Bushnell DIGITAL NAVIGATION 70-0102 User Manual

Instruction Manual Manuel D'Instructions Manual de Instrucciones Bedienungsanleitung Manuale di Istruzioni Manual de Instruções
Model #: 70-0102
Lit #: 98-0212/06-03
Brújula Digital de Lujo • Deluxe Digital Compass
Bussola Digitale di Lusso • Bússola Digital de Luxo
1
ENGLISH................................................... 2-17
FRANÇAIS.................................................. 18-33
ESPAÑOL....................................................34-49
DEUTSCH.................................................. 50-65
ITALIANO.................................................. 66-81
PORTUGUÊS............................................. 82-97
32
Congratulations on your purchase of a BUSHNELL®DNS Pro wrist top compass. It is a precision instrument constructed of the finest materials and assembled by highly skilled craftsmen for a lifetime of trouble-free use under the most demanding conditions. This booklet will help you achieve optimum performance by explaining how to use its various features.
WHAT THE BUTTONS MEAN
(1) ADJ Adjusts your settings.
(2) MODE Changes display from one feature to the next within the
time or compass modes.
(3) ALTI Accesses ALTIMETER function from Time Function.
(4) LIGHT Turns map light on.
(5) COMP/+ Switches from Time Mode to Compass Mode.
Also increases adjustment settings.
(6) BARO/- Accesses BAROMETER and WEATHER
FORECASTING feature from TIME Mode. Also decreases settings while in adjustment modes.
LCD Display
(1)
(3)
(4)
(6)
(5)
Compass Level
ENGLISH
(2)
New Settings
ALARM
Alarm Setting Mode
Press MODE button until Alarm Mode is displayed. The alarm consists of 5 alarms, 3 for Time 1 for Altitude, and 1 for Temperature. Press
COMP/+ or BARO/- button to scroll through
the different alarms. Press and hold down
ADJ for 3 seconds until
the minute blinks, press
COMP/+ or BARO/- button to adjust to
desired values. Press
MODE button for next setting. Press ADJ
button at any time to save changes and exit. The alarm is activated automatically after adjustments have been made. To stop the alarm from beeping, press any button.
The alarm can also be turned on or off by going to the relevant alarm and pressing the
ALTI button to activate alarm function, press again
to activate Snooze function, and press again to de-activate alarm.
Temperature Alarm
Sets the alarm to sound when the temperature measurement reaches the programmed level. In the Alarm Mode, the Temperature alarm uses the same measurement units (ºC or F) that were last set in the Temperature Mode. To change this you must first change the temperature units in the Barometer Mode. Pressing the
COMP/+ or
BARO/- once changes the temperature in tenths of a degree.
Holding the button down changes the temperature in increments of 1 degree.
SETTING THE TIME
Default Time Mode / Time Settings
Press MODE button until Time Mode is displayed. Press and hold down ADJ for 3 seconds. Press COMP/+ or BARO/- button until desired value appears, and then press MODE button for next
setting. Press
ADJ button at any time to save changes and exit. When this is done, seconds will
be reset to 00. A small "A" or "P" will be to the lower left of the hours to denote AM or PM.
Date Settings
When setting the date, the year is also displayed. Press MODE button until Time Mode is displayed. Press and hold down ADJ for 3 seconds. Press
MODE button and scroll to desired setting to
change. Press
COMP/+ or BARO/- button until desired value
appears, and then press
MODE button for next setting. Press ADJ
button at any time to save changes and exit.
For 24/12 hour setting press
MODE button until Time Mode is
displayed. Press and hold down
ADJ for 3 seconds. Press MODE
button and scroll through settings until 24/12 hour setting appears, then press
COMP/+ or BARO/- button to enter desired setting.
Press
ADJ button at any time to save changes and exit.
5
4
COUNTDOWN TIMER ALARM
Countdown / Reverse-Timer Mode
Press MODE button until Countdown Timer Mode is displayed, represented by ‘RT’ (reverse timer). To operate press
COMP/+
button to start and press again to stop, then press BARO/- button to reset the Countdown Timer.
To set the Countdown Timer press and hold down
ADJ button for
3 seconds, which will cause the seconds setting to blink. Adjust with the
COMP/+ or BARO/- button, and then press MODE button to
adjust next setting. Press
ADJ button to save settings and exit. Press
ALTI for AUTO to allow Countdown Timer to repeat function
automatically, and press
ALTI again to turn off ‘AUTO function.
Press any button when alarm sounds to stop the Countdown Timer. If nothing is pressed the Countdown Timer will stop beeping after 10 seconds, but the countdown timer will continue if the ‘AUTO function is on. To stop the Countdown Timer if the ‘AUTO’ function is on, you must go to the Countdown Timer Mode and press
COMP/+ to turn off the AUTO function and then press
ALTI button to stop it.
DIGITAL COMPASS
Compass Mode
Press MODE button until Time Mode is displayed, and then press COMP/+ button. If already in Time Mode, simply press COMP/+
button and Compass Mode is displayed. Hold the compass level using the bubble level to get a reading. If the Cardinal Points blink then the compass may need to be calibrated. (See trouble shooting tips.)
Compass Calibration
In Compass Mode, hold down ADJ button for 3 seconds. Calibration Mode is displayed. Put the compass on a level, non­magnetic surface and press the
COMP/+ button. The word CAL
will start blinking. Then, rotate the compass 2 full circles slowly WHILE HOLDING THE COMPASS LEVEL. Each revolution should take about 10 seconds. When done, press
COMP/+ again.
