BW Technologies Micro Clip XT, Micro Clip XL Operator's Manual

Page 1
1, 2, 3, and 4-Gas Detector
Operator Manual
Page 2
1
GasAlertMicroClip
Introduction
The operator’s manual provides basic information for the GasAlertMicroClip XT and XL. For complete operating
instructions, refer to the GasAlertMicroClip Technical Reference Guide provided on the CD-ROM. The GasAlertMicroClip (“the
detector”) warns of hazardous gas at levels above user-defined alarm setpoints. The detector is a personal safety device. It is your responsibility to respond properly to the alarm.
Note
The detector is shipped with English as the default displayed language. Additional languages provided are Portuguese, Spanish, German, and French. The screens for the additional languages are displayed on the detector and in the corresponding operator s manuals.
Zeroing the Sensors
To zero the sensors, refer to steps #1-3 in Calibration on page 7.
ec Warning
This instrument contains a lithium polymer battery. Dispose of lithium cells immediately. Do not disassemble and do not dispose of in fire. Do not mix with the solid waste stream. Spent batteries should be disposed of by a qualified recycler or hazardous materials handler.
Page 3
GasAlertMicroClip
Operator’s Manual
2
Safety Information - Read First
Use the detector only as specified in this manual and the reference guide, otherwise the protection provided by the detector may be impaired. Read the following cautions before using the detector.
a
Cautions
Warning: Substitution of components may impair Intrinsic Safety.
• Caution For safety reasons, this equipment must be operated and serviced by qualified personnel only. Read and understand the user manual completely before operating or servicing.
• Charge the detector before first time use. BW recommends the detector be charged after every workday.
• Before using the detector, refer to Sensor Poisons and Contaminants.
• Calibrate the detector before first-time use and then on a regular schedule, depending on use and sensor exposure to poisons and contaminants. BW recommends calibrating at least once every 180 days (6 months).
• The combustible sensor is factory calibrated to 50% LEL methane. If monitoring a different combustible gas
in the %LEL range, calibrate the sensor using the appropriate gas.
• Only the combustible gas detection portion of this instrument has been assessed for performance by CSA International.
• Calibrate only in a safe area that is free of hazardous gas and in an atmosphere of 20.9% oxygen.
• It is recommended that the combustible sensor be checked with a known concentration of calibration gas after any exposure to contaminants/poisons such as, sulfur compounds, silicon vapors, halogenated compounds, etc.
• BW recommends to bump test the sensors before each day’s use to confirm their ability to respond to gas by exposing the detector to a gas concentration that exceeds the alarm setpoints. Manually verify that the audible and visual alarms are activated. Calibrate if the readings are not within the specified limits.
• Caution High off-scale readings may indicate an explosive concentration.
• Any rapid up scaling reading followed by a declining or erratic reading may indicate a gas concentration beyond the upper scale limit, which can be hazardous.
• Extended exposure of the GasAlertMicroClip to certain concentrations of combustible gases and air may stress a detector element that can seriously affect its
Page 4
GasAlertMicroClip
performance. If an alarm occurs due to a high concentration of combustible gases, calibrate the detector. If necessary, replace the sensor.
• Protect the combustible sensor from exposure to lead compounds, silicones, and chlorinated hydrocarbons.
• Sensor exposure to certain organic vapors (such as leaded gasoline and halogenated hydrocarbons) may temporarily inhibit sensor performance. After exposure, a bump test or calibration is recommended.
• For use only in potentially explosive atmospheres where oxygen concentrations do not exceed 20.9% (v/v).
Page 5
GasAlertMicroClip
Operator’s Manual
6
Parts of the GasAlertMicroClip
8
6
9
4
5
3
7
10
11
2
2
1
2
Item Description
1 IntelliFlash
2 Visual alarm indicators (LEDs)
3 Alligator clip
4 Charging connector / IR interface
5 Pushbutton
6 Carbon monoxide (CO) sensor
7 Hydrogen sulfide (H2S) sensor
8 Oxygen (O2) sensor
9 Combustible (LEL) sensor
10 Audible alarm
11 Liquid crystal display (LCD)
Page 6
GasAlertMicroClip
Display Elements
7
Display Elements
1
8
7
6
5
4
3
2
Item Description
1 Alarm condition
2 Automatically zero sensor
3 Numeric value
4 Stealth mode
5 Battery life indicator
6 Gas identifier bars
7 Gas cylinder
8 Automatically span sensor
Page 7
GasAlertMicroClip
Operator’s Manual
8
Pushbuttons
Pushbutton Description
C
• To activate the detector, press C.
