1. Introduction 1
LANtest Pro
2. Features 1
LANtest Pro Specifications 2
3.
LANtest Pro Cable Test Operation 3
4.
5 LANtest Pro Tone Generator Operation 3
.
6 LANtest Pro Remote ID Operation 4
.
7. Probe Features 4
8. Probe Specifications
9. Probe Operation 5
10
. Product Profile 5
11. Fault Status 8
. Battery Replacement . Warning
Introduction
Congratulations on your purchase of the LANtest Pro network cable tester series! The LANtest Pro is a small hand-held cable tester, which enables network professionals to quickly and easily verify the integrity of Ethernet twisted pair cables. In one step, the LANtest Pro will test twisted pair cables for open pairs, shorted pairs, reversed pairs, crossed pairs and split pairs. Just push the TEST button, and the LANtest Pro will automatically scan for any existing faults in your cable. The specially designed remote terminator is provided for one-person testing of installed cables. The tone generator function can be used to send a signal through your installed cables which can be traced with the Probe or any cable tracer in the market.
Package Contents:
Item Number Remotes Manual Soft carry case Probe Probe with filter 256652/LB
256652/LBT 256652/IDT 256652/TK 256652/TFK
1 Y Y N N 1 Y Y N N 4 Y Y N N 1 Y Y Y N 1 Y Y Y Y
For 256652/IDT & 256652/LBT Users can buy 256712A or 256712F to Upgrade the tone function
LANtest Pro Features
Tests for wiring faults of open, short, reversed, crossed and split pairs Split pair fault detection at a minimum 40cm cable length Testing of twisted pair cables to over 450ft Tone generator for tracing installed cables and locating faults (available on models 256652/LBT, 256652/TK, 256652/TFK and 256652/IDT) Identification of up to 4 remote termination units (available
1
on model 256652/IDT) Verification of shield integrity Cross talk detection in excess of 3dB + 0.3dB at 3.5Mhz between any two pairs Specially designed remote unit that enables one person to test installed cables Easy to read fault display and high speed testing Debug mode for detailed fault identification results Auto sleep mode and power off switch to decrease power consumption
LANtest Pro Specifications
Connectors
LANtest Pro Main Unit RJ45 jack
Remote Unit RJ45 jack Pairs tested 1/2, 3/6, 4/5, 7/8 and shield
LED display
Horizontal: 5 Green LEDs for pair and shield display (1-2, 3-6, 4-5, 7-8 and shield) TONE G. LED (for models 256652/LBT, 256652/TK,
256652/TFK and 256652/IDT) Vertical: 5 Red LEDs for fault display and #ID display (OPEN, SHORT, REVERSED, MISWIRE,
SPLIT PAIRS and LOW BATTERY) For 256652/IDT the fault display shares with the #ID Display (#1, #2, #3, #4)
Cable test length limit
Minimum: 0.4m Maximum: Over 200m Power: LANtest Pro: 6V alkaline DC battery Remote identifier: No battery required
Dimensions:
LANtest Pro: 125 x 52 x 30 mm (L x W x H) Low battery indicator
LANtest Pro Cable Test Operation:
1.Select "Cable" position on the toggle switch.
2.Plug one end of the subject cable into the RJ45 jack on the master unit and the other end into the RJ45 jack on the remote terminator.
Note: The remote terminator can be slipped and locked into the
master unit for convenient testing of patch cables.
3.Push the test button and check the results: First, check the 5 horizontally aligned green LED indicators (1-2, 3­6, 4-5, 7-8, SHIELD) for integrity status:
Solid light : pair is OK Flashing light : pair is faulty No light : open pair
a. Simultaneously, check the 5 vertically aligned LED
indicators (SHORT, REVERSED, MISWIRE, SPLIT PAIRS) for the wiring faults.
b. For more detailed information about what faults are
occurring in which pairs, hold the TEST button for 2 seconds to activate "Debug mode." The tester will test each pair one by one, pausing briefly on each pair, and display the corresponding fault status.
