2
DCP0115
®
SPECIFICATIONS
At TA = +25°C, VS = +15V, unless otherwise specified.
DCP0115 SERIES
PARAMETER CONDITIONS MIN TYP MAX UNITS
OUTPUT
Power V
S
+ 4% 1 W
100% Full Load 0.92 W
Voltage (V
NOM
)
(1)
DCP011512D 75% Full Load ±10 ±12 ±12.6 V
DCP011515D 75% Full Load ±13 ±15 ±15.75 V
Voltage vs Temperature ±0.08 %/°C
Short Circuit Duration V
S
± 10% Indefinite
Ripple C
L
= O/P Capacitor = 10µF 6 mVp-p
100% Full Load
INPUT
Nominal Voltage (V
S
) 15 V
Voltage Range –10 10 %
Supply Current 100% Full Load 83 mA
Reflected Ripple Current C
IN
= I/P Capacitor = 1µF 8 mArms
50% Full Load
ISOLATION
Voltage
(2)
1s Flash Test 1 kVrms
Continuous Voltage
(3)
1 kVrms
Insulation Resistance >1 GΩ
Input/Output Capacitance 2.5 pF
LOAD REGULATION
DCP011512D 10% to 100% Load 20 39 %
10% to 25% Load 10 %
25% to 75% Load 5 %
75% to 100% Load –7 %
DCP011515D 10% to 100% Load 20 39 %
10% to 25% Load 10 %
25% to 75% Load 9 %
75% to 100% Load –4 %
SWITCHING/SYNCHRONIZATION
Oscillator Frequency (f
OSC
) Switching Frequency = f
OSC
/2 800 kHz
Sync Input Low 0 0.8 V
Sync Input Current V
SYNC
= +2V 48 µA
Reset Time 3.8 µs
SYNC
OUT
Frequency 400 kHz
GENERAL
No Load Current
DCP011512D 0% Load 14 mA
DCP011515D 0% Load 17 mA
Efficiency
DCP011512D 100% Full Load 76 %
10% Full Load 48 %
DCP011515D 100% Full Load 76 %
10% Full Load 42 %
MTTF
(3)
TA = +85°C 136,000 hrs
T
A
= +55°C 2,630,000 hrs
T
A
= +25°C 92,600,000 hrs
Weight 14-Pin PDIP 1.08 g
THERMAL SHUTDOWN
Die Temperature 115 140 °C
Shutdown Current 3mA
TEMPERATURE RANGE
Operating –40 100 °C
NOTES: (1) 100 % load current = 1W/V
NOM
typical. (2) Rated working voltage = 130Vrms (IEC950 convention). (3) Life test data.
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.