• To deactivate the detector, press and hold C until the OFF countdown is complete and the LCD deactivates
• To view the TWA, STEL, and MAX (maximum) readings, press C twice. To clear the TWA, STEL, and MAX
readings, press C when the LCD displays RESET.
• To initiate calibration, deactivate the detector. Press and hold C while the detector performs the OFF countdown. Continue holding C while the LCD briefly deactivates and then begins the CAL countdown. Release C when the CAL countdown is complete.
• To activate the backlight while in normal operation, press C.
• To acknowledge latched alarms, press C.
• To acknowledge a low alarm and disable the audible alarm, press C (if the Low Alarm Acknowledge option is enabled).
Page 8
GasAlertMicroClip
Sensor Poisons and Contaminants
9
Sensor Poisons and Contaminants
Several cleaners, solvents, and lubricants can contaminate and
cause permanent damage to sensors. Before using cleaners,
solvents, and lubricants in close proximity to the detector
sensors, read the following caution and table.
a
Caution
Use only the following BW Technologies by Honeywell recommended products and procedures
• Use water based cleaners.
• Use non-alcohol based cleaners.
• Clean the exterior with a soft, damp cloth.
• Do not use soaps, polishes, or solvents.
Below are common products to avoid using around sensors.
Cleaners and Lubricants
• Brake cleaners
• Lubricants
• Rust inhibitors
• Window and glass cleaners
• Dishsoaps
• Citrus based cleaners
• Alcohol based cleaners
• Hand sanitizers
• Anionic detergents
• Methanol (fuels and antifreezes)
Silicones
• Silicone cleaners and protectants
• Silicone based adhesives, sealants, and gels
• Hand/body and medicinal creams containing silicone
• Tissues containing silicone
• Mold releasing agents
• Polishes
Aerosols
• Bug repellents and sprays
• Lubricants
• Rust inhibitors
• Window cleaners
Page 9
GasAlertMicroClip
Operator’s Manual
10
Calibration
Procedure Display Procedure Display
a
Caution
Calibrate only in a safe area that is free of hazardous gas in an atmosphere of 20.9% oxygen.
1. Press and hold C as the detector
performs the OFF countdown. Continue holding C when the LCD briefly
deactivates.
4. When is displayed and
flashes, connect the gas cylinder (refer to page 11) and apply gas at a flow rate of 250 to 500 ml/min.
After a sufficient amount of gas has been detected (approximately 30 seconds), the
detector beeps and flashes while the detector completes the
calibration.
2. The LCD then activates again and
performs the CAL countdown. Continue holding C until the countdown is complete
to enter calibration.
5. The LCD displays CAL DUE. Next, a
screen displays showing the number of days remaining before calibration is due for each sensor. The LCD then displays the earliest calibration due date, as some sensors require more frequent calibrations.
3. flashes while the detector zeroes all of the sensors and calibrates the oxygen sensor. If a sensor fails to auto zero, it cannot be calibrated. When auto zero is complete, the LCD displays APPLY
GAS.
Note Only use the calibration cap during the calibration
span process and for bump tests. Wind currents may cause false readings and poor calibrations. Do not calibrate the detector during or immediately after
charging is complete.
Page 10
GasAlertMicroClip
Attach the Gas Cylinder to the Detector
11
Attach the Gas Cylinder to the Detector
Page 11
GasAlertMicroClip
Operator’s Manual
12
Bump Test
Gas Cylinder Connection
1. Connect the calibration hose to the 0.5 l/min regulator on the gas cylinder. For use with the MicroDock II, use a demand flow regulator.
NOTE: Cylinders that are used with a demand flow regulator must meet the following maximum inlet pressure specifications:
- Disposable cylinders 0-1000 psig/70 bar
- Refillable cylinders 0-3000 psig/207 bar
To perform an automated bump check, refer to the MicroDock II User Manual.