LANtest Pro Tone Generator Operation (only available on models 256652/LBT, 256652/TK, 256652/TFK and 256652/IDT):
1. Slide the toggle switch on the LANtest Pro to the "Tone" position
2. Quickly press the TEST button once for continuous tone mode, or hold down for two full seconds for warble tone
2 3
mode. To change modes, switch tester off and restart.
3. Using switch on side of Probe, select "speaker mode," "LED mode" or "speaker & LED mode."
4. Use the Probe or any cable tracer to trace the subject wire. Reception of tone will be loudest (amplifier) or brightest (LED) on the subject wire.
LANtest Pro Remote ID Operation (available on model 256656/IDT)
1. Select "Cable" position on the toggle switch.
2. Plug one end of the subject cable into the RJ45 jack on the master unit and the other end into the RJ45 jack on the remote terminator.
3. Press the TEST button. One of the ID LED's will flash
three times. This indicates the number of the remote identification unit attached to the far end of the subject cable. The tester will then automatically continue with the same cable test procedure as the standard LANtest Pro.
Probe Specifications:
Pen-style casing Special inductive plastic tip One push-button TRACE switch One battery low LED indicator One amplifier and one LED for signal detection One rotary volume level switch
Probe Operation:
1. With the toggle switch on the side of the Probe unit, select the mode of operation:
a. S & L: Speaker amplifier and LED tracing mode b. Sp. : Speaker only tracing mode c. L : LED only tracing mode
2. Press and hold the TRACE button while approaching the subject cable. The intensity of the tone signal will increase as the Probe approaches the cable.
Probe Features:
Special inductive plastic tip which prevents accidental
shorts (possible with copper-tip tracers) when using near high voltage devices Traces and identifies wires or cable in a bundle or group without damaging cable insulation Adjustable volume level for various work environments
Both amplifier and LED for loud or dark work
environments
Can work with any existing tone generator in the market
4 5
Product Profile
256652/LB
1. Master port (RJ45)
2. Pair 1 indicator
3. Pair 2 indicator
4. Pair 3 indicator
5. Pair 4 indicator
6. Shield indicator
7. Short faults LED
8. Reversed faults LED
9. Miss wire faults LED
10. Split pairs LED
11. Battery low indicator
12. Test button
13. ON/OFF switch
14. Battery cover
15. Remote unit
16. Remote test port (RJ45)
LANtest
Remote Network Cable Tester
15
TM
Pro
16
2
3
12
14
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
LANtest
Remote Network Cable Tester
Pro
1
4
5
6
7
8
9
10
11
13
TM
256652/LBT (with tone generator model)
1. Master port (RJ45)
2. Pair 1 indicator
3. Pair 2 indicator
4. Pair 3 indicator
5. Pair 4 indicator
6. Shield indicator
7. Short faults LED
8. Reversed faults LED
9. Miss wire faults LED
10. Split pairs LED
11. Battery low indicator
12. Test button
13. ON/OFF switch
14. Battery cover
15. Remote unit
16. Remote test port (RJ45)
17. Tone indicator
LANtest
Remote Network Cable Tester
15
TM
Pro
16
1-2 3-6 4-5 7-8 SHIELD
ID
TONE G.
SHORT
1
TEST
REVERSED
2
MISWIRE
2
3
17
12
14
SPLIT PAIRS
LOW BATTERY
LANtest
Remote Network Cable Tester
3
4
TM
Pro
256652/IDT LANtest Pro with tone generator and 4 remote IDs
15
1. Master port (RJ45)
2. Pair 1 indicator
3. Pair 2 indicator
4. Pair 3 indicator
5. Pair 4 indicator
6. Shield indicator
7. Short faults LED
8. Reversed faults LED
9. Miss wire faults LED
10. Split pairs LED
11. Battery low indicator
12. Test button
13. Cable/Tone generator/OFF switch
14. Battery cover
15. Remote unit #1
16. Remote unit #2
17. Remote unit #3
18. Remote unit #4
19. Remote test port (RJ45)
20. Tone indicator
16
17
18
1
Remote
Terminator
2
Remote
Terminator
3
Remote
Terminator
4
Remote
Terminator
1-2 3-6 4-5 7-8 SHIELD
TONE G.