When completed, the display shows DONE and it will then go
Altitude Alarm
Sets the alarm to sound when the altitude reaches the programmed level. In the Alarm Mode, the Altitude alarm uses the same measurement units that were last set in the Altimeter Mode. To change this you must first change it in the Altimeter Mode. To adjust the altitude at which the alarm will go off, press
ADJ to enter the
setting mode. Press
COMP/+ or BARO/- to change the altitude
alarm setting. Press
ADJ to save and exit.
Beep Function
In the Alarm Mode a Beep function is also available. When activated, the Beep function causes a beep sound to be made whenever a button is depressed, even when the Alarm function is turned off. To activate the function go to the Beep function in the Alarm Mode, press the
ALTI button and ‘ON is displayed. Press
again and OFF is displayed.
Stopwatch Mode
Press MODE button until Stop Watch Mode is displayed. To operate, press
COMP/+ button to start and press again to stop.
Pressing
BARO/- button will reset the Stop Watch.
Stop Watch Mode / Split Timing Function
For split timing function, press the BARO/- button while the Stop Watch is operating in order to stop the display and press again to continue. The display will show your time down to 1/100th of a second. You can also press the
BARO/- button while the Stop
Watch is operating to stop the display and then press the
COMP/+
button to stop the Stop Watch and display the final reading. Press the
BARO/- button again to reset the Stop Watch. Split timing
function is displayed as SPL’ when activated and the display returns to normal when
BARO/- button is pressed.
7
6
To conserve energy, the display in the Homing Mode will show 3 bars instead of the current bearing, and the segments will not be displayed after 1minute. To activate the display again you must press COMP/+. To exit the Homing Mode press MODE again to return to default Compass Mode or
MODE to return to Time Mode.
AUTO BACK LIGHT
Press the LIGHT button to turn on LCD backlight for 5 seconds.
Night Mode
Night Mode allows the backlight to come on automatically when any of the function keys are pressed except when the compass is in Compass Mode. Press and hold down
LIGHT button for 3 seconds,
and the Night Mode icon (represented by the light symbol) appears. To turn off, press and hold down
LIGHT button until the light
symbol disappears.
BATTERY INDICATOR
Low Battery Indicator
A blinking battery icon will appear when the battery is low. The battery compartment is on the back of the compass. Replace used battery with a CR2430 lithium battery.
BAROMETER AND TEMPERATURE
Barometer Mode
Barometric pressure in hPa(mb) and temperature in degrees °F with weather forecast graphic.
To enter the Barometer Mode press MODE
button until Time Mode is displayed, then press BARO/- button. If in Time Mode, Compass Mode or Altimeter Mode then just press BARO/- button and Barometer Mode is displayed. On entering the Barometer Mode, a barometric graph is displayed graphically on the dot matrix display.
automatically into Declination Setting Mode. If Calibration is unsuccessful, the Cardinal Points will blink and you will have to repeat the previous 4 steps again. To skip setting the declination, press the
ADJ button to return to the Compass Mode.
Declination Setting
Declination adjusts the compass for the local magnetic fields. In some areas, magnetic declination can be considerable, so it is a good idea to check for declination on your map or on the Internet. To adjust the compass declination angle, go to Compass Mode and hold down
ADJ button for 3 seconds, and the Compass Homing
Calibration Mode is displayed. Press
MODE button until you get
into Declination Setting Mode displayed as DEC’. Press
COMP/+
or BARO/- button for desired value then press ADJ button to save settings and exit the mode. Declination is sometimes measured as degrees positive and negative. Degrees East are considered positive and Degrees West are considered negative. For example, to change from 3 degrees East (positive) declination to 3 degrees West (negative) press the
BARO/- button
until 3W appears.
Self Homing Mode
Allows you to preset a reference bearing which tells the Compass to alert you to the direction you should be heading. Go into Compass Mode and press
COMP/+ button to display compass homing. To
adjust homing bearing, press and hold
ADJ button for three
seconds. Press
COMP/+ button or BARO/- button to adjust to
desired bearing setting. Pressing
COMP/+ or BARO/- will increase
or decrease bearing by increments of ten. A single push of
COMP/+
or BARO/- moves bearing by 1 degree. When done, press ADJ to return to Homing Mode. To return to Compass Mode press COMP/+ button.
To operate the compass in Homing Mode go into the Compass Mode first, then press the COMP/+ button again to get into Homing Mode.
The main reading displays the actual bearing and the lower reading shows the home bearing. The segments on the circumference show the difference between the two bearings, which can be used to redirect you to stay on course.
9
8
11
Weather Forecast Mode
To change to the Weather Forecast Mode, press the BARO/- button and the weather forecast is displayed. Press
BARO/- button again to
change it back to a barometric graph display. For a full explanation of how the weather forecasting mode works, please see the appendix.
Weather Forecasting Icons
Sunny Partly Cloudy Cloudy Rain/Snow
Barometer and Temperature Units
Barometric pressure in Hg and temperature in °C. To change the type of units of measurement used, press and hold down the
ALTI button
for 3 seconds until the temperature unit blinks and press
COMP/+
or BARO/- button to change it. Then press MODE to go to pressure unit and press
COMP/+ or BARO/- button to change it.
Press
ADJ button at any time to exit. To get an accurate reading of
temperature, please keep in mind that the unit needs to be kept away from source of heat for about 15 minutes (i.e. the temperature will reflect the temperature in your pocket instead of outside if the unit is kept in your pocket.)
Sampling
Barometric pressure and temperature measurements are taken every time you enter the Barometer Mode or when you press the
BARO/- button when you are in this mode. After that, temperature
measurements are taken every 5 seconds for the first 3 minutes, and then it is taken every 5 minutes thereafter.
The barometer automatically takes measurements on the start of every hour even when you are not in the Barometer Mode, except when in the Altimeter Mode where no barometric measurements are taken. The temperature is displayed in resolution of 0.1°C (or 0.2°F). 4 'bars' are displayed when the temperature falls outside the range of -10°C to 60°C (14.0°F to 140°F). Normal reading returns when the temperature value returns to within the set range.