2. Connect the calibration hose to the calibration cap.
3. Attach the calibration cap to the detector.
4. Apply gas. Verify the visual and audible alarms activate.
5. Close the regulator and remove the calibration cap from the detector. NOTE: The detector will temporarily remain in alarm until the gas clears from the sensors.
6. Disconnect the hose from the calibration cap and the regulator.
Gas Cylinder Guidelines (Bump Test)
Ɣ To ensure an accurate bump check, use a premium-grade gas. Use gases
approved by the National Institute of Standards and Technology.
Ɣ Do not use a gas cylinder that is past its expiration date.
Note
Only use the calibration cap during calibration and bump check.
Page 12
GasAlertMicroClip
Alarms
13
Alarms
Refer to the following table for information about alarms and corresponding screens. If Stealth mode is enabled, the audible and
visual alarms are disabled. Only the vibrator alarm activates.
Alarm Display Alarm Display
Low Alarm
• Slow siren
• Slow alternating flash
L and gas bar flash
• Vibrator alarm activates
TWA Alarm
• Slow siren
• Slow alternating flash
L and gas bar flash
• Vibrator alarm activates
High Alarm
• Fast siren
• Fast alternating flash
L and gas bar flash
• Vibrator alarm activates
STEL Alarm
•Fast siren
• Fast alternating flash
L and gas bar flash
• Vibrator alarm activates
Multi-Gas Alarm
• Alternating low and high alarm siren and flash
L and gas bars flash
• Vibrator alarm activates
Over Limit (OL) Alarm
• Fast siren and alternating flash
L and gas bar flash
• Vibrator alarm activates
OL displays
Page 13
GasAlertMicroClip
Operator’s Manual
14
Alarm Display Alarm Display
Sensor Alarm
During startup Error [sensor name]
displays
• During normal operation Err displays
Confidence Beep and IntelliFlash
• One beep and flash every second
Note: Confidence Beep and IntelliFlash automatically deactivate during low battery alarm, self-test fail, calibration fail, bump test fail, or an alarm event.
Low Battery Alarm
• Sequence of 10 rapid sirens and alternating flashes with 7 seconds of silence in between (continues for 15 minutes)
and
L
flash,
LOW BAT
displays, and the vibrator alarm activates
• After 15 minutes of the Low Battery alarm, the Automatic Shutdown Alarm sequence begins
OFF displays before deactivating
Automatic Shutdown Alarm
• Sequence of 10 rapid sirens and alternating flashes with 1 second of silence in between (sequence reactivates seven times)
LOW BAT and L display, and vibrator alarm activates
OFF displays before deactivating
Note: Alarms can be set to latchin g o r no n- latch ing. To enable /disab le
atching, select/deselect Latching Alarms in Fleet M an age r II. Loca l
regulations may require a latching alarm. If Low Alarm Acknowledge is enabled and a low alarm occurs, press
C to disable the audi bl e al arm . The vi sua l an d vi b ra tor alarms remain activated. If the alarm escalates to a h i gh, STE L, o r TWA alarm, the audible alarm reactivates.
Page 14
GasAlertMicroClip
User Options Menu
15
User Options Menu
To modify the user options, connect the detector to the R Link
adapter and open Fleet Manager II. Refer to the Fleet Manager II Operator s Manual for complete instructions.
The following are the available user options:
1. Sensors (H
2
S, CO, LEL, and O2)
Sensor Disabled Disables the sensor.
Calibration Gas (ppm) / (%LEL) / (%O2) Defines the
calibration gas concentration for each sensor.
Calibration Interval (days) Defines how often a
calibration should be performed.
Bump Interval (days) Defines how often a bump test
should be performed.
Low Alarm (ppm) / (%LEL) / (%O2) Defines the low
alarm setpoint.
High Alarm (ppm) / (%LEL) / (%O2) Defines the high
alarm setpoint.
TWA Alarm (ppm) Defines the time-weighted average
(TWA) alarm setpoint. H
2
S and CO sensors only.
STEL Alarm (ppm) Defines the short-term exposure limit
(STEL) alarm setpoint. H
2
S and CO sensors only.
STEL Interval (minutes) Defines the short-term
exposure limit (5-15 minutes). H
2
S and CO sensors only.