2
20
14
TEST
3
12
LANtest
Remote Network Cable Tester
19
LOW BATTERY
REVERSED
SPLIT PAIRS
256652/TK 256652/LBT with 256712A Probe
1
4
5
6
7
8
9
10
11
13
1. Master port (RJ45)
2. Pair 1 indicator
3. Pair 2 indicator
4. Pair 3 indicator
5. Pair 4 indicator
6. Shield indicator
7. Short faults LED
8. Reversed faults LED
9. Miss wire faults LED
10. Split pairs LED
11. Battery low indicator
12. Test button
13. ON/OFF switch
14. Battery cover
15. Remote unit
16. Remote test port (RJ45)
LANtest
Remote Network Cable Tester
15
TM
Pro
16
1-2 3-6 4-5 7-8 SHIELD
TONE G.
2
3
17
12
LANtest
Remote Network Cable Tester
14
1
4
5
6
7
8
ID 1
SHORT
TEST
2
REVERSED
10
3
MISWIRE
4
SPLIT PAIRS
11
LOW BATTERY
13
TM
Pro
1
9
2
3
5
6
4
CABLE
TRACER
1. Inductive Plastic Tip
2. Visible Signal indicator
3. Low Battery
4. Trace button
5. Volume
6. Light /Speaker & Light/off switch
7. Speaker
8. Battery Cover
7
8
256652/TFK 256652/LBT with 256712F Probe (with Filter)
1
4
5
6
7
8
ID 1
SHORT
2
3
MISWIRE
4
TM
Pro
9
10
11
13
1. Master port (RJ45)
2. Pair 1 indicator
3. Pair 2 indicator
4. Pair 3 indicator
5. Pair 4 indicator
6. Shield indicator
7. Short faults LED
8. Reversed faults LED
9. Miss wire faults LED
10. Split pairs LED
11. Battery low indicator
12. Test button
13. ON/OFF switch
14. Battery cover
15. Remote unit
16. Remote test port (RJ45)
LANtest
Remote Network Cable Tester
15
TM
Pro
16
1-2 3-6 4-5 7-8 SHIELD
TONE G.
TEST
2
3
17
12
LANtest
Remote Network Cable Tester
14
1
4
5
6
7
8
ID
9
1
SHORT
2
REVERSED
10
3
MISWIRE
4
SPLIT PAIRS
11
LOW BATTERY
13
TM
Pro
1
2
3
NOISE FILTER
INCLUDED
4
CABLE
TRACER
1. Inductive Plastic Tip
2. Visible Signal indicator
3. Low Battery
4. Trace button
5. Volume
6. Light /Speaker & Light/off switch
7. Speaker
8. Battery Cover
5
6
7
8
6 7
Fault Status
Short
Open
Reversed
Miss-wire
Split
Low Battery
1
2
3 6
4 5
7 8
1
2
3 6
4 5
7 8
1 2
3 6
4 5
7 8
1 2
3 6
4 5
7 8
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
Battery Replacement
When the LOW BATTERY light illuminates, the battery does not have sufficient power to support an accurate test. At this time, you must replace it with a new battery.
Battery
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
1 2
3 6
4 5
7 8
1 2
3 6
4 5
7 8
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
Warning
1
2
3 6
4
7 8
1 2
3 6
4 55
7 8
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
1. Do not connect LANtest Pro to a live circuit as it may damage the tester and interfere with a live network.
2. Testing in a high frequency activated area may cause the tester to give inaccurate readings.
3. Do not drop or get the tester wet as it may cause internal damage.
4. Do not place the tester in areas of high humidity or direct
1 2
3 6
4 5
7 8
1 2
3 6
4 5
7 8
1-2 3-6 4-5 7-8 SHIELD
SHORT
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
sunlight.
5. Do not open the tester or attempt to repair in case of malfunction. Please send it back to your distributor for repair or replacement.
8
9
Loading...