6×90
36
26.030100.00Crankcase (200)
37
21.127000.02Oil Level Sensor
38
26.010100.0 0Cylinder Head (168-2)
39
23.050200.00Connecting Rod
40
25.0 50100.11
41
1.276.6205Bearing 6205
42
24.030008.00Gasket, Crankcase Cover
43
22.031000.00.1Oil Dipstick Assembly, Black
44
2.03.021.1Washer (Ø6.4× Ø13×1), Black
45
23.030007.01
46
1.5789.0832.0.8Flange Bolt M8 ×32
47
23.0910 02.21Seal, Air Cleaner
48
23.110006.00Governor Rod
49
21.110003.00Governor Arm
50
1. 6 17 7. 0 6Flange Nut M6
51
Washer, Drain Bolt
(Ø10 × Ø16×1.5)
Washer (Ø6.2ר15×0.5),
Black
Crankshaft (A 200Engine For
Equipment)
Cover, Crankcase (Engine For
Equipment)
#Part NumberDescriptionQty
21.110001.00Shaft, Governor Arm
52
22.123000.01
53
1
1
1
2
2
1
1
1
1
8
1
1
1
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1.5789.0625Flange Bolt M6×25
54
23.110005.01Spring, Throttle Return
55
23.110007.00Spring, Governor
56
2.08.040Bolt, Governor Arm (M6×21)
57
21.110008.00Pin, Shaft
58
23 .1110 00. 20
59
25.040013.00Lifter, Valve
60
2.04.001Dowel Pin (Ø9×14)
61
26.041000.00Camshaft (200 EPA)
62
2.14.012Woodruff Key (4×7.5×19)
63
2.08.037Drain Bolt (M10×1.25×25)
64
26.050005.00Piston
65
23.050003.00Pin, Piston
66
2.09.001Circlip (Ø18 × Ø1)
67
26.050303.00Ring, Oil
68
26.050302.00Ring, Second Piston
69
26.050301.00Ring, First Piston
70
26.030009.00Gasket, Cylinder Head (168-2)
71
2.04.003Dowel Pin (Ø10×14)
72
23.040002.00Valve, Intake
73
23.040006.00Valve, Exhaust
74
26.080400.00Air Guide, Lower (200G)
75
2.15.002(F6RTC)Spark Plug (F6RTC)
76
1.5789.08 55Flange Bolt M8×55
77
23.040017.00Oil Seal, Valve (Iron)
78
21.040003.00Spring, Valve
79
21.040007.00
80
1
21.040001.00
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
6
1
1
1
3
81
21.040008.00Rotator, Exhaust Valve
82
24.040202.00Shaft, Rocker Arm
83
22.040009.00Rocker Arm, Intake Valve
84
22.040012.00Screw, Valve Adjustment
85
21.040021.0 0Lock Nut (M6× 0.5)
86
1.97.1.06Washer Ø6
87
1.6177.1.06Flange Lock Nut M6
88
26.1 31 017. 2 0Standard Main Jet
89
26.131017.20.01Altitude Main Jet
24.040201.00Retainer, Rocker Arm
90
23.040010.00Bolt, Rocker Arm
91
23.040005.00Push Rod
92
21.020002.01Gasket, Cylinder Head Cover
93
24.021000.00Cylinder Head Cover (CPE)
94
23.020001.02Breather Tube
95
1.5789.0615Flange Bolt M6×15
96
2.01.010Stud Bolt M8 ×35
97
1.5789.0620Flange Bolt M6×20
98
24.091200.20Cover, Air Cleaner
99
23.091003.21Element, Air Cleaner
100
23.0910 01.21Separator, Air Cleaner
101
Ignition Coil (Silicon Rubber
EPA)
Control Assembly (Engine For
Equipment)
Retainer, Exhaust Valve Spring
(Up)
Retainer, Intake Valve Spring
(Up)
1
1
2
1
1
1
1
1
2
2
1
1
2
1
1
2
1
1
1
1
2
1
1
1
1
4
2
2
1
1
1
1
2
2
2
2
2
1
/
1
2
2
1
1
1
4
2
1
1
1
1
REV 46577-20140214 22
TROUBLESHOOTING
ProblemCauseSolution
Generator will not startNo fuelAdd fuel
Faulty spark plugReplace spark plug
Unit loaded during start upRemove load from unit
Generator will not start;
Generator starts but runs roughly
Generator shuts down during operationOut of fuelFill fuel tank
Generator cannot supply enough power or
overheating
No AC outputCable not properly connectedCheck all connections
Generator gallopsEngine governor defectiveContact the help line
Repeated circuit breaker trippingOverloadReview load and adjust. See “Power
Low oil levelFill crankcase to the proper level
Place generator on a flat, level surface
Choke in the wrong positionAdjust choke
Spark plug wire looseAttach wire to spark plug
Low oil levelFill crankcase to the proper level. Place
generator on a flat, level surface
Generator is overloadedReview load and adjust. See “Power
Management”
Insufficient ventilationCheck for air restriction. Move to a well
ventilated area
Connected device is defectiveReplace defective device