Auto-Zero Startup When enabled, the detector
automatically zeros the H
2
S, CO, and LEL sensors during
the startup self-test.
LEL By Volume CH4 When enabled, the LEL reading is
displayed as %vol., assuming a methane environment.
O2 Auto-Calibration on Startup When enabled, the O
2
sensor is automatically calibrated during startup.
2. User Options
Confidence Beep When enabled, the detector beeps
once every second to verify the battery has sufficient power to detect hazardous gas and emit an alarm. Detector is shipped with Confidence Beep disabled.
Latching Alarms When enabled, the audible, visual, and
vibrator alarms persist during a high or low alarm until the gas concentration is below the low alarm setpoint and has been acknowledged by pressing C.
Safe Mode When enabled, SAFE continuously displays
on the LCD when all gas concentrations are normal or below the alarm setpoints.
Stealth Mode When enabled, the audible alarm, LEDs
and backlight are disabled. displays on the LCD.
Low Alarm Acknowledge When enabled, the audible
alarm can be disabled during a low alarm. The vibrator, LEDs, and LCD remain enabled. For H
2
S, CO, and LEL
sensors only.
Datalog Interval (seconds) Enter a value (1-120 seconds).
Page 15
GasAlertMicroClip
Operator’s Manual
16
Force Calibration When Overdue When enabled, the
detector automatically enters calibration during startup for overdue sensors. If the sensors are not calibrated immediately, the detector will deactivate.
Cal Lock When enabled, the sensors can only be
calibrated using an IR device (IR Link with Fleet Manager II or the MicroDock II base station).
Force Bump When Overdue When enabled, a bump test
is required if the sensor has exceeded its bump test interval. If a successful bump test is not performed, the detector will deactivate.
IntelliFlash When enabled, the green LED flashes to
provide continuous visual confirmation that the detector is operating correctly.
IntelliFlash automatically deactivates during a low battery alarm, a self-test fail, a calibration fail, a bump test fail, or during an alarm event. To define how often
IntelliFlash occurs (1-60 seconds), refer to Confidence
Beep and IntelliFlash Interval. Default setting is 1 second. Detector is shipped with IntelliFlash enabled.
Confidence Beep and IntelliFlash Interval Enter a value (1-60 seconds) to define how often IntelliFlash
occurs and the detector beeps. Intelliflash and/or Confidence Beep must be enabled in order to define Confidence Beep and IntelliFlash Interval.
Language Select the language to display on the LCD: English, Français (French), Deutsch (German), Español (Spanish), or Português (Portuguese).
Charging the Rechargeable Battery
a Warning
Only the manufacturer can replace the rechargeable battery. Failure to adhere to this caution can lead to fire and/or explosion.
Charge only in a safe area that is free of hazardous gas and within temperatures of 0°C to 45°C (32°F to 113°F).
The charging adapter is specific to your region. Use of the charging adapter outside your region will damage the charger and the detector.
Do not calibrate during or immediately after charging.
a
Avertissement
Seul le fabricant est habilité à remplacer la rechargeable batterie. Le non-respect de cette consigne peut provoquer un incendie et/ou une explosion.
Chargez le détecteur uniquement dans une zone sûre ne renfermant pas de gaz dangereux et dont la température ambiante reste comprise entre 0 à 45 °C (32 à 113 °F).
To charge the battery:
1. Deactivate the detector. Insert the charging adapter plug into an AC outlet.
Page 16
GasAlertMicroClip
Maintenance
17
2. Connect the charging adapter to the detector IR interface.
3. Charge the battery.
4. Charge the battery after each workday.
Maintenance
To maintain the detector in good operating condition, perform the following basic maintenance as required.
• Calibrate, bump test, and inspect the detector on a regular schedule.
• Maintain an operations log of all maintenance, bump tests, calibrations, and alarm events.
• Clean the exterior with a soft damp cloth. Do not use solvents, soaps, or polishes.
Replacing a Sensor or Sensor Filter
a Warning
To avoid personal injury, use only sensors specifically designed for the detector.
Use proper ESD handling practices.
a
Caution
Ensure hands are clean or wear gloves before handling components.
