-- High resolution 500 dpi optical ngerprint sensor.
-- Maximum security proximity reader for MIFARE Plus® cards
and MIFARE® DESFire® EV1, MIFARE® Classic and MIFARE
Ultralight® cards available on demand.
-- Proximity card reader from a distance of 3 to 5 cm.
-- Acoustic-light indicators to show when the credentials have
been granted or denied access, in addition to the reader operating
mode (ngerprint only, card only, ngerprint or card, etc.).
-- Capacity for up to 9,500 users with ngerprints on card.
-- Wear-resistant surface nish.
-- Flush mounted for indoor use.
REGULATIONS
ISO/IEC 14443 A and B.
AES128 NIST FIPS PUB 197 MIFARE Plus® certicado de acuerdo a Common Criteria level EAL4+ .
NFC MIFARE® emulation compliant.
NFC MIFARE® emulation compilant.
EN 60950-1 2001 and A1: 2004.
EN 300 330-2 v1.3.1.
3
NÜO PASS Manual
IntroductionFeatures
TECHNICAL SPECIFICATIONS
NÜO PASS:
INPUT VOLTAGE24 VDC (11 - 28 VDC)
MAXIMUM POWER5 W
READING DISTANCE3 - 5 cm
FINGERPRINT SENSOR TYPEOptical
SENSOR RESOLUTION
MAX. NO. FINGERPRINTS9,500 ngerprints (1:1) - 1,000 (1:N)
COMMUNICATIONS BUS RS-485
INPUTS1 Door sensor input
OUTPUTS
ILLUMINATION
500 dpi
1 Output for lock control
24 vDC / (250 mA maximum)
Colours according to status:
RED/WHITE: Terminal oine
DEGRADED RED/PINK: Terminal in enrolment mode
FLASHING BLUE: Terminal in rmware update mode.
BLUE: Terminal on standby / standard security
GREEN: Access granted / Unrestricted
RED: Access denied / Door blocked
WHITE: Reading ngerprint/card
FLASHING WHITE: Fingerprint enrolment
PURPLE: High security mode
PINK: Very high security mode
YELLOW/GREEN: Emergency
FLASHING YELLOW: Connected but not congured
Technical Specications
AUDIO
OPERATING
TEMPERATURE
READER DIMENSIONS140 x 80 x 54 mm (height x width x depth)
Dierentiated sound indicators for granted and denied access
and statuses.
-10 °C to 50 °C
4
NÜO PASS Manual
Introduction
FeaturesWiring
TYPE OF WIRING AND WIRING DISTANCE:
The NÜO PASS incorporates a male overhead connector.
NÜO PASS is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector
at one end to correctly connect it.
The other end of the piped cable is connected to a single door controller or to the corresponding Wili
following the simple colour coding.
O/W
G/W
+
-
A
BY B US
B
Orange
Green
3.5 metres of cable
NÜO PASS
The wiring distance from the reader and the single door controller or Wili should not
exceed 25 metres in length under any circumstances.
WIRING SPECIFICATIONS:
The built-in piped cable used to connect the reader has the following technical characteristics:
- Gauge: 0.22 mm
- Arrangement: 2 twisted pairs
- Resistance: <2 Ohms
DISTANCE BETWEEN READERS:
A minimum distance of 12 cm must be maintained if installations are made with doors with 2 input/
output readers or with 2 readers that are very close together.
5
NÜO PASS Manual
Installation
-- STEPS PRIOR TO INSTALLATION:
1) Remove the front panel using the suction
cup provided. The panel will be easier to
remove if the suction cup is placed in a corner.
-- INSTALLATION ON BUILT WALLS:
3) Using a level, make a hole in the wall with
the dimensions detailed in the diagram. Pass
the connecting cable through and grout the
hole.
NÜO PASSInstallation on built walls
Plaster
50
2) Unscrew the ush mount support.
4) Insert the ush mount support and pass the
cable through one of the holes, then connect
the assembly.
128
68
128 x 68 x 50 mm
5) Tighten the screws, fastening the assembly
to the ush mount base.
6) Place the front panel.
6
NÜO PASS Manual
Installation
-- INSTALLATION IN PLASTERBOARD (THICKNESS 10 - 25mm)
1) Follow the initial steps listed in page 6.
2) Make a hole in the plasterboard with the
dimensions detailed in the diagram.
128 x 68 mm
4) Connect the cable to the assembly that was
removed beforehand.
NÜO PASS
68
128
Installation in plasterboard (thickness 10 - 25mm)
3) Insert the ush mount support and pass the
cable through one of the holes, then secure it in
place in the plasterboard using the tabs.
5) Tighten the assembly (1) and place the front
panel (2).
12
7
NÜO PASS Manual
InstallationNÜO PASS
-- INSTALLATION ON CONCRETE WALLS:
1) Follow the initial steps listed in page 6.
2) Make 4 holes at the distance marked for Fis-
cher 5mm wall plugs.
70
130
Distance between holes 130 x 70mm
4) Connect the wiring pipe and pass the cable
through, connecting the equipment.
Installation on concrete walls
3) Secure the mounting box using the 4 Fischer
wall plugs and the screws supplied.
Mounting box: 42170
5) Tighten the screws and place the front
panel.
8
NÜO PASS Manual
66
Installation
NÜO PASSInstallation in other environments
-- INSTALLATION IN OTHER ENVIRONMENTS:
1) Follow the initial steps listed in page 6.
2) Make 4 M3 holes and another hole with the
dimensions detailed in the diagram, taking the
radii or chamfer dimensions into consideration.
58.7
26.5
15.84
118.69
56.49
15.84
4
5
°
32.2
33
5
.
8
1
R
(x4) Inserto S-M3
5
.
8
1
R
126
118.7
63
62.2
58.7
3) Connect the cable to the equipment and
fasten it using screws.
Units: mm
Machining on minimum thickness plate: 1.2 mm
4) Place the front panel.
Install the equipment on outdoor
or indoor surfaces that are free
from vibrations.
9
NÜO PASS Manual
Orange
Orange/White
Green
RS-485-A
RS-485-B
+
24VDC
BY B U S
Green/White
0V / GND
COLOUR
SIGNAL
Installation
NÜO PASS readers can be directly connected to two types of devices depending on the architecture
of the installation:
-- Connection to a Wili.
-- Connection to a single door controller.
The connection to be made for both types of devices is exactly the same. The colour code must be
followed. For more detailed information, consult the equipment manuals referenced earlier.
NÜO PASSWiring
RS-485 A
GND (0V)
+24 VDC
READER WIRING:
RS-485 B
Wire mesh
Install and connect the reader before powering the system.
NÜO readers use the 24 VDC input voltage corresponding to the controller equipment to
which they are connected, the power sources of which are rigorously prepared for such
purpose.
These signals must be perfectly isolated in order to prevent damaging the equipment or
installation.
10
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipmentÿ
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
June 2018Version: 03MT:17173
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.