10
Barometric Graph
The barometric pressure graph shows the barometric readings for the past 13 hours. The newest reading is shown as a flashing point on the right side of the graph. The pressure graph readings are relative to the newest measurement point, one dot above the newest point is plus 1 hPa(mb)/0.05 inHg, or if below then it is minus 1 hPa(mb)/0.05 inHg.
Clearing Previous Barometric Readings
Sometimes you need to clear all the previous barometric readings, e.g. when you are in a different country. To clear previous information press
MODE button until Time Mode is displayed,
then press
BARO/- button. If already in Time Mode then just press
BARO/- button and Barometer Mode is displayed. Press and hold
down
ADJ button for 3 seconds, the display blinks and 'CLR ALL'
is displayed, then press
COMP/+ button to confirm that you want
to clear all the previous barometric readings, and the display will then return to Barometer Mode automatically. Press
ADJ button to
exit and return to Barometer Mode if you do not want to clear the previous readings.
Barometric pressure is displayed in units of 1 hPa(mb) (or 0.05 inHg). 4 'bars' are displayed when the barometric pressure falls outside the range of 260 hPa(mb) to 1100 hPa(mb) (or 7.65 inHg to
32.45 inHg). Normal reading returns when the barometric value returns to within the set range.
Altimeter Mode
Press MODE button until Time Mode is displayed, then press ALTI button. If already in Time Mode, Compass Mode or
Barometer Mode, then just press
ALTI button and the Altimeter
Mode is displayed. Press
ALTI button and hold down for
3 seconds to change Altimeter setting from Feet to Meters or vice versa.
Altitude is displayed in resolution of 5 meters (10 feet). The measuring range is – 700 to 8940 meters (-2,300 to 29320 feet) 4 'bars' are displayed when the value exceeds this range. The measured altitude may be a negative value in cases where there is a reference altitude value set or because of certain conditions.
is also stored), and the display is returned to Altimeter Mode. If you decide you do not want to store anything when you have entered the memories, you will have to press
MODE button or ADJ button
which will return you to the Altimeter Mode.
'Full' is displayed when all 10 memories are used up. The memory will need to be reset before you can store new entries.
Reading Stored Memories
To read stored memories press and hold down MODE button for 3 seconds once while in the Altimeter Mode, a memory number is displayed with 3 bars meaning it is empty, or the last viewed memory is shown. If memory is full, 'FULL' is displayed. Press
COMP/+ button and the
last viewed memory is displayed. To view other stored memories press
COMP/+ button again to
scroll through all stored memories.
Clearing Memory
To clear a memory press and hold down MODE button for 3 seconds while in the Altimeter Mode. The last viewed memory is displayed, or if memories is full 'FULL' is displayed. Press
COMP/+
button until the memory you want to clear is displayed, then press BARO/- button, a blinking ‘CLR' is displayed, press BARO/- button again to confirm. To exit press MODE or ADJ button.
To clear all memory press and hold down
MODE button for
3 seconds while in the Altimeter Mode, the last viewed memory is displayed, or if memories are full 'FULL' is displayed. Press COMP/+ button to view memories. Then press BARO/- button and hold down until 'CLR ALL' is displayed. Press
BARO/- button
again to confirm or press
MODE button or ADJ button to exit, or
press
COMP/+ button to continue viewing the memory.
INSTALLING A BATTERY
To open the battery compartment cover, insert a coin in the coin slot and rotate cover in a clockwise direction until it lifts open. Insert the lithium cell (battery type: CR2430) into the compartment, making sure that the negative polarity faces downwards. Close battery compartment cover until it clicks shut.
13
The Altitude graph consists of 14 columns and 9 rows of dots with each column of dots representing a period when the altitude measurements were taken, with each dot representing a unit of 10 meters (30 feet).
The graph takes an altitude reading every 5 seconds for the first 3 minutes and then every 5 minutes thereafter.
Setting a Reference Altitude
The altimeter uses the built in ISA (International Standard Atmosphere) values to convert the air pressure measured at the current location to the equivalent altitude. But you can set a reference altitude and the compass automatically adjusts its air pressure to altitude conversion calculation accordingly.
To set a reference altitude, press and hold down
ADJ button for
3 seconds while in the Altimeter Mode. The reading displays 'OFF' or the current reference value (if set) will blink, which indicates the setting screen, if setting is 'OFF' press
ALTI button. Press COMP/+
button to increase the value in increments of 5 meters (10 feet) or press
BARO/- button to decrease it. When in feet, holding down COMP/+ or BARO/- shifts the
altitude by 100 ft increments. When in meters, it shifts the altitude by 10 meter increments. Pressing
ALTI button turns the value to 'OFF', repeating the procedure returns the display to the
set reference value. Setting the reference altitude to 'OFF' means that the air pressure to altitude conversion based on factory preset data is used only. Pressing
ADJ button at any time will exit the
setting mode.
Memory Function
There are 10 memories where you can store altitude, time and date information. To store current altitude measurement, time and date, press
MODE button and hold down for 3 seconds. While in the
Altimeter Mode, a memory number is displayed with 3 bars meaning it is empty or the last viewed memory is shown. Press COMP/+ button until an empty memory is located. If the memory is full, 'FULL' is displayed (then nothing can be stored until memory is made available). Press and hold down
COMP/+ button
for 3 and the displayed values are stored into the memory (the date
12
32
APPENDIX: HOW THE WEATHER FORECASTER WORKS
Your barometer is a tool to that measures how heavy the air is. The trend is more important for forecasting than the absolute amount of pressure. Generally speaking, a rising barometer means that the air is becoming more stable (and nicer) and a falling barometer means the air is becoming less stable (stormier). Your unit is designed to forecast the weather 12 to 24 hours from now.
