Tone Generator & Probe
Introduction
User Manual
E. Testing Continuity
1. Slide the toggle switch to the "Cont" position.
2. Connect the test leads to the subject pair.
3. A BRIGHT GREEN light indicates continuity.
The Tone Generator is a highly practical network installation
and troubleshooting tool which features a single or multiĀtone signal, two test leads and a 4-conductor modular cable.
The signal emitted by the Tone Generator can be easily traced
by the Probe, even when cables are in a bundle or hidden in a
mess of punch down blocks or wall plates. The Tone
Generator & Probe can be used to verify cable continuity,
identify wiring faults, determine line polarity and voltage in
network (Cat 5 and Coax) and modular telephone lines. The
Probe is equipped with a tone amplifier and an LED indicator
that detects audible frequency tones for accurate tracing and
identification of wires.
Product Profile
TOGGLE SWITCH
1
RED TEST LEAD
2
BLACK TEST LEAD
3
BATTERY LOW
4
5
LED DISPLAY
TONE SELECTING SWITCH
6
7
4 PIN MODULAR CABLE
2
7
3
1
Cont
Off Tone
5
TONE GENERATOR
BAD
GOOD
4
DUAL TONE
SINGLE TONE
BAT.LOW
1
5
2
3
6
4
6
CABLE
TRACER
7
8
1
PROBE
2
SIGNAL
3
LOW BAT.
4
TRACE
5
VOLUME
6
DISPLAY MODE
7
SPEAKER
8
9V BAT.
Tone Generator
Features:
* 2-position switch for single tone or multi-tone signal
* Toggle switch to control 3 modes of operation
* 3-color LED indicator display for telephone line
Caution:
Do not connect to an active AC or DC circuit in this
mode.
F. Testing Continuity Using Tone
1. Slide the toggle switch to the "Tone" position.
2. Connect the test leads to the subject pair.
3. Using a handset or headset at the remote end,
touch the wire end(s) with the clip lead(s).
4. Reception of tone is an indication of continuity.
Modular Testing
* All above tests are applicable to modular plugs for line 1
only (red & green wires).
Coax Testing
* To test un-terminated coaxial cables, connect the RED
test lead to the outer shield and the BLACK test lead to
the center conductor, or connect the RED test lead to the
outer shield and the BLACK test lead to the ground.
* To test terminated coaxial cables, connect the RED test
lead to the connector housing and the BLACK test lead
to center pin, or connect the RED test lead to the
connector housing and the BLACK test lead to ground.
1 6
* One push-button TRACE switch
* One battery low LED indicator
* One amplifier and one LED for signal detection
* One rotary volume level switch
Operation
A. Identifying the polarity of a telephone line
Cont
Off Tone
TONE GENERATOR
BAD
GOOD
DUAL TONE
SINGLE TONE
BAT.LOW
5. LED indicator results:
a. GREEN light: indicates normal polarity
b. RED light: indicates reversed polarity
c. YELLOW light: indicates presence of AC
Note: If a ground is not available, you may try to switch the
test leads around to different wires within the pair.
The LED indicator will light GREEN when the red test
lead is connected to the ringside of the line and the
black lead is connected to the ground.
1. Load the 9V battery
2. Slide the toggle switch to the
"Off" position
3. Connect the black test lead to ground
4. Connect red test lead to the line you
wish to test
power on the telephone line
B. Indicating telephone Line Condition
1. Load the 9V battery.
2. Slide the toggle switch to the "Off" position.
3. Plug the standard 4-pin modular cable into
modular wall jack.
4. LED indicator results:
a. BRIGHT GREEN light: indicates a clear line.
b. DIM GREEN light: indicates a busy line.
c. BRIGHT FLASHING RED and GREEN light:
indicates a ringing line.
Note: A DIMLY FLASHING GREEN light will result under
ringing line conditions if the line's polarity is reversed. If the
test is begun prior to an incoming call, the call will be
blocked.
C. Verifying telephone Lines
1. Slide the toggle switch to the "Cont" position.
2. Dial the number of the line you wish to verify.
3. While the line is ringing, connect the red lead to
the ring side of the line, and connect the black
lead to ground.
4. Slide the toggle switch to the "Off" position. The
LED indicator will flicker RED and GREEN
when the test leads are connected to the subject
pair.
5. To verify identification, monitor the line and
switch the test set to "Cont." This will terminate
the call on the subject line.
3 4