By TechDesign SL MTA42106 User Manual

Installation manual
NÜO PASS
42106 | 42142
2
NÜO PASS Manual
Introduction Features
GENERAL FEATURES
NÜO PASS (Ref. no. 42106 and 42142)
-- High resolution 500 dpi optical ngerprint sensor.
-- Maximum security proximity reader for MIFARE Plus® cards
and MIFARE® DESFire® EV1, MIFARE® Classic and MIFARE Ultralight® cards available on demand.
-- Proximity card reader from a distance of 3 to 5 cm.
-- Acoustic-light indicators to show when the credentials have
been granted or denied access, in addition to the reader operating
mode (ngerprint only, card only, ngerprint or card, etc.).
-- Capacity for up to 9,500 users with ngerprints on card.
-- Wear-resistant surface nish.
-- Flush mounted for indoor use.
REGULATIONS
ISO/IEC 14443 A and B.
AES128 NIST FIPS PUB 197 MIFARE Plus® certicado de acuerdo a Common Criteria level EAL4+ .
NFC MIFARE® emulation compliant.
NFC MIFARE® emulation compilant.
EN 60950-1 2001 and A1: 2004.
EN 300 330-2 v1.3.1.
3
NÜO PASS Manual
Introduction Features
TECHNICAL SPECIFICATIONS
NÜO PASS:
INPUT VOLTAGE 24 VDC (11 - 28 VDC)
MAXIMUM POWER 5 W
READING DISTANCE 3 - 5 cm
FINGERPRINT SENSOR TYPE Optical
SENSOR RESOLUTION
MAX. NO. FINGERPRINTS 9,500 ngerprints (1:1) - 1,000 (1:N) COMMUNICATIONS BUS RS-485 INPUTS 1 Door sensor input
OUTPUTS
ILLUMINATION
500 dpi
1 Output for lock control
24 vDC / (250 mA maximum)
Colours according to status:
RED/WHITE: Terminal oine
DEGRADED RED/PINK: Terminal in enrolment mode
FLASHING BLUE: Terminal in rmware update mode.
BLUE: Terminal on standby / standard security GREEN: Access granted / Unrestricted RED: Access denied / Door blocked
WHITE: Reading ngerprint/card
FLASHING WHITE: Fingerprint enrolment PURPLE: High security mode PINK: Very high security mode YELLOW/GREEN: Emergency
FLASHING YELLOW: Connected but not congured
Technical Specications
AUDIO
OPERATING TEMPERATURE
READER DIMENSIONS 140 x 80 x 54 mm (height x width x depth)
Dierentiated sound indicators for granted and denied access
and statuses.
-10 °C to 50 °C
4
NÜO PASS Manual
Introduction
Features Wiring
TYPE OF WIRING AND WIRING DISTANCE:
The NÜO PASS incorporates a male overhead connector. NÜO PASS is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector at one end to correctly connect it. The other end of the piped cable is connected to a single door controller or to the corresponding Wili following the simple colour coding.
O/W
G/W
+
-
A
BY B US
B
Orange
Green
3.5 metres of cable
NÜO PASS
The wiring distance from the reader and the single door controller or Wili should not exceed 25 metres in length under any circumstances.
WIRING SPECIFICATIONS:
The built-in piped cable used to connect the reader has the following technical characteristics:
- Gauge: 0.22 mm
- Arrangement: 2 twisted pairs
- Resistance: <2 Ohms
DISTANCE BETWEEN READERS:
A minimum distance of 12 cm must be maintained if installations are made with doors with 2 input/ output readers or with 2 readers that are very close together.
5
NÜO PASS Manual
Installation
-- STEPS PRIOR TO INSTALLATION:
1) Remove the front panel using the suction cup provided. The panel will be easier to remove if the suction cup is placed in a corner.
-- INSTALLATION ON BUILT WALLS:
3) Using a level, make a hole in the wall with the dimensions detailed in the diagram. Pass the connecting cable through and grout the hole.
NÜO PASS Installation on built walls
Plaster
50
2) Unscrew the ush mount support.
4) Insert the ush mount support and pass the
cable through one of the holes, then connect the assembly.
128
68
128 x 68 x 50 mm
5) Tighten the screws, fastening the assembly to the ush mount base.
6) Place the front panel.
6
NÜO PASS Manual
Installation
-- INSTALLATION IN PLASTERBOARD (THICKNESS 10 - 25mm)
1) Follow the initial steps listed in page 6.
2) Make a hole in the plasterboard with the
dimensions detailed in the diagram.
128 x 68 mm
4) Connect the cable to the assembly that was
removed beforehand.
NÜO PASS
68
128
Installation in plasterboard (thickness 10 - 25mm)
3) Insert the ush mount support and pass the
cable through one of the holes, then secure it in place in the plasterboard using the tabs.
5) Tighten the assembly (1) and place the front panel (2).
1 2
7
NÜO PASS Manual
Installation NÜO PASS
-- INSTALLATION ON CONCRETE WALLS:
1) Follow the initial steps listed in page 6.
2) Make 4 holes at the distance marked for Fis-
cher 5mm wall plugs.
70
130
Distance between holes 130 x 70mm
4) Connect the wiring pipe and pass the cable
through, connecting the equipment.
Installation on concrete walls
3) Secure the mounting box using the 4 Fischer wall plugs and the screws supplied.
Mounting box: 42170
5) Tighten the screws and place the front
panel.
8
NÜO PASS Manual
66
Installation
NÜO PASS Installation in other environments
-- INSTALLATION IN OTHER ENVIRONMENTS:
1) Follow the initial steps listed in page 6.
2) Make 4 M3 holes and another hole with the
dimensions detailed in the diagram, taking the radii or chamfer dimensions into consideration.
58.7
26.5
15.84
118.69
56.49
15.84
4
5
°
32.2
33
5
.
8
1
R
(x4) Inserto S-M3
5
.
8
1
R
126
118.7
63
62.2
58.7
3) Connect the cable to the equipment and fasten it using screws.
Units: mm
Machining on minimum thickness plate: 1.2 mm
4) Place the front panel.
Install the equipment on outdoor or indoor surfaces that are free from vibrations.
9
NÜO PASS Manual
Orange
Orange/White
Green
RS-485-A
RS-485-B
+
24VDC
BY B U S
Green/White
0V / GND
COLOUR
SIGNAL
Installation
NÜO PASS readers can be directly connected to two types of devices depending on the architecture of the installation:
-- Connection to a Wili.
-- Connection to a single door controller.
The connection to be made for both types of devices is exactly the same. The colour code must be followed. For more detailed information, consult the equipment manuals referenced earlier.
NÜO PASS Wiring
RS-485 A
GND (0V)
+24 VDC
READER WIRING:
RS-485 B
Wire mesh
Install and connect the reader before powering the system.
NÜO readers use the 24 VDC input voltage corresponding to the controller equipment to which they are connected, the power sources of which are rigorously prepared for such purpose.
These signals must be perfectly isolated in order to prevent damaging the equipment or installation.
10
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipmentÿ Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
June 2018Version: 03MT:17173