Weather Forecast
The weather forecast for the next 12-24 hours is calculated from absolute pressure once the unit is powered up.
Absolute Pressure / mbar Weather Condition
P < 970 Rainy 970 < P <1000 Cloudy 1000 < P < 1030 Partly Cloudy P >1030 Sunny
Your DNS Pro takes barometric pressure every hour and compares current pressure with the previous one to trace the change. If pressure keeps rising or falling for more than 3 hours, weather condition will be changed relative to the change in pressure.
The weather forecast is calculated from the change in pressure per time period. The change in weather condition is directly proportional to the speed of change in barometric pressure. A rising slope indicates High Pressure System and a good (stable) weather trend. A falling slope means a Low Pressure System and worsening weather trend (unstable).
Fluctuations in pressure typically due to a sudden change of conditions (ex. rapid change in elevation due to flying from one elevation to another) are filtered out and no weather forecast is made. If this happens, the unit will restart monitoring the pressure for required time period. Barometric pressure that keeps constantly rising or falling during the past 3 hours will effectively change the forecast weather condition.
15
BATTERY LIFE
Your DNS is designed for continuous use and batteries will last over one year with regular usage. Heavy use of the alarms, light, or compass will shorten battery life.
TROUBLE SHOOTING
If the Cardinal points (N, NE, E, SE etc.) on your compass blink – Try holding the compass
LEVEL using the bubble level as a guide. The Cardinal points may also blink when the Compass encounters magnetic interference from the surrounding areas. The Cardinal points blink because the Compass is unable to measure Bearings accurately. If this does not fix the blinking, please recalibrate your compass. Remember to keep the Compass away from metal objects which may cause magnetic interference. Also double check that your declination is properly set (In general, zero degrees should be the default setting).
Three dashes are displayed Your compass has gone into a "sleep" mode to save batteries. Press
COMP/+ to reactivate the compass.
Can’t turn unit off – This unit is designed to be constantly on and the batteries will last about a year assuming normal usage.
The Temperature does not seem accurate – remember that it takes 15 minutes for the unit to adjust to the ambient temperature. Keeping the unit in a pocket or in direct sunlight will impact the temperature.
My weather forecaster shows rain but it is sunny right now– Your weather forecaster is designed to forecast the weather 12-24 hours from the current time.
Reset compass – If, during operation, an external electrodischarge occurs near the compass, the unit may exhibit erroneous readings. To solve this problem, the watch must be reset and recalibrated. The watch is automatically reset when the battery is removed.
If your wristtop goes into a test mode after inserting the battery – you will need to re-install your battery. Remove battery. Wait 10 seconds then carefully re-insert the battery making sure that it is well placed in the battery compartment. Close battery door.
Y
ou will know that your wristtop has gone into test mode – if you see the LCD segments around
the display turning on one-by-one and moving in an counter-clockwise direction. After the test mode is completed, your wristtop will return to normal. The test mode will not harm your wristtop's normal operation.
14
1716
WARRANTY / REPAIR
TWO-YEAR LIMITED WARRANTY
Your Bushnell® product is warranted to be free of defects in materials and workmanship for two years after the date of purchase. In the event of a defect under this warranty, we will, at our option, repair or replace the product, provided that you return the product postage prepaid. This warranty does not cover damages caused by misuse, improper handling, installation, or maintenance provided by someone other than a Bushnell Authorized Service Department.
Any return made under this warranty must be accompanied by the items listed below:
1) A check/money order in the amount of $10.00 to cover the cost of postage and handling
2) Name and address for product return
3) An explanation of the defect
4) Proof of Date Purchased
5) Product should be well packed in a sturdy outside shipping carton, to prevent damage in transit, with return postage prepaid to the address listed below:
IN U.S.A. SEND TO: IN CANADA SEND TO:
Bushnell Performance Optics Bushnell Performance Optics Attn.: Repairs Attn.: Repairs 8500 Marshall Drive 25A East Pearce Street, Unit 1 Lenexa, Kansas 66214 Richmond Hill, Ontario L4B 2M9
For products purchased outside the United States or Canada please contact your local dealer for applicable warranty information. In Europe you may also contact Bushnell at:
BUSHNELL Performance Optics Gmbh European Service Centre MORSESTRASSE 4 D- 50769 KÖLN GERMANY Tél: +49 (0) 221 709 939 3 Fax: +49 (0) 221 709 939 8
This warranty gives you specific legal rights.
You may have other rights which vary from country to country.
©2003 Bushnell Performance Optics
Félicitations et merci de votre achat d'une montre-bracelet navigateur numérique DNS Pro BUSHNELL
®
. C'est un instrument de précision, fabriqué avec les matériaux de la meilleure qualité, assemblé par des artisans hautement spécialisés, pouvant assurer toute une vie de service sans problème, dans les conditions les plus rudes. Ce livret vous permettra d'en obtenir les performances les meilleures car il explique comment utiliser ses diverses fonctions.
R
ÔLE DES BOUTONS
ADJ Ajuste vos réglages.
MODE Fait passer l'affichage d'une fonction à la suivante, à
l'intérieur des modes temps et navigateur.
ALTI Accède à la fonction ALTIMÈTRE depuis la fonction temps.
LIGHT Sert à éclairer l'affichage à cristaux liquides.
COMP/+ Fait passer de Time Mode (mode temps) à Compass Mode
(mode navigateur). Sert aussi à l'augmentation des réglages.
BARO/- Accède aux fonctions BAROMÈTRE et PRÉVISIONS
MÉTÉOROLOGIQUES depuis TIME Mode (mode temps). Sert aussi à la diminution des réglages aux modes de réglage.