To replace a sensor or sensor filter, refer to the following illustration, table, and procedures.
Item Description
1 Detector
2 IR and charger interface
3 Charging adapter
4 USB Cable
3
2
1
4
Page 17
GasAlertMicroClip
Operator’s Manual
18
1. Deactivate the detector. On a clean surface, place the
detector face down.
2. Remove the six machine screws from the rear shell.
Remove the back cover by lifting the top and the bottom upwards simultaneously to prevent damaging the charging pins.
Replacing the sensor filter
1. Note the placement of the PCB to ensure it is
replaced correctly. Remove the two screws on the PCB. Remove the PCB carefully.
a
Caution
Ensure no damage occurs to the battery.
2. Remove the old sensor filter. t may be stuck to the
sensors.
3. Place the new sensor filter.
Note
When inserting a new sensor filter, ensure the black gasket is facing the front shell.
4. To complete the detector, refer to Reassembling the
detector.
Item Description Item Description Item Description
1 Front shell 5 Rear shell 9 H
2
S sensor
2 LEL sensor 6 Machine screws (6) 10 O
2
sensor
3 PCB 7 Sealing rib 11 Sensor filter
4 PCB screws (2) 8 CO sensor
1
11
10
3
2
4
6
5
8
9
7
Page 18
GasAlertMicroClip
Maintenance
19
Replacing H2S, CO, and LEL sensor
1. Note the placement of the PCB to ensure it is replaced correctly. Remove the two screws on the PCB. Remove the PCB carefully.
a
Caution
Ensure no damage occurs to the battery.
a) If the sensor filter is stuck to the sensors,
remove and replace the sensor filter into the front shell.
2. Slide the sensors out.
Note
Detectors that are configured for 1, 2, or 3 gases may contain a dummy sensor in one of the four sensor locations.
3. Insert the new sensor(s).
To complete the detector, refer to Reassembling the
detector.Replacing the oxygen sensor
Note Detectors that are configured for 1, 2, or 3 gases may
contain a dummy sensor in one of the four sensor locations.
Metal sensor posts
Plastic sensor post
Flex cable
Oxygen sensor
R gidified flex PCB
Page 19
GasAlertMicroClip
Operator’s Manual
20
1. Gently remove the circular rigidified flex PCB atop the sensor from the metal sensor posts. Take care not to tear the flex cable.
2. Note the placement of the PCB to ensure it is replaced correctly. Remove the two screws on the PCB.
a
Caution
Ensure no damage occurs to the battery.
3. Lift the PCB straight up. The oxygen sensor will stay in the front shell. Remove the sensor.
4. On roughly the same spot on the front shell, place the new sensor. Lower the PCB over the oxygen sensor.
5. Ensure the plastic sensor post is inserted into the clear plastic hole. Carefully replace the circular rigidified flex PCB atop the metal sensor posts. Take care not to tear the flex cable.
6. Press down to secure the circular rigidified flex PCB atop the metal sensor posts.
7. To complete the detector, refer to Reassembling the detector.
Reassembling the detector
• Verify the PCB is seated correctly and inserted exactly as it was removed (sensors face the front shell). Replace the two PCB screws.
• Visually inspect the battery to ensure no damage has occurred.
• When replacing the rear shell, ensure the charging pins (bottom of inside rear shell) are aligned with the corresponding holes on the PCB.
• Press the front and rear shells together firmly to ensure a proper seal. Ensure the front and rear shell have a uniform, tight 1/16 in. (1 mm) seal on all sides of the detector.
• When replacing the screws, they must be seated properly to prevent cross threading. Turn the screw counter­clockwise until a click is heard and then begin tightening the screw clockwise.
• New sensor(s) should be calibrated. Activate the detector and calibrate the sensor(s). Refer to Calibration
.
Note
Ensure the rib on the interior rear shell inserts between the battery and the PCB . Refer to the following illustrations.
1
2
Page 20
GasAlertMicroClip
Specifications
21
XT Model
XL Model
Specifications
Instrument dimensions XT 11.25 x 6 00 x 2.89 cm (4.4 x 2.4 x 1.1 in.)
XL 11.25 x 6.00 x 3.22 cm (4.4 x 2.4 x 1 2 in.) Weight
XT 170 g (6.0 oz.) XL 190 g (6.7 oz.)