Champion Power Equipment (CPE) will register this
warranty upon receipt of your Warranty Registration Card
and a copy of your sales receipt from one of CPE’s retail
locations as proof of purchase.
Please submit your warranty registration and your proof
of purchase within ten (10) days of the date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the
mechanical and electrical components will be free of
defects in material and workmanship for a period of
one year (parts and labor) and two years (parts) from
the original date of purchase (90 days (parts and
labor) and 180 days (parts) for commercial & industrial
use). Transportation charges on product submitted
for repair or replacement under this warranty are the
sole responsibility of the purchaser. This warranty only
applies to the original purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will
troubleshoot any issue via phone or e-mail. If the
problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the
defective part or component at a CPE Service Center.
CPE will provide you with a case number for warranty
service. Please keep it for future reference. Repairs
or replacements without prior authorization, or at an
unauthorized repair facility, will not be covered by this
warranty.
Installation, Use and Maintenance Cont’d.
Normal maintenance such as spark plugs, air filters,
adjustments, fuel system cleaning and obstruction due
to buildup is not covered by this warranty.
Other Exclusions
This warranty excludes:
– Cosmetic defects such as paint, decals, etc.
– Wear items such as filter elements, o-rings, etc.
– Accessory parts such as starting batteries, and
storage covers.
– Failures due to acts of God and other force majeure
events beyond the manufacturer’s control.
– Problems caused by parts that are not original
Champion Power Equipment parts.
This warranty does not apply to generators used for
prime power in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to
cover any loss of time, use of this product, freight, or
any incidental or consequential claim by anyone from
using this generator. THIS WARRANTY IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the
warranty of the original unit. The length of the warranty
governing the exchanged unit will remain calculated by
reference to the purchase date of the original unit.
This warranty gives you certain legal rights which may
change from state to state. Your state may also have
other rights you may be entitled to that are not listed
within this warranty.
Contact Information
Warranty Exclusions
This warranty does not cover the following repairs and
equipment:
Normal Wear
Generators need periodic parts and service to perform well.
This warranty does not cover repair when normal use has
exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if this
generator is deemed to have been misused, neglected,
involved in an accident, abused, loaded beyond the
generator’s limits, modified, installed improperly or
connected incorrectly to any electrical component.
Address
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670
www.championpowerequipment.com
United States Environment Protection Agency (U.S. EPA)
Emission Control System Warranty
Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA AND CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2014 small
off-road engine and engine powered equipment. New engines and equipment must be designed, built and
equipped, at the time of sale, to meet U.S. EPA regulations for small non-road engines. CPE warrants the emission
control system on your small off-road engine and equipment for the period of time listed below, provided there has
been no abuse, neglect, unapproved modification, or improper maintenance of your equipment.