18
FRENCH
19
Ecran à Cristaux Liquides
(1)
(3)
(4)
(6)
(5)
(2)
Niveau du Navigateur Numérique
Nouveaux Réglages (New Settings)
ALARME
Mode Réglage Alarme (Alarm Setting Mode)
Appuyez sur le bouton MODE jusqu'à ce que Alarm Mode (mode alarme) soit affiché. Ce mode comprend 5 alarmes, 3 pour le temps, 1 pour l'altitude et 1 pour la température. Appuyez sur le bouton COMP/+ ou BARO/- pour faire défiler les différentes alarmes. Maintenez
ADJ enfoncé pendant 3 secondes jusqu'à ce que le chiffre
de la minute clignote ; appuyez sur
COMP/+ ou BARO/- pour
ajuster les valeurs souhaitées. Appuyez sur le bouton
MODE pour le
réglage suivant. Appuyez sur le bouton
ADJ à n'importe quel
moment pour sauvegarder les changements et sortir. L'alarme s'active automatiquement une fois les réglages effectués. Pour faire taire l'alarme, appuyez sur n'importe quel bouton.
Il est aussi possible d'activer et de désactiver l'alarme en accédant à l'alarme appropriée et en appuyant sur le bouton
ALTI pour activer
la fonction d'alarme, en rappuyant pour activer la fonction de Rappel et en rappuyant pour désactiver l'alarme.
Alarme Température (Temperature Alarm)
Programme le déclenchement de l'alarme quand la température atteint la valeur programmée. Au Alarm Mode (mode alarme), l'alarme de température utilise les unités (ºC ou F) qui ont été programmées en dernier au Temperature Mode (mode température). Pour changer cela, vous devez d'abord changer les unités de température au Barometer Mode (mode baromètre). Une seule pression sur
COMP/+ ou BARO/- change la température par paliers
d'un dixième de degré. Si vous maintenez le bouton enfoncé, la température change par paliers de 1 degré.
21
RÉGLAGE DE L'HEURE
Mode Temps par Défaut / Réglages de l'heure (Default Time Mode/Time Settings)
Appuyez sur le bouton MODE jusqu'à ce que Time Mode (mode temps) soit affiché. Maintenez ADJ enfoncé pendant 3 secondes. Appuyez sur le bouton COMP/+ ou BARO/- jusqu'à ce que la
valeur souhaitée apparaisse puis appuyez sur le bouton
MODE pour le réglage suivant. Appuyez
sur le bouton
ADJ à n'importe quel moment pour sauvegarder les changements et sortir. Cela fait,
les secondes sont remises à 00. Un petit "A" ou "P" apparaît en bas, à gauche des heures pour indiquer AM (avant midi) ou PM (après midi).
Réglages de Date (Date Settings)
Lors du réglage de la date, l'année est aussi affichée. Appuyez sur le bouton
MODE jusqu'à ce que Time Mode (mode temps) soit
affiché. Maintenez
ADJ enfoncé pendant 3 secondes. Appuyez sur le
bouton
MODE et faites défiler jusqu'au réglage à changer. Appuyez
sur le bouton
COMP/+ ou BARO/- jusqu'à ce que la valeur
souhaitée apparaisse puis appuyez sur le bouton
MODE pour le
réglage suivant. Appuyez sur le bouton
ADJ à n'importe quel
moment pour sauvegarder les changements et sortir.
Pour le réglage 24/12 heures, appuyez sur le bouton
MODE jusqu'à
ce que Time Mode (mode temps) soit affiché. Maintenez
ADJ
enfoncé pendant 3 secondes. Appuyez sur le bouton MODE et faites défiler les réglages jusqu'à ce que le réglage 24/12 heures apparaisse puis appuyez sur le bouton
COMP/+ ou BARO/- pour entrer le
réglage souhaité. Appuyez sur le bouton
ADJ à n'importe quel
moment pour sauvegarder les changements et sortir.
20
ALARME DE MINUTERIE DE COMPTE À REBOURS
Mode Compte à Rebours / Minuterie Inverse (Countdown / Reverse-Timer Mode)
Appuyez sur le bouton MODE jusqu'à ce que Countdown Timer Mode (mode minuterie de compte à rebours) soit affiché, représenté par RT ’ (minuterie inverse). Pour l'utiliser, appuyez sur le bouton COMP/+ pour démarrer et appuyez de nouveau pour arrêter ; appuyez sur le bouton
BARO/- pour remettre le compte à rebours à
zéro.
Pour régler la minuterie de compte à rebours, maintenez le bouton ADJ enfoncé pendant 3 secondes, ce qui fait clignoter le réglage des secondes. Ajustez à l'aide du bouton
COMP/+ ou BARO/- puis
appuyez sur le bouton
MODE pour ajuster le réglage suivant.
Appuyez sur le bouton
ADJ pour sauvegarder les réglages et sortir.
Appuyez sur
ALTI pour AUTO afin de permettre la répétition
automatique de la fonction de minuterie de compte à rebours ; appuyez de nouveau sur
ALTI pour désactiver la fonction AUTO.
Lorsque l'alarme retentit, appuyez sur n'importe quel bouton pour arrêter le compte à rebours. Si vous n'appuyez sur aucun bouton, la minuterie cessera de biper au bout de 10 secondes, mais elle continuera si la fonction ‘AUTO est activée. Pour arrêter le compte à rebours si la fonction AUTO est activée, vous devez accéder au Countdown Timer Mode (mode minuterie de compte à rebours) et appuyer sur
COMP/+ pour désactiver la fonction AUTO puis
appuyer sur le bouton
ALTI pour arrêter.