Operating temperature -20°C to +50°C (-4°F to +122°F),
+50°C to +58°C is certified by CSA International on the combustible sensor with ±5% accuracy
Storage temperature -40°C to +50°C (-40°F to +122°F) Operating humidity 0% to 95% relative humidity
(non-condensing)
Alarm setpoints May vary by region and are user defined. All
setpoints automatically display during the startup self-test.
Detection range
H
2
S: 0 - 100 ppm (1 / 0.1 ppm increments)
CO: 0 - 500 ppm (1 ppm increments) O
2
: 0 - 30.0% vol. (0.1% vol. increments)
Combustible (LEL): 0 - 100% (1% LEL increments) or 0 - 5.0% v/v methane
2
1
2
1
Page 21
GasAlertMicroClip
Operator’s Manual
22
Sensor type
H
2
S, CO, O2: Single plug-in electrochemical cell
Combustibles: Plug-in catalytic bead
O
2
measuring principle Capillary controlled concentration
sensor
Alarm conditions TWA alarm, STEL alarm, low alarm, high
alarm, multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence beep, automatic shutdown alarm
Audible alarm 95 dB at 30 cm (1 ft.) (100 dB typical) variable
pulsed beeper
Visual alarm Red light-emitting diodes (LED) Display Alphanumeric liquid crystal display (LCD) Backlight Activates for 5 seconds when the pushbutton is
pressed and during an alarm condition
Self-test Initiated during activation Calibration Automatic zero and automatic span Oxygen sensor Automatic span on activation (enable/disable) User field options Startup message, confidence beep,
latching alarms, enable/disable safe display mode, oxygen measurement, combustible sensor measurement, sensor disable, define calibration interval, force calibration, calibration lock, force bump, define bump interval, bump due lock, stealth mode, language selection, enable/disable automatic oxygen calibration, enable/disable auto zero at startup, define alarm
setpoints, define span concentration values, define STEL calculation period, low alarm acknowledge, IntelliFlash, confidence beep, and IntelliFlash interval
Battery Operating Time
XL XT
Typical Battery Life*
18 hours
Recharges in less than 6 hours
10 hours
Recharges in less than 4 hours
Cold Weather Battery Life**
After 2 years:
12 hours at -4°F / ­20°C
*Approximately 20% capacity loss is normal wi h lithium polymer batteries after 500 charge cycles. Refer to the Operator’s Manual for additional information.
**Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of ­4°F / -20°C to 122°F/50°C.
Page 22
GasAlertMicroClip
Specifications
23
Year of manufacture The detector's year of manufacture is
determined from the serial number. The second and third number after the first letter determines the year of manufacture.
E.g., KA410-001000 = 2010 year of manufacture
Approved batteries
Approved batteries for GasAlertMicroClip XT: Narada NL 503759
Approved batteries for GasAlertMicroClip XL: Narada NLP883759LT20
Rechargeable battery Temperature code
Lithium polymer -20°C Ta +50°C T4
Battery charger GasAlertMicroClip charging adapter
a
Warning
Charge only in a safe area that is free of hazardous gas and within temperatures of 0°C to 45°C (32°F to 113°F).
First-time charge XT 2-3 hours XL 5-6 hours
Normal charge XT 2-3 hours XL 5-6 hours
Warranty 2 years including sensors Approvals
Approved by CSA to both U.S. and Canadian Standards CAN/CSA C22.2 No. 157 and C22.2 152
ANSI/UL - 913 and ANSI/ISA - 12.13.01 Part 1
CSA Class I, Division 1, Group A, B, C, and D ATEX CE 0539 g II 1 G Ex ia IIC T4 Ga
Sira 13ATEX2330 EN 60079-0, EN 60079-11, and EN 60079-26
IECEx Ex ia IIC T4 Ga IECEx CSA 05.0015
IEC 60079-0, IEC 60079-11, IEC 60079-26
KTL GasAlertMicroClip XT: 12-KB4BO-0053 GasAlertMicroClip XL: 14-KB4BO-0659X
Page 23
GasAlertMicroClip
Operator’s Manual
24
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 Canadian EMI requirements. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.