Your emission control system may include parts such as the carburetor, fuel-injection system, the ignition system,
catalytic converter and fuel lines. Also included may be hoses, belts, connectors and other emission related
assemblies. Where a warrantable condition exits, CPE will repair your small off-road engine at no cost to you
including diagnosis, parts and labor.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions set forth below. If, during the
warranty period, emission related part on your engine is defective in materials or workmanship, the part will be
repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine owner, you are responsible for the performance of the required maintenance listed in
your Owner’s Manual. CPE recommends that you retain all your receipts covering maintenance on your small offroad engine, but CPE cannot deny warranty solely for the lack of receipts or for your failure to ensure the
performance of all scheduled maintenance.
As the small off-road engine owner, you should however be aware that CPE may deny you warranty coverage if
your small, off-road engine or a part has failed due to abuse, neglect, improper maintenance or unapproved
modifications.
You are responsible for presenting your small off-road engine to an Authorized CPE service outlet or alternate
service outlet as described in (3)(f.) below, CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem exists.
The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, you should contact:
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage.
1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines. The ECS
Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use
purchaser, and shall continue for 24 consecutive months thereafter.
2. GENERAL EMISSIONS WARRANTY COVERAGE
CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent
purchaser that each of its small off-road engines is:
a. Designed, built and equipped so as to conform to U.S. EPA emissions standards for spark-ignited
engines at or below 19 kilowatts.
b. Free from defects in materials and workmanship that cause the failure of a warranted part to be identical
in all material respects to the part as described in the engine manufacturer’s application for certification for a period
of two years.
3. THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
a. Any warranted part that is not scheduled for replacement as required maintenance in the Owners
Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it
shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under
the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period.
b. Any warranted, emissions-related part which is scheduled only for regular inspection as specified in the
Owners Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the
effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or
replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
c. Any warranted, emissions-related part which is scheduled for replacement as required maintenance in
the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that
part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE
according to Subsection “d” below. Any such emissions-related part repaired or replaced under the ECS Warranty,
shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for
such emissions-related part.
d. Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be
performed at no charge to the owner at a CPE Authorized Service Outlet.
e. The owner shall not be charged for diagnostic labor which leads to the determination that a part covered
by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized
Service Outlet.
f. CPE shall pay for covered emissions warranty repairs at non-authorized service outlets under the
following circumstances:
i. The service is required in a population center with a population over 100,000 according to U.S.
Census 2000 without a CPE Authorized Service Outlet AND
ii. The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile
limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska,
Nevada, New Mexico, Oregon, Texas, Utah and Wyoming.
g. CPE shall be liable for damages to other original engine components or approved modifications
proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty.
h. Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted emission-related parts
sufficient to meet the expected demand for such emission-related parts.
i. Any CPE Authorized and approved emission-related replacement part may be used in the performance of
any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not
reduce CPE’s warranty obligation.
j. Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids
this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable
hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or
modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the
engine)
Systems covered by this
warranty
Parts Description
Fuel Metering System
Fuel regulator, Carburetor and internal parts
Air Induction System
Air cleaner, Intake manifold
Ignition System
Spark plug and parts, Magneto ignition system
Exhaust System
Exhaust manifold, catalytic converter
Miscellaneous Parts
Tubing, Fittings, Seals, Gaskets, and Clamps associated with these listed
systems.
Evaporative Emissions
Fuel Tank, Fuel Cap, Fuel Line, Fuel Line Fittings, Clamps, Pressure
Relief Valves, Control Valves, Control Solenoids, Electronic Controls,
Vacuum Control Diaphragms, Control Cables, Control Linkages, Purge
Valves, Vapor Hoses, Liquid/Vapor Separator, Carbon Canister, Canister
Mounting Brackets, Carburetor Purge Port Connector
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or
other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is
authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business
hours. Alternate service locations defined in Section (3)(f.) above must be approved by CPE prior to service. Claims
for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because
the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities, or to obtain warranty
service, please write or call Customer Service at Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.