NAVIGATEUR NUMÉRIQUE
Mode Navigateur Numérique (Compass Mode)
Appuyez sur le bouton MODE jusqu'à ce que Time Mode (mode temps) soit affiché puis appuyez sur le bouton
COMP/+. Si vous
êtes déjà au Time Mode (mode temps), appuyez simplement sur le bouton
COMP/+ et Compass Mode (mode navigateur) est affiché.
Maintenez le navigateur horizontal à l'aide du niveau à bulle pour obtenir un relevé. Si les points cardinaux clignotent, il est probablement nécessaire d'étalonner le navigateur numérique. (Voir les conseils de dépannage).
23
Alarme Altitude (Altitude Alarm)
Programme le déclenchement de l'alarme quand l'altitude atteint la valeur programmée. Au mode alarme, l'Altitude Alarm (alarme altitude) utilise les unités de mesure établies en dernier au Altimeter Mode (mode altimètre). Pour changer cela, vous devez d'abord les changer au Altimeter Mode (mode altimètre). Pour régler l'altitude à laquelle l'alarme doit se déclencher, appuyez sur
ADJ pour entrer
au mode de réglage. Appuyez sur
COMP/+ ou BARO/- pour
changer le réglage de l'alarme d'altitude. Appuyez sur
ADJ pour
sauvegarder les réglages et sortir.
Fonction Bip (Beep Function)
Au Alarm mode (mode alarme), la fonction bip est aussi disponible. Lorsqu'elle est activée, la fonction bip fait retentir un bip chaque fois que vous appuyez sur un bouton, même si la fonction alarme est désactivée. Pour activer la fonction, allez à la fonction bip au Alarm Mode (mode alarme), appuyez sur le bouton
ALTI et ON (activé)
est affiché. Appuyez de nouveau et OFF (désactivé) est affiché.
Mode Chronomètre (Stopwatch Mode)
Appuyez sur le bouton MODE jusqu'à ce que Stop Watch Mode (mode chronomètre) soit affiché. Pour le faire fonctionner, appuyez sur le bouton
COMP/+ pour démarrer et appuyez de nouveau pour
arrêter. Appuyez sur le bouton
BARO/- pour remettre le
chronomètre à zéro.
Mode Chronomètre/ Fonction de Chronométrage Fractionné (Split Timing Function/Stop Watch Mode)
Pour la fonction de chronométrage fractionné, appuyez sur le bouton
BARO/- pendant le fonctionnement du chronomètre afin
d'arrêter l'affichage et appuyez de nouveau pour continuer. L'affichage indique le temps jusqu'au centième de seconde. Vous pouvez aussi appuyer sur le bouton
BARO/- pendant le
fonctionnement du chronomètre afin d'arrêter l'affichage puis appuyer sur le bouton
COMP/+ pour arrêter le chronomètre et
afficher le relevé final. Appuyez de nouveau sur le bouton
BARO/-
pour remettre le chronomètre à zéro. La fonction de chronométrage fractionné s'affiche SPL’ quand elle est activée et l'affichage retourne à la normale quand vous appuyez sur le bouton
BARO/-.
22
pour afficher l'autoguidage du navigateur. Pour régler le relèvement d'autoguidage, maintenez le bouton
ADJ enfoncé pendant 3 secondes. Appuyez sur le bouton COMP/+ ou BARO/- pour
entrer le réglage de relèvement approprié. Une pression sur
COMP/+ ou BARO/- augmente ou
diminue la valeur du relèvement par paliers de dix. Une seule poussée sur
COMP/+ ou BARO/-
change le relèvement de 1 degré. Cela fait, appuyez sur ADJ pour retourner au Homing mode (mode autoguidage). Pour retourner au Compass Mode (mode navigateur numérique), appuyez sur le bouton
COMP/+.
Pour utiliser le navigateur numérique au Homing Mode (mode autoguidage), passez d'abord au Compass Mode (mode navigateur) puis rappuyez sur le bouton
COMP/+ pour accéder au mode
autoguidage.
L'affichage principal indique le relèvement présent et l'affichage inférieur indique le relèvement d'autoguidage. Les segments de la circonférence représentent la différence entre les deux relèvements, ce qui vous permet de corriger votre trajectoire.
Pour économiser l'énergie, l'affichage au Homing Mode (mode autoguidage) indiquera 3 « barres » au lieu de la valeur du relèvement présent et les segments disparaîtront au bout d'une minute. Pour réactiver l'affichage, vous devez appuyer sur
COMP/+. Pour sortir
du Homing Mode (mode autoguidage), rappuyez sur
MODE pour
retourner au Compass Mode (mode navigateur) par défaut ou sur
MODE pour retourner au Time Mode (mode temps).
RÉTROÉCLAIRAGE
Appuyez sur le bouton LIGHT pour allumer le rétroéclairage de l'affichage à cristaux liquides pendant 5 secondes.
Mode Nuit (Night Mode)
Night Mode (mode nuit) permet au rétroéclairage de s'allumer automatiquement lorsque l'une des touches de fonctions est actionnée, sauf lorsque le navigateur numérique est au Compass Mode (mode navigateur). Maintenez le bouton
LIGHT enfoncé
pendant 3 secondes ; l'icône Night Mode (mode nuit) (symbole de l'ampoule d'éclairage) apparaît. Pour le désactiver, maintenez le bouton
LIGHT enfoncé jusqu'à ce que le symbole de l'ampoule
d'éclairage disparaisse.
25
Étalonnage du Navigateur Numérique (Compass Calibration)
Au Compass Mode (mode navigateur), maintenez le bouton ADJ enfoncé pendant 3 secondes. Calibration Mode (mode étalonnage) est affiché. Placez le navigateur numérique sur une surface horizontale, non magnétique et appuyez sur le bouton
COMP/+. Le
mot CAL doit commencer à clignoter. Tournez alors le navigateur numérique de 2 tours complets, lentement, TOUT EN LE MAINTENANT HORIZONTAL. Chaque tour doit prendre environ 10 secondes. Cela fait, appuyez de nouveau sur
COMP/+.
Cela terminé, l'affichage indique DONE (FAIT) et il passe automatiquement au Declination Setting Mode (mode de réglage de déclinaison). Si l'étalonnage échoue, les points cardinaux continuent de clignoter et vous devrez répéter les 4 opérations précédentes. Pour sauter le réglage de la déclinaison, appuyez sur le bouton
ADJ pour retourner
au Compass Mode (mode navigateur numérique).
Réglage de Déclinaison (Declination Setting)
La déclinaison règle le navigateur numérique pour les champs magnétiques locaux. Dans certaines régions, la déclinaison magnétique peut être considérable ; il est donc recommandé de vérifier la déclinaison sur votre carte ou sur l'Internet. Pour régler l'angle de déclinaison du navigateur numérique, allez au Compass Mode (mode navigateur numérique) et maintenez le bouton
ADJ
enfoncé pendant 3 secondes ; le Compass Homing Mode (mode autoguidage du navigateur) est affiché. Appuyez sur le bouton MODE jusqu'à ce que vous accédiez au Declination Setting Mode (mode de réglage de déclinaison) affiché ‘DEC. Appuyez sur le bouton
COMP/+ ou BARO/-
pour entrer la valeur appropriée et appuyez sur le bouton ADJ pour sauvegarder les réglages et sortir du mode. La déclinaison est parfois mesurée en degrés positifs et degrés négatifs. Les degrés vers l'est sont considérés positifs et les degrés vers l'ouest sont considérés négatifs. Par exemple, pour passer d'une déclinaison de 3 degrés est (positifs) à une déclinaison de 3 degrés ouest (négatifs), appuyez sur le bouton BARO/- jusqu'à ce que 3W apparaisse.
Mode Autoguidage (Self Homing Mode)
Il vous permet de programmer un relèvement de référence qui indique au navigateur numérique de vous prévenir de la direction vers laquelle vous devez vous diriger. Accédez au Compass Mode (mode navigateur numérique) et appuyez sur le bouton
COMP/+
24
27
INDICATEUR DE PILE
Indicateur de Tension Faible de Pile (Low Battery Indicator)
Une icône clignotante de pile apparaît quand la tension de pile est faible. Le compartiment de pile se trouve à l'arrière du navigateur numérique. Remplacez la pile usée par une pile au lithium CR2430.
BAROMÈTRE ET TEMPÉRATURE
Mode Baromètre (Barometer Mode)
Pression atmosphérique en hPa (mbar) et température en degrés F avec graphique de météo.
Pour entrer au Barometer Mode (mode
baromètre), appuyez sur le bouton
MODE jusqu'à ce que Time Mode
(mode temps) soit affiché puis appuyez sur le bouton
BARO/-.
Si vous êtes au mode temps, au mode navigateur ou au mode altimètre, il vous suffit d'appuyer sur le bouton
BARO/- pour
afficher Barometer Mode (mode baromètre). Lors de l'entrée au mode baromètre, un graphique barométrique apparaît sur l'affichage par matrice de points.
Mode Prévisions Météorologiques (Weather Forecast Mode)
Pour passer au Weather Forecast Mode (mode prévisions météo), appuyez sur le bouton
BARO/- et les prévisions météo apparaissent.
Rappuyez sur le bouton
BARO/- pour revenir au graphique
barométrique. L'explication détaillée du fonctionnement du mode prévisions météo se trouve à l'annexe.
Icônes des Prévisions Météo (Weather Forecasting Icons)
Ensoleillé Partiellement Nuageux Nuageux Pluie/Neige
26
Unités de Pression Atmosphérique et de Température (Barometer and Temperature Units)
Pression atmosphérique en Hg et température en °C. Pour changer le type d'unités de mesure utilisées, maintenez le bouton
ALTI enfoncé
pendant 3 secondes jusqu'à ce que l'unité de température clignote et appuyez sur le bouton
COMP/+ ou BARO/- pour la changer.
Appuyez ensuite sur
MODE pour passer à l'unité de pression et
appuyez sur le bouton
COMP/+ ou BARO/- pour la changer.
Appuyez sur le bouton
ADJ à n'importe quel moment pour sortir.
Pour obtenir un relevé de température exact, n'oubliez pas que l'instrument doit rester éloigné d'une source de chaleur pendant environ 15 minutes (c'est-à-dire qu'il détectera la température de votre poche au lieu de la température extérieure si vous le gardez dans votre poche).
Fréquence des Relevés (Sampling)
Les relevés de pression atmosphérique et de température sont pris chaque fois que vous entrez au Barometer Mode (mode baromètre) ou quand vous appuyez sur le bouton
BARO/- quand vous
êtes dans ce mode. Après cela, les relevés de température sont pris toutes les 5 secondes pendant les 3 premières minutes puis toutes les 5 minutes.
Le baromètre effectue automatiquement les relevés au début de chaque heure, même si vous n'êtes pas au mode baromètre, excepté au mode altimètre où aucun relevé barométrique n'est pris. La température est affichée par paliers de 0,1 °C (ou 0,2 °F). 4 « barres » apparaissent quand la température passe en dehors de la plage de -10 à 60 °C (14,0 à 140 °F). Les relevés normaux réapparaissent quand la température revient dans la plage établie.
Graphique Barométrique (Barometric Graph)
Le graphique de pression atmosphérique indique les relevés barométriques des 13 dernières heures. Le relevé le plus récent est un point clignotant du côté droit du graphique. Les relevés du graphique de pression sont en relation avec le point de relevé le plus récent : un point au-dessus du point le plus récent est plus 1 hPa (mbar)/0,05 in. Hg, ou s'il est en dessous, c'est moins 1 hPa (mbar)/0,05 in. Hg.
Effacement des Relevés Barométriques Précédents (Clearing Previous Barometric Readings)
Il est parfois nécessaire d'effacer tous les relevés barométriques précédents, par exemple, quand vous êtes dans un pays différent. Pour effacer l'information prédente, appuyez sur le bouton
MODE
jusqu'à ce que Time Mode (mode temps) soit affiché puis appuyez sur le bouton BARO/-.
Établissement d'une Altitude de Référence (Setting a Reference Altitude)
L'altimètre utilise les valeurs de l'ISA (International Standard Atmosphere) intégrée pour convertir la pression atmosphérique mesurée à l'emplacement en question à l'altitude équivalente. Mais vous pouvez établir une altitude de référence et le navigateur numérique règlera automatiquement ses calculs de conversion de pression atmosphérique en altitude pour en tenir compte.
Pour établir une altitude de référence, maintenez le bouton
ADJ
enfoncé pendant 3 secondes au Altimeter mode (mode altimètre). L'affichage indique « OFF » (désactivé) ou la valeur de référence (si elle a été établie) clignote, ce qui indique l'écran de réglage ; si le réglage est « OFF », appuyez sur le bouton
ALTI. Appuyez sur le bouton COMP/+ pour
augmenter la valeur par paliers de 5 mètres (10 pieds) ou sur le bouton
BARO/- pour la diminuer.
Lors du réglage en pieds, maintenez
COMP/+ ou BARO/- pour modifier l'altitude par paliers de
100 pieds. Lors du réglage en mètres, l'altitude est modifiée par paliers de 10 mètres. Une pression sur le bouton
ALTI change la valeur à « OFF » ; la répétition de l'opération ramène l'affichage à
la valeur de référence établie. Si l'altitude de référence est sur « OFF », cela signifie que la conversion de la pression atmosphérique en altitude sera basée uniquement sur les données pré­établies en usine. Appuyez sur le bouton
ADJ à n'importe quel moment pour sortir du mode de
réglage.
Fonction de Mémoire (Memory Function)
Il y a 10 mémoires où vous pouvez enregistrer les informations d'altitude, de temps et de date. Pour enregistrer la mesure actuelle d'altitude, d'heure et de date, appuyez sur le bouton
MODE et
maintenez-le enfoncé pendant 3 secondes. Au mode altimètre, un numéro de mémoire est affiché avec 3 « barres » signifiant que la mémoire est vide ou bien la dernière mémoire visualisée est indiquée. Appuyez sur le bouton
COMP/+ jusqu'à ce que vous
trouviez une mémoire vide. Si la mémoire est pleine, « FULL »s'affiche (rien ne peut y être enregistré jusqu'à ce qu'elle soit disponible). Maintenez le bouton COMP/+ enfoncé pendant 3 secondes et les valeurs affichées sont mémorisées (la date est aussi mémorisée) et l'affichage revient au mode altimètre. Si vous décidez de ne rien enregistrer après être entré dans les mémoires, vous devez appuyer sur le bouton
MODE ou ADJ pour retourner
au mode altimètre.
29
Si l'instrument est déjà dans Time Mode (mode temps), appuyez simplement sur le bouton
BARO/- et le Barometer Mode (mode
baromètre) s'affiche. Maintenez le bouton
ADJ enfoncé pendant 3
secondes ; l'affichage clignote et « CLR ALL » (effacer tout) apparaît, puis appuyez sur le bouton
COMP/+ pour confirmer que vous
voulez effacer tous les relevés barométriques précédents ; l'affichage retourne alors automatiquement au mode baromètre. Appuyez sur le bouton
ADJ pour sortir et retourner au mode baromètre si vous ne
souhaitez pas effacer les relevés précédents.
La pression atmosphérique apparaît en unités de 1 hPa (mbar) (ou 0,05 in. Hg). 4 « barres » apparaissent quand la pression atmosphérique passe en dehors de la plage de 260 hPa (mbar) à 1 100 hPa (mbar) (ou 7,65 in. Hg à 32,45 in. Hg). Les relevés normaux réapparaissent quand la pression atmosphérique revient dans la plage établie.
Mode Altimètre (Altimeter Mode)
Appuyez sur le bouton MODE jusqu'à ce que Time Mode (mode temps) soit affiché puis appuyez sur le bouton
ALTI. Si vous êtes déjà
au mode temps, au mode navigateur ou au mode baromètre, il vous suffit d'appuyer sur le bouton
ALTI pour afficher Altimeter Mode
(mode altimètre). Appuyez sur le bouton
ALTI et maintenez-le
pendant 3 secondes pour changer le réglage d'altimètre des pieds aux mètres ou vice versa.
L'altitude est affichée par paliers de 5 mètres (10 pieds). La plage de mesure est de - 700 à 8 940 mètres (- 2 300 à 29 320 pieds). 4 « barres » sont affichées quand la valeur dépasse cette plage. La valeur de l'altitude mesurée peut être négative dans les cas où une valeur de référence a été établie ou en raison de certaines conditions.
Le graphique de l'altitude comprend 14 colonnes et 9 rangs de points, chaque colonne de points représentant une période pendant laquelle les mesures d'altitude ont été prises, chaque point représentant une unité de 10 mètres (30 pieds).
Les relevés d'altitude sont effectués toutes les 5 secondes durant les 3 premières minutes et toutes les 5 minutes par la suite.
28
Loading...
+ 35 